Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Pathogens ; 12(4)2023 Mar 24.
Artigo em Inglês | MEDLINE | ID: mdl-37111395

RESUMO

Proteus mirabilis (PM) is a Gram-negative, rod-shaped bacterium that causes catheter-associated urinary tract infections (CAUTIs). The specific roles of bacterial surface components (BSCs) in PM pathogenicity and CAUTIs remain unknown. To address this knowledge gap, we utilized relevant in vitro adhesion/invasion models and a well-established murine model of CAUTI to assess the ability of wildtype (WT) and seven mutant strains (MSs) of PM with deficiencies in various genes encoding BSCs to undergo the infectious process (including adhesion to catheters) in both model systems. Overall, MSs adhesion to catheters and the different cell types tested was significantly reduced compared to WT, while no invasion of cells was evident at 24 h. In vivo, WT showed a greater number of planktonic (urine) bacteria, bacteria adherent to catheters, and bacteria adherent to/invading bladder tissue when compared to the MSs. Bacterial counts in urine for PMI3191 and waaE mutants were lower than that for WT and other MSs. The complementation of mutated BSC genes resulting in the biggest defects restored the invasion phenotype both in vitro and in vivo. BSCs play a critical role at various steps in the pathogenicity of PM including adhesion to indwelling medical devices and adhesion/invasion of urinary tissue in vivo.

2.
ACS Nanosci Au ; 3(1): 67-83, 2023 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-36820095

RESUMO

A major medical device-associated complication is the biofilm-related infection post-implantation. One promising approach to prevent this is to coat already commercialized medical devices with effective antibiofilm materials. However, developing a robust high-performance antibiofilm coating on devices with a nonflat geometry remains unmet. Here, we report the development of a facile scalable nanoparticle-based antibiofilm silver composite coating with long-term activity applicable to virtually any objects including difficult-to-coat commercially available medical devices utilizing a catecholic organic-aqueous mixture. Using a screening approach, we have identified a combination of the organic-aqueous buffer mixture which alters polycatecholamine synthesis, nanoparticle formation, and stabilization, resulting in controlled deposition of in situ formed composite silver nanoparticles in the presence of an ultra-high-molecular-weight hydrophilic polymer on diverse objects irrespective of its geometry and chemistry. Methanol-mediated synthesis of polymer-silver composite nanoparticles resulted in a biocompatible lubricious coating with high mechanical durability, long-term silver release (∼90 days), complete inhibition of bacterial adhesion, and excellent killing activity against a diverse range of bacteria over the long term. Coated catheters retained their excellent activity even after exposure to harsh mechanical challenges (rubbing, twisting, and stretching) and storage conditions (>3 months stirring in water). We confirmed its excellent bacteria-killing efficacy (>99.999%) against difficult-to-kill bacteria (Proteus mirabilis) and high biocompatibility using percutaneous catheter infection mice and subcutaneous implant rat models, respectively, in vivo. The developed coating approach opens a new avenue to transform clinically used medical devices (e.g., urinary catheters) to highly infection-resistant devices to prevent and treat implant/device-associated infections.

3.
ACS Cent Sci ; 8(5): 546-561, 2022 May 25.
Artigo em Inglês | MEDLINE | ID: mdl-35647287

RESUMO

The long-term prevention of biofilm formation on the surface of indwelling medical devices remains a challenge. Silver has been reutilized in recent years for combating biofilm formation due to its indisputable bactericidal potency; however, the toxicity, low stability, and short-term activity of the current silver coatings have limited their use. Here, we report the development of silver-based film-forming antibacterial engineered (SAFE) assemblies for the generation of durable lubricous antibiofilm surface long-term activity without silver toxicity that was applicable to diverse materials via a highly scalable dip/spray/solution-skinning process. The SAFE coating was obtained through a large-scale screening, resulting in effective incorporation of silver nanoparticles (∼10 nm) into a stable nonsticky coating with high surface hierarchy and coverage, which guaranteed sustained silver release. The lead coating showed zero bacterial adhesion over a 1 month experiment in the presence of a high load of diverse bacteria, including difficult-to-kill and stone-forming strains. The SAFE coating showed high biocompatibility and excellent antibiofilm activity in vivo.

4.
ACS Appl Mater Interfaces ; 13(31): 36784-36799, 2021 Aug 11.
Artigo em Inglês | MEDLINE | ID: mdl-34328312

RESUMO

Bacterial adhesion and the succeeding biofilm formation onto surfaces are responsible for implant- and device-associated infections. Bifunctional coatings integrating both nonfouling components and antimicrobial peptides (AMPs) are a promising approach to develop potent antibiofilm coatings. However, the current approaches and chemistry for such coatings are time-consuming and dependent on substrates and involve a multistep process. Also, the information is limited on the influence of the coating structure or its components on the antibiofilm activity of such AMP-based coatings. Here, we report a new strategy to rapidly assemble a stable, potent, and substrate-independent AMP-based antibiofilm coating in a nonfouling background. The coating structure allowed for the screening of AMPs in a relevant nonfouling background to identify optimal peptide combinations that work in cooperation to generate potent antibiofilm activity. The structure of the coating was changed by altering the organization of the hydrophilic polymer chains within the coatings. The coatings were thoroughly characterized using various surface analytical techniques and correlated with the efficiency to prevent biofilm formation against diverse bacteria. The coating method that allowed the conjugation of AMPs without altering the steric protection ability of hydrophilic polymer structure results in a bifunctional surface coating with excellent antibiofilm activity. In contrast, the conjugation of AMPs directly to the hydrophilic polymer chains resulted in a surface with poor antibiofilm activity and increased adhesion of bacteria. Using this coating approach, we further established a new screening method and identified a set of potent surface-tethered AMPs with high activity. The success of this new peptide screening and coating method is demonstrated using a clinically relevant mouse infection model to prevent catheter-associated urinary tract infection (CAUTI).


Assuntos
Antibacterianos/farmacologia , Peptídeos Catiônicos Antimicrobianos/farmacologia , Incrustação Biológica/prevenção & controle , Materiais Revestidos Biocompatíveis/farmacologia , Proteínas Imobilizadas/farmacologia , Acrilamidas/química , Animais , Antibacterianos/síntese química , Peptídeos Catiônicos Antimicrobianos/síntese química , Catéteres/microbiologia , Materiais Revestidos Biocompatíveis/síntese química , Humanos , Proteínas Imobilizadas/síntese química , Indóis/química , Masculino , Camundongos Endogâmicos BALB C , Polímeros/química , Pseudomonas aeruginosa/efeitos dos fármacos , Pseudomonas aeruginosa/fisiologia , Staphylococcus saprophyticus/efeitos dos fármacos , Staphylococcus saprophyticus/fisiologia , Infecções Urinárias/prevenção & controle
5.
Adv Healthc Mater ; 10(6): e2001573, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-33470545

RESUMO

Catheter-associated urinary tract infections (CAUTIs) are one of the most commonly occurring hospital-acquired infections. Current coating strategies to prevent catheter-associated biofilm formation are limited by their poor long-term efficiency and limited applicability to diverse materials. Here, the authors report a highly effective non-fouling coating with long-term biofilm prevention activity and is applicable to diverse catheters. The thin coating is lubricous, stable, highly uniform, and shows broad spectrum prevention of biofilm formation of nine different bacterial strains and prevents the migration of bacteria on catheter surface. The coating method is adapted to human-sized catheters (both intraluminal and extraluminal) and demonstrates long-term biofilm prevention activity over 30 days in challenging conditions. The coated catheters are tested in a mouse CAUTI model and demonstrate high efficiency in preventing bacterial colonization of both Gram-positive and Gram-negative bacteria. Furthermore, the coated human-sized Foley catheters are evaluated in a porcine CAUTI model and show consistent efficiency in reducing biofilm formation by Escherichia coli (E. coli) over 95%. The simplicity of the coating method, the ability to apply this coating on diverse materials, and the high efficiency in preventing bacterial adhesion increase the potential of this method for the development of next generation infection resistant medical devices.


Assuntos
Infecções Relacionadas a Cateter , Animais , Antibacterianos , Biofilmes , Infecções Relacionadas a Cateter/prevenção & controle , Escherichia coli , Bactérias Gram-Negativas , Bactérias Gram-Positivas , Camundongos , Suínos , Cateteres Urinários
6.
Turk J Urol ; 46(Supp. 1): S11-S18, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-33052843

RESUMO

A ureteral stent is a commonly implanted urological device in patients with urinary tract obstruction. The main role of these stents is to allow adequate drainage of urine from the kidney into the bladder. Individuals with strictures, tumors, or obstructions from urinary stones do not have adequate urine flow and require ureteral stents as a part of their treatment to avoid potential hydronephrosis and renal failure. Although ureteral stents are highly effective in treating urinary tract obstructions, they have associated morbidities, such as biofilm formation and encrustation. Researchers have studied about how to diminish these negative outcomes by developing novel stent materials. Different coatings and biomaterials have been developed to reduce bacterial adhesion and crystal deposition onto the stent surfaces. Moreover, new investigation technologies, such as microfluidic platforms and encrustation sensors, have been utilized to better study the stents. Biofilms and encrustations can stem from bacterial origins; therefore, understanding the urinary microbiome will also provide insight into the solutions for treating them. There are still some gaps in our knowledge regarding the exact underlying mechanisms of stent-associated biofilms and encrustation. Future studies should include continuous testing of novel stent biomaterials for safety and efficacy, developing new technologies for identifying and extracting biofilms, enriching the assessment of stent encrustation, and diving deeper into understanding the urinary microbiome.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA