Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
1.
Vaccines (Basel) ; 12(5)2024 Apr 30.
Artigo em Inglês | MEDLINE | ID: mdl-38793733

RESUMO

COVID-19 vaccination strategies, including heterologous prime-boost regimens and additional booster doses, aim to optimize immune responses. However, seroepidemiological studies on immune responses to different COVID-19 vaccine types and schedules remain limited. This study investigated antibody levels following homologous and heterologous prime-and-boost COVID-19 vaccination in Bangladesh. In a cohort of 606 participants who received first/second/booster doses of vaccines (AstraZeneca, Moderna, Pfizer-BioNTech, and Sinopharm), anti-spike IgG and anti-nucleocapsid IgG levels were measured. Antibody titer variations with respect to age, gender, intervals between doses, and prior infection status were analyzed. mRNA vaccines elicited the highest antibody levels after homologous and heterologous boosting. The AstraZeneca booster resulted in a sharp titer decline rate of ~0.04 units per day. Second or booster vaccine doses significantly increased antibody levels, especially in males (p < 0.05). Older age correlated with higher titers, likely reflecting previous infection, which was further confirmed by the elevation of anti-nucleocapsid IgG levels. About 95.5% of non-Sinopharm recipients were anti-nucleocapsid IgG positive, suggesting prior exposure exceeding self-reported infections (12.5%). mRNA and heterologous COVID-19 boosting enhances humoral immunity over homologous prime-boost vector/inactivated vaccination. However, waning immunity merits further investigation across vaccine platforms.

2.
Cureus ; 15(10): e47683, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37899905

RESUMO

Introduction The overlap in clinical presentation between COVID-19 and dengue poses challenges for diagnosis in co-endemic regions. Furthermore, there have been reports of antibody cross-reactivity between SARS-CoV-2 and dengue. Our research aims to evaluate SARS-CoV-2 antigens for serological testing while reducing the possibility of cross-reactivity with anti-dengue antibodies. Method Two hundred and ten serum samples were collected from 179 patients and divided into four panels. Panels 1 and 2 consisted of COVID-19-negative healthy donors (n=81) and pre-pandemic dengue patients (n=50), respectively. Alternatively, Panel 3 (n=19) was composed of reverse transcription-quantitative polymerase chain reaction (RT-qPCR)-positive samples collected within two weeks of COVID-19 symptom onset, while Panel 4 (n=60) was composed of positive samples collected after two weeks of symptom onset. Previously developed and characterized in-house SARS-CoV-2 spike-1 (S1), receptor binding domain (RBD), and nucleocapsid (N) immunoglobin G (IgG)-enzyme-linked immunosorbent assay (ELISA) assays were used for the study. Results Six dengue-positive sera cross-reacted with the RBD of SARS-CoV-2. However, only one dengue-positive sera cross-reacted with the S1 and N proteins of SARS-CoV-2. Co-immobilization of S1 and RBD in different ratios revealed an 80:20 (S1:RBD) ratio as optimal for achieving an overall 96.2% sensitivity with the least cross-reaction to anti-dengue antibodies. Conclusion Our findings indicated that SARS-CoV-2 RBD-based immunoassays present more cross-reactivity with anti-dengue antibodies than S1 and N proteins. Furthermore, co-immobilization of S1 and RBD reduces the cross-reactivity with anti-dengue antibodies compared to RBD, thereby increasing the immunoassay specificity without affecting overall sensitivity for the dengue-endemic areas.

3.
Life (Basel) ; 12(5)2022 Apr 27.
Artigo em Inglês | MEDLINE | ID: mdl-35629317

RESUMO

With the progression of the COVID-19 pandemic, new technologies are being implemented for more rapid, scalable, and sensitive diagnostics. The implementation of microfluidic techniques and their amalgamation with different detection techniques has led to innovative diagnostics kits to detect SARS-CoV-2 antibodies, antigens, and nucleic acids. In this review, we explore the different microfluidic-based diagnostics kits and how their amalgamation with the various detection techniques has spearheaded their availability throughout the world. Three other online databases, PubMed, ScienceDirect, and Google Scholar, were referred for articles. One thousand one hundred sixty-four articles were determined with the search algorithm of microfluidics followed by diagnostics and SARS-CoV-2. We found that most of the materials used to produce microfluidics devices were the polymer materials such as PDMS, PMMA, and others. Centrifugal force is the most commonly used fluid manipulation technique, followed by electrochemical pumping, capillary action, and isotachophoresis. The implementation of the detection technique varied. In the case of antibody detection, spectrometer-based detection was most common, followed by fluorescence-based as well as colorimetry-based. In contrast, antigen detection implemented electrochemical-based detection followed by fluorescence-based detection, and spectrometer-based detection were most common. Finally, nucleic acid detection exclusively implements fluorescence-based detection with a few colorimetry-based detections. It has been further observed that the sensitivity and specificity of most devices varied with implementing the detection-based technique alongside the fluid manipulation technique. Most microfluidics devices are simple and incorporate the detection-based system within the device. This simplifies the deployment of such devices in a wide range of environments. They can play a significant role in increasing the rate of infection detection and facilitating better health services.

4.
FASEB Bioadv ; 4(6): 379-390, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35601057

RESUMO

Increased COVID-19 vaccine hesitancy presents a major hurdle in global efforts to contain the COVID-19 pandemic. This study was designed to estimate the prevalence of adverse events after the first dose of the Covishield (AstraZeneca) vaccine among physicians in Bangladesh. A cross-sectional study was conducted using an online questionnaire for physicians (n = 916) in Bangladesh. Physicians who received at least one dose of the COVID-19 vaccine were included. The study was carried out from April 12 to May 31, 2021. More than 58% of respondents (n = 533) reported one or more adverse events. Soreness of the injected arm (71.9%), tiredness (56.1%), fever (54.4%), soreness of muscles (48.4%), headache (41.5%) and sleeping more than usual (26.8%) were the most commonly reported adverse events. Most vaccine-related reactogenicities were reported by the younger cohorts (<45 years). The majority of respondents reported severity of reactogenicity as "mild," experienced on the day of vaccination, and lasting for 1-3 days. The most common reactogenicity was pain at the injection site; the second most common was tiredness. Almost half (49.2%) of the physicians took acetaminophen (paracetamol) to minimize the effects of vaccine reactogenicity. Multivariate logistic regression analyses showed that physicians with diabetes and hypertension (OR = 2.729 95% CI: 1.282-5.089) and asthma with other comorbidities (OR = 1.885 95% CI: 1.001-3.551) had a significantly higher risk of vaccine-related reactogenicities than physicians without comorbidities. Further safety studies with larger cohorts are required to monitor vaccine safety and provide assurance to potential vaccine recipients.

5.
Expert Rev Anti Infect Ther ; 20(3): 473-481, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34477019

RESUMO

BACKGROUND: Rapid increase in COVID-19 suspected cases has rendered disease diagnosis challenging, mainly depending upon RT-qPCR. Reliable, rapid, and cost-effective diagnostic assays that complement RT-qPCR should be introduced after thoroughly evaluating their performance upon various disease phases, viral load, and sample storage conditions. OBJECTIVE: We investigated the correlation of cycle threshold (Ct) value, which implies the viral load and infection phase, and the storage condition of the clinical specimen with the diagnosis of SARS-CoV-2 through our newly developed in-house rapid enzyme-linked immunosorbent assay (ELISA) system. METHOD: Naso-oropharyngeal samples of 339 COVID-19 suspected cases were collected and evaluated through RT-qPCR that were stored up to 30 days in different conditions (i.e. -80°C, -20°C and initially at 4°C followed by -80°C). The clinical specimens were evaluated with our in-house ELISA system after finalizing the assay method through checkerboard assay and minimizing the signal/noise ratio. RESULT: The ELISA system showed the highest sensitivity (92.9%) for samples with Ct ≤30 and preserving at -80°C temperature. The sensitivity reduced proportionally with increasing Ct value and preserving temperature. However, the specificity ranged between 98.3% and 100%. CONCLUSION: The results indicate the necessity of early infection phase diagnosis and lower temperature preservation of samples to perform rapid antigen ELISA tests.


Assuntos
COVID-19 , SARS-CoV-2 , Manejo de Espécimes , Carga Viral , COVID-19/diagnóstico , Ensaio de Imunoadsorção Enzimática , Humanos , SARS-CoV-2/isolamento & purificação , Sensibilidade e Especificidade
6.
Vaccines (Basel) ; 9(12)2021 Nov 24.
Artigo em Inglês | MEDLINE | ID: mdl-34960133

RESUMO

COVID-19 vaccines are indispensable, with the number of cases and mortality still rising, and currently no medicines are routinely available for reducing morbidity and mortality, apart from dexamethasone, although others are being trialed and launched. To date, only a limited number of vaccines have been given emergency use authorization by the US Food and Drug Administration and the European Medicines Agency. There is a need to systematically review the existing vaccine candidates and investigate their safety, efficacy, immunogenicity, unwanted events, and limitations. The review was undertaken by searching online databases, i.e., Google Scholar, PubMed, and ScienceDirect, with finally 59 studies selected. Our findings showed several types of vaccine candidates with different strategies against SARS-CoV-2, including inactivated, mRNA-based, recombinant, and nanoparticle-based vaccines, are being developed and launched. We have compared these vaccines in terms of their efficacy, side effects, and seroconversion based on data reported in the literature. We found mRNA vaccines appeared to have better efficacy, and inactivated ones had fewer side effects and similar seroconversion in all types of vaccines. Overall, global variant surveillance and systematic tweaking of vaccines, coupled with the evaluation and administering vaccines with the same or different technology in successive doses along with homologous and heterologous prime-booster strategy, have become essential to impede the pandemic. Their effectiveness appreciably outweighs any concerns with any adverse events.

7.
Expert Rev Vaccines ; 20(12): 1651-1660, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34503369

RESUMO

BACKGROUND: Vaccination with the Oxford-AstraZeneca COVID-19 vaccine (AZD1222) initially started in the UK and quickly implemented around the Globe, including Bangladesh. Up to date, more than nine million doses administrated to the Bangladeshi public. METHOD: Herein, we studied the antibody response to the first dose of AZD1222 in 86 Bangladeshi individuals using in-house ELISA kits. Study subjects were categorized into two groups, convalescent and uninfected, based on prior infection history and SARS-CoV-2 nucleocapsid-IgG profiles. RESULTS: All the convalescent individuals presented elevated spike-1-IgG compared to 90% of uninfected ones after the first dose. Day >28 post-vaccination, the convalescent group showed six times higher antibody titer than the uninfected ones. The most elevated antibody titers for the former and later group were found at Day 14 and Days >28 post-vaccination, respectively. The spike-1-IgA titer showed a similar pattern as spike-1-IgG, although in a low-titer. In contrast, the IgM titer did not show any significant change in either group. CONCLUSION: High antibody titer in the convalescent group, signify the importance of the first dose among the uninfected group. This study advocates the integration of antibody tests in vaccination programs in the healthcare system for maximizing benefit.


Assuntos
Anticorpos Antivirais/sangue , Formação de Anticorpos , Vacinas contra COVID-19/imunologia , COVID-19 , Bangladesh , ChAdOx1 nCoV-19 , Humanos , Imunoglobulina A/sangue , Imunoglobulina G/sangue , Imunoglobulina M/sangue
8.
Expert Rev Vaccines ; 20(9): 1167-1175, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-34224292

RESUMO

BACKGROUND: Acceptance of the COVID-19 vaccine by the target groups would play a crucial role in stemming the pandemic. Healthcare professionals (HCPs) are the priority group for vaccination due to them having the highest risk of exposure to infection. This survey aimed to assess their acceptance of COVID-19 vaccines in Bangladesh. RESEARCH DESIGN AND METHODS: A cross-sectional survey using an online questionnaire was conducted between January 3 to 25, 2021, among HCPs (n = 834) in Bangladesh. RESULTS: Less than 50% of HCPs would receive the vaccine against COVID-19 if available and 54% were willing to take the vaccine at some stage in the future. Female participants (OR:1.64;95%CI:1.172-2.297), respondents between 18-34 years old (OR:2.42; 95% CI:1.314-4.463), HCPs in the public sector (OR:2.09; 95% CI:1.521-2.878), and those who did not receive a flu vaccine in the previous year (OR:3.1; 95% CI:1.552-6.001) were more likely to delay vaccination. CONCLUSIONS: The study revealed that, if available, less than half of the HCPs would accept a COVID-19 vaccine in Bangladesh. To ensure the broader success of the vaccination drive, tailored strategies and vaccine promotion campaigns targeting HCPs and the general population are needed.


Assuntos
Atitude do Pessoal de Saúde , Vacinas contra COVID-19/imunologia , COVID-19/prevenção & controle , Pessoal de Saúde/psicologia , Aceitação pelo Paciente de Cuidados de Saúde/estatística & dados numéricos , Recusa de Vacinação/estatística & dados numéricos , Adulto , Bangladesh , Estudos Transversais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , SARS-CoV-2/imunologia , Inquéritos e Questionários , Vacinação/estatística & dados numéricos , Adulto Jovem
9.
Int J Nanomedicine ; 16: 4739-4753, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34267520

RESUMO

BACKGROUND: Serological tests detecting severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2) are widely used in seroprevalence studies and evaluating the efficacy of the vaccination program. Some of the widely used serological testing techniques are enzyme-linked immune-sorbent assay (ELISA), chemiluminescence immunoassay (CLIA), and lateral flow immunoassay (LFIA). However, these tests are plagued with low sensitivity or specificity, time-consuming, labor-intensive, and expensive. We developed a serological test implementing flow-through dot-blot assay (FT-DBA) for SARS-CoV-2 specific IgG detection, which provides enhanced sensitivity and specificity while being quick to perform and easy to use. METHODS: SARS-CoV-2 antigens were immobilized on nitrocellulose membrane to capture human IgG, which was then detected with anti-human IgG conjugated gold nanoparticle (hIgG-AuNP). A total of 181 samples were analyzed in-house. Within which 35 were further evaluated in US FDA-approved CLIA Elecsys SARS-CoV-2 assay. The positive panel consisted of RT-qPCR positive samples from patients with both <14 days and >14 days from the onset of clinical symptoms. The negative panel contained samples collected from the pre-pandemic era dengue patients and healthy donors during the pandemic. Moreover, the sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of FT-DBA were evaluated against RT-qPCR positive sera. However, the overall efficacies were assessed with sera that seroconverted against either nucleocapsid (NCP) or receptor-binding domain (RBD). RESULTS: In-house ELISA selected a total of 81 true seropositive and 100 seronegative samples. The sensitivity of samples with <14 days using FT-DBA was 94.7%, increasing to 100% for samples >14 days. The overall detection sensitivity and specificity were 98.8% and 98%, respectively, whereas the overall PPV and NPV were 99.6% and 99%. Moreover, comparative analysis between in-house ELISA assays and FT-DBA revealed clinical agreement of Cohen's Kappa value of 0.944. The FT-DBA showed sensitivity and specificity of 100% when compared with commercial CLIA kits. CONCLUSION: The assay can confirm past SARS-CoV-2 infection with high accuracy within 2 minutes compared to commercial CLIA or in-house ELISA. It can help track SARS-CoV-2 disease progression, population screening, and vaccination response. The ease of use of the assay without requiring any instruments while being semi-quantitative provides the avenue of its implementation in remote areas around the globe, where conventional serodiagnosis is not feasible.


Assuntos
Ouro/química , Immunoblotting/métodos , Imunoglobulina G/análise , Nanopartículas Metálicas/química , Nucleocapsídeo/análise , SARS-CoV-2/isolamento & purificação , Adulto , Anticorpos Antivirais/sangue , Humanos , Imunoglobulina G/sangue , Imunoglobulina G/imunologia , Masculino , Valor Preditivo dos Testes , SARS-CoV-2/imunologia , Sensibilidade e Especificidade , Estudos Soroepidemiológicos
10.
J Inflamm Res ; 14: 2497-2506, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34163208

RESUMO

BACKGROUND: Dynamics and persistence of neutralizing and non-neutralizing antibodies can give us the knowledge required for serodiagnosis, disease management, and successful vaccine design and development. The disappearance of antibodies, absence of humoral immunity activation, and sporadic reinfection cases emphasize the importance of longitudinal antibody dynamics against variable structural antigens. METHODS: In this study, twenty-five healthy subjects working in a SARS-COV-2 serodiagnostic assay development project were enrolled, and their sign and symptoms were followed up to six months. Three subjects showed COVID-19-like symptoms, and three subjects' antibody dynamics were followed over 120 days by analyzing 516 samples. We have developed 12 different types of in-house ELISAs to observe the kinetics of IgG, IgM, and IgA against four SARS-CoV-2 proteins, namely nucleocapsid, RBD, S1, and whole spike (S1+S2). For the development of these assays, 30-104 pre-pandemic samples were taken as negative controls and 83 RT-qPCR positive samples as positive ones. RESULTS: All three subjects presented COVID-19-like symptoms twice, with mild symptoms in the first episode were severe in the second, and RT-qPCR confirmed the latter. The initial episode did not culminate with any significant antibody development, while a multifold increase in IgG antibodies characterized the second episode. Interestingly, IgG antibody development concurrent with IgM and IgA and persisted, whereas the latter two weans off rather quickly if appeared. CONCLUSION: Antibody kinetics observed in this study can provide a pathway to the successful development of sero-diagnostics and epidemiologists to predict the fate of vaccination currently in place.

11.
Infect Drug Resist ; 14: 1049-1082, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33762831

RESUMO

Recent severe acute respiratory syndrome 2 (SARS-CoV-2) known as COVID-19, presents a deadly challenge to the global healthcare system of developing and developed countries, exposing the limitations of health facilities preparedness for emerging infectious disease pandemic. Opportune detection, confinement, and early treatment of infected cases present the first step in combating COVID-19. In this review, we elaborate on various COVID-19 diagnostic tools that are available or under investigation. Consequently, cell culture, followed by an indirect fluorescent antibody, is one of the most accurate methods for detecting SARS-CoV-2 infection. However, restrictions imposed by the regulatory authorities prevented its general use and implementation. Diagnosis via radiologic imaging and reverse transcriptase PCR assay is frequently employed, considered as standard procedures, whereas isothermal amplification methods are currently on the verge of clinical introduction. Notably, techniques such as CRISPR-Cas and microfluidics have added new dimensions to the SARS-CoV-2 diagnosis. Furthermore, commonly used immunoassays such as enzyme-linked immunosorbent assay (ELISA), lateral flow immunoassay (LFIA), neutralization assay, and the chemiluminescent assay can also be used for early detection and surveillance of SARS-CoV-2 infection. Finally, advancement in the next generation sequencing (NGS) and metagenomic analysis are smoothing the viral detection further in this global challenge.

12.
Microbiol Resour Announc ; 10(10)2021 Mar 11.
Artigo em Inglês | MEDLINE | ID: mdl-33707329

RESUMO

Here, we report the coding-complete genome sequences of nine clinical severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) variants and their mutations. The samples were collected from nine Bangladeshi coronavirus disease 2019 (COVID-19) patients. We have identified the E484K escape mutation and the S359T mutation within the spike protein coding region of the sequenced genomes.

13.
PLoS One ; 16(2): e0246346, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33529223

RESUMO

BACKGROUND: In the ongoing pandemic situation of COVID-19, serological tests can complement the molecular diagnostic methods, and can be one of the important tools of sero-surveillance and vaccine evaluation. AIM: To develop and evaluate a rapid SARS-CoV-2 specific ELISA for detection of anti-SARS-CoV2 IgG from patients' biological samples. METHODS: In order to develop this ELISA, three panels of samples (n = 184) have been used: panel 1 (n = 19) and panel 2 (n = 60) were collected from RT-PCR positive patients within 14 and after 14 days of onset of clinical symptoms, respectively; whereas panel 3 consisted of negative samples (n = 105) collected either from healthy donors or pre-pandemic dengue patients. As a capturing agent full-length SARS-CoV2 specific recombinant nucleocapsid was immobilized. Commercial SARS-CoV2 IgG kit based on chemiluminescent assay was used for the selection of samples and optimization of the assay. The threshold cut-off point, inter-assay and intra-assay variations were determined. RESULTS: The incubation/reaction time was set at a total of 30 minutes with the sensitivity of 84% (95% confidence interval, CI, 60.4%, 96.6%) and 98% (95% CI, 91.1%, 100.0%), for panel 1 and 2, respectively; with overall 94.9% sensitivity (95% CI 87.5%, 98.6%). Moreover, the clinical specificity was 97.1% (95% CI, 91.9%, 99.4%) with no cross reaction with dengue samples. The overall positive and negative predictive values are 96.2% (95% CI 89.2%, 99.2%) and 96.2% (95% CI, 90.6% 99.0%), respectively. In-house ELISA demonstrated 100% positive and negative percent agreement with Elecsys Anti-SARS-CoV-2, with Cohen's kappa value of 1.00 (very strong agreement), while comparing 13 positive and 17 negative confirmed cases. CONCLUSION: The assay is rapid and can be applied as one of the early and retrospective sero-monitoring tools in all over the affected areas.


Assuntos
Anticorpos Antivirais/análise , Proteínas do Nucleocapsídeo de Coronavírus/análise , Ensaio de Imunoadsorção Enzimática/métodos , SARS-CoV-2/isolamento & purificação , COVID-19/diagnóstico , COVID-19/virologia , Ensaio de Imunoadsorção Enzimática/instrumentação , Humanos , Imunoglobulina G/análise , Fosfoproteínas/análise , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA