Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Pain Ther ; 2024 Jul 09.
Artigo em Inglês | MEDLINE | ID: mdl-38977651

RESUMO

INTRODUCTION: Drawbacks of fixed-output spinal cord stimulation (SCS) screening trials may lead to compromised trial outcomes and poor predictability of long-term success. Evoked compound action potential (ECAP) dose-controlled closed-loop (CL) SCS allows objective confirmation of therapeutic neural activation and pulse-to-pulse stimulation adjustment. We report on the immediate patient-reported and neurophysiologic treatment response post-physiologic CL-SCS and feasibility of early SCS trial responder prediction. METHODS: Patient-reported pain relief, functional improvement, and willingness to proceed to permanent implant were compared between the day of the trial procedure (Day 0) and end of trial (EOT) for 132 participants in the ECAP Study undergoing a trial stimulation period. ECAP-based neurophysiologic measurements from Day 0 and EOT were compared between responder groups. RESULTS: A high positive predictive value (PPV) was achieved with 98.4% (60/61) of patients successful on the Day 0 evaluation also responding at EOT. The false-positive rate (FPR) was 5.6% (1/18). ECAP-based neurophysiologic measures were not different between patients who passed all Day 0 success criteria ("Day 0 successes") and those who did not ("needed longer to evaluate the therapy"). However, at EOT, responders had higher therapeutic usage and dose levels compared to non-responders. CONCLUSIONS: The high PPV and low FPR of the Day 0 evaluation provide confidence in predicting trial outcomes as early as the day of the procedure. Day 0 trials may be beneficial for reducing patient burden and complication rates associated with extended trials. ECAP dose-controlled CL-SCS therapy may provide objective data and rapid-onset pain relief to improve prognostic ability of SCS trials in predicting outcomes. TRIAL REGISTRATION: The ECAP Study is registered with ClinicalTrials.gov (NCT04319887).

2.
Reg Anesth Pain Med ; 2023 Aug 27.
Artigo em Inglês | MEDLINE | ID: mdl-37640452

RESUMO

INTRODUCTION: The evidence for spinal cord stimulation (SCS) has been criticized for the absence of blinded, parallel randomized controlled trials (RCTs) and limited evaluations of the long-term effects of SCS in RCTs. The aim of this study was to determine whether evoked compound action potential (ECAP)-controlled, closed-loop SCS (CL-SCS) is associated with better outcomes when compared with fixed-output, open-loop SCS (OL-SCS) 36 months following implant. METHODS: The EVOKE study was a multicenter, participant-blinded, investigator-blinded, and outcome assessor-blinded, randomized, controlled, parallel-arm clinical trial that compared ECAP-controlled CL-SCS with fixed-output OL-SCS. Participants with chronic, intractable back and leg pain refractory to conservative therapy were enrolled between January 2017 and February 2018, with follow-up through 36 months. The primary outcome was a reduction of at least 50% in overall back and leg pain. Holistic treatment response, a composite outcome including pain intensity, physical and emotional functioning, sleep, and health-related quality of life, and objective neural activation was also assessed. RESULTS: At 36 months, more CL-SCS than OL-SCS participants reported ≥50% reduction (CL-SCS=77.6%, OL-SCS=49.3%; difference: 28.4%, 95% CI 12.8% to 43.9%, p<0.001) and ≥80% reduction (CL-SCS=49.3%, OL-SCS=31.3%; difference: 17.9, 95% CI 1.6% to 34.2%, p=0.032) in overall back and leg pain intensity. Clinically meaningful improvements from baseline were observed at 36 months in both CL-SCS and OL-SCS groups in all other patient-reported outcomes with greater levels of improvement with CL-SCS. A greater proportion of patients with CL-SCS were holistic treatment responders at 36-month follow-up (44.8% vs 28.4%), with a greater cumulative responder score for CL-SCS patients. Greater neural activation and accuracy were observed with CL-SCS. There were no differences between CL-SCS and OL-SCS groups in adverse events. No explants due to loss of efficacy were observed in the CL-SCS group. CONCLUSION: This long-term evaluation with objective measurement of SCS therapy demonstrated that ECAP-controlled CL-SCS resulted in sustained, durable pain relief and superior holistic treatment response through 36 months. Greater neural activation and increased accuracy of therapy delivery were observed with ECAP-controlled CL-SCS than OL-SCS. TRIAL REGISTRATION NUMBER: NCT02924129.

3.
JAMA Neurol ; 79(3): 251-260, 2022 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-34998276

RESUMO

Importance: Chronic pain is debilitating and profoundly affects health-related quality of life. Spinal cord stimulation (SCS) is a well-established therapy for chronic pain; however, SCS has been limited by the inability to directly measure the elicited neural response, precluding confirmation of neural activation and continuous therapy. A novel SCS system measures the evoked compound action potentials (ECAPs) to produce a real-time physiological closed-loop control system. Objective: To determine whether ECAP-controlled, closed-loop SCS is associated with better outcomes compared with fixed-output, open-loop SCS at 24 months following implant. Design, Setting, and Participants: The Evoke study was a double-blind, randomized, controlled, parallel arm clinical trial with 36 months of follow-up. Participants were enrolled from February 2017 to 2018, and the study was conducted at 13 US investigation sites. SCS candidates with chronic, intractable back and leg pain refractory to conservative therapy, who consented, were screened. Key eligibility criteria included overall, back, and leg pain visual analog scale score of 60 mm or more; Oswestry Disability Index score of 41 to 80; stable pain medications; and no previous SCS. Analysis took place from October 2020 to April 2021. Interventions: ECAP-controlled, closed-loop SCS was compared with fixed-output, open-loop SCS. Main Outcomes and Measures: Reported here are the 24-month outcomes of the trial, which include all randomized patients in the primary and safety analyses. The primary outcome was a reduction of 50% or more in overall back and leg pain assessed at 3 and 12 months (previously published). Results: Of 134 randomized patients, 65 (48.5%) were female and the mean (SD) age was 55.2 (10.6) years. At 24 months, significantly more closed-loop than open-loop patients were responders (≥50% reduction) in overall pain (53 of 67 [79.1%] in the closed-loop group; 36 of 67 [53.7%] in the open-loop group; difference, 25.4% [95% CI, 10.0%-40.8%]; P = .001). There was no difference in safety profiles between groups (difference in rate of study-related adverse events: 6.0 [95% CI, -7.8 to 19.7]). Improvements were also observed in health-related quality of life, physical and emotional functioning, and sleep, in parallel with opioid reduction or elimination. Objective neurophysiological measurements substantiated the clinical outcomes and provided evidence of activation of inhibitory pain mechanisms. Conclusions and Relevance: ECAP-controlled, closed-loop SCS, which elicited a more consistent neural response, was associated with sustained superior pain relief at 24 months, consistent with the 3- and 12-month outcomes.


Assuntos
Dor Crônica , Estimulação da Medula Espinal , Dor Crônica/terapia , Feminino , Humanos , Perna (Membro) , Pessoa de Meia-Idade , Medição da Dor , Qualidade de Vida , Medula Espinal , Resultado do Tratamento
4.
J Neural Eng ; 14(3): 036027, 2017 06.
Artigo em Inglês | MEDLINE | ID: mdl-28322213

RESUMO

OBJECTIVE: Our goal is to develop an interface that integrates chronic monitoring of lower urinary tract (LUT) activity with stimulation of peripheral pathways. APPROACH: Penetrating microelectrodes were implanted in sacral dorsal root ganglia (DRG) of adult male felines. Peripheral electrodes were placed on or in the pudendal nerve, bladder neck and near the external urethral sphincter. Supra-pubic bladder catheters were implanted for saline infusion and pressure monitoring. Electrode and catheter leads were enclosed in an external housing on the back. Neural signals from microelectrodes and bladder pressure of sedated or awake-behaving felines were recorded under various test conditions in weekly sessions. Electrodes were also stimulated to drive activity. MAIN RESULTS: LUT single- and multi-unit activity was recorded for 4-11 weeks in four felines. As many as 18 unique bladder pressure single-units were identified in each experiment. Some channels consistently recorded bladder afferent activity for up to 41 d, and we tracked individual single-units for up to 23 d continuously. Distension-evoked and stimulation-driven (DRG and pudendal) bladder emptying was observed, during which LUT sensory activity was recorded. SIGNIFICANCE: This chronic implant animal model allows for behavioral studies of LUT neurophysiology and will allow for continued development of a closed-loop neuroprosthesis for bladder control.


Assuntos
Eletrodos Implantados , Gânglios Espinais/fisiologia , Monitorização Fisiológica/instrumentação , Nervo Pudendo/fisiologia , Bexiga Urinária/fisiologia , Micção/fisiologia , Animais , Gatos , Desenho de Equipamento , Análise de Falha de Equipamento , Masculino , Monitorização Fisiológica/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Bexiga Urinária/inervação
5.
Artigo em Inglês | MEDLINE | ID: mdl-24110366

RESUMO

The combination of optical stimulation and electrical recording is commonly employed in neuroscience research. Researchers using optogenetics are familiar with the photo-induced "artifacts" that arise from illumination of an electrode array. We sought to characterize this photoelectrochemical (PEC) effect to understand the underlying mechanism seen on NeuroNexus optoelectrodes. In doing so, we discovered that the phenomenon is inversely proportional to electrode site area in the same manner as electrical impedance measurements. We have applied the PEC effect as a method of electrode evaluation and show that a PEC measurement system can be both faster and more effective than impedance at sensing defects in high-throughput biomedical device testing.


Assuntos
Impedância Elétrica , Eletroquímica/instrumentação , Eletrodos Implantados , Fotoquímica/instrumentação , Processamento de Sinais Assistido por Computador , Artefatos , Eletroquímica/métodos , Eletrodos , Eletrólitos/química , Desenho de Equipamento , Concentração de Íons de Hidrogênio , Luz , Óptica e Fotônica , Optogenética , Estimulação Luminosa , Fotoquímica/métodos , Potenciometria , Software , Espectrofotometria/instrumentação , Espectrofotometria/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA