Ann Biomed Eng ; 52(2): 302-317, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37777691

RESUMO

Pediatric patients with heart failure have limited treatment options because of a shortage of donor hearts and compatible left ventricular assist devices (LVADs). To address this issue, our group is developing an implantable pediatric LVAD for patients weighing 5-20 kg, capable of accommodating different physiological hemodynamic conditions as patients grow. To evaluate LVAD prototypes across a wide range of conditions, we developed a numerical cardiovascular model, using data from a mock circulatory loop (MCL) and patient-specific elastance functions. The numerical MCL was validated against experimental MCL results, showing good agreement, with differences ranging from 0 to 11%. The numerical model was also tested under left heart failure conditions and showed a worst-case difference of 16%. In an MCL study with a pediatric LVAD, a pediatric dataset was obtained from the experimental MCL and used to tune the numerical MCL. Then, the numerical model simulated LVAD flow by using an HQ curve obtained from the LVAD's impeller. When the numerical MCL was validated against the experimental MCL, hemodynamic differences ranged between 0 and 9%. These findings suggest that the numerical model can replicate various physiological conditions and impeller designs, indicating its potential as a tool for developing and optimizing pediatric LVADs.


Assuntos
Insuficiência Cardíaca , Transplante de Coração , Coração Auxiliar , Humanos , Criança , Modelos Cardiovasculares , Doadores de Tecidos , Hemodinâmica
2.
Artigo em Inglês | MEDLINE | ID: mdl-38082725

RESUMO

The Hemocompatibility Assessment Platform (HAP) is a testing rig that will allow for the evaluation of blood trauma caused by individual components of rotary blood pumps including the NeoVAD - a proposed paediatric Left Ventricular Assist Device (LVAD). It is important that the HAP itself is only minimally haemolytic such that the plasma free haemoglobin measured can be assumed to come from the test component. In this study, Computational Fluid Dynamics simulations have been carried out to inform the design of a magnetically levitated motor bearing gap. Simulations show that issues with the original design, namely stagnation regions and large recirculation zones can be mitigated with the introduction of a pipe that introduces blood-flow to the centre of the bearing and disrupts the secondary flow patterns that cause these issues.Clinical relevance- The consequent reduction in shear exposure time will reduce heamolsyis from the HAP. The redesign of the bearing will result in reduced baseline blood trauma from the HAP, thus allowing quantification of test component haemolysis and will therefore aid the design of future paediatric LVADs.


Assuntos
Coração Auxiliar , Hidrodinâmica , Humanos , Criança , Hemodinâmica , Magnetismo , Hemólise , Fenômenos Magnéticos
3.
Annu Int Conf IEEE Eng Med Biol Soc ; 2022: 2294-2297, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-36086211

RESUMO

To evaluate the hemocompatibility of individual components of our pediatric left ventricular assist device (LVAD), we proposed a hemocompatibility assessment platform (HAP) with a magnetic levitated bearing system. The HAP consists of a drive system utilizing a brushless direct current (BLDC) motor, passive magnetic bearings (PMB), and an active magnetically levitated bearing (AMB) to reduce the hemolysis generated by HAP itself. In this study, we designed and evaluated the performance of the AMB by measuring radial and axial displacements of the rotor resulting from radially destabilizing forces as well as the performance of the drive system when rotated at increasing speeds to 1,200 rotations per minute (rpm). The results show that, with radial disturbance, the AMB is capable of maintaining axial stability for the BLDC motor system. The AMB can control up to 1,200 rpm without any contact between the rotor and stator. Future work includes geometry optimization for the AMB structure and increase the capability to control stable high-speed rotation for the entire system. Clinical Relevance- This work furthers the development of the magnetic levitated bearing system for a hemocompatibility assessment platform that will be used to enhance and accelerate the development of adult and pediatric LVADs.


Assuntos
Coração Auxiliar , Magnetismo , Criança , Eletricidade , Desenho de Equipamento , Coração Auxiliar/efeitos adversos , Hemólise , Humanos
4.
Annu Int Conf IEEE Eng Med Biol Soc ; 2022: 2282-2285, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-36086595

RESUMO

Development of pediatric left ventricular assist devices (LVADs) has lagged behind that of adult LVADs, primarily due to the size and hemocompatibility constraints of pediatric anatomy. To quantify sources of blood trauma during LVAD development, we proposed a hemocompatibility assessment platform (HAP) that can evaluate the hemocompatibility of individual components of LVADs. To eliminate the hemolysis induced by the HAP itself, we incorporated passive magnetic (PM) bearings to suspend the rotor radially and an active magnetic bearing (AMB) to control the axial position. In this study, we numerically evaluated AMB forces of 2 geometries and validated the model by comparing its predictions with experimental results. The magnetic forces generated by the AMB were evaluated by increasing the rotor-stator gap from 0.1 mm to 0.5 mm with a 0.1 mm increment and by varying the coil current from -2 A to 2 A with a 1 A increment. The average error of the numerical models was 8.8% and 7.0% for the two geometries, respectively. Higher errors were found at smaller (<0.2mm) rotor-stator gaps. For both biasing ring sizes, the AMB exhibits high magnetic stiffness from -1 A to 1 A, though it saturates for currents of -2 A and 2 A. This region of high current stiffness was identified as the optimal control region. In future work, this function will be used to tune a control algorithm to modulate current supplied to the AMB, ultimately stabilizing the rotor axially. Clinical Relevance- This work furthers the development of a hemocompatibility assessment platform that will enhance and accelerate the development of adult and pediatric LVADs.


Assuntos
Coração Auxiliar , Magnetismo , Criança , Desenho de Equipamento , Coração Auxiliar/efeitos adversos , Hemólise , Humanos , Fenômenos Magnéticos
5.
Annu Int Conf IEEE Eng Med Biol Soc ; 2022: 4005-4009, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-36086604

RESUMO

The human heart is responsible for maintaining constant, pulsatile blood flow in the human body. Mock circulatory loops (MCLs) have long been used as the mechanical representations of the human cardiovascular system and as test beds for mechanical circulatory support (MCS) devices and other interventional medical devices. This technology could also be used as a training and educational tool for surgeons/clinicians. To ensure the MCL can accurately simulate the pulsatile human cardiovascular system, it is essential that the MCL can reproduce human physiological responses, e.g., the Frank-Starling Mechanism, in a controllable operating environment. In this study, by using an elastance function template to control the simulated left ventricle, we created controllable pulsatile physiological flow in a 3D printed silicone vascular structure to successfully simulate the hemodynamic environment of the human cardiovascular system. Clinical Relevance- This work will provide an in vitro test platform to simulate the human cardiovascular system. The accurate simulation of human cardiovascular anatomy and hemodynamic environment will allow this device to be an ideal training/educational tool for surgeons/clinicians to recreate various physiological conditions that cannot be created in vivo in animal or cadaver models.


Assuntos
Coração Auxiliar , Algoritmos , Animais , Ventrículos do Coração , Humanos , Modelos Cardiovasculares , Impressão Tridimensional