Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
1.
Radiology ; 310(1): e232128, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38226878

RESUMO

Background Fluoroscopy is an imaging modality associated with a wide range of dose levels, characterized using a variety of dose metrics, including effective dose. However, for clinical procedures, effective dose is a seldom-used and unregulated metric in the United States, and thus, it is not extensively studied in radiology despite potentially large clinical implications for patients, especially children and infants. Purpose To formulate and report a dose catalog across all diagnostic and interventional radiology (IR) fluoroscopy examination or procedure types at a specialized tertiary care pediatric hospital. Materials and Methods In this retrospective study, dose metrics taken from radiation dose structured reports of fluoroscopy between October 2014 and March 2023 were analyzed. The reports included fluoroscopy across 18 diagnostic examination types and 24 IR procedure types. The National Cancer Institute dosimetry system for Radiography and Fluoroscopy Monte Carlo software was used to estimate age-specific effective dose from dose-area product (DAP). The DAP-to-effective dose conversion factors were estimated per IR procedure type and diagnostic fluoroscopy examination type based on age. Results A total of 11 536 individual diagnostic fluoroscopy examinations (18 types) and 8017 individual IR procedures (24 types) were analyzed. Median effective dose values per diagnostic fluoroscopy examination type ranged from 0.0010 to 0.44 mSv (mean, 0.0808 mSv ± 0.0998 [SD]). Calculated DAP-to-effective dose conversion factors ranged from 0.04 to 2.48 mSv/Gy · cm2 (mean, 0.758 mSv/Gy · cm2 ± 0.614) across all diagnostic fluoroscopy examination types. Median effective dose values per IR procedure type ranged from 0.0007 to 3.90 mSv (mean, 0.6757 mSv ± 0.8989). Calculated DAP-to-effective dose conversion factors ranged from 0.001 to 0.87 mSv/Gy · cm2 (mean, 0.210 mSv/Gy · cm2 ± 0.235) across all IR procedure types. Conclusion A pediatric fluoroscopy dose catalog was created, including age-specific effective dose, using a repeatable robust method based on accurate clinical data. © RSNA, 2024 Supplemental material is available for this article. See also the editorial by Borrego and Balter in this issue.


Assuntos
Hospitais Pediátricos , Radiologia Intervencionista , Lactente , Humanos , Criança , Estudos Retrospectivos , Fluoroscopia , Fatores Etários
2.
J Pediatr Orthop ; 43(7): 414-417, 2023 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-37104779

RESUMO

BACKGROUND: Orthopaedic surgeons are exposed to high levels of radiation, which may lead to higher rates of cancer among orthopaedic surgeons. There are a series of techniques currently practiced to pin supracondylar humerus fractures including pinning the arm on the C-arm itself, using a plexiglass rectangle or a graphite floating arm board; however, the variation in radiation exposure to the surgeon is unknown. We aimed to determine how the position of the C-arm affects radiation exposure to the surgeon during the treatment of a pediatric supracondylar humerus fracture. MATERIAL AND METHODS: A simulated operating room was created to simulate a closed reduction and percutaneous pinning of a supracondylar humerus fracture. A phantom model was used to simulate the patient's arm. We assessed performing the procedure with the arm on plexiglass, graphite, or on top of the C-arm image receptor. The C-arm was positioned either with the source down and image receptor up (standard position) or with the source up and image receptor down (inverted position). Radiation exposure was recorded from levels corresponding to the surgeon's head, midline, and groin. The estimated effective dose equivalent was calculated to account for the varying radiation sensitivity of different organs. RESULTS: We found the effective dose equivalent, or the overall body damage from radiation, was 5.4 to 7.8% higher than the surgeon when the C-arm was in the inverted position (source up, image receptor down). We did not find any differences in radiation exposure to the surgeon when the arm was supported on plexiglass versus graphite. CONCLUSION: The C-arm positioned in the standard fashion exposes the surgeon to less damaging radiation. Therefore, when the surgeon is standing, we recommend using the C-arm in the standard position. CLINICAL RELEVANCE: Orthopaedic surgeons who stand should use the C-arm in the standard position to pin supracondylar humerus fractures to lower the risk of ionizing radiation exposure.


Assuntos
Grafite , Fraturas do Úmero , Exposição à Radiação , Cirurgiões , Criança , Humanos , Polimetil Metacrilato , Fraturas do Úmero/cirurgia , Úmero/cirurgia , Exposição à Radiação/prevenção & controle , Pinos Ortopédicos
3.
J Vasc Interv Radiol ; 34(4): 544-555.e11, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36379286

RESUMO

PURPOSE: To update normative data on fluoroscopy dose indices in the United States for the first time since the Radiation Doses in Interventional Radiology study in the late 1990s. MATERIALS AND METHODS: The Dose Index Registry-Fluoroscopy pilot study collected data from March 2018 through December 2019, with 50 fluoroscopes from 10 sites submitting data. Primary radiation dose indices including fluoroscopy time (FT), cumulative air kerma (Ka,r), and kerma area product (PKA) were collected for interventional radiology fluoroscopically guided interventional (FGI) procedures. Clinical facility procedure names were mapped to the American College of Radiology (ACR) common procedure lexicon. Distribution parameters including the 10th, 25th, 50th, 75th, 95th, and 99th percentiles were computed. RESULTS: Dose indices were collected for 70,377 FGI procedures, with 50,501 ultimately eligible for analysis. Distribution parameters are reported for 100 ACR Common IDs. FT in minutes, Ka,r in mGy, and PKA in Gy-cm2 are reported in this study as (n; median) for select ACR Common IDs: inferior vena cava filter insertion (1,726; FT: 2.9; Ka,r: 55.8; PKA: 14.19); inferior vena cava filter removal (464; FT: 5.7; Ka,r: 178.6; PKA: 34.73); nephrostomy placement (2,037; FT: 4.1; Ka,r: 39.2; PKA: 6.61); percutaneous biliary drainage (952; FT: 12.4; Ka,r: 160.5; PKA: 21.32); gastrostomy placement (1,643; FT: 3.2; Ka,r: 29.1; PKA: 7.29); and transjugular intrahepatic portosystemic shunt placement (327; FT: 34.8; Ka,r: 813.0; PKA: 181.47). CONCLUSIONS: The ACR DIR-Fluoro pilot has provided state-of-the-practice statistics for radiation dose indices from IR FGI procedures. These data can be used to prioritize procedures for radiation optimization, as demonstrated in this work.


Assuntos
Radiografia Intervencionista , Radiologia Intervencionista , Humanos , Doses de Radiação , Projetos Piloto , Fluoroscopia , Radiologia Intervencionista/métodos , Sistema de Registros , Radiografia Intervencionista/efeitos adversos
4.
J Vasc Interv Radiol ; 34(4): 556-562.e3, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36031041

RESUMO

PURPOSE: To compare radiation dose index distributions for fluoroscopically guided interventions in interventional radiology from the American College of Radiology (ACR) Fluoroscopy Dose Index Registry (DIR-Fluoro) pilot to those from the Radiation Doses in Interventional Radiology (RAD-IR) study. MATERIALS AND METHODS: Individual and grouped ACR Common identification numbers (procedure types) from the DIR-Fluoro pilot were matched to procedure types in the RAD-IR study. Fifteen comparisons were made. Distribution parameters, including the 10th, 25th, 50th, 75th, and 95th percentiles, were compared for fluoroscopy time (FT), cumulative air kerma (Ka,r), and kerma area product (PKA). Two derived indices were computed using median dose indices. The procedure-averaged reference air kerma rate (Ka,r¯) was computed as Ka,r / FT. The procedure-averaged x-ray field size at the reference point (Ar) was computed as PKA / (Ka,r × 1,000). RESULTS: The median FT was equally likely to be higher or lower in the DIR-Fluoro pilot as it was in the RAD-IR study, whereas the maximum FT was almost twice as likely to be higher in the DIR-Fluoro pilot than it was in the RAD-IR study. The median Ka,r was lower in the DIR-Fluoro pilot for all procedures, as was median PKA. The maximum Ka,r and PKA were more often higher in the DIR-Fluoro pilot than in the RAD-IR study. Ka,r¯ followed the same pattern as Ka,r, whereas Ar was often greater in DIR-Fluoro. CONCLUSIONS: The median dose indices have decreased since the RAD-IR study. The typical Ka,r rates are lower, a result of the use of lower default dose rates. However, opportunities for quality improvement exist, including renewed focus on tight collimation of the imaging field of view.


Assuntos
Radiografia Intervencionista , Radiologia Intervencionista , Humanos , Radiologia Intervencionista/métodos , Doses de Radiação , Fluoroscopia , Radiografia Intervencionista/efeitos adversos , Sistema de Registros
5.
Med Phys ; 49(4): e1-e49, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35032394

RESUMO

Modern fluoroscopes used for image guidance have become quite complex. Adding to this complexity are the many regulatory and accreditation requirements that must be fulfilled during acceptance testing of a new unit. Further, some of these acceptance tests have pass/fail criteria, whereas others do not, making acceptance testing a subjective and time-consuming task. The AAPM Task Group 272 Report spells out the details of tests that are required and gives visibility to some of the tests that while not yet required are recommended as good practice. The organization of the report begins with the most complicated fluoroscopes used in interventional radiology or cardiology and continues with general fluoroscopy and mobile C-arms. Finally, the appendices of the report provide useful information, an example report form and topics that needed their own section due to the level of detail.


Assuntos
Cardiologia , Radiologia Intervencionista , Fluoroscopia/métodos , Doses de Radiação , Radiologia Intervencionista/métodos , Relatório de Pesquisa
7.
J Vasc Interv Radiol ; 31(10): 1545-1550.e1, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32861568

RESUMO

PURPOSE: To characterize the accuracy and consistency of fluoroscope dose index reporting and report rates of occupational radiation safety hardware availability and use, trainee participation in procedures, and optional hardware availability at pilot sites for the American College of Radiology (ACR) Fluoroscopy Dose Index Registry (DIR). MATERIALS AND METHODS: Nine institutions participated in the registry pilot, providing fluoroscopic technical and clinical practice data from 38 angiographic C-arm-type fluoroscopes. These data included measurements of the procedure table and mattress transmission factors and accuracy measurements of the reference-point air kerma (Ka,r) and air kerma-area product (PKA). The accuracy of the radiation dose indices were analyzed for variation over time by 1-way analysis of variance (ANOVA). Sites also self-reported information on availability and use of radiation safety hardware, hardware configuration of fluoroscopes, and trainee participation in procedures. RESULTS: All Ka,r and PKA measurements were within the ±35% regulatory limit on accuracy. The mean absolute difference between correction factors for a given system in fluoroscopic and acquisition mode was 0.03 (95% confidence interval, 0.03-0.03). For the 28 fluoroscopic imaging planes that provided data for 3 time points, ANOVA yielded an F value of 0.134 with an F-critical value of 3.109 (P = .875). CONCLUSIONS: This publication provides the technical and clinical framework pertaining to the ACR Fluoroscopy DIR pilot and offers necessary context for future analysis of the clinical procedure radiation-dose data collected.


Assuntos
Exposição Ocupacional , Doses de Radiação , Exposição à Radiação , Monitoramento de Radiação , Radiografia Intervencionista , Fluoroscopia , Humanos , Exposição Ocupacional/efeitos adversos , Saúde Ocupacional , Projetos Piloto , Exposição à Radiação/efeitos adversos , Radiografia Intervencionista/efeitos adversos , Sistema de Registros , Medição de Risco , Fatores de Risco , Espalhamento de Radiação , Estados Unidos
8.
J Appl Clin Med Phys ; 20(3): 115-124, 2019 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-30861278

RESUMO

The Quality assurance of ultrasound clinical imaging systems is essential for maintaining their performance to the highest level and for complying with the requirements by various regulatory and accrediting agencies. Although there is no standardization yet, most of the quality assessment procedures available in literature are proposed for B-mode and Doppler imaging. However, ultrasound imaging systems offer a variety of advanced imaging modes, besides B-mode and Doppler, which are primarily aimed at improving image quality. This study presents computer-based methods for evaluating image quality for the advanced imaging modes of ultrasound imaging systems: harmonic imaging, spatial compounding imaging, adaptive speckle reduction, and tissue aberration correction. The functions and parameters proposed for evaluating image quality are: grayscale mapping function, image contrast, contrast-to-noise ratio (CNR), and high-contrast spatial resolution. We present our computer-based methods for evaluating image quality of these modes with a number of probe and scanner combinations, which were employed to image targets in ultrasound phantoms. The functions and parameters here proposed in image quality performance evaluation are: grayscale mapping function, image contrast, CNR, and high-contrast spatial resolution. We show that these quantities could be useful in developing standardized methods for evaluating the advanced ultrasound imaging modes, especially when the advanced mode resulted in subtle visual differences.


Assuntos
Algoritmos , Processamento de Imagem Assistida por Computador/métodos , Imagens de Fantasmas , Razão Sinal-Ruído , Ultrassonografia/métodos , Ultrassonografia/normas , Humanos
9.
J Pediatr Urol ; 14(4): 334.e1-334.e8, 2018 08.
Artigo em Inglês | MEDLINE | ID: mdl-30257794

RESUMO

BACKGROUND: Fluoroscopy is commonly used during pediatric ureteroscopy (PURS) for urolithiasis, and the most important contributor to overall radiation exposure is fluoroscopy time (FT). One factor that may impact FT is who controls activation of the fluoroscope: the urologist (with a foot pedal) or the radiation technologist (as directed by the urologist). While there are plausible reasons to believe that either approach may lead to reduced FT, there are no systematic investigations of this question. We sought to compare FT with surgeon-control versus technologist control during PURS for urolithiasis. METHODS: We conducted a randomized controlled trial (Clinicaltrials.gov ID number: NCT02224287). Institutional Review Board approval was sought and obtained for this study. All subjects (or their legal guardians) provided informed consent. Each patient (age 5-26 years) was randomized to surgeon- or technologist-controlled fluoroscope activation. Block randomization was stratified by the surgeon. For technologist control, the surgeon verbally directed the technologist to activate the fluoroscope. For surgeon control, a foot pedal was used by the surgeon. The technologist controlled c-arm positioning, settings, and movement. The primary outcome was total FT for the procedure. Secondary outcomes included radiation exposure (entrance surface air kerma [ESAK] mGy). We also analyzed clinical and procedural predictors of FT and exposure. Mixed linear models accounting for clustering by surgeon were developed. RESULTS: Seventy-three procedures (5 surgeons) were included. The number of procedures per surgeon ranged from seven to 36. Forty-three percent were pre-stented. Thirty-one procedures were left side, 35 were right side, and seven were bilateral. Stones were treated in 71% of procedures (21% laser, 14% basket, and 65% laser/basket). Stone locations were distal ureter (11.5%), proximal/mid-ureter (8%), renal (69%), and ureteral/renal (11.5%). An access sheath was used in 77%. Median stone size was 8.0 mm (range 2.0-20.0). Median FT in the surgeon control group was 0.5 min (range 0.01-6.10) versus 0.55 min (range 0.10-5.50) in the technologist-control group (p = 0.284). Median ESAK in the surgeon control group was 46.02 mGy (range 5.44-3236.80) versus 46.99 mGy (range: 0.17-1039.31) in the technologist-control group (p = 0.362). Other factors associated with lower FT on univariate analysis included female sex (p = 0.015), no prior urologic surgeries (p = 0.041), shorter surgery (p = 0.011), and no access sheath (p = 0.006). On multivariable analysis only female sex (p = 0.017) and no access sheath (p = 0.049) remained significant. There was significant variation among surgeons (p < 0.0001); individual surgeon median FT ranged from 0.40 to 2.95 min. CONCLUSIONS: Fluoroscopy time and radiation exposure are similar whether the surgeon or technologist controls fluoroscope activation. Other strategies to reduce exposure might focus on surgeon-specific factors, given the significant variation between surgeons.


Assuntos
Fluoroscopia/normas , Pessoal de Laboratório Médico , Exposição Ocupacional/estatística & dados numéricos , Exposição à Radiação/estatística & dados numéricos , Ureteroscopia , Urologia , Adolescente , Adulto , Criança , Pré-Escolar , Feminino , Humanos , Masculino , Adulto Jovem
11.
Med Phys ; 42(12): 6815-29, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26632039

RESUMO

Due to the proliferation of disciplines employing fluoroscopy as their primary imaging tool and the prolonged extensive use of fluoroscopy in interventional and cardiovascular angiography procedures, "dose-area-product" (DAP) meters were installed to monitor and record the radiation dose delivered to patients. In some cases, the radiation dose or the output value is calculated, rather than measured, using the pertinent radiological parameters and geometrical information. The AAPM Task Group 190 (TG-190) was established to evaluate the accuracy of the DAP meter in 2008. Since then, the term "DAP-meter" has been revised to air kerma-area product (KAP) meter. The charge of TG 190 (Accuracy and Calibration of Integrated Radiation Output Indicators in Diagnostic Radiology) has also been realigned to investigate the "Accuracy and Calibration of Integrated Radiation Output Indicators" which is reflected in the title of the task group, to include situations where the KAP may be acquired with or without the presence of a physical "meter." To accomplish this goal, validation test protocols were developed to compare the displayed radiation output value to an external measurement. These test protocols were applied to a number of clinical systems to collect information on the accuracy of dose display values in the field.


Assuntos
Fluoroscopia/instrumentação , Fluoroscopia/métodos , Doses de Radiação , Radiometria/normas , Calibragem , Humanos , Radiometria/instrumentação , Radiometria/métodos , Reprodutibilidade dos Testes
12.
Oncol Rep ; 33(5): 2299-308, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-25813246

RESUMO

The effects of histone deacetylase (HDAC) inhibitors on epithelial-mesenchymal transition (EMT) differ in various types of cancers. We investigated the EMT phenotype in four colon cancer cell lines when challenged with HDAC inhibitors trichostatin A (TSA) and valproic acid (VPA) with or without transforming growth factor-ß1 (TGF-ß1) treatment. Four colon cancer cell lines with different phenotypes in regards to tumorigenicity, microsatellite stability and DNA mutation were used. EMT phenotypes were assessed by the expression of E-cadherin and vimentin using western blot analysis, immunofluorescence, quantitative real-time RT-PCR following treatment with TSA (100 or 200 nM) or VPA (0.5 mM) with or without TGF-ß1 (5 ng/ml) for 24 h. Biological EMT phenotypes were also evaluated by cell morphology, migration and invasion assays. TSA or VPA induced mesenchymal features in the colon carcinoma cells by a decrease in E-cadherin and an increase in vimentin expression at the mRNA and protein levels. Confocal microscopy revealed membranous attenuation or nuclear translocation of E-cadherin and enhanced expression of vimentin. These responses occurred after 6 h and increased until 24 h. Colon cancer cells changed from a round or rectangular shape to a spindle shape with increased migration and invasion ability following TSA or VPA treatment. The susceptibility to EMT changes induced by TSA or VPA was comparable in microsatellite stable (SW480 and HT29) and microsatellite unstable cells (DLD1 and HCT116). TSA or VPA induced a mesenchymal phenotype in the colon carcinoma cells and these effects were augmented in the presence of TGF-ß1. HDAC inhibitors require careful caution before their application as new anticancer drugs for colon cancers.


Assuntos
Carcinoma/metabolismo , Neoplasias do Colo/metabolismo , Transição Epitelial-Mesenquimal/efeitos dos fármacos , Inibidores de Histona Desacetilases/farmacologia , Ácidos Hidroxâmicos/farmacologia , RNA Mensageiro/efeitos dos fármacos , Fator de Crescimento Transformador beta1/farmacologia , Ácido Valproico/farmacologia , Caderinas/efeitos dos fármacos , Caderinas/genética , Caderinas/metabolismo , Carcinoma/patologia , Movimento Celular , Neoplasias do Colo/patologia , Células HCT116 , Células HT29 , Humanos , Microscopia Confocal , Invasividade Neoplásica , Fenótipo , RNA Mensageiro/metabolismo , Reação em Cadeia da Polimerase Via Transcriptase Reversa , Vimentina/efeitos dos fármacos , Vimentina/genética , Vimentina/metabolismo
13.
Korean J Parasitol ; 44(1): 15-20, 2006 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-16514277

RESUMO

Free-living amoebae of the genus Acanthamoeba are causative agents of granulomatous amebic encephalitis and amebic keratitis. Because the virulence of Acanthamoeba culbertsoni cultured in the laboratory is restored by consecutive brain passages, we examined the genes induced in mouse brain-passaged A. culbertsoni by differential display reverse transcriptase polymerase chain reaction (DDRT-PCR). Enhanced A. culbertsoni virulence was observed during the second mouse brain passage, i.e., infected mouse mortality increased from 5% to 70%. Ten cDNAs induced during mouse brain passage were identified by DDRT-PCR and this was confirmed by northern blot analysis. BlastX searches of these cDNAs indicated the upregulations of genes encoding predictive NADH-dehydrogenase, proteasomal ATPase, and GDP-mannose pyrophosphorylase B, which have previously been reported to be associated with A. culbertsoni virulence factors.


Assuntos
Acanthamoeba/genética , Acanthamoeba/patogenicidade , Amebíase/parasitologia , DNA de Protozoário/fisiologia , Regulação da Expressão Gênica , Amebíase/mortalidade , Animais , Northern Blotting/métodos , Encéfalo/parasitologia , Clonagem Molecular/métodos , DNA Complementar/biossíntese , DNA de Protozoário/biossíntese , Perfilação da Expressão Gênica/métodos , Genes de Protozoários/genética , Camundongos , Camundongos Endogâmicos ICR , Dados de Sequência Molecular , Reação em Cadeia da Polimerase Via Transcriptase Reversa/métodos , Inoculações Seriadas , Regulação para Cima , Virulência/genética
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA