Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Arch Craniofac Surg ; 19(4): 264-269, 2018 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-30332891

RESUMO

BACKGROUND: Orbital resorbable mesh plates are adequate to use for isolated floor and medial wall fractures with an intact bony buttress, but are not recommended to use for large orbital wall fractures that need load bearing support. The author previously reported an orbital wall restoring surgery that restored the orbital floor to its prior position through the transnasal approach and maintained temporary extraorbital support with a balloon in the maxillary sinus. Extraorbital support could reduce the load applied on the orbital implants in orbital wall restoring surgery and the use of resorbable implants was considered appropriate for the author's orbital wall restoring technique. METHODS: A retrospective review was conducted of 31 patients with pure unilateral orbital floor fractures between May 2014 and May 2018. The patients underwent transnasal restoration of the orbital floor through insertion of a resorbable mesh plate and maintenance of temporary balloon support. The surgical results were evaluated by the Hertel scale and a comparison of preoperative and postoperative orbital volume ratio (OVR) values. RESULTS: The OVR decreased significantly, by an average of 6.01% (p< 0.05) and the preoperative and postoperative Hertel scale measurements decreased by an average of 0.34 mm with statistical significance (p< 0.05). No complications such as buckling or sagging of the implant occurred among the 31 patients. CONCLUSION: The use of resorbable mesh plate in orbital floor restoration surgery is an effective and safe technique that can reduce implant deformation or complications deriving from the residual permanent implant.

2.
Arch Plast Surg ; 42(6): 769-75, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26618126

RESUMO

BACKGROUND: The radial forearm flap is a versatile, widely used flap. However, the possibility of donor site complications has led to concern over its use. Some surgeons prefer using other flaps whose donor sites can be closed primarily with less morbidity, including avoiding unpleasant scarring. However, in our experience, donor site stability of the radial forearm flap can be reliably achieved by using well-implemented specific procedures. Here, we present a collection of donor site cases of the radial forearm flap and investigate factors that affect the aesthetic results as the basis for a reference for selecting a radial forearm flap. METHODS: In this retrospective study, we reviewed 171 cases in which a radial forearm flap was used for free tissue transfer after resecting head and neck cancer. We focused on donor site morbidity rates. Each operation involved a detailed procedure designed to minimize donor site morbidity. Moreover, statistical investigations were conducted for 22 cases to determine factors affecting the scar appearance. RESULTS: Only one case developed total skin graft necrosis as a major complication. Scar-related aesthetic results were acceptable, and the body-mass index, body weight, diabetes, and cardiac problems were significant factors related to the appearance of scars. CONCLUSIONS: Performing the radial forearm flap using a well-implemented detailed technique helps achieve acceptable donor site morbidity results. The aesthetic results were more promising for patients without excess body weight, diabetes, or cardiac problems. Therefore, anxiety about donor site morbidity should not be a reason to avoid selecting the radial forearm flap in suitable patients.

3.
Arch Plast Surg ; 42(5): 601-7, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26430632

RESUMO

BACKGROUND: Autologous or implant-based breast reconstruction after nipple-sparing mastectomy is increasingly preferred worldwide as a breast cancer treatment option. However, postoperative nipple-areola complex (NAC) necrosis is the most significant complication of nipple-sparing mastectomy. The purpose of our study was to identify the risk factors for NAC necrosis, and to describe the use of our skin-banking technique as a solution. METHODS: We reviewed cases of immediate autologous breast reconstruction after nipple-sparing mastectomy at our institution between June 2005 and January 2014. The patients' data were reviewed and the risk of NAC necrosis was analyzed based on correlations between patient variables and NAC necrosis. Moreover, data pertaining to five high-risk patients who underwent the donor skin-banking procedure were included in the analysis. RESULTS: Eighty-five patients underwent immediate autologous breast reconstruction after nipple-sparing mastectomy during the study period. Partial or total NAC necrosis occurred in 36 patients (43.4%). Univariate analysis and binary regression modeling found that body mass index, smoking history, radiation therapy, and mastectomy volume were significantly associated with NAC necrosis. Of the 36 cases of NAC necrosis, 31 were resolved with dressing changes, debridement, or skin grafting. The other five high-risk patients underwent our prophylactic skin-banking technique during breast reconstruction surgery. CONCLUSIONS: NAC necrosis is common in patients with multiple risk factors. The use of the skin-banking technique in immediate autologous breast reconstruction is an attractive option for high-risk patients. Banked skin can be used in such cases without requiring additional donor tissue, with good results in terms of aesthetic and reconstructive outcomes.

4.
J Plast Reconstr Aesthet Surg ; 68(7): 966-72, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25886882

RESUMO

BACKGROUND: A robotic surgery technique of harvesting the latissimus dorsi muscle flap has technical advantages over endoscopic harvest and cosmetic advantages over the open technique. The authors introduce a new transaxillary gasless technique using an articulated long retractor for robot assisted latissimus dorsi flap harvest. METHODS: Twelve robot assisted latissimus dorsi muscle flaps were harvested: 3 cases of delayed reconstruction following tissue expander insertion or breast conserving surgery; 4 cases of immediate reconstruction following nipple-sparing mastectomy; and 5 cases of chest wall deformity correction in patients with Poland syndrome. A specially designed articulated long retractor was used to maintain adequate working space and enable latissimus dorsi muscle dissection without gas insufflation. RESULTS: Twelve muscle flaps were successfully harvested in 12 patients without converting to an open technique. The mean docking time was 54.6 min, and the mean operative time and robotic time were 400.4 min and 85.8 min, respectively. There were no donor site complications or flap problems. Average follow-up was 15.7 months. All patients were satisfied with their esthetic results, especially the absence of visible scars. CONCLUSION: The novel robot assisted latissimus dorsi harvest technique is a safe alternative to the conventional method.


Assuntos
Mamoplastia/métodos , Mastectomia/métodos , Robótica/instrumentação , Robótica/métodos , Músculos Superficiais do Dorso/cirurgia , Retalhos Cirúrgicos , Coleta de Tecidos e Órgãos/métodos , Adulto , Implantes de Mama , Neoplasias da Mama/cirurgia , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Duração da Cirurgia , Satisfação do Paciente , Síndrome de Poland/cirurgia , Estudos Retrospectivos , Parede Torácica/cirurgia , Adulto Jovem
5.
Arch Craniofac Surg ; 16(3): 125-130, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28913237

RESUMO

BACKGROUND: Poly-L-lactide materials combined with hydroxyapatite (u-HA /PLLA) have been developed to overcome the drawbacks of absorbable materials, such as radiolucency and comparably less implant strength. This study was designed to evaluate the usefulness of u-HA/PLLA material in the repair of orbital medial wall defects. METHODS: This study included 10 patients with pure medial wall blow-out fractures. The plain radiographs were taken preoperatively, immediately after, and 2 months after surgery. The computed tomography scans were performed preoperatively and 2 months after surgery. Patients were evaluated for ease of manipulation, implant immobility, rigidity and complications with radiologic studies. RESULTS: None of the patients had postoperative complications, such as infection or enophthalmos. The u-HA/PLLA implants had adequate rigidity, durability, and stable position on follow-up radiographic studies. On average, implants were thawed 3.4 times and required 14 minutes of handling time. CONCLUSION: The u-HA/PLLA implants are safe and reliable for reconstruction of orbital medial wall in terms of rigidity, immobility, radiopacity, and cost-effectiveness. These thin yet rigid implants can be useful where wide periosteal dissection is difficult due to defect location or size. Since the u-HA/PLLA material is difficult to manipulate, these implants are not suitable for use in complex 3-dimensional defects.

6.
Ann Plast Surg ; 75(5): 539-42, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-24691310

RESUMO

BACKGROUND: This study was designed to introduce free toe soft tissue transfer using local infiltration anesthesia in patients not suitable for general anesthesia and local tissue coverage. METHODS: From January 2006 to August 2012, a total of 11 traumatic fingertip defects were reconstructed by toe soft tissue transfer. All procedures except 1 were done as primary reconstructions, with either the lateral side of the great toe (5 cases) or the medial side of the second toe (6 cases) used as a donor. Postoperative follow-up periods were between 8 months to 2 years and 6 months. RESULTS: Flap sizes varied from 1.0 × 2.0 to 2.0 × 3.5 cm. The mean operative times were 4 hours 29 minutes for cases done by a single team and 3 hours 21 minutes for cases done by a 2-team approach. Approximately 5.8 mL of local anesthetic agent was used in each finger and 5.9 mL was used in the toes for a total of 11.7 mL. All flaps survived and were fully taken without complications, except 1 case that presented partial necrosis. CONCLUSIONS: Fingertip soft tissue reconstruction by free toe tissue transfer under local anesthesia uses a more limited operative field, with a shorter operative time, enabling reconstruction in patients not suitable for general anesthesia. This is even more so with a microsurgical 2-team approach, which reduces the volume of anesthetic agent needed, making this method a sufficiently realistic option for fingertip soft tissue reconstruction.


Assuntos
Anestesia Local , Traumatismos dos Dedos/cirurgia , Retalhos de Tecido Biológico/transplante , Procedimentos de Cirurgia Plástica/métodos , Dedos do Pé/transplante , Adulto , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento
7.
Arch Plast Surg ; 41(6): 722-7, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25396186

RESUMO

BACKGROUND: Perineal reconstruction following pelvic exenteration is a challenging area in plastic surgery. Its advantages include preventing complications by obliterating the pelvic dead space and minimizing the scar by using the previous abdominal incision and a vertical rectus abdominis musculocutaneous (VRAM) flap. However, only a few studies have compared the complications and the outcomes following pelvic exenteration between cases with and without a VRAM flap. In this study, we aimed to compare the complications and the outcomes following pelvic exenteration with or without VRAM flap coverage. METHODS: We retrospectively reviewed the cases of nine patients for whom transpelvic VRAM flaps were created following pelvic exenteration due to pelvic malignancy. The complications and outcomes in these patients were compared with those of another nine patients who did not undergo such reconstruction. RESULTS: Flap reconstruction was successful in eight cases, with minor complications such as wound infection and dehiscence. In all cases in the reconstructed group (n=9), structural integrity was maintained and major complications including bowel obstruction and infection were prevented by obliterating the pelvic dead space. In contrast, in the control group (n=9), peritonitis and bowel obstruction occurred in 1 case (11%). CONCLUSIONS: Despite the possibility of flap failure and minor complications, a VRAM flap can result in adequate perineal reconstruction to prevent major complications of pelvic exenteration.

8.
J Wound Ostomy Continence Nurs ; 41(5): 430-5, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25188799

RESUMO

PURPOSE: Transcutaneous partial oxygen tension (TcpO2) is considered the gold standard for assessment of tissue oxygenation, which is an essential factor for wound healing. The purpose of this study was to evaluate the association between macrocirculation and TcpO2 in persons with diabetes mellitus. SUBJECTS AND SETTING: Ninety-eight patients with diabetic foot ulcers participated in the study (61 men and 37 women). The subjects had a mean age of 66.6 years (range, 30-83 years) and were treated at the Diabetic Wound Center of Korea University Guro Hospital, Seoul, Republic of Korea. METHODS: Macrocirculation was evaluated using 2 techniques: computed tomographic angiography and Doppler ultrasound. Macrocirculation scores were based on the patency of the two tibial arteries in 98 patients. Computed tomographic angiography and Doppler ultrasound scores (0-4 points) were given according to intraluminal filling defects and arterial pulse waveform of each vessel, respectively. Tissue oxygenation was measured by TcpO2. Macrocirculation scores were statistically analyzed as a function of the TcpO2. RESULTS: Statistical analysis revealed no significant linear trend between the macrocirculation status and TcpO2. Biavariate analysis using the Fisher exact test, Mantel-Haenszel tests, and McNemar-Bowker tests also found no significant relationship between macrocirculation and TcpO2. CONCLUSIONS: Computed tomographic angiography and Doppler ultrasound are not sufficiently reliable substitutes for TcpO2 measurements in regard to determining the optimal treatment for diabetic patients.


Assuntos
Monitorização Transcutânea dos Gases Sanguíneos/métodos , Pé Diabético/mortalidade , Pé/irrigação sanguínea , Valor Preditivo dos Testes , Sobrevivência de Tecidos/fisiologia , Cicatrização/fisiologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Monitorização Transcutânea dos Gases Sanguíneos/normas , Pé Diabético/complicações , Pé Diabético/terapia , Feminino , Pé/fisiologia , Humanos , Masculino , Pessoa de Meia-Idade
9.
Arch Craniofac Surg ; 15(2): 75-81, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28913195

RESUMO

BACKGROUND: The fibular free flap has been used as the standard methods of segmental mandibular reconstruction. The objective of mandibular reconstruction not only includes restored continuity of the mandible but also the recovery of optimal function. This paper emphasizes the advantage of the fibular free flap reconstruction over that of locking mandibular reconstruction plate fixation. METHODS: The hospital charts of all patients (n=20) who had a mandibular reconstruction between 1994 and 2013 were retrospectively reviewed. Eight patients had plate-only fixation of the mandible, and the remaining 12 had vascularized fibular free flap reconstruction. Complications and outcomes were reviewed and compared between the 2 groups via statistical analysis. RESULTS: Overall complication rates were significantly lower in the fibular flap group (8.3%) than in the plate fixation group (87.5%; p =0.001). Most (7/8) patients in the plate fixation group had experienced plate-related late complications, including plate fracture or exposure. In the fibular flap group, no complications were observed, except for a single case of donor-site wound dehiscence (1/12). CONCLUSION: The fibular free flap provides a more stable support and additional soft tissue support for the plate, thereby minimizing the risk of plate-related complications. Fibular free flap is the most reliable option for mandibular reconstruction, and we believe that the flap should be performed primarily whenever possible.

10.
Dermatol Surg ; 35(9): 1342-8, 2009 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-19500128

RESUMO

BACKGROUND AND OBJECTIVE: Various types of allogenic skin substitutes composed of cryopreserved keratinocytes, fibroblasts, or both have been used for treatments of diabetic foot ulcers, but the effects have generally not been dramatic because cryopreservation impairs cell activities. The purpose of the study was to evaluate the use of non-cryopreserved fresh human fibroblast allografts in treating diabetic foot ulcers. MATERIALS AND METHODS: Human dermal fibroblasts from healthy teenagers were cultured and applied over the foot ulcers of 37 patients with diabetes. Control treatment was performed in 18 patients. Eight weeks after treatment, the percentages of complete healing, mean healing times, and patient satisfaction were compared, with follow-up ranging from 6 to 40 months. RESULTS: Our study showed that 83.8% of the treated group and 50.0% of the control group experienced complete healing. The times required for complete healing were 30.9+/-10.1 and 47.2+/-7.8 days in the treated and control groups, respectively. Patient satisfaction with fresh fibroblast treatment was also superior to satisfaction with the conventional method (mean scores: 8.0+/-1.0 and 4.9+/-1.4, respectively). No adverse events related to the study treatment occurred. CONCLUSION: The use of fresh human fibroblast allografts was found to be a safe and effective treatment for diabetic foot ulcers. The authors have indicated no significant interest with commercial supporters.


Assuntos
Pé Diabético/cirurgia , Fibroblastos/transplante , Transplante de Pele/métodos , Adolescente , Pé Diabético/patologia , Feminino , Fibroblastos/citologia , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Satisfação do Paciente , Estudos Retrospectivos , Transplante Homólogo , Resultado do Tratamento , Cicatrização
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA