Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 18 de 18
Filtrar
1.
J Yeungnam Med Sci ; 41(1): 4-12, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37157781

RESUMO

Biomaterials have been used to supplement and restore function and structure by replacing or restoring parts of damaged tissues and organs. In ancient times, the medical use of biomaterials was limited owing to infection during surgery and poor surgical techniques. However, in modern times, the medical applications of biomaterials are diversifying owing to great developments in material science and medical technology. In this paper, we introduce biomaterials, focusing on calcium phosphate ceramics, including octacalcium phosphate, which has recently attracted attention as a bone graft material.

2.
Biomedicines ; 11(3)2023 Mar 05.
Artigo em Inglês | MEDLINE | ID: mdl-36979764

RESUMO

Bioceramics are calcium-phosphate-based materials used in medical and dental implants for replacing or repairing damaged bone tissues; however, the effect of bioceramic sintering on the intracellular signaling pathways remains unknown. In order to address this, we analyzed the impact of sintering on the cell signaling pathways of osteoblast cells using sintered and non-sintered hydroxyapatite (HA) and beta-tricalcium phosphate (ß-TCP). X-ray diffraction indicated that only the morphology of HA was affected by sintering; however, the sintered bioceramics were found to have elevated the calcium concentrations in relation to the non-sintered variants. Both bioceramics inhibited the JNK signaling pathway; the sintered HA exhibited half the value of the non-sintered variant, while the sintered ß-TCP rarely expressed a p-JNK value. The total Src and Raptor protein concentrations were unaffected by the sintering, while the p-Src concentrations were decreased. The p-EGFR signaling pathway was regulated by the non-sintered bioceramics, while the p-p38 concentrations were reduced by both the sintered ß-TCP and HA. All of the bioceramics attenuated the total AKT concentrations, particularly the non-sintered HA, and the AKT phosphorylation concentration, except for the non-sintered ß-TCP. Thus, the sintering of bioceramics affects several intracellular signaling pathways. These findings may elucidate the bioceramic function and expand their application scope as novel substrates in clinical applications.

3.
J Orthop Translat ; 37: 100-112, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-36262961

RESUMO

Background: The osteogenic capabilities and biodegradability of octacalcium phosphate (OCP) composites make them unique. Despite the excellent characteristics of OCP, their use is limited due to handling difficulties. In this study, we aimed to evaluate and compare three types of OCPs (cemented OCP (C-OCP), C-OCP with collagen (OCP/Col), and synthetic OCP (S-OCP) with alginate (OCP/Alg)) versus commercially available ß-tricalcium phosphate (ß-TCP) regarding their potential to accelerate bone formation in defective rat tibias. Methods: The specimens with OCP composite were manufactured into 5 â€‹mm cubes and inserted into the segmental defects of rat tibias fixed with an external fixator. In addition, 3 â€‹mm-hole defects in rat tibias were evaluated to compare the graft material properties in different clinical situations. Serial X-ray studies were evaluated weekly and the tibias were harvested at postoperative 6 weeks or 8 weeks for radiologic evaluation. Histological and histomorphometric analyses were performed to evaluate the acceleration of bone formation. Results: In the critical-defect model, OCP/Alg showed bone bridges between segmentally resected bone ends that were comparable to those of ß-TCP. However, differences were observed in the residual graft materials. Most ß-TCP was maintained until 8 weeks postoperatively; however, OCP/Alg was more biodegradable. In addition calcification in the ß-TCP occurred at the directly contacted area between graft particles and bony ingrowth was observed in the region adjacent resected surface of tibia. In contrast, no direct bony ingrowth was observed in OCP-based materials, but osteogenesis induced from resected surface of tibia was more active. In the hole-defect model, OCP/Col accelerated bone formation. ß-TCP and OCP/Alg showed similar patterns with relatively higher biodegradability. In histology, among the OCP-based materials, directly contacted new bone was formed only in OCP/Alg group. The new bone formation in the periphery area of graft materials was much more active in the OCP-based materials, and the newly formed bone showed a thicker trabecular and more mature appearance than the ß-TCP group. Conclusions: In this study, OCP/Alg was equivalent to ß-TCP in the acceleration of bone formation with better biodegradability appropriate for clinical situations in different circumstances. Our OCP/Col composite showed fast degradation, which makes it unsuitable for use in mechanical stress conditions in clinical orthopedic settings. The Translational Potential of this Article: In our research, we compared our various manufactured OCP composites to commercially available ß-TCP in critical-defect rat tibia model. OCP/Col showed acceleration in hole-defect model as previous studies in dental field but in our critical-sized defect model it resorbed fast without acceleration of bony union. OCP/Alg showed matched results compared to ß-TCP and relatively fast resorption so we showed market value in special clinical indication depending on treatment strategy. This is the first OCP composite study in orthopaedics with animal critical-sized tibia bone study and further study should be considered for clinical application based on this study.

4.
Int J Med Sci ; 19(12): 1724-1731, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36313230

RESUMO

Octacalcium phosphate (OCP), a type of bioactive ceramics, may be associated with dentine, tooth apatite, and especially bone generation, and promotes wound healing after fracture. Recently, commercial bone grafting products containing a large amount of OCP material have been released because OCP can be synthesized in large quantities. It is reported to increase cell proliferation, but the interaction between OCP and cell signaling pathways is still unclear. In this study, first, we demonstrated OCP mediated cell signaling pathways with only purified OCP materials. OCP regulated P38, JNK (c-Jun N-terminal kinase), Src, and AKT (protein kinase B) signaling pathways. OCP crystals appeared in the characteristic ribbon shape but varied by several tens of micrometers in size. The X-ray diffraction pattern was the same as previously reported. We studied two concentrations of OCP (10 mg/ml and 20 mg/ml) to understand whether the effect of OCP on cell signaling pathways is dose dependent. We confirmed that OCP treatment affected cell proliferation and alkaline phosphatase and disrupted Src phosphorylation but did not change the total protein level. P38 phosphorylation was activated with OCP treatment and inhibited by SB203580, but P38 total protein level did not change. OCP inhibited JNK phosphorylation signaling, whereas PD98509 inhibited JNK phosphorylation with or without OCP. Interestingly, the AKT total level decreased after OCP treatment, but AKT phosphorylation increased considerably. Our results demonstrate that OCP materials modulate cell signaling pathways and increase cell proliferation.


Assuntos
Fosfatos de Cálcio , Proteínas Proto-Oncogênicas c-akt , Proteínas Proto-Oncogênicas c-akt/metabolismo , Diferenciação Celular , Fosfatos de Cálcio/farmacologia , Fosfatos de Cálcio/química , Osteoblastos/metabolismo , Transdução de Sinais , Proliferação de Células
5.
Materials (Basel) ; 15(12)2022 Jun 07.
Artigo em Inglês | MEDLINE | ID: mdl-35744118

RESUMO

This prospective single-arm clinical study aimed to radiographically and histomorphometrically evaluate the efficacy of the lateral approach for sinus floor elevation (LSFE) using biomimetic octacalcium phosphate (OCP) synthetic bone graft (Bontree®). LSFE using Bontree® was performed on 10 patients (15 implant placement sites) willing to undergo implant surgery, followed by implant placements after 6 months of the healing period. The vertical bone height (VBH) and Hounsfield unit (HU) values at each implant placement site were evaluated radiographically using cone-beam computed tomography at baseline immediately after surgery (T1) and 6 months after surgery (T2). A histomorphometric evaluation of the bone core biopsy specimen was also performed. The mean VBH and HU changes at all sites included a decrease by 0.91 mm and a statistically significant increase by 431.86, respectively, from T1 to T2. The mean ratio of the newly formed bone (23.34% ± 10.63%) was greater than that of the residual bone graft (19.09% ± 8.74%), indicating that Bontree® is effective for new bone formation. This pilot study suggests that Bontree® is a promising bone substitute for LSFE.

6.
Materials (Basel) ; 14(18)2021 Sep 14.
Artigo em Inglês | MEDLINE | ID: mdl-34576527

RESUMO

Octacalcium phosphate (OCP) is a precursor of biological apatite crystals that has attracted attention as a possible bone substitute. On the other hand, few studies have examined this material at the experimental level due to the limitations on OCP mass production. Recently, mass production technology of OCP was developed, and the launch of OCP bone substitutes is occurring. In this study, the bone regeneration capacity of OCP products was compared with two of the most clinically used materials: heat-treated bovine bone (BHA) and sintered biphasic calcium phosphate (BCP). Twelve rabbits were used, and defects in each tibia were filled with OCP, BHA, BCP, and left unfilled as control (CON). The tibias were harvested at 4 and 12 weeks, and 15 µm slides were prepared using the diamond grinding method after being embedded in resin. Histological and histomorphometric analyses were performed to evaluate the bone regeneration ability and mechanism. The OCP showed significantly higher resorption and new bone formation in both periods analysed (p < 0.05). Overall, OCP bone substitutes can enhance bone regeneration significantly by activating osteoblasts and a rapid phase transition of OCP crystals to biological apatite crystals (mineralization), as well as providing additional space for new bone formation by rapid resorption.

7.
J Biomater Appl ; 33(5): 662-672, 2018 11.
Artigo em Inglês | MEDLINE | ID: mdl-30396326

RESUMO

BACKGROUND: Recently, some authors introduced a water glass (WG, sodium-silicate glass; Na2O·SiO2·nH2O) coating over tricalcium phosphate (TCP) bioceramic to modulate its resorption rate and enhance the bone cell behaviors. In this study, four different types of granular samples were prepared to evaluate the ability of new bone formation in vivo using micro-computed tomography and histology. METHODS: Four types sample groups: group A (pure HA as a negative resorption control); group B (pure TCP as a positive resorption control); group C (WG-coated TCP as an early resorption model); and group D (same as group C but heat-treated at 500°C as a delayed resorption model). Cylindrical tube-type carriers with holes were fabricated with HA by extrusion and sintering. Each carrier was filled densely with each granular sample. Four types of tubes were implanted into the medial femoral condyle and medial tibial condyle of New Zealand White rabbits. RESULTS: The HA group (A) showed the lowest amount of new bone formation. All the TCP sample groups (B, C, and D) showed more new bone formation. On the other hand, among the TCP groups, group C (early resorption model) showed slightly more bone formation. The amount of residual bioceramics was most abundant in the HA group (A). All the TCP sample groups showed less residual bioceramics than group A. Among the TCP groups, group C showed slightly more residual bioceramics. Group B showed the lowest amount of residual bioceramics. CONCLUSIONS: The WG-coated TCP sample (group C) is the best bone substitute candidate because of its proper biodegradation rate and the Si ions release because the WG-coated layer reduces the material resorption and enhances the new bone formation. That is, the WG-coated TCP is believed to be the best material for the application of an artificial bone substitute material.


Assuntos
Substitutos Ósseos/química , Fosfatos de Cálcio/química , Vidro/química , Osteogênese , Silicatos/química , Água/química , Implantes Absorvíveis , Animais , Regeneração Óssea , Substitutos Ósseos/farmacologia , Fosfatos de Cálcio/farmacologia , Cerâmica/química , Fêmur/fisiologia , Fêmur/cirurgia , Masculino , Osteogênese/efeitos dos fármacos , Coelhos , Silicatos/farmacologia , Tíbia/fisiologia , Tíbia/cirurgia , Água/farmacologia
8.
Adv Mater ; 30(25): e1707224, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-29748976

RESUMO

A novel self-charging platform is proposed using colloidal-quantum-dot (CQD) photovoltaics (PVs) via the near-infrared (NIR) band for low-power electronics. Low-bandgap CQDs can convert invisible NIR light sources to electrical energy more efficiently than wider spectra because of reduced thermalization loss. This energy-conversion strategy via NIR photons ensures an enhanced photostability of the CQD devices. Furthermore, the NIR wireless charging system can be concealed using various colored and NIR-transparent fabric or films, providing aesthetic freedom. Finally, an NIR-driven wireless charging system is demonstrated for a wearable healthcare bracelet by integrating a CQD PVs receiver with a flexible lithium-ion battery and entirely embedding them into a flexible strap, enabling permanent self-charging without detachment.

9.
Korean J Orthod ; 46(1): 13-9, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26877978

RESUMO

OBJECTIVE: The aim of this study was to compare the accuracy of Bolton analysis obtained from digital models scanned with the Ortho Insight three-dimensional (3D) laser scanner system to those obtained from cone-beam computed tomography (CBCT) images and traditional plaster models. METHODS: CBCT scans and plaster models were obtained from 50 patients. Plaster models were scanned using the Ortho Insight 3D laser scanner; Bolton ratios were calculated with its software. CBCT scans were imported and analyzed using AVIZO software. Plaster models were measured with a digital caliper. Data were analyzed with descriptive statistics and the intraclass correlation coefficient (ICC). RESULTS: Anterior and overall Bolton ratios obtained by the three different modalities exhibited excellent agreement (> 0.970). The mean differences between the scanned digital models and physical models and between the CBCT images and scanned digital models for overall Bolton ratios were 0.41 ± 0.305% and 0.45 ± 0.456%, respectively; for anterior Bolton ratios, 0.59 ± 0.520% and 1.01 ± 0.780%, respectively. ICC results showed that intraexaminer error reliability was generally excellent (> 0.858 for all three diagnostic modalities), with < 1.45% discrepancy in the Bolton analysis. CONCLUSIONS: Laser scanned digital models are highly accurate compared to physical models and CBCT scans for assessing the spatial relationships of dental arches for orthodontic diagnosis.

10.
Angew Chem Int Ed Engl ; 54(50): 15094-9, 2015 Dec 07.
Artigo em Inglês | MEDLINE | ID: mdl-26474337

RESUMO

The phase transition of layered manganese oxides to spinel phases is a well-known phenomenon in rechargeable batteries and is the main origin of the capacity fading in these materials. This spontaneous phase transition is associated with the intrinsic properties of manganese, such as its size, preferred crystal positions, and reaction characteristics, and it is therefore very difficult to avoid. The introduction of crystal water by an electrochemical process enables the inverse phase transition from spinel to a layered Birnessite structure. Scanning transmission electron microscopy can be used to directly visualize the rearrangement of lattice atoms, the simultaneous insertion of crystal water, the formation of a transient structure at the phase boundary, and layer-by-layer progression of the phase transition from the edge. This research indicates that crystal water intercalation can reverse phase transformation with thermodynamically favored directionality.

11.
Nano Lett ; 15(6): 4071-9, 2015 Jun 10.
Artigo em Inglês | MEDLINE | ID: mdl-25985060

RESUMO

Rechargeable magnesium batteries have lately received great attention for large-scale energy storage systems due to their high volumetric capacities, low materials cost, and safe characteristic. However, the bivalency of Mg(2+) ions has made it challenging to find cathode materials operating at high voltages with decent (de)intercalation kinetics. In an effort to overcome this challenge, we adopt an unconventional approach of engaging crystal water in the layered structure of Birnessite MnO2 because the crystal water can effectively screen electrostatic interactions between Mg(2+) ions and the host anions. The crucial role of the crystal water was revealed by directly visualizing its presence and dynamic rearrangement using scanning transmission electron microscopy (STEM). Moreover, the importance of lowering desolvation energy penalty at the cathode-electrolyte interface was elucidated by working with water containing nonaqueous electrolytes. In aqueous electrolytes, the decreased interfacial energy penalty by hydration of Mg(2+) allows Birnessite MnO2 to achieve a large reversible capacity (231.1 mAh g(-1)) at high operating voltage (2.8 V vs Mg/Mg(2+)) with excellent cycle life (62.5% retention after 10000 cycles), unveiling the importance of effective charge shielding in the host and facile Mg(2+) ions transfer through the cathode's interface.

12.
Environ Sci Technol ; 49(16): 9415-22, 2015 Aug 18.
Artigo em Inglês | MEDLINE | ID: mdl-25920476

RESUMO

Lithium (Li) is a core element of Li-ion batteries (LIBs). Recent developments in mobile electronics such as smartphones and tablet PCs as well as advent of large-scale LIB applications including electrical vehicles and grid-level energy storage systems have led to an increase in demand for LIBs, giving rise to a concern on the availability and market price of Li resources. However, the current Lime-Soda process that is responsible for greater than 80% of worldwide Li resource supply is applicable only in certain regions on earth where the Li concentrations are sufficiently high (salt lakes or salt pans). Moreover, not only is the process time-consuming (12-18 months), but post-treatments are also required for the purification of Li. Here, we have devised a location-independent electrochemical system for Li capture, which can operate within a short time period (a few hours to days). By engaging olivine LiFePO4 active electrode that improves interfacial properties via polydopamine coating, the electrochemical cell achieves 4330 times amplification in Li/Na ion selectivity (Li/Na molar ratio of initial solution = 0.01 and Li/Na molar ratio of final electrode = 43.3). In addition, the electrochemical system engages an I(-)/I3(-) redox couple in the other electrode for balancing of the redox states on both electrode sides and sustainable operations of the entire cell. Based on the electrochemical results, key material and interfacial properties that affect the selectivity in Li capture are identified.


Assuntos
Eletroquímica/métodos , Lítio/isolamento & purificação , Água do Mar/química , Eletrodos , Eletrólitos/química , Compostos Férricos/química , Indóis/química , Ferro , Fosfatos , Polímeros/química , Espectrofotometria Atômica , Difração de Raios X
13.
Nano Lett ; 15(4): 2350-7, 2015 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-25730382

RESUMO

Most of the existing flexible lithium ion batteries (LIBs) adopt the conventional cofacial cell configuration where anode, separator, and cathode are sequentially stacked and so have difficulty in the integration with emerging thin LIB applications, such as smart cards and medical patches. In order to overcome this shortcoming, herein, we report a coplanar cell structure in which anodes and cathodes are interdigitatedly positioned on the same plane. The coplanar electrode design brings advantages of enhanced bending tolerance and capability of increasing the cell voltage by in series-connection of multiple single-cells in addition to its suitability for the thickness reduction. On the basis of these structural benefits, we develop a coplanar flexible LIB that delivers 7.4 V with an entire cell thickness below 0.5 mm while preserving stable electrochemical performance throughout 5000 (un)bending cycles (bending radius = 5 mm). Also, even the pouch case serves as barriers between anodes and cathodes to prevent Li dendrite growth and short-circuit formation while saving the thickness. Furthermore, for convenient practical use wireless charging via inductive electromagnetic energy transfer and solar cell integration is demonstrated.

14.
Angle Orthod ; 84(3): 443-50, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-23957664

RESUMO

OBJECTIVE: To compare the accuracy of measurements obtained from the three-dimensional (3D) laser scans to those taken from the cone-beam computed tomography (CBCT) scans and those obtained from plaster models. MATERIALS AND METHODS: Eighteen different measurements, encompassing mesiodistal width of teeth and both maxillary and mandibular arch length and width, were selected using various landmarks. CBCT scans and plaster models were prepared from 60 patients. Plaster models were scanned using the Ortho Insight 3D laser scanner, and the selected landmarks were measured using its software. CBCT scans were imported and analyzed using the Avizo software, and the 26 landmarks corresponding to the selected measurements were located and recorded. The plaster models were also measured using a digital caliper. Descriptive statistics and intraclass correlation coefficient (ICC) were used to analyze the data. RESULTS: The ICC result showed that the values obtained by the three different methods were highly correlated in all measurements, all having correlations>0.808. When checking the differences between values and methods, the largest mean difference found was 0.59 mm±0.38 mm. CONCLUSIONS: In conclusion, plaster models, CBCT models, and laser-scanned models are three different diagnostic records, each with its own advantages and disadvantages. The present results showed that the laser-scanned models are highly accurate to plaster models and CBCT scans. This gives general clinicians an alternative to take into consideration the advantages of laser-scanned models over plaster models and CBCT reconstructions.


Assuntos
Tomografia Computadorizada de Feixe Cônico/estatística & dados numéricos , Imageamento Tridimensional/estatística & dados numéricos , Lasers , Modelos Dentários , Pontos de Referência Anatômicos/anatomia & histologia , Dente Pré-Molar/anatomia & histologia , Cefalometria/estatística & dados numéricos , Arco Dental/anatomia & histologia , Humanos , Mandíbula/anatomia & histologia , Maxila/anatomia & histologia , Dente Molar/anatomia & histologia
15.
Nano Lett ; 13(11): 5753-61, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-24164580

RESUMO

Wearable electronics represent a significant paradigm shift in consumer electronics since they eliminate the necessity for separate carriage of devices. In particular, integration of flexible electronic devices with clothes, glasses, watches, and skin will bring new opportunities beyond what can be imagined by current inflexible counterparts. Although considerable progresses have been seen for wearable electronics, lithium rechargeable batteries, the power sources of the devices, do not keep pace with such progresses due to tenuous mechanical stabilities, causing them to remain as the limiting elements in the entire technology. Herein, we revisit the key components of the battery (current collector, binder, and separator) and replace them with the materials that support robust mechanical endurance of the battery. The final full-cells in the forms of clothes and watchstraps exhibited comparable electrochemical performance to those of conventional metal foil-based cells even under severe folding-unfolding motions simulating actual wearing conditions. Furthermore, the wearable textile battery was integrated with flexible and lightweight solar cells on the battery pouch to enable convenient solar-charging capabilities.


Assuntos
Fontes de Energia Elétrica , Energia Solar , Têxteis , Vestuário , Humanos , Nanotecnologia
16.
Nano Lett ; 13(9): 4532-8, 2013 Sep 11.
Artigo em Inglês | MEDLINE | ID: mdl-23981085

RESUMO

Na-S batteries are one type of molten salt battery and have been used to support stationary energy storage systems for several decades. Despite their successful applications based on long cycle lives and low cost of raw materials, Na-S cells require high temperatures above 300 °C for their operations, limiting their propagation into a wide range of applications. Herein, we demonstrate that Na-S cells with solid state active materials can perform well even at room temperature when sulfur-containing carbon composites generated from a simple thermal reaction were used as sulfur positive electrodes. Furthermore, this structure turned out to be robust during repeated (de)sodiation for ~500 cycles and enabled extraordinarily high rate performance when one-dimensional morphology is adopted using scalable electrospinning processes. The current study suggests that solid-state Na-S cells with appropriate atomic configurations of sulfur active materials could cover diverse battery applications where cost of raw materials is critical.

17.
Nano Lett ; 12(12): 6358-65, 2012 Dec 12.
Artigo em Inglês | MEDLINE | ID: mdl-23145851

RESUMO

Spinel-structured lithium manganese oxide (LiMn(2)O(4)) cathodes have been successfully commercialized for various lithium battery applications and are among the strongest candidates for emerging large-scale applications. Despite its various advantages including high power capability, however, LiMn(2)O(4) chronically suffers from limited cycle life, originating from well-known Mn dissolution. An ironical feature with the Mn dissolution is that the surface orientations supporting Li diffusion and thus the power performance are especially vulnerable to the Mn dissolution, making both high power and long lifetime very difficult to achieve simultaneously. In this investigation, we address this contradictory issue of LiMn(2)O(4) by developing a truncated octahedral structure in which most surfaces are aligned to the crystalline orientations with minimal Mn dissolution, while a small portion of the structure is truncated along the orientations to support Li diffusion and thus facilitate high discharge rate capabilities. When compared to control structures with much smaller dimensions, the truncated octahedral structure as large as 500 nm exhibits better performance in both discharge rate performance and cycle life, thus resolving the previously conflicting aspects of LiMn(2)O(4).

18.
Nephrol Dial Transplant ; 20(3): 524-31, 2005 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-15647309

RESUMO

BACKGROUND: Proteinuria is a cardinal feature of glomerular disease, including diabetic nephropathy, and the glomerular filtration barrier acts as a filter, restricting protein excretion in urine. We tested whether the expression of P-cadherin, a molecule known to be located at the slit diaphragm, was altered by diabetes in vivo and by high glucose in vitro. METHODS: In vivo, 24 Sprague-Dawley rats were injected with diluent [control (C), n=8] or streptozotocin intraperitoneally and the latter were left untreated (DM, n=8) or treated with insulin (DM+I, n=8) for 6 weeks. In vitro, immortalized mouse podocytes were cultured in media with 5.6 mM glucose (LG), LG+19.4 mM mannitol (LG+M) or 25 mM glucose (HG) with or without protein kinase C (PKC) inhibitor (10(-7) M calphostin C or 10(-6) M GF 109203X). Reverse transcription-polymerase chain reaction, western blotting for P-cadherin mRNA and protein expression, respectively, were performed with sieved glomeruli and cell lysates, and immunofluorescence staining was undertaken with renal tissue. RESULTS: Twenty-four hour urinary albumin excretion was significantly higher in DM compared with C and DM+I rats (P<0.05). Glomerular P-cadherin mRNA expression was significantly lower in DM (1.36+/-0.20x10(-2) attm/ng RNA) than in C rats (2.61+/-0.33x10(-2) attm/ng RNA) (P<0.05). P-Cadherin protein expression, assessed by western blot and immunofluorescence staining, was also decreased in DM compared with C and DM+I glomeruli. HG significantly reduced P-cadherin mRNA and protein expression in cultured podocytes by 42% and 62%, respectively (P<0.05), and these decrements were ameliorated by PKC inhibitor. CONCLUSIONS: Diabetes in vivo and exposure of podocytes to HG in vitro reduced P-cadherin mRNA and protein expression, and PKC was involved in the regulation of HG-induced down-regulation of P-cadherin. These findings suggest that the decrease in P-cadherin expression is connected with the early changes of diabetic nephropathy and, thus, may contribute to the development of proteinuria.


Assuntos
Caderinas/metabolismo , Diabetes Mellitus Experimental/metabolismo , Células Epiteliais/efeitos dos fármacos , Glucose/administração & dosagem , Glomérulos Renais/metabolismo , Edulcorantes/administração & dosagem , Animais , Caderinas/genética , Técnicas de Cultura de Células , Relação Dose-Resposta a Droga , Células Epiteliais/metabolismo , Glomérulos Renais/citologia , Glomérulos Renais/efeitos dos fármacos , Masculino , Manitol/administração & dosagem , Camundongos , RNA Mensageiro/metabolismo , Ratos , Ratos Sprague-Dawley , Estreptozocina
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA