Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 112
Filtrar
1.
Jpn J Radiol ; 2024 Sep 05.
Artigo em Inglês | MEDLINE | ID: mdl-39235673

RESUMO

PURPOSE: To investigate the diagnostic efficacy of inflator-monitored balloon-occluded retrograde transvenous obliteration (ImBRTO) in detecting balloon rupture and to evaluate the efficacy and safety of the ImBRTO in treating gastric varices. METHODS: Between June 2018 and June 2024, 31 consecutive patients (age: 61.7 ± 12.4 years; male 20, female 11) underwent ImBRTO for gastric varices. An occlusion balloon was inflated with an inflation device to monitor for balloon rupture during sclerosing, maintaining the balloon inflation for at least 3 h. RESULTS: The technical success rate was 100%. The incidence of balloon rupture was 6.5% (2/31), both diagnosed by a pressure drop in the inflation device. In one of the two patients, catheter replacement and an additional injection of a sclerosing agent were required due to early balloon rupture (< 3 h). Clinical success and complete elimination of gastric varices were achieved in all cases. No procedure-related complications were observed. There were no cases of recurrent variceal bleeding at the end of the follow-up (median: 5.2 months). CONCLUSION: ImBRTO proves to be an effective and safe technique for treating gastric varices. The real-time monitoring of balloon integrity allows for timely decisions, resulting in excellent clinical outcomes.

2.
Adv Mater ; 36(40): e2410191, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-39194394

RESUMO

Due to its area and energy efficiency, a memristive crossbar array (CBA) has been extensively studied for various combinatorial optimization applications, from network problems to circuit design. However, conventional approaches include heavily burdening software fine-tuning for the annealing process. Instead, this study introduces the "in-materia annealing" method, where the inter-layer interference of vertically stacked memristive CBA is utilized as an annealing method. When mapping combinatorial optimization problems into the configuration layer of the CBA, exponentially decaying annealing profiles are generated in nearby noise layers. Moreover, in-materia annealing profiles can be controlled by changing compliance current, read voltage, and read pulse width. Therefore, the annealing profiles can be arbitrarily controlled and generated individually for each cell, providing rich noise sources to solve the problem efficiently. Consequently, the experimental and simulation of Max-Cut and weighted Max-Cut problems achieve notable results with the minimum software burden.

3.
Phys Chem Chem Phys ; 26(11): 9021-9036, 2024 Mar 13.
Artigo em Inglês | MEDLINE | ID: mdl-38440829

RESUMO

Interpolation of potential energy surfaces (PESs) can provide a practical route to performing molecular dynamics simulations with a reliability matching a high-level quantum chemical calculation. An obstacle to its widespread use is perhaps the lack of general and optimal interpolation settings that can be applied in a black-box manner for any given molecular system. How to set up the weights for interpolation is one such task, and we still need to diversify the approaches in order to treat various systems. Here, we develop a new interpolation weighting scheme, which allows us to choose the weighting coordinates in a system-specific manner, by amplifying the contribution from specific internal coordinates. The new weighting scheme with an appropriate selection of coordinates is proved to be effective in reducing the interpolation error along the reaction pathway. As a demonstration, we consider the photoactive yellow protein chromophore system, as it constitutes itself as an interesting target that bears long-standing questions related to excited-state dynamics inside protein environments. We build its two-state diabatic interpolated PES with the new weighting scheme. We indeed see the utility of our scheme by conducting nonadiabatic molecular dynamics simulations with the required semi-global PES based on a limited number of data points.

4.
Eur Radiol ; 34(2): 1123-1131, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37597030

RESUMO

OBJECTIVES: This study aimed to compare the analgesic efficacy and safety of the femoral branch block of the genitofemoral nerve (FBB) versus local infiltration anesthesia (LIA) for femoral arterial access gain and closure. METHODS: Eighty-two patients (age, 64.8 ± 10.9 years; female, 30.5%) undergoing endovascular procedures using 5-Fr femoral sheath were assigned to either FBB (n = 41) or LIA (n = 41). In both groups, 2% lidocaine HCL with 1:100,000 epinephrine was used as an anesthetic solution. Pain scores during access gain and closure were evaluated using a visual analog scale (score 0-10), patient satisfaction levels with the quality of anesthesia were scored on a 7-point Likert scale, and adverse events were recorded. RESULTS: The primary endpoint, pain scores during access closure, was significantly lower in the FBB group than in the LIA group (0.1 ± 0.37 vs 1.73 ± 0.92; p < 0.001). The FBB group also had significantly lower pain scores during access gain compared to the LIA group (0.83 ± 0.83 vs 2.78 ± 1.26; p < 0.001). There was an inverse relationship between pain scores and FBB after adjustment for age, gender, and body mass index (p < 0.001). FBB group reported significantly higher satisfaction with anesthesia quality compared to the LIA group (6.49 ± 0.64 vs 4.05 ± 1.05; p < 0.001). No complications were recognized in either group. CONCLUSIONS: Ultrasound-guided genitofemoral nerve blocks offered better acute pain relief and higher patient satisfaction than LIA during femoral arterial access gain and closure. CLINICAL RELEVANCE STATEMENT: In this prospective randomized controlled trial, ultrasound-guided genitofemoral nerve blocks offered better acute pain relief than local infiltration anesthesia, resulting in enhanced patient satisfaction. KEY POINTS: • FBB provided better pain relief during access gain and closure than LIA. • FBB offered higher patient satisfaction with the quality of anesthesia than LIA. • No anesthesia-related or access site complications were recognized in either treatment group.


Assuntos
Dor Aguda , Bloqueio Nervoso , Idoso , Feminino , Humanos , Pessoa de Meia-Idade , Dor Aguda/prevenção & controle , Anestésicos Locais/uso terapêutico , Nervo Femoral , Bloqueio Nervoso/métodos , Estudos Prospectivos , Ultrassonografia de Intervenção , Masculino
5.
Nanoscale Horiz ; 9(3): 427-437, 2024 Feb 26.
Artigo em Inglês | MEDLINE | ID: mdl-38086679

RESUMO

Multiple switching modes in a Ta2O5/HfO2 memristor are studied experimentally and numerically through a reservoir computing (RC) simulation to reveal the importance of nonlinearity and heterogeneity in the RC framework. Unlike most studies, where homogeneous reservoirs are used, heterogeneity is introduced by combining different behaviors of the memristor units. The chosen memristor for the reservoir units is based on a Ta2O5/HfO2 bilayer, in which the conductances of the Ta2O5 and HfO2 layers are controlled by the oxygen vacancies and deep/shallow traps, respectively, providing both volatile and non-volatile resistive switching modes. These several control parameters make the second-order Ta2O5/HfO2 memristor system present different behaviors in agreement with its history-dependent conductance and allow the fine-tuning of the behavior of each reservoir unit. The heterogeneity in the reservoir units improves the pattern recognition performance in the heterogeneous memristor RC system with a similar physical structure.

6.
Neuron ; 111(9): 1423-1439.e4, 2023 05 03.
Artigo em Inglês | MEDLINE | ID: mdl-36863345

RESUMO

Reduced survival motor neuron (SMN) protein triggers the motor neuron disease, spinal muscular atrophy (SMA). Restoring SMN prevents disease, but it is not known how neuromuscular function is preserved. We used model mice to map and identify an Hspa8G470R synaptic chaperone variant, which suppressed SMA. Expression of the variant in the severely affected mutant mice increased lifespan >10-fold, improved motor performance, and mitigated neuromuscular pathology. Mechanistically, Hspa8G470R altered SMN2 splicing and simultaneously stimulated formation of a tripartite chaperone complex, critical for synaptic homeostasis, by augmenting its interaction with other complex members. Concomitantly, synaptic vesicular SNARE complex formation, which relies on chaperone activity for sustained neuromuscular synaptic transmission, was found perturbed in SMA mice and patient-derived motor neurons and was restored in modified mutants. Identification of the Hspa8G470R SMA modifier implicates SMN in SNARE complex assembly and casts new light on how deficiency of the ubiquitous protein causes motor neuron disease.


Assuntos
Atrofia Muscular Espinal , Animais , Camundongos , Modelos Animais de Doenças , Neurônios Motores/metabolismo , Atrofia Muscular Espinal/genética , Atrofia Muscular Espinal/metabolismo , Atrofia Muscular Espinal/patologia , Proteínas SNARE/genética , Proteínas SNARE/metabolismo , Proteína 1 de Sobrevivência do Neurônio Motor/genética , Proteína 1 de Sobrevivência do Neurônio Motor/metabolismo , Sinapses/metabolismo , Transmissão Sináptica , Fatores de Transcrição/metabolismo
7.
Nanoscale ; 15(13): 6387-6395, 2023 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-36919469

RESUMO

The self-rectifying memristor with electronic bipolar resistive switching shows electroforming-free, highly rectifying properties and low operating power. Furthermore, configuring the memristors in a vertical array structure provides a higher memory density than in a planar array structure. These combined advantages can be exploited in in-memory computing, which may provide a new and efficient stateful logic gate with high parallelism compared to the conventional stateful logic gates in the planar array structure. The different switching mechanism compared to the previous logic gates based on filamentary-type switching is explained and exploited to realize the AND and OR Boolean logic gates. Since the AND and OR logic functions are the basic operations of sum-of-product (SoP) and product-of-sum (PoS) expressions, any canonical expression for Boolean logic can be implemented in the vertical crossbar array (CBA). Accordingly, the composite logic gate, such as an exclusive OR operation, is demonstrated. In addition, the implementation of the memristive priority encoder is proposed using parallel logic gates. Although the switching speed should be improved in further work, a higher parallelism with a larger number of layers in the vertical array structure can mitigate the low operation speed issue.

8.
J Clin Med ; 12(4)2023 Feb 10.
Artigo em Inglês | MEDLINE | ID: mdl-36835962

RESUMO

Patients with colorectal cancer (CRC) often fail to complete full-course chemotherapy with a standard dose due to various reasons. This study aimed to determine whether body composition affects chemotherapy adherence in patients with CRC. The medical records of 107 patients with stage III CRC who underwent adjuvant folinic acid, fluorouracil and oxaliplatin (FOLFOX) chemotherapy at a single center between 2014 and 2018 were analyzed retrospectively. Blood test results for selected immunonutritional markers were analyzed and body composition was measured through computed tomography. Univariate and multivariate analyses were performed on low and high relative dose intensity (RDI) groups, based on an RDI of 0.85. In the univariate analysis, a higher skeletal muscle index was correlated with a higher RDI (p = 0.020). Psoas muscle index was also higher in patients with high RDI than in those with low RDI (p = 0.026). Fat indices were independent of RDI. Multivariate analysis was performed for the aforementioned factors and results showed that age (p = 0.028), white blood cell count (p = 0.024), and skeletal muscle index (p = 0.025) affected RDI. In patients with stage III CRC treated with adjuvant FOLFOX chemotherapy, a decrease in RDI was related to age, white blood cell count, and skeletal muscle index. Therefore, if we adjust the drug dosage in consideration of these factors, we can expect an increased treatment efficiency in patients by increasing chemotherapy compliance.

9.
Abdom Radiol (NY) ; 48(4): 1505-1513, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36790453

RESUMO

There are various congenital anomalies and anatomical variations of the spleen (CAAVS). CAAVS are common and are often associated with systemic anomalies. Widespread use of computed tomography and magnetic resonance imaging in a variety of clinical situations has increased the detection of CAAVS. However, CAAVS are frequently overlooked and are occasionally misdiagnosed as pathologic disease entities. This article aimed to review the various manifestations of CAAVS with radiologic findings.


Assuntos
Baço , Tomografia Computadorizada por Raios X , Humanos , Baço/diagnóstico por imagem , Baço/anormalidades , Tomografia Computadorizada por Raios X/métodos , Imageamento por Ressonância Magnética/métodos , Imagem Multimodal
11.
Abdom Radiol (NY) ; 48(2): 621-629, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36494608

RESUMO

PURPOSE: To investigate added value of late portal venous phase (LPVP) for identification of enhancing capsule (EC) on gadoxetate disodium-enhanced MRI (GD-MRI) for diagnosing hepatocellular carcinoma (HCC) in patients with chronic liver disease (CLD). METHODS: This retrospective study comprised 116 high-risk patients with 128 pathologically proven HCCs who underwent GD-MRI including arterial phase, conventional portal venous phase (CPVP, 60 s), LPVP (mean, 104.4 ± 6.7 s; range, 90-119 s), and transitional phase (TP, 3 min). Two independent radiologists assessed the presence of major HCC features, including EC on CPVP and/or TP (CPVP/TP) and EC on LPVP. The frequency of EC was compared on GD-MRI between with and without inclusion of LPVP. The radiologists assigned Liver Imaging Reporting and Data System (LI-RADS) v2018 categories before and after identifying EC on LPVP. RESULTS: Of the total 128 HCCs, 74 and 73 revealed EC on CPVP/TP for reviewer 1 and 2, respectively. After inclusion of LPVP, each reviewer identified seven more EC [Reviewer 1, 57.8% (74/128) vs. 63.3% (81/128); Reviewer 2, 57.0% (73/128) vs. 62.5% (80/128); P = 0.016, respectively]. Sensitivities of LR-5 assignment for diagnosing HCCs were not significantly different in GD-MRI with or without LPVP for EC identification [Reviewer 1, 71.9% (92/128) vs. 72.7% (93/128); Reviewer 2, 75.0% (96/128) vs. 75.8% (97/128); P = 1.000, respectively]. CONCLUSION: Including the LPVP in GD-MRI may improve identification of EC of HCC in patients with CLD. However, LI-RADS v2018 using GD-MRI showed comparable sensitivity for diagnosing HCC regardless of applying LPVP for EC.


Assuntos
Carcinoma Hepatocelular , Neoplasias Hepáticas , Humanos , Carcinoma Hepatocelular/complicações , Carcinoma Hepatocelular/diagnóstico por imagem , Neoplasias Hepáticas/complicações , Neoplasias Hepáticas/diagnóstico por imagem , Estudos Retrospectivos , Meios de Contraste , Gadolínio DTPA , Imageamento por Ressonância Magnética/métodos , Sensibilidade e Especificidade
12.
Adv Mater ; 35(43): e2200659, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35305277

RESUMO

Vertically integrated NAND (V-NAND) flash memory is the main data storage in modern handheld electronic devices, widening its share even in the data centers where installation and operation costs are critical. While the conventional scaling rule has been applied down to the design rule of ≈15 nm (year 2013), the current method of increasing device density is stacking up layers. Currently, 176-layer-stacked V-NAND flash memory is available on the market. Nonetheless, increasing the layers invokes several challenges, such as film stress management and deep contact hole etching. Also, there should be an upper bound for the attainable stacking layers (400-500) due to the total allowable chip thickness, which will be reached within 6-7 years. This review summarizes the current status and critical challenges of charge-trap-based flash memory devices, with a focus on the material (floating-gate vs charge-trap-layer), array-level circuit architecture (NOR vs NAND), physical integration structure (2D vs 3D), and cell-level programming technique (single vs multiple levels). Current efforts to improve fabrication processes and device performances using new materials are also introduced. The review suggests directions for future storage devices based on the ionic mechanism, which may overcome the inherent problems of flash memory devices.

13.
J Vasc Interv Radiol ; 33(11): 1337-1341, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-36511306

RESUMO

This study evaluated the feasibility and safety of imaging-guided deployment of a Mynx Control device (Cordis, Miami Lakes, Florida) at the femoral access. A total of 201 Mynx devices were used under imaging guidance in 137 patients (mean age, 64.18 years ± 13.8; male, 68.6%) between June 2020 and February 2022. A 5-F sheath was used in 176 (87.6%) procedures, a 6-F sheath was used in 17 (8.5%) procedures, and a 7-F sheath was used in 8 (4%) procedures. Indicator errors occurred in 9 (4.5%) procedures. However, technical success was achieved via manipulation under imaging guidance in all procedures. The mean time to hemostasis was 3.3 minutes ± 0.5, and the clinical success rate was 100%. The mean length of hospital stay was 7 days ± 7.5. After 4 (2%) procedures, small hematomas reabsorbed spontaneously. Imaging-guided deployment of a Mynx Control device is a feasible and safe option for access site closure. Even after an indicator error, successful hemostasis was achieved via real-time interaction.


Assuntos
Dispositivos de Oclusão Vascular , Humanos , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento , Hemostasia , Hematoma , Florida , Artéria Femoral , Técnicas Hemostáticas/efeitos adversos
14.
World J Mens Health ; 40(2): 316-329, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35021315

RESUMO

PURPOSE: To build an age prediction model, we measured CD4+ and CD8+ cells, and humoral components in canine peripheral blood. MATERIALS AND METHODS: Large Belgian Malinois (BGM) and German Shepherd Dog (GSD) breeds (n=27), aged from 1 to 12 years, were used for this study. Peripheral bloods were obtained by venepuncture, then plasma and peripheral blood mononuclear cells (PBMCs) were separated immediately. Six myokines, including interleukin (IL)-6, IL-8, IL-15, leukemia inhibitory factor (LIF), growth differentiation factor 8 (GDF8), and GDF11 were measured from plasma and CD4+/CD8+ T-lymphocytes ratio were measured from PBMC. These parameters were then tested with age prediction models to find the best fit model. RESULTS: We found that the T-lymphocyte ratio (CD4+/CD8+) was significantly correlated with age (r=0.46, p=0.016). Among the six myokines, only GDF8 showed a significant correlation with age (r=0.52, p=0.005). Interestingly, these two markers showed better correlations in male dogs than females, and BGM breed than GSD. Using these two age biomarkers, we could obtain the best fit in a quadratic linear mixed model (r=0.77, p=3×10-6). CONCLUSIONS: Age prediction is a challenging task because of complication with biological age. Our quadratic linear mixed model using CD4+/CD8+ ratio and GDF8 level showed a meaningful age prediction.

15.
Waste Manag ; 141: 16-26, 2022 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-35085867

RESUMO

Waste food utilization to produce bio-oil through pyrolysis has received increasing attention. The feedstock can be utilized more efficiently as its properties are upgraded. In this work, the mixed food waste (MFW) was pretreated via torrefaction at moderate temperatures (250-275 °C) under an inert atmosphere before fast pyrolysis. The pyrolysis of torrified MFW (T-MFW) was performed in a bubbling fluidized-bed reactor (FBR) to study the influence of torrefaction on the pyrolysis product distribution and bio-oil compositions. The highest liquid yield of 39.54 wt% was observed at a pyrolysis temperature of 450℃. The torrefaction has a significant effect on the pyrolysis process of MFW. After torrefaction, the higher heating values (HHVs) of the pyrolysis bio-oils (POs) ranged from 31.51 to 34.34 MJ/kg, which were higher than those of bio-oils from raw MFW (27.69-31.58 MJ/kg). The POs mainly contained aliphatic hydrocarbons (alkenes and ketones), phenolic, and N-containing derivatives. The pyrolysis of T-MFW was also carried out under the CO2 atmosphere. The application of CO2 as a carrier gas resulted in a decrease in the liquid yield and an increase in the gas product yield. In addition, the carbon and nitrogen content of POs increased, whereas the oxygen was reduced via the release of moisture and CO. Using CO2 in pyrolysis inhibited the generation of nitriles derivatives in POs, which are harmful to the environment. These results indicated that the application of CO2 to the thermal treatment of T-MFW could be feasible in energy production as well as environmental pollution control.

16.
Medicina (Kaunas) ; 57(12)2021 Dec 16.
Artigo em Inglês | MEDLINE | ID: mdl-34946315

RESUMO

Background and objectives: We conducted this preliminary retrospective study to assess the short-term safety of silicone gel-filled breast implants (SGBIs) that are commercially available in Korean women. Materials and methods :The current retrospective, observational study was conducted in a total of 2612 patients (n = 2612) who underwent augmentation mammaplasty using breast implants at our hospitals between 1 January 2017 and 31 August 2021. Results: Overall, there were a total of 248 cases (9.49%) of postoperative complications; these include 112 cases of early seroma, 52 cases of shape deformation, 32 cases of CC, 12 cases of early hematoma, 12 cases of rupture, 12 cases of infection, 12 cases of stretch deformities with skin excess and 4 cases of rippling. Overall complication-free survival of the breast implant was estimated at 1564.32 ± 75.52 days (95% CI 1416.39-1712.32). Then, the Motiva Ergonomix™ SilkSurface showed the longest survival (1528.00 ± 157.92 days [95% CI 1218.48-1837.56]), followed by the BellaGel® SmoothFine (1458.4 ± 65.76 days [95% CI 1329.56-1587.28]), the Sebbin® Sublimity (1322.00 ± 51.20 days [95% CI 1221.64-1422.32]), the BellaGel® Smooth (1138.72 ± 161.28 days [95% CI 822.6-1454.84), the Mentor® MemoryGel™ Xtra (698.4 ± 52.64 days [95% CI 595.28-801.52]) and the Natrelle® INSPIRA™ (380.00 ± 170.88 days [95% CI 45.04-714.96]) in the decreasing order. On subgroup analysis, both the Motiva ErgonomixTM and Mentor® MemoryGel™ Xtra showed no postoperative complications. However, the BellaGel® SmoothFine, Sebbin® Sublimity and BellaGel® Smooth showed incidences of 8.87%, 4.84% and 1.61%, respectively. A subgroup analysis also showed differences in incidences of postoperative complications between microtextured and smooth breast implants (15.18% vs. 16.67%). Conclusions: In conclusion, our results indicate that diverse types of an SGBI are commercially available and their safety profile varies according to the manufacturer. Plastic surgeons should consider the safety profile of each device in selecting the optimal types of the device for Korean women who are in need of an implant-based augmentation mammaplasty. However, this warrants a single-surgeon, single-center study with long periods of follow-up.


Assuntos
Implante Mamário , Implantes de Mama , Mamoplastia , Implante Mamário/efeitos adversos , Implantes de Mama/efeitos adversos , Feminino , Seguimentos , Humanos , Mamoplastia/efeitos adversos , Complicações Pós-Operatórias/epidemiologia , República da Coreia , Estudos Retrospectivos , Géis de Silicone/efeitos adversos
17.
PLoS One ; 16(9): e0257265, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34529725

RESUMO

Type 1 diabetes (T1D) is an organ-specific autoimmune disease, whereby immune cell-mediated killing leads to loss of the insulin-producing ß cells in the pancreas. Genome-wide association studies (GWAS) have identified over 200 genetic variants associated with risk for T1D. The majority of the GWAS risk variants reside in the non-coding regions of the genome, suggesting that gene regulatory changes substantially contribute to T1D. However, identification of causal regulatory variants associated with T1D risk and their affected genes is challenging due to incomplete knowledge of non-coding regulatory elements and the cellular states and processes in which they function. Here, we performed a comprehensive integrated post-GWAS analysis of T1D to identify functional regulatory variants in enhancers and their cognate target genes. Starting with 1,817 candidate T1D SNPs defined from the GWAS catalog and LDlink databases, we conducted functional annotation analysis using genomic data from various public databases. These include 1) Roadmap Epigenomics, ENCODE, and RegulomeDB for epigenome data; 2) GTEx for tissue-specific gene expression and expression quantitative trait loci data; and 3) lncRNASNP2 for long non-coding RNA data. Our results indicated a prevalent enhancer-based immune dysregulation in T1D pathogenesis. We identified 26 high-probability causal enhancer SNPs associated with T1D, and 64 predicted target genes. The majority of the target genes play major roles in antigen presentation and immune response and are regulated through complex transcriptional regulatory circuits, including those in HLA (6p21) and non-HLA (16p11.2) loci. These candidate causal enhancer SNPs are supported by strong evidence and warrant functional follow-up studies.


Assuntos
Diabetes Mellitus Tipo 1/genética , Diabetes Mellitus Tipo 1/imunologia , Apresentação de Antígeno , Linfócitos T CD4-Positivos/metabolismo , Linfócitos T CD8-Positivos/metabolismo , Análise por Conglomerados , Elementos Facilitadores Genéticos , Epigenoma , Epigenômica , Perfilação da Expressão Gênica , Predisposição Genética para Doença , Variação Genética , Genoma , Estudo de Associação Genômica Ampla , Genômica , Humanos , Sistema Imunitário , Polimorfismo de Nucleotídeo Único , Probabilidade , Locos de Características Quantitativas , RNA Longo não Codificante , Risco
18.
Front Genet ; 12: 680560, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34140970

RESUMO

The rich data from the genome-wide association studies (GWAS) and phenome-wide association studies (PheWAS) offer an unprecedented opportunity to identify the biological underpinnings of age-related disease (ARD) risk and multimorbidity. Surprisingly, however, a comprehensive list of ARDs remains unavailable due to the lack of a clear definition and selection criteria. We developed a method to identify ARDs and to provide a compendium of ARDs for genetic association studies. Querying 1,358 electronic medical record-derived traits, we first defined ARDs and age-related traits (ARTs) based on their prevalence profiles, requiring a unimodal distribution that shows an increasing prevalence after the age of 40 years, and which reaches a maximum peak at 60 years of age or later. As a result, we identified a list of 463 ARDs and ARTs in the GWAS and PheWAS catalogs. We next translated the ARDs and ARTs to their respective 276 Medical Subject Headings diseases and 45 anatomy terms. The most abundant disease categories are neoplasms (48 terms), cardiovascular diseases (44 terms), and nervous system diseases (27 terms). Employing data from a human symptoms-disease network, we found 6 symptom-shared disease groups, representing cancers, heart diseases, brain diseases, joint diseases, eye diseases, and mixed diseases. Lastly, by overlaying our ARD and ART list with genetic correlation data from the UK Biobank, we found 54 phenotypes in 2 clusters with high genetic correlations. Our compendium of ARD and ART is a highly useful resource, with broad applicability for studies of the genetics of aging, ARD, and multimorbidity.

19.
J Vasc Interv Radiol ; 32(6): 802-806, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-34051988

RESUMO

From January 2019 to January 2020, 106 patients (age, 64.8 ± 14.1 years; male, 63.2%) were included to retrospectively investigate the feasibility and safety of ultrasound-guided deployment of ExoSeal after femoral artery access. Baseline characteristics were not different except for age (P = .022), body mass index (P = .009), and diameter (P < .001) between the calcified plaque or stenosis (CS) group (n = 49) and non-CS group (n = 57). The overall technical and clinical success rates were 96.2% and 100%, respectively. The technical (CS group, 48/49; non-CS group, 54/57) and clinical success rates (100%), time to hemostasis (CS group, 3.21 ± 0.54 min; non-CS group, 3.39 ± 0.71 min), and complication rates (CS group, 1/49; non-CS group, 0/57) were not different between the 2 groups. ExoSeal seems to be safe to use under ultrasound guidance in the femoral arteries with CS.


Assuntos
Cateterismo Periférico , Artéria Femoral/diagnóstico por imagem , Técnicas Hemostáticas/instrumentação , Doença Arterial Periférica/terapia , Ultrassonografia de Intervenção , Calcificação Vascular/terapia , Dispositivos de Oclusão Vascular , Idoso , Cateterismo Periférico/efeitos adversos , Constrição Patológica , Desenho de Equipamento , Estudos de Viabilidade , Feminino , Técnicas Hemostáticas/efeitos adversos , Humanos , Masculino , Pessoa de Meia-Idade , Doença Arterial Periférica/diagnóstico por imagem , Punções , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento , Calcificação Vascular/diagnóstico por imagem
20.
Aesthetic Plast Surg ; 45(3): 895-903, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33649929

RESUMO

BACKGROUND: The Motiva Ergonomix™ Round SilkSurface (Establishment Labs Holdings Inc., Alajuela, Costa Rica) is the fifth generation of a silicone gel-filled breast implant that is commercially available in Korea. OBJECTIVES: In this study, we describe 4-year interim results of the safety of augmentation mammaplasty using the Motiva Ergonomix™ Round SilkSurface in Korean women. METHODS: In the current multicenter, retrospective study, we performed a retrospective review of medical records of a total of 1314 patients who received augmentation mammaplasty using the Motiva Ergonomix™ Round SilkSurface at our hospitals between September 1, 2016, and August 31, 2020. For safety assessment, we analyzed incidences of postoperative complications and Kaplan-Meier complication-free survival of the patients. RESULTS: We included a total of 873 patients (1746 breasts, mean age = 32.18 ± 6.88 years) in the current study. There were a total of 111 cases (12.70%) of postoperative complications; these include 24 cases (2.70%) of early seroma, 18 cases (2.10%) of hematoma, 18 cases (2.10%) of capsular contracture, 17 cases (1.95%) of dissatisfaction with shape, 16 cases (1.83%) of dissatisfaction with size, 9 cases (1.03%) of asymmetry, 6 cases (0.70%) of infection and 3 cases (0.34%) of rippling. Moreover, time-to-events were estimated at 918.34 ± 36.22 days (95% CI 845.44-988.52). CONCLUSIONS: Here, we describe 4-year interim results of the safety of augmentation mammaplasty using the Motiva Ergonomix™ Round SilkSurface in Korean women in a non-manufacturer-sponsored study. But further large-scale, prospective, multicenter studies with a long period of follow-up are warranted to establish our results. LEVEL OF EVIDENCE IV: This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to Table of Contents or the online Instructions to Authors www.springer.com/00266 .


Assuntos
Implante Mamário , Implantes de Mama , Mamoplastia , Adulto , Feminino , Seguimentos , Humanos , Mamoplastia/efeitos adversos , Estudos Prospectivos , República da Coreia , Estudos Retrospectivos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA