Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 81
Filtrar
1.
Cardiovasc Res ; 2024 May 14.
Artigo em Inglês | MEDLINE | ID: mdl-38742661

RESUMO

AIMS: Atrial fibrillation (AF), the most common cardiac arrhythmia favoring ischemic stroke and heart failure involves left atrial remodeling, fibrosis and a complex interplay between cardiovascular risk factors. This study examined whether activated factor X (FXa) induces pro-remodeling and pro-fibrotic responses in atrial endothelial cells (AECs) and human atrial tissues and determined the underlying mechanisms. METHODS AND RESULTS: AECs were from porcine hearts and human right atrial appendages (RAA) from patients undergoing heart surgery. Protein expression levels were assessed by Western blot and immunofluorescence staining, mRNA levels by RT-qPCR, formation of reactive oxygen species (ROS) and NO using fluorescent probes, thrombin and angiotensin II generation by specific assays, fibrosis by Sirius red staining and senescence by senescence-associated beta-galactosidase (SA-ß-gal) activity.In AECs, FXa increased ROS formation, senescence (SA-ß-gal activity, p53, p21), angiotensin II generation and the expression of pro-inflammatory (VCAM-1, MCP-1), pro-thrombotic (tissue factor), pro-fibrotic (TGF-ß and collagen-1/3a) and pro-remodeling (MMP-2/9) markers whereas eNOS levels and NO formation were reduced. These effects were prevented by inhibitors of FXa but not thrombin, protease-activated receptors antagonists (PAR-1/2) and inhibitors of NADPH oxidases, ACE, AT1R, SGLT1/SGLT2. FXa also increased expression levels of ACE1, AT1R, SGLT1/2 proteins which was prevented by SGLT1/2 inhibitors. Human RAA showed tissue factor mRNA levels that correlated with markers of endothelial activation, pro-remodeling and pro-fibrotic responses and SGLT1/2 mRNA levels. They also showed protein expression levels of ACE1, AT1R, p22phox, SGLT1/2, and immunofluorescence signals of nitrotyrosine and SGLT1/2 colocalized with those of CD31. FXa increased oxidative stress levels which were prevented by inhibitors of the AT1R/NADPH oxidases/SGLT1/2 pathway. CONCLUSIONS: FXa promotes oxidative stress triggering premature endothelial senescence and dysfunction associated with pro-thrombotic, pro-remodeling and pro-fibrotic responses in AECs and in human RAA involving the AT1R/NADPH oxidases/SGLT1/2 pro-oxidant pathway. Targeting this pathway may be of interest to prevent atrial remodeling and the progression of atrial fibrillation substrate.

2.
ESC Heart Fail ; 2024 Apr 05.
Artigo em Inglês | MEDLINE | ID: mdl-38581135

RESUMO

AIMS: Right ventricular failure after left ventricular assist device (LVAD) implantation is a major concern that remains challenging to predict. We sought to investigate the relationship between preoperative pulmonary artery pulsatility index (PAPi) and mortality after LVAD implantation. METHODS AND RESULTS: A retrospective analysis of the ASSIST-ICD multicentre registry allowed the assessment of PAPi before LVAD according to the formula [(systolic pulmonary artery pressure - diastolic pulmonary artery pressure)/central venous pressure]. The primary endpoint was survival at 3 months, according to the threshold value of PAPi determined by the receiver operating characteristic (ROC) curve. A multivariate analysis including demographic, echographic, haemodynamic, and biological variables was performed to identify predictive factors for 2 year mortality. One hundred seventeen patients were included from 2007 to 2021. The mean age was 58.45 years (±13.16), with 15.4% of women (sex ratio 5.5). A total of 53.4% were implanted as bridge to transplant and 43.1% as destination therapy. Post-operative right ventricular failure was observed in 57 patients (48.7%), with no significant difference between survivors and non-survivors at 1 month (odds ratio 1.59, P = 0.30). The median PAPi for the whole study population was 2.83 [interquartile range 1.63-4.69]. The threshold value of PAPi determined by the ROC curve was 2.84. Patients with PAPi ≥ 2.84 had a higher survival rate at 3 months [PAPi < 2.84: 58.1% [46.3-72.8%] vs. PAPi ≥ 2.84: 89.1% [81.1-97.7%], hazard ratio (HR) 0.08 [0.02-0.28], P < 0.01], with no significant difference after 3 months (HR 0.67 [0.17-2.67], P = 0.57). Other predictors of 2 year mortality were systemic hypertension (HR 4.22 [1.49-11.97], P < 0.01) and diabetes mellitus (HR 4.90 [1.83-13.14], P < 0.01). LVAD implantation as bridge to transplant (HR 0.18 [0.04-0.74], P = 0.02) and heart transplantation (HR 0.02 [0.00-0.18], P < 0.01) were associated with a higher survival rate at 2 years. CONCLUSIONS: Preoperative PAPi < 2.84 was associated with a higher risk of early mortality after LVAD implantation without impacting 2 year outcomes among survivors.

3.
Eur J Cardiothorac Surg ; 65(3)2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38466938

RESUMO

OBJECTIVES: The aim of this study was to assess the safety of early chest tube removal (CTR) protocol on the 1st postoperative day (POD1) of our Enhanced Recovery After Surgery (ERAS) programme by comparing the risk of postoperative pneumothorax, pleural and pericardial effusion requiring intervention and hospital mortality. METHODS: All consecutive patients undergoing elective coronary revascularization and/or valve surgery between 2015 and 2021 were assessed in terms of their perioperative management pathways: conventional standard of care (control group) versus standardized systematic perioperative ERAS programme including an early CTR on POD1 (ERAS group). A propensity score matching was applied. The primary end-point was a composite of postoperative pneumothorax, pleural and pericardial effusion requiring intervention and hospital mortality. RESULTS: A total of 3153 patients were included. Propensity score analysis resulted in 2 groups well-matched pairs of 1026 patients. CTR on POD1 was significantly increased from 29.5% in the control group to 70.3% in the ERAS group (P < 0.001). The incidence of the primary end-point was 6.4% in the control group and 6.9% in the ERAS group (P = 0.658). Patients in the ERAS group, as compared with control group, had significant lower incidence of bronchopneumonia (9.0% vs 13.5%; P = 0.001) and higher incidence of mechanical ventilation ≤6 h (84.6% vs 65.2%; P < 0.001), length of intensive care unit ≤1 day (61.2% vs 50.8%; P < 0.001) and hospital ≤6 days (67.3% vs.43.2%; P < 0.001). CONCLUSIONS: CTR on POD1 protocol can be safely incorporated into a standardized systematic ERAS programme, enabling early mobilization, and contributing to the improvement of postoperative outcomes. CLINICAL TRIAL REGISTRATION NUMBER: Ethics committee of the French Society of Thoracic and Cardio-Vascular Surgery (CERC-SFCTCV-2022-09-13_23140).


Assuntos
Procedimentos Cirúrgicos Cardíacos , Derrame Pericárdico , Pneumotórax , Humanos , Tubos Torácicos , Resultado do Tratamento , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Tempo de Internação , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/prevenção & controle
4.
Int J Mol Sci ; 25(3)2024 Feb 02.
Artigo em Inglês | MEDLINE | ID: mdl-38339113

RESUMO

Delta 9 tetrahydrocannabinol (THC), the main component of cannabis, has adverse effects on the cardiovascular system, but whether concomitant ethanol (EtOH) and aging modulate its toxicity is unknown. We investigated dose responses of THC and its vehicle, EtOH, on mitochondrial respiration and reactive oxygen production in both young and old rat cardiac mitochondria (12 and 90 weeks). THC dose-dependently impaired mitochondrial respiration in both groups, and such impairment was enhanced in aged rats (-97.5 ± 1.4% vs. -75.6 ± 4.0% at 2 × 10-5 M, and IC50: 0.7 ± 0.05 vs. 1.3 ± 0.1 × 10-5 M, p < 0.01, for old and young rats, respectively). The EtOH-induced decrease in mitochondrial respiration was greater in old rats (-50.1 ± 2.4% vs. -19.8 ± 4.4% at 0.9 × 10-5 M, p < 0.0001). Further, mitochondrial hydrogen peroxide (H2O2) production was enhanced in old rats after THC injection (+46.6 ± 5.3 vs. + 17.9 ± 7.8%, p < 0.01, at 2 × 10-5 M). In conclusion, the deleterious cardiac effects of THC were enhanced with concomitant EtOH, particularly in old cardiac mitochondria, showing greater mitochondrial respiration impairment and ROS production. These data improve our knowledge of the mechanisms potentially involved in cannabis toxicity, and likely support additional caution when THC is used by elderly people who consume alcohol.


Assuntos
Etanol , Peróxido de Hidrogênio , Humanos , Ratos , Animais , Idoso , Espécies Reativas de Oxigênio , Etanol/farmacologia , Mitocôndrias Cardíacas , Respiração
5.
Am J Cardiol ; 207: 229-236, 2023 11 15.
Artigo em Inglês | MEDLINE | ID: mdl-37769567

RESUMO

Transcatheter aortic valve replacement (TAVR) becomes the leading therapeutic choice for severe aortic stenosis. There is a growing body of knowledge on long-term survival outcomes, but available data from real-world observational studies are scarce. An observational cohort study was conducted on 705 consecutive patients who underwent TAVR at Strasbourg University Hospital between February 2010 and June 2017. We observed the living status (dead or alive) for each study participants by March 2023. The primary end point was to evaluate the all-cause mortality rate beyond 5 years after TAVR, compare the survival outcomes according to valve type, and identify predictors of mortality. Of the 705 study participants, 91.8% of the TAVR procedures were performed through the common femoral artery and 60.6% were treated with a balloon-expandable valve. Over a mean study period of 5.4 ± 3 years, the all-cause mortality rate was 45.8%. No difference in survival outcomes according to valve type was observed (p = 0.449). All-cause mortality rate was associated with age ≥90 years (hazard ratio [HR] 1.625, 1.109 to 2.380, p = 0.013), female gender (HR 0.228, 0.176 to 0.294, p <0.001), diabetes mellitus (HR 1.356, 1.070 to 1.719, p = 0.012), post-TAVR stroke (HR = 2.867, 1.690 to 4.865, p <0.001), and post-TAVR acute kidney injury (HR 1.977, 1.445 to 2.703, p <0.001). In conclusion, the present real-world large tertiary center experience showed that more than half of patients who underwent TAVR are alive beyond 5 years from procedure's date. All-cause mortality is mainly determined by advanced age and co-morbid conditions, and valve type has no advantage on the survival outcomes.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Idoso de 80 Anos ou mais , Feminino , Humanos , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Fatores de Risco , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/métodos , Resultado do Tratamento , Masculino
6.
Artigo em Inglês | MEDLINE | ID: mdl-37611846

RESUMO

OBJECTIVE: To evaluate the effect of a perioperative systematic standardized enhanced recovery after surgery (ERAS) program for patients undergoing isolated elective coronary artery bypass grafting (CABG) in terms of mortality, hospital morbidities, and length of stay. METHODS: From January 2015 to September 2020, 1101 patients underwent isolated elective CABG. Our standardized systematic ERAS program was implemented in November 2018. Propensity score matching resulted in well-matched pairs of 362 patients receiving standard perioperative care (control group) and 362 patients on the ERAS program (ERAS group). There were no significant intergroup differences in preoperative and operative data except for the normothermia rate, which was significantly greater in the ERAS group (P < .001). The primary outcome was 3-year mortality. The secondary outcomes were hospital morbidities and length of stay. RESULTS: In-hospital and 3-year mortality did not differ between the 2 groups. The ERAS program was associated with a significant relative risk decrease in mechanical ventilation duration (-53.1%, P = .003), length of intensive care unit stay (-28.0%, P = .015), length of hospital stay (-10.5%, P = .046), bronchopneumonia (-51.5%, P < .001), acute respiratory distress syndrome (-50.8%, P = .050), postoperative delirium (-65.4%, P = .011), moderate-to-severe acute kidney injury (-72.0%, P = .009), 24-hour chest tube output (-26.4%, P < .001), and overall red blood cell transfusion rate (-32.4%, P = .005) compared with the control group. CONCLUSIONS: A systematic standardized ERAS program for low-risk patients undergoing isolated elective CABG was associated with a significant improvement in postoperative outcomes, reduction in red blood cell transfusion, shorter lengths of intensive care unit and hospital stays, and comparable long-term mortality.

7.
Eur Heart J Acute Cardiovasc Care ; 12(9): 571-581, 2023 Sep 25.
Artigo em Inglês | MEDLINE | ID: mdl-37319361

RESUMO

AIMS: Heart transplantation (HT) can be proposed as a therapeutic strategy for patients with severe refractory electrical storm (ES). Data in the literature are scarce and based on case reports. We aimed at determining the characteristics and survival of patients transplanted for refractory ES. METHODS AND RESULTS: Patients registered on HT waiting list during the following days after ES and eventually transplanted, from 2010 to 2021, were retrospectively included in 11 French centres. The primary endpoint was in-hospital mortality. Forty-five patients were included [82% men; 55.0 (47.8-59.3) years old; 42.2% and 26.7% non-ischaemic dilated or ischaemic cardiomyopathies, respectively]. Among them, 42 (93.3%) received amiodarone, 29 received (64.4%) beta blockers, 19 (42.2%) required deep sedation, 22 had (48.9%) mechanical circulatory support, and 9 (20.0%) had radiofrequency catheter ablation. Twenty-two patients (62%) were in cardiogenic shock. Inscription on wait list and transplantation occurred 3.0 (1.0-5.0) days and 9.0 (4.0-14.0) days after ES onset, respectively. After transplantation, 20 patients (44.4%) needed immediate haemodynamic support by extracorporeal membrane oxygenation (ECMO). In-hospital mortality rate was 28.9%. Predictors of in-hospital mortality were serum creatinine/urea levels, need for immediate post-operative ECMO support, post-operative complications, and surgical re-interventions. One-year survival was 68.9%. CONCLUSION: Electrical storm is a rare indication of HT but may be lifesaving in those patients presenting intractable arrhythmias despite usual care. Most patients can be safely discharged from hospital, although post-operative mortality remains substantial in this context of emergency transplantation. Larger studies are warranted to precisely determine those patients at higher risk of in-hospital mortality.


Assuntos
Oxigenação por Membrana Extracorpórea , Transplante de Coração , Masculino , Humanos , Pessoa de Meia-Idade , Feminino , Estudos Retrospectivos , Arritmias Cardíacas/etiologia , Choque Cardiogênico/etiologia , Oxigenação por Membrana Extracorpórea/métodos
8.
Eur J Cardiothorac Surg ; 63(5)2023 05 02.
Artigo em Inglês | MEDLINE | ID: mdl-37014362

RESUMO

OBJECTIVES: Evidence regarding the benefits of an enhanced recovery after cardiac surgery (ERACS) programme is lacking. The aim of this study was to analyse the impact of a systematic standardized ERACS programme for patients undergoing isolated elective surgical aortic valve replacement (SAVR) for aortic stenosis in terms of hospital mortality and morbidity, patient blood management and length of stay. METHODS: Patients undergoing isolated elective SAVR for aortic stenosis between 2015 and 2020 were identified from our database (n = 941). The standardized systematic ERACS programme was implemented in November 2018. Propensity score matching indicated that 259 patients would receive standard perioperative care (control group) and 259 patients would receive the ERACS programme (ERACS group). The primary outcome was hospital mortality. The secondary outcomes were hospital morbidity, patient blood management and length of stay. RESULTS: Both groups had similar hospital mortality rates (0.4%). The ERACS group had a significantly lower troponin I peak level (P < 0.001), a larger proportion of improved perioperative left ventricular ejection fractions (P = 0.001), a lower incidence of bronchopneumonia (P = 0.030), a larger proportion of patients with mechanical ventilation <6 h (P < 0.001), a lower incidence of delirium (P = 0.028) and less acute renal failure (P = 0.013). The ERACS group had a significantly lower rate of red blood cell transfusions (P = 0.002). The intensive care unit stay was significantly shorter in the ERACS group than in the control group (P = 0.039). CONCLUSIONS: The standardized systematic ERACS programme significantly improved postoperative outcomes and should become the reference for the perioperative care pathway for patients undergoing SAVR.


Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Humanos , Valva Aórtica/cirurgia , Fatores de Risco , Resultado do Tratamento , Estenose da Valva Aórtica/cirurgia
9.
J Clin Med ; 11(23)2022 Dec 06.
Artigo em Inglês | MEDLINE | ID: mdl-36498821

RESUMO

INTRODUCTION: The mitochondrial function of circulating peripheral blood mononuclear cells (PBMCs) is an interesting new approach to cardiac diseases. Thus, PBMC's mitochondrial respiration decreases in relation to heart failure severity. However, no data are available on heart-transplanted patients (Htx). POPULATION AND METHODS: We determined PBMCs mitochondrial respiration by high-resolution respirometry (Oroboros Instruments) and superoxide anion production using electron paramagnetic resonance (Bruker-Biospin) in 20 healthy subjects and 20 matched Htx and investigated clinical, biological, echocardiographic, coronarography and biopsy characteristics. RESULTS: PBMCs mitochondrial respiratory chain complex II respiration was decreased in Htx (4.69 ± 0.84 vs. 7.69 ± 1.00 pmol/s/million cell in controls and Htx patients, respectively; p = 0.007) and complex IV respiration was increased (24.58 ± 2.57 vs. 15.68 ± 1.67 pmol/s/million cell; p = 0.0035). Superoxide anion production was also increased in Htx (1.47 ± 0.10 vs. 1.15 ± 0.10 µmol/min; p = 0.041). The leucocyte-to-lymphocyte ratio was increased in Htx, whom complex II correlated with leucocyte number (r = 0.51, p = 0.02) and with the left ventricular posterior wall peak early diastolic myocardial velocity (r = -0.62, p = 0.005). Complex IV was increased in the two patients with acute rejection and correlated negatively with Htx's isovolumetric relation time (r = -0.45, p = 0.045). DISCUSSION: Although presenting with normal systolic function, Htx demonstrated abnormal PBMC's mitochondrial respiration. Unlike immunosuppressive therapies, subclinical diastolic dysfunction might be involved in these changes. Additionally, lymphopenia might reduce complex II, and acute rejection enhances complex IV respirations. CONCLUSION: PBMC's mitochondrial respiration appears modified in Htx, potentially linked to cellular shift, mild diastolic dysfunction and/or acute rejection.

10.
Anaesth Crit Care Pain Med ; 41(3): 101059, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35504126

RESUMO

OBJECTIVE: To provide recommendations for enhanced recovery after cardiac surgery (ERACS) based on a multimodal perioperative medicine approach in adult cardiac surgery patients with the aim of improving patient satisfaction, reducing postoperative mortality and morbidity, and reducing the length of hospital stay. DESIGN: A consensus committee of 20 experts from the French Society of Anaesthesia and Intensive Care Medicine (Société française d'anesthésie et de réanimation, SFAR) and the French Society of Thoracic and Cardiovascular Surgery (Société française de chirurgie thoracique et cardio-vasculaire, SFCTCV) was convened. A formal conflict-of-interest policy was developed at the onset of the process and enforced throughout. The entire guideline process was conducted independently of any industry funding. The authors were advised to follow the principles of the Grading of Recommendations Assessment, Development and Evaluation (GRADE) system to guide the assessment of the quality of evidence. METHODS: Six fields were defined: (1) selection of the patient pathway and its information; (2) preoperative management and rehabilitation; (3) anaesthesia and analgesia for cardiac surgery; (4) surgical strategy for cardiac surgery and bypass management; (5) patient blood management; and (6) postoperative enhanced recovery. For each field, the objective of the recommendations was to answer questions formulated according to the PICO model (Population, Intervention, Comparison, Outcome). Based on these questions, an extensive bibliographic search was carried out and analyses were performed using the GRADE approach. The recommendations were formulated according to the GRADE methodology and then voted on by all the experts according to the GRADE grid method. RESULTS: The SFAR/SFCTCV guideline panel provided 33 recommendations on the management of patients undergoing cardiac surgery under cardiopulmonary bypass or off-pump. After three rounds of voting and several amendments, a strong agreement was reached for the 33 recommendations. Of these recommendations, 10 have a high level of evidence (7 GRADE 1+ and 3 GRADE 1-); 19 have a moderate level of evidence (15 GRADE 2+ and 4 GRADE 2-); and 4 are expert opinions. Finally, no recommendations were provided for 3 questions. CONCLUSIONS: Strong agreement existed among the experts to provide recommendations to optimise the complete perioperative management of patients undergoing cardiac surgery.


Assuntos
Anestesia , Anestesiologia , Procedimentos Cirúrgicos Cardíacos , Ponte de Artéria Coronária sem Circulação Extracorpórea , Adulto , Procedimentos Cirúrgicos Cardíacos/reabilitação , Ponte Cardiopulmonar , Ponte de Artéria Coronária sem Circulação Extracorpórea/reabilitação , Cuidados Críticos , Humanos , Tempo de Internação , Satisfação do Paciente
11.
Eur J Cardiothorac Surg ; 62(2)2022 07 11.
Artigo em Inglês | MEDLINE | ID: mdl-35583290

RESUMO

OBJECTIVES: Despite growing evidence that aortic valve repair improves long-term patient outcomes and quality of life, aortic valves are mostly replaced. We evaluate the effect of aortic valve repair versus replacement in patients with dystrophic aortic root aneurysm up to 4 years. METHODS: The multicentric CAVIAAR (Conservation Aortique Valvulaire dans les Insuffisances Aortiques et les Anévrismes de la Racine aortique) prospective cohort study enrolled 261 patients: 130 underwent standardized aortic valve repair (REPAIR) consisting of remodelling root repair with expansible aortic ring annuloplasty, and 131 received mechanical composite valve and graft replacement (REPLACE). Primary outcome was a composite criterion of mortality, reoperation, thromboembolic or major bleeding events, endocarditis or operating site infections, pacemaker implantation and heart failure, analysed with propensity score-weighted Cox model analysis. Secondary outcomes included major adverse valve-related events and components of primary outcome. RESULTS: The mean age was 56.1 years, and valve was bicuspid in 115 patients (44.7%). Up to 4 years, REPAIR did not significantly differ from REPLACE in terms of primary outcome [Hazard Ratio (HR) 0.66 (0.39; 1.12)] but showed significantly less valve-related deaths (HR 0.09 [0.02; 0.34]) and major bleeding events (HR 0.37 [0.16; 0.85]) without an increased risk of valve-related reoperation (HR 2.10 [0.64; 6.96]). When accounting for the occurrence of multiple events in a single patient, the REPAIR group had half the occurrence of major adverse valve-related events (HR 0.51 [0.31; 0.86]). CONCLUSIONS: Although the primary outcome did not significantly differ between the REPAIR and REPLACE groups, the trend is in favour of REPAIR by a significant reduction of valve-related deaths and major bleeding events. Long-term follow-up beyond 4 years is needed to confirm these findings.


Assuntos
Aneurisma Aórtico , Insuficiência da Valva Aórtica , Anuloplastia da Valva Cardíaca , Implante de Prótese de Valva Cardíaca , Humanos , Pessoa de Meia-Idade , Valva Aórtica/cirurgia , Anuloplastia da Valva Cardíaca/efeitos adversos , Aneurisma Aórtico/cirurgia , Estudos Prospectivos , Qualidade de Vida , Resultado do Tratamento , Reoperação/efeitos adversos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Estudos Retrospectivos
12.
Crit Care Med ; 50(5): e426-e433, 2022 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-34974497

RESUMO

OBJECTIVES: Temporary circulatory support (TCS) as a bridge-to-left ventricular assist device (BTL) in cardiogenic shock patients has been increasing, but limited data exists on this BTL strategy. We aimed at analyzing the outcome of BTL patients in a population of cardiogenic shock patients compared with those without TCS at the time of the left ventricular assist device (LVAD) surgery and identify predictors of postoperative mortality in this specific population. DESIGN: A multicenter retrospective observational study conducted in 19 centers from 2006 to 2016. SETTING: Nineteen French centers. PATIENTS: A total of 329 cardiogenic shock patients at the time of LVAD implantation were analyzed. Patients were divided in three groups: those under TCS at the time of LVAD implantation (n = 173), those with TCS removal before LVAD surgery (n = 24), and those who did not undergo a bridging strategy (n = 152). Primary endpoint was 30-day mortality. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: Among the BTL group, 68 (39.3%), 18 (10.4%), and 15 (8.7%) patients were under venoarterial extracorporeal membrane oxygenation, Impella, and IABP support alone, and 72 patients (20.6%) were under multiple TCS support. BTL patients presented similar 30 days survival compared with the TCS removal and non-BTL groups. However, BTL group had a significantly longer ICU duration stay, with two-fold duration of mechanical ventilation time, but the three groups experienced similar postoperative complications. Multivariate analysis identified three independent predictors of mortality in the BTL group: combined surgery with LVAD, body mass index (BMI), and heart failure (HF) duration. BTL strategy was not an independent predictor of mortality in cardiogenic shock patients who underwent LVAD. CONCLUSIONS: BTL strategy is not associated with a lower survival among cardiogenic shock patients with LVAD implantation. Predictors of mortality are combined surgery with LVAD, higher BMI, and HF duration.


Assuntos
Oxigenação por Membrana Extracorpórea , Insuficiência Cardíaca , Coração Auxiliar , Oxigenação por Membrana Extracorpórea/efeitos adversos , Insuficiência Cardíaca/complicações , Insuficiência Cardíaca/cirurgia , Coração Auxiliar/efeitos adversos , Humanos , Estudos Retrospectivos , Choque Cardiogênico/etiologia , Choque Cardiogênico/cirurgia , Resultado do Tratamento
13.
ESC Heart Fail ; 8(6): 5159-5167, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34494391

RESUMO

AIMS: Despite regularly updated guidelines, there is still a delay in referral of advanced heart failure patients to mechanical circulatory support and transplant centres. We aimed to analyse characteristics and outcome of non-inotrope-dependent patients implanted with a left ventricular assist device (LVAD). METHODS AND RESULTS: The ASSIST-ICD registry collected LVAD data in 19 centres in France between February 2006 and December 2016. We used data of patients in Interagency Registry for Mechanically Assisted Circulatory Support Classes 4-7. The primary endpoint was survival analysis. Predictors of mortality were searched with multivariable analyses. A total of 303 patients (mean age 61.0 ± 9.9 years, male sex 86.8%) were included in the present analysis. Ischaemic cardiomyopathy was the leading heart failure aetiology (64%), and bridge to transplantation was the main implantation strategy (56.1%). The overall likelihood of being alive while on LVAD support or having a transplant at 1, 2, 3, and 5 years was 66%, 61.7%, 58.7%, and 55.1%, respectively. Age [hazard ratio (HR) 1.03, 95% confidence interval (CI) 1.00-1.05; P = 0.02], a concomitant procedure (HR 2.32, 95% CI 1.52-3.53; P < 0.0001), and temporary mechanical right ventricular support during LVAD implantation (HR 2.94, 95% CI 1.49-5.77; P = 0.002) were the only independent variables associated with mortality. Heart failure medications before or after LVAD implantation were not associated with survival. CONCLUSION: Ambulatory heart failure patients displayed unsatisfactory survival rates after LVAD implantation. A better selection of patients who can benefit from LVAD may help improving outcomes.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Idoso , Insuficiência Cardíaca/complicações , Insuficiência Cardíaca/terapia , Humanos , Masculino , Pessoa de Meia-Idade , Sistema de Registros , Taxa de Sobrevida , Resultado do Tratamento
14.
Am J Cardiol ; 146: 82-88, 2021 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-33549526

RESUMO

LVAD implantation in patients with a recently diagnosed cardiomyopathy has been poorly investigated. This work aims at describing the characteristics and outcomes of patients receiving a LVAD within 30 days following the diagnosis of cardiomyopathy. Patients from the ASSIST-ICD study was divided into recently and remotely diagnosed cardiomyopathy based on the time from initial diagnosis of cardiomyopathy to LVAD implantation using the cut point of 30 days. The primary end point of the study was all-cause mortality at 30-day and during follow-up. A total of 652 patients were included and followed during a median time of 9.1 (2.5 to 22.1) months. In this population, 117 (17.9%) had a recently diagnosed cardiomyopathy and had LVAD implantation after a median time of 15.0 (9.0 to 24.0) days following the diagnosis. This group of patients was significantly younger, with more ischemic cardiomyopathy, more sudden cardiac arrest (SCA) events at the time of the diagnosis and were more likely to receive temporary mechanical support before LVAD compared with the remotely diagnosed group. Postoperative in-hospital survival was similar in groups, but recently diagnosed patients had a better long-term survival after hospital discharge. SCA before LVAD and any cardiac surgery combined with LVAD implantation were identified as 2 independent predictors of postoperative mortality in recently diagnosed patients. In conclusion, rescue LVAD implantation for recently diagnosed severe cardiomyopathy is common in clinical practice. Such patients experience a relatively low postoperative mortality and have a better long-term survival compared with remotely diagnosed patients.


Assuntos
Cardiomiopatias/terapia , Coração Auxiliar , Idoso , Cardiomiopatias/diagnóstico , Cardiomiopatias/mortalidade , Feminino , França/epidemiologia , Humanos , Masculino , Pessoa de Meia-Idade , Prognóstico , Desenho de Prótese , Estudos Retrospectivos , Taxa de Sobrevida/tendências
15.
J Clin Med ; 10(2)2021 Jan 07.
Artigo em Inglês | MEDLINE | ID: mdl-33430206

RESUMO

Published data on the size-specific effective orifice area (EOA) of transcatheter heart valves (THVs) remain scarce. Here, we sought to investigate the intra-individual changes in EOA and mean transvalvular aortic gradient (MG) of the Sapien 3 (S3), CoreValve (CV), and Evolut R (EVR) prostheses both at short-term and at 1-year follow-up. The study sample consisted of 260 consecutive patients with severe aortic stenosis who underwent transcatheter aortic valve implantation (TAVI). EOAs and MGs were measured with Doppler echocardiography for the following prostheses: S3 23 mm (n = 74; 28.5%), S3 26 mm (n = 67; 25.8%), S3 29 mm (n = 20; 7.7%), CV 23 mm (n = 2; 0.8%), CV 26 mm (n = 15; 5.8%), CV 29 mm (n = 24; 9.2%), CV 31 mm (n = 9; 3.5%), EVR 26 mm (n = 22; 8.5%), and EVR 29 mm (n = 27; 10.4%). Values were obtained at discharge, 1 month, 6 months, and 1 year from implantation. At discharge, EOAs were larger and MGs lower for larger-size prostheses, regardless of being balloon-expandable or self-expandable. In patients with small aortic annulus size, the hemodynamic performances of CV and EVR prostheses were superior to those of S3. However, we did not observe significant differences in terms of all-cause mortality according to THV type or size. Both balloon-expandable and self-expandable new-generation THVs show excellent hemodynamic performances without evidence of very early valve degeneration.

16.
Arch Cardiovasc Dis ; 113(11): 701-709, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-32952086

RESUMO

BACKGROUND: Left ventricular assist device (LVAD) implantation may be an attractive alternative therapeutic option for elderly patients with heart failure who are ineligible for heart transplantation. AIM: We aimed to describe the characteristics and outcomes of elderly patients (i.e. aged≥70 years) receiving an LVAD. METHODS: This observational study was conducted in 19 centres between 2006 and 2016. Patients were divided into two groups-younger (aged<70 years) and elderly (aged≥70 years), based on age at time of LVAD implantation. RESULTS: A total of 652 patients were included in the final analysis, and 74 patients (11.3%) were aged≥70 years at the time of LVAD implantation (maximal age 77.6 years). The proportion of elderly patients receiving an LVAD each year was constant, with a median of 10.6% (interquartile range 8.0-15.4%) per year, and all were implanted as destination therapy. Elderly and younger patients had similar durations of hospitalization in intensive care units and total lengths of hospital stays. Both age groups experienced similar rates of LVAD-related complications (i.e. stroke, bleeding, driveline infection and LVAD exchange), and the occurrence of LVAD complications did not impact survival in the elderly group compared with the younger group. Lastly, when compared with younger patients implanted as destination therapy, the elderly group also exhibited similar mid-term survival. CONCLUSION: This work strongly suggests that selected elderly adults can be scheduled for LVAD implantation.


Assuntos
Insuficiência Cardíaca/terapia , Implantação de Prótese/instrumentação , Função Ventricular Esquerda , Fatores Etários , Idoso , Feminino , França , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/fisiopatologia , Coração Auxiliar , Humanos , Masculino , Pessoa de Meia-Idade , Implantação de Prótese/efeitos adversos , Implantação de Prótese/mortalidade , Recuperação de Função Fisiológica , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
17.
Am J Cardiol ; 133: 81-88, 2020 10 15.
Artigo em Inglês | MEDLINE | ID: mdl-32861423

RESUMO

We aimed at characterizing the impact of low and high body mass index (BMI) on outcomes after left-ventricular assist device (LVAD) surgery and define the predictors of mortality in patients with abnormal BMI (low/high). This study was conducted in 19 centers from 2006 to 2016. Patients were divided based on their baseline BMI into 3 groups of BMI: low (BMI ≤18.5 kg/m²); normal (BMI = 18.5 to 24.99 kg/m²) and high (BMI ≥25 kg/m²) (including overweight (BMI = 25 to 29.99 kg/m²), and obesity (BMI ≥30 Kg/m²)). Among 652 patients, 29 (4.4%), 279 (42.8%) and 344 (52.8%) had a low-, normal-, and high BMI, respectively. Patients with high BMI were significantly more likely men, with more co-morbidities and more history of ventricular/supra-ventricular arrhythmias before LVAD implantation. Patients with abnormal BMI had significantly lower survival than those with normal BMI. Notably, those with low BMI experienced the worst survival whereas overweight or obese patients had similar survival. Four predictors of mortality for LVAD candidates with abnormal BMI were defined: total bilirubin ≥16 µmol/L before LVAD, hypertension, destination therapy, and cardiac surgery with LVAD. Depending on the number of predictor per patients, those with abnormal BMI may be divided in 3 groups of 1-year mortality risk, i.e., low (0 to 1 predictor: 29% and 31%), intermediate (2 to 3 predictors, 51% and 52%, respectively), and high (4 predictors: 83%). In conclusion, LVAD recipients with abnormal BMI experience lower survival, especially underweight patients. Four predictors of mortality have been identified for LVAD population with abnormal BMI, differentiating those a low-, intermediate-, and high risks of death.


Assuntos
Índice de Massa Corporal , Insuficiência Cardíaca/terapia , Coração Auxiliar , Obesidade/complicações , Magreza/complicações , Idoso , Feminino , Seguimentos , Insuficiência Cardíaca/complicações , Insuficiência Cardíaca/mortalidade , Humanos , Masculino , Pessoa de Meia-Idade , Obesidade/mortalidade , Estudos Retrospectivos , Fatores de Risco , Taxa de Sobrevida , Magreza/mortalidade , Resultado do Tratamento
18.
J Thorac Dis ; 12(5): 2654-2662, 2020 May.
Artigo em Inglês | MEDLINE | ID: mdl-32642173

RESUMO

BACKGROUND: Left ventricular assist device (LVAD)-associated infections are major complications that can lead to critical outcomes. The aims of this study were to assess the incidence of and to determine the risk factors for LVAD-associated infections. METHODS: We included all consecutive patients undergoing LVAD implantation between January 1, 2010, and January 1, 2019, in a single institution. Infection-related data were retrospectively collected by review of patient's medical files. LVAD-associated infections were classified into three categories: percutaneous driveline infections, pocket infections and pump and/or cannula infections. RESULTS: We enrolled 72 patients. Twenty-one (29.2%) patients presented a total of 32 LVAD-associated infections. Eight (38.1%) patients had more than one infection. Five (62.5%) pocket infections and one (50.0%) pump and/or cannula infection were preceded by a driveline infection. The median delay between the operation and LVAD-associated infection was 6.5 (1.4-12.4) months. The probability of having a LVAD-associated infection at one year after receiving an implant was 26.6% (95% CI: 17.5-40.5%). Percutaneous driveline infections represented 68.7% of all LVAD-associated infections. Staphylococcus aureus and coagulase-negative staphylococci were the predominant bacteria in LVAD-associated infections (53.1% and 15.6%, respectively). Hospital length of stay (sdHR =1.22 per 10 days; P=0.001) and postoperative hemodialysis (sdHR =0.17; P=0.004) were statistically associated with infection. Colonization with multidrug-resistant bacteria was more frequent in patients with LVAD-associated infections than in others patients (42.9% vs. 15.7%; P=0.013). CONCLUSIONS: LVAD-associated infections remain an important complication and are mostly represented by percutaneous driveline infections. Gram-positive cocci are the main pathogens isolated in microbiological samples. Patients with LVAD-associated infections are more frequently colonized with multidrug-resistant bacteria.

19.
Thromb Haemost ; 120(9): 1330-1338, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32726854

RESUMO

BACKGROUND: Stroke is a major cause of disability after transcatheter aortic valve replacement (TAVR) and stroke prediction models and data are crucially needed. Following TAVR, high molecular weight (HMW) multimers defect of von Willebrand factor (VWF) as assessed by closure time of adenosine diphosphate (CT-ADP) value > 180 seconds is an independent predictor of bleeding events. This study sought to identify predictors of ischemic neurological events in patients who underwent TAVR and the specific impact of HMW multimers defect of VWF. METHODS: Patients were prospectively enrolled between November 2012 and May 2018 at our institution. The CT-ADP, a point-of-care measure of hemostasis, was assessed the day before and 24 hours after the procedures. The rate of ischemic stroke and transient ischemic attack (TIA) was recorded up to 30 days after the procedures. RESULTS: Of 565 TAVR patients, ischemic stroke/TIA was observed in 21 (3.7%) patients within 30 days. Ischemic stroke/TIA was associated with major/life-threatening bleeding complications (MLBCs) (9 [43%] vs. 88 [16%], p = 0.002) and postprocedure CT-ADP > 180 seconds (10 [48%] vs. 116 [21%], p = 0.01). By multivariate analysis, MLBCs (odds ratio [OR]: 3.58; 95% confidence interval [CI]: 1.45-8.84; p = 0.006) and postprocedure CT-ADP > 180 seconds (OR: 3.38; 95% CI: 1.38-8.25; p = 0.008) were evidenced as independent predictors of ischemic stroke/TIA. CONCLUSION: MLBCs and CT-ADP > 180 seconds were identified as predictors for ischemic stroke or TIA. The present study suggests that the defects of HMW multimers of the VWFs may contribute not only to bleeding events but also to thrombotic events.


Assuntos
Acidente Vascular Cerebral/etiologia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Fator de von Willebrand/metabolismo , Idoso , Idoso de 80 Anos ou mais , Feminino , Hemorragia/etiologia , Hemorragia/metabolismo , Humanos , Incidência , Masculino , Estudos Prospectivos , Multimerização Proteica , Acidente Vascular Cerebral/metabolismo , Trombose/etiologia , Trombose/metabolismo , Fator de von Willebrand/análise
20.
Pacing Clin Electrophysiol ; 43(11): 1309-1317, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-32627211

RESUMO

BACKGROUND: Implantable cardioverter-defibrillator (ICD) lead dysfunction has been reported after left ventricular assist device (LVAD) implantation in limited single-center studies. We aimed at describing and characterizing the incidence of ICD lead parameters dysfunction after LVAD implantation. METHODS: Among the 652 patients enrolled in the ASSIST-ICD study, only patients with an ICD prior to LVAD were included (n = 401). ICD lead parameters dysfunction following LVAD implantation is defined as follows: (a) >50% decrease in sensing threshold, (b) pacing lead impedance increase/decrease by >100Ω, and (c) >50% increase in pacing threshold. RESULTS: One hundred twenty-two patients with an ICD prior to LVAD had available ICD interrogation reports prior and after LVAD. A total of 67 (55%) patients exhibited at least one significant lead dysfunction: 17 (15%) exhibited >50% decrease in right ventricular (RV) sensing, 51 (42%) had >100 Ω increase/decrease in RV pacing impedance, and 24 (20%) experienced >50% increase in RV pacing threshold. A total of 52 patients experienced ventricular arrhythmia during follow-up and all were successfully detected and treated by the device. All lead dysfunction could be managed conservatively. CONCLUSION: More than 50% of LVAD-recipients may experience >1 significant change in lead parameters but none had severe clinical consequences.


Assuntos
Desfibriladores Implantáveis/efeitos adversos , Eletrodos Implantados/efeitos adversos , Coração Auxiliar , Idoso , França , Humanos , Masculino , Pessoa de Meia-Idade , Falha de Prótese
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA