Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 191
Filtrar
1.
Cureus ; 16(8): e66400, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-39246974

RESUMO

Background A disposable i-view® video laryngoscope (Intersurgical Limited, Berkshire, United Kingdom) is yet to be used to educate medical and dental students, who must learn endotracheal intubation skills. Additionally, the advantage of the i-view® use for the purpose, compared with the Macintosh laryngoscope, is unknown. We aimed to first determine whether the i-view® video laryngoscope enhances endotracheal intubation skills among dental students compared with the Macintosh laryngoscope. Methodology A prospective, observational, simulation study was conducted among 67 dental students in their sixth clinical year of education. Intubation skills were evaluated on a computer-assisted simulator with a standardized manikin. Each student was asked to intubate using the conventional Macintosh laryngoscope and the i-view® video laryngoscope in the trachea of the simulator's manikin. We collected objective data, including the retroflection angle of the manikin, the maxillary incisor contact pressure, time from picking up the laryngoscope to ventilation, intubation success, and intubation delay. Each student was further asked to grade their subjective evaluation concerning the visual field, Cormack and Lehane classification, operability, stability, needed force for intubation, and easiness during intubation. Results Enrolled dental students quoted that the i-view® video laryngoscope demonstrated better visual field, Cormack and Lehane classification, operability, and stability than the Macintosh laryngoscope. However, they felt intubation easiness could have been better using Macintosh than i-view®. Intubation time, failure rate, and delay rate did not differ between the two laryngoscopes. Nevertheless, the maxillary incisor contact pressure (median interquartile range (IQR)) during the intubation increased in the i-view® intubation compared with Macintosh (32 (24 to 41) vs. 25 (18 to 35) N, p = 0.010). Conclusions We first demonstrated that the i-view® video laryngoscope compared with the Macintosh laryngoscope does not enhance the endotracheal intubation skills of dental students. However, the possible repeated use as an educational simulator training tool may add some advantages to the experience of video laryngoscope in both medical and dental students.

2.
Appl Environ Microbiol ; 90(9): e0100724, 2024 Sep 18.
Artigo em Inglês | MEDLINE | ID: mdl-39177327

RESUMO

Akahoya is a volcanic soil rich in alumina, primarily deposited in Kyushu, Japan. We have found that Akahoya adsorbs bacteria in the water surrounding cattle grazing areas, suggesting a potential for environmental purification. This study investigated the spectrum of microorganisms adsorbed by Akahoya using a column filled with Akahoya through which a suspension of microorganisms was passed. Shirasu soil, another volcanic soil with a different chemical composition, was used as a control. Akahoya effectively adsorbed a diverse range of microorganisms including Escherichia coli, Campylobacter jejuni, Vibrio parahaemolyticus, Salmonella Enteritidis, Staphylococcus aureus, Clostridium perfringens, spores of Bacillus subtilis and Bacillus anthracis, severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), murine norovirus, and avian influenza virus (H3N2), whereas Shirasu soil did not adsorb any of the organisms examined. Moreover, bacteria naturally present in river water, such as aerobic bacteria, total coliforms, and Enterobacteriaceae as indicators of river contamination, as well as E. coli added artificially to sterilized river water, were reduced to below the detection limit (<1 CFU/mL) after being passed through Akahoya. Additionally, the number of viable E. coli continued to decrease after contact with Akahoya for 1 month, suggesting bactericidal effects. Notably, the adsorption of E. coli to Akahoya was influenced by the concentration of phosphate and the pH of the suspension due to the interaction between the surface phosphorylation of organisms and Al2O3, the major chemical component of Akahoya. The present results demonstrate the remarkable ability of Akahoya to remove phosphate and microbes, suggesting that Akahoya could be used for water purification processes.IMPORTANCEAlthough a safe and sufficient water supply is essential for the maintenance of hygienic conditions, a major challenge is to develop a comprehensive effective, sustainable, and cost-effective technological approach for the treatment and purification of contaminated water. In this study, we demonstrated that a novel volcanic soil, Akahoya, which has unlimited availability, is a highly effective adsorbent for a wide range of bacterial and viral pathogens, suggesting its potential as a sustainable resource for this purpose. It was suggested that the adsorption of microorganisms on Akahoya was mediated by phosphate groups present on the surface structures of microorganisms, which bind to the alumina component of Akahoya according to the phosphate concentration and pH of the liquid phase. The present findings highlight the exceptional ability of Akahoya to eliminate or reduce phosphate and microorganisms effectively in water purification processes, thus contributing to the development of efficient and sustainable solutions for addressing water pollution challenges.


Assuntos
Bactérias , Bactérias/genética , Bactérias/isolamento & purificação , Bactérias/metabolismo , Adsorção , Vírus/genética , Vírus/isolamento & purificação , Microbiologia do Solo , Solo/química , Animais , Japão , Purificação da Água/métodos , Microbiologia da Água , Rios/microbiologia , Rios/virologia , Óxido de Alumínio/química
3.
J Anesth ; 38(5): 721-722, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-38822139
8.
Cureus ; 15(9): e44670, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37799239

RESUMO

Background Mechanistic insight into the high failure rate of TOF-Cuff® (RGB Medical Devices, Madrid, Spain) measurements on the lower leg is unclear. Aims We aimed to determine whether materials applied to pseudo-skin can reduce the impedance between a model arm and TOF-Cuff® electrodes and whether a material between TOF-Cuff® electrodes and the patient's skin surface decreases the skin-TOF-Cuff® electrode impedance within the appropriate range. Methods This was a combination of an in vitro study using non-living materials and a prospective observational clinical study. Eight patients aged > 70 years who had undergone elective surgery were eligible. One of the primary outcomes was whether water, electrocardiogram (ECG) cream, or ECG gel applied on the pseudo-skin could reduce the impedance between the model arm and the TOF-Cuff® electrodes in the in vitro study. Another was whether a material between the TOF-Cuff® electrodes and the patient's skin surface decreased the skin-TOF-Cuff® electrode impedance to an appropriate level of less than 5,000 Ω in the clinical study. Results The application of water, ECG cream, and ECG gel similarly reduced the impedance values within the electrical circuit in the in vitro study. ECG cream application between the patient's skin surface and the TOF-Cuff® electrodes decreased the skin-TOF-Cuff® electrode impedance (median (interquartile range (IQR)) Ω) from 8,600 (6,450 to 9,775) to 2,000 (1,600 to 2,600) (P = 0.012) in surgical patients. Conclusion ECG cream application between the patient's skin surface and the TOF-Cuff® electrodes decreased the skin-TOF-Cuff® electrode impedance appropriately, and thus, the application can facilitate precise TOF-Cuff® measurements in patients.

9.
Braz. J. Anesth. (Impr.) ; 73(2): 227-229, March-Apr. 2023. graf
Artigo em Inglês | LILACS | ID: biblio-1439582

RESUMO

Abstract A male patient was scheduled for urgent amputation of his right forearm. His right forearm was stuck inside the insertion slot of a meat grinder, resulting in severe pain to his injured arm. His upper body could not move to sit in a semi-upright position. An endotracheal tube was successfully placed after rapid sequence intubation using a video laryngoscope from behind the patient on the first attempt. This case report is the first documentation of successful anesthetic induction with subsequent endotracheal intubation using a video laryngoscope from behind an injured patient whose upper body was upright with limited positioning.


Assuntos
Humanos , Masculino , Laringoscópios , Anestésicos , Antebraço/cirurgia , Postura Sentada , Intubação Intratraqueal/métodos , Laringoscopia/métodos
10.
J Hypertens ; 41(5): 811-818, 2023 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-36883464

RESUMO

OBJECTIVE: Automated cuff blood pressure (BP) devices are widely used for ambulatory, home, and office BP measurement. However, an automated device, which is accurate in the general adult population may be inaccurate in some special populations. A 2018 Collaborative Statement by the US Association for the Advancement of Medical Instrumentation, the European Society of Hypertension, and the International Organization for Standardization (ISO) considered three special populations requiring separate validation (age <3 years, pregnancy, and atrial fibrillation). An ISO Task Group was appointed to identify evidence for additional special populations. METHOD: Evidence on potential special populations was identified from the STRIDE BP database, which performs systematic PubMed searches for published validation studies of automated cuff BP monitors. Devices that passed in a general population, but failed in potential special populations were identified. RESULTS: Of 338 publications (549 validations, 348 devices) in the STRIDE BP database, 29 publications (38 validations, 25 devices) involved 4 potential special populations: (i) age 12-18 years: 3 of 7 devices failed but passed in a general population; (ii) age more than 65 years: 1 of 11 devices failed but passed in a general population; (iii) diabetes type-2: 4 devices (all passed); (iv) chronic kidney disease: 2 of 7 devices failed but passed in a general population. CONCLUSION: Some evidence suggest that the automated cuff BP devices may have different accuracy in adolescents and in patients with chronic kidney disease than in the general population. More research is needed to confirm these findings and investigate other potential special populations.


Assuntos
Hipertensão , Insuficiência Renal Crônica , Adulto , Feminino , Gravidez , Humanos , Adolescente , Pré-Escolar , Criança , Idoso , Monitores de Pressão Arterial , Determinação da Pressão Arterial , Hipertensão/diagnóstico , Padrões de Referência , Pressão Sanguínea
11.
Nanomaterials (Basel) ; 13(3)2023 Jan 30.
Artigo em Inglês | MEDLINE | ID: mdl-36770529

RESUMO

"Akahoya" is a volcanic soil classified as a special soil deposited in Kyushu, Japan. Many of its properties are not yet clearly understood. We found that Akahoya had the potential to adsorb bacteria in cattle feces, which prompted us to investigate its material properties and perform experiments to comprehensively evaluate its adsorption performance for various fine particles such as acidic and basic dyes, NOx/SOx gas, and phosphoric acid ions, in addition to bacteria. Akahoya had a very high specific surface area owing to the large number of nanometer-sized pores in its structure; it exhibited a high adsorption capacity for both NO2 and SO2. Regarding the zeta potential of Akahoya, the point of zero charge was approximately pH 7.0. The surface potential had a significant effect on the adsorption of acidic and basic dyes. Akahoya had a very high cation exchange capacity when the sample surface was negatively charged and a high anion exchange capacity when the sample surface was positively charged. Akahoya also exhibited a relatively high adsorption capacity for phosphoric acid because of its high level of Al2O3, and the immersion liquid had a very high Al ion concentration. Finally, filtration tests were performed on Escherichia coli suspension using a column filled with Akahoya or another volcanic soil sample. The results confirmed that the Escherichia coli adhered on the Akahoya sample. The results of the Escherichia coli release test, after the filtration test, suggested that this adhesion to Akahoya could be phosphorus-mediated.

12.
Braz J Anesthesiol ; 73(2): 227-229, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-34411634

RESUMO

A male patient was scheduled for urgent amputation of his right forearm. His right forearm was stuck inside the insertion slot of a meat grinder, resulting in severe pain to his injured arm. His upper body could not move to sit in a semi-upright position. An endotracheal tube was successfully placed after rapid sequence intubation using a video laryngoscope from behind the patient on the first attempt. This case report is the first documentation of successful anesthetic induction with subsequent endotracheal intubation using a video laryngoscope from behind an injured patient whose upper body was upright with limited positioning.


Assuntos
Anestésicos , Laringoscópios , Humanos , Masculino , Antebraço/cirurgia , Postura Sentada , Intubação Intratraqueal/métodos , Laringoscopia/métodos
14.
J Anesth ; 37(1): 13-22, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36220948

RESUMO

PURPOSE: Postoperative delirium is one of the most common complications after cardiovascular surgery in older adults. Benzodiazepines are a reported risk factor for delirium; however, there are no studies investigating remimazolam, a novel anesthetic agent. Therefore, we prospectively investigated the effect of remimazolam on postoperative delirium. METHODS: We included elective cardiovascular surgery patients aged ≥ 65 years at Hamamatsu University Hospital between August 2020 and February 2022. Patients who received general anesthesia with remimazolam were compared with those who received other anesthetics (control group). The primary outcome was delirium within 5 days after surgery. Secondary outcomes were delirium during intensive care unit stay and hospitalization, total duration of delirium, subsyndromal delirium, and differences in the Mini-Mental State Examination scores from preoperative to postoperative days 2 and 5. To adjust for differences in the groups' baseline covariates, we used stabilized inverse probability weighting as the primary analysis and propensity score matching as the sensitivity analysis. RESULTS: We enrolled 200 patients; 78 in the remimazolam group and 122 in the control group. After stabilized inverse probability weighting, 30.3% of the remimazolam group patients and 26.6% of the control group patients developed delirium within 5 days (risk difference, 3.8%; 95% confidence interval -11.5% to 19.1%; p = 0.63). The secondary outcomes did not differ significantly between the groups, and the sensitivity analysis results were similar to those for the primary analysis. CONCLUSION: Remimazolam was not significantly associated with postoperative delirium when compared with other anesthetic agents.


Assuntos
Anestésicos , Delírio , Delírio do Despertar , Humanos , Idoso , Delírio do Despertar/complicações , Complicações Pós-Operatórias , Estudos Prospectivos , Delírio/etiologia , Benzodiazepinas
16.
Circ J ; 2022 Nov 18.
Artigo em Inglês | MEDLINE | ID: mdl-36403975

RESUMO

BACKGROUND: Whether nerve block improves the quality of conscious sedation (CS) in patients undergoing transcatheter aortic valve implantation (TAVI) is unclear. This study investigated whether fascia iliaca block (FIB) reduced the remifentanil requirement and relieved pain in CS for TAVI.Methods and Results: This prospective study randomized 72 patients scheduled for elective TAVI under CS into 2 groups, with (FIB) and without (control) FIB (n=36 in each group). The sedation targeted a Bispectral Index <90 with a Richmond Agitation-Sedation Scale of -2 to -1. Dexmedetomidine (0.7 µg/kg, i.v.) combined with remifentanil (0.03 µg/kg/min, i.v.) and propofol (0.3 mg/kg/h, i.v.) was used to commence sedation. FIB using 30 mL of 0.185% ropivacaine was implemented 2 min before TAVI. Patient sedation was maintained with dexmedetomidine (0.4 µg/kg/h, i.v.) supplemented with remifentanil (0-0.02 µg/kg/min, i.v.). Remifentanil (20 µg, i.v.) was used as a rescue dose for intraprocedural pain. Compared with the control group, FIB reduced the both the total (median [interquartile range] 83.0 [65.0-98.0] vs. 34.5 [26.0/45.8)] µg; P<0.001) and continuous (25.3 [20.9/31.5] vs. 9.5 [6.8/12.5] ng/kg/min; P<0.001) doses of remifentanil administered. CONCLUSIONS: FIB reduced the remifentanil requirement and relieved pain in patients undergoing TAVI with CS. Therefore, FIB improved the quality of CS in TAVI.

18.
J Med Case Rep ; 16(1): 349, 2022 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-36180925

RESUMO

BACKGROUND: Persistent descending mesocolon, an anomaly of fixation of the mesentery of the descending colon, can sometimes cause complications such as intestinal obstruction and intussusception. We present the first reported case of sigmoid volvulus with persistent descending mesocolon. CASE PRESENTATION: An 82-year-old Japanese man had intermittent lower abdominal pain. Abdominal computed tomography showed dilation and a shift to the right side of the sigmoid colon, but no findings of volvulus. The next day, he presented continuous lower abdominal pain with bloody stool. A second abdominal computed tomography showed strangulation and dilation of the sigmoid colon, with shift from the right side of the abdominal cavity to the pelvic space. This suggested the descending colon was running to the medial side with sigmoid volvulus. Emergency surgery was performed for volvulus with persistent descending mesocolon. Operative findings revealed dilation of the sigmoid colon with a partial poorly colored region and strangulation that caused volvulus. After releasing the strangulation of the sigmoid colon, the descending colon was revealed to be running more to the medial side, with adherence to small intestinal mesentery. There was no Toldt's fusion fascia at the descending colon. Persistent descending mesocolon was therefore diagnosed due to abnormality of fixation of the descending colon. The sigmoid colon, including the poorly colored region, was resected and reconstructed, while the inferior mesenteric and left colonic arteries were preserved because of the complexity of the vascular system running around the descending and sigmoid colon due to the shortened mesentery. These findings were pathologically compatible with circulatory compromise and intestinal degeneration due to sigmoid volvulus. The patient had no complications after discharge, including in relation to defecation. CONCLUSION: Persistent descending mesocolon can occasionally cause acute abdominal symptoms requiring immediate treatment. A computed tomography finding of the descending colon running more to the medial side than ordinary cases can aid diagnosis of persistent descending mesocolon.


Assuntos
Abdome Agudo , Volvo Intestinal , Laparoscopia , Mesocolo , Dor Abdominal/etiologia , Dor Abdominal/cirurgia , Idoso de 80 Anos ou mais , Colo Sigmoide/diagnóstico por imagem , Colo Sigmoide/cirurgia , Humanos , Volvo Intestinal/diagnóstico , Volvo Intestinal/diagnóstico por imagem , Laparoscopia/métodos , Masculino , Mesocolo/anormalidades , Mesocolo/diagnóstico por imagem , Mesocolo/cirurgia
19.
Surg Open Sci ; 8: 69-74, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35463847

RESUMO

Background: The population affected by colorectal cancer is growing, and there is an increasing need for prevention of functional decline following treatment. We proposed that the Kihon Checklist published by the Japanese Ministry of Health, Labor, and Welfare would be an appropriate means of frailty assessment for prediction of postoperative complications in older patients with colorectal cancer. This prospective cohort study aims to identify the factors influencing postoperative frailty. Methods: We prospectively enrolled consecutive patients with colorectal cancer and aged ≥ 65 year (N = 500) between May 2017 and December 2018. Eligible patients were assessed with the Kihon Checklist prior to surgery and 30 days after surgery. The main measures were variables related to postoperative change in view of frail status. Results: According to the Kihon Checklist questionnaire, 164 patients were frail preoperatively and 172 patients were frail postoperatively, whereas 38 patients changed from "nonfrail" before surgery to postoperative "frail." Overall complications were counted in 97 patients (19.4%), and 5 patients died. Performance status ≥ 2, history of laparotomy, open surgery, complication, ostomy creation, and delirium were significantly associated with changing postoperative "frail" (P = .014, P = .023, P = .006, P < .001, P = .023, and P = .024, respectively). In multivariate analysis, independent related factors of changing postoperative "frail" were complication (odds ratio 2.69, 95% confidence interval 1.19-6.09, P = .018) and ostomy creation (odds ratio 2.32, 95% confidence interval 1.01-5.33, P = .047). Conclusion: The Kihon Checklist questionnaire could identify the factors related to postoperative change of frailty status in older patients with colorectal cancer. This cohort concluded that whether postoperative complication occurred or not was closely associated with perioperative change of frailty status.

20.
Hypertens Res ; 45(6): 1008-1017, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35418609

RESUMO

Blood pressure variability (BPV) is an important indicator in risk stratification for hypertension. Among the daily BPVs assessed using a 24-h ambulatory blood pressure (BP) monitor nocturnal systolic BPV has been suggested to predict cardiovascular risks. We hypothesized that very short-term BPV at rest would correlate with nocturnal BPV because of the shared autonomic BP regulatory system under no daily exertion. Thirty untreated normotensive and hypertensive adults underwent 30-min continuous beat-by-beat BP recordings in the supine position, followed by 24-h ambulatory blood pressure monitoring (ABPM). The relationship between very short-term BPV (standard deviation (SD), coefficient of variation (CV)) and daytime and nocturnal BPV (SD, CV, average real variability (ARV), and standardized ARV (CV-ARV)) was assessed with Pearson's correlation coefficients. Very short-term BPV correlated significantly with nocturnal BPV (ARV, r = 0.604, p < 0.001) but not with daytime BPV. These trends were more pronounced with the increasing data length of continuous beat-by-beat BP recording. Using a data segment from the last 10 min of a 30-min continuous beat-by-beat BP recording resulted in a stronger correlation between very short-term BPV and nocturnal BPV than using earlier segments. The findings of this study suggest that very short-term BPV in the supine position at rest may predict nocturnal BPV. Since the burden of ABPM for patients has hindered clinical dissemination, very short-term BPV has the potential to develop a novel index of BPV.


Assuntos
Monitorização Ambulatorial da Pressão Arterial , Hipertensão , Adulto , Sistema Nervoso Autônomo , Pressão Sanguínea/fisiologia , Monitorização Ambulatorial da Pressão Arterial/métodos , Feminino , Humanos , Hipertensão/diagnóstico , Gravidez , Decúbito Dorsal
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA