Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Res Sq ; 2023 Nov 30.
Artigo em Inglês | MEDLINE | ID: mdl-38077018

RESUMO

Purpose: Combined micro-PET/CT scanners are widely employed to investigate models of brain disorders in rodents using PET-based coregistration. We examined if CT-based coregistration could improve estimates of brain dimensions and consequently estimates of nondisplaceable binding potential (BPND) in rodent PET studies. Procedures: PET and CT scans were acquired on 5 female and 5 male CD-1 mice with PET and CT scans were acquired on 5 female and 5 male CD-1 mice with 3-[18F]fluoro-5-(2-pyridinylethynyl)benzonitrile ([18F]FPEB), a radiotracer for the metabotropic glutamate receptor subtype 5 (mGluR5). In the proposed PET/CT (PTCT) approach, the tracer-specific standard volume was dimension-customized to each animal using the scaling factors from CT-to-standard CT coregistration to simplify PET-to-standard PET coregistration (i.e., 3 CT- and 6 PET-derived parameters). For comparison, conventional PET-based coregistration was performed with 9 (PT9) or 12 (PT12) parameters. PET frames were transferred to the standard space by the three approaches (PTCT, PT9, and PT12) to obtain regional time-activity curves (TACs) and BPND in 14 standard volumes of interest (VOIs). Lastly, CT images of the animals were transferred to the standard space by CT-based parameters from PTCT and with the scaling factors replaced with those from PET-based PT9 to evaluate agreement of the skull to the standard CT. Results: The PET-based approaches showed various degrees of underestimations of scaling factors in the posterior-anterior-direction compared to PTCT, which resulted in negatively proportional overestimation of radioactivity in the cerebellum (reference region) up to 20%, and proportional, more prominent underestimation of BPND in target regions down to -50%. The skulls of individual animals agreed with the standard skull for scaling factors from PTCT but not for the scaling factors from PT9, which suggested inaccuracy of the latter. Conclusions: The results indicated that conventional PET-based coregistration approaches could yield biased estimates of BPND due to erroneous estimates of brain dimensions when applied to tracers for which the cerebellum serves as reference region. The proposed PTCT provides evidence of a quantitative improvement over PET-based approaches for brain studies using micro-PET/CT scanners.

2.
J Nucl Med ; 59(12): 1869-1876, 2018 12.
Artigo em Inglês | MEDLINE | ID: mdl-29728519

RESUMO

11C-RO-963, 11C-RO-643, and 18F-RO-948 (previously referred to as 11C-RO6924963, 11C-RO6931643, and 18F-RO6958948, respectively) have been reported as promising PET tracers for tau imaging based on in vitro and preclinical PET data. Here we describe the first, to our knowledge, human evaluation of these novel radiotracers. Methods: Amyloid PET-positive Alzheimer disease (AD) subjects and younger controls each received 2 different tau tracers. Dynamic 90-min scans were obtained after bolus injection of 11C-RO-963, 11C-RO-643, or 18F-RO-948. Arterial blood sampling was performed on 11 healthy controls and 11 AD subjects. Regions were defined on MR images, and PET data were quantified by plasma reference graphical analysis (for total distribution volume) and target cerebellum ratio (SUV ratios of 60- to 90-min frames). SUV ratio images were also analyzed voxelwise. Five older controls each underwent 2 scans with 18F-RO-948 for evaluation of test-retest variability. Four AD subjects underwent a repeated 18F-RO-948 scan 6-22 mo after the first scan. Six additional healthy controls (3 men and 3 women; age range, 41-67 y) each underwent 1 whole-body dosimetry scan with 18F-RO-948. Results: In younger controls, SUVpeak was observed in the temporal lobe with values of approximately 3.0 for 11C-RO-963, 1.5 for 11C-RO-643, and 3.5 for 18F-RO-948. Over all brain regions and subjects, the trend was for 18F-RO-948 to have the highest SUVpeak, followed by 11C-RO-963 and then 11C-RO-643. Regional analysis of SUV ratio and total distribution volume for 11C-RO-643 and 18F-RO-948 clearly discriminated the AD group from the healthy control groups. Compartmental modeling confirmed that 11C-RO-643 had lower brain entry than either 11C-RO-963 or 18F-RO-948 and that 18F-RO-948 showed better contrast between (predicted) areas of high versus low tau accumulation. Thus, our subsequent analysis focused on 18F-RO-948. Both voxelwise and region-based analysis of 18F-RO-948 binding in healthy controls versus AD subjects revealed multiple areas where AD subjects significantly differed from healthy controls. Of 22 high-binding regions, 13 showed a significant group difference (after ANOVA, F(1,21) = 45, P < 10-5). Voxelwise analysis also revealed a set of symmetric clusters where AD subjects had higher binding than healthy controls (threshold of P < 0.001, cluster size > 50). Conclusion:18F-RO-948 demonstrates characteristics superior to 11C-RO-643 and 11C-RO-963 for characterization of tau pathology in AD. Regional binding data and kinetic properties of 18F-RO-948 compare favorably with other existing tau PET tracers.


Assuntos
Doença de Alzheimer/diagnóstico por imagem , Doença de Alzheimer/metabolismo , Tomografia por Emissão de Pósitrons/métodos , Compostos Radiofarmacêuticos , Proteínas tau/metabolismo , Adulto , Idoso , Encéfalo/diagnóstico por imagem , Encéfalo/metabolismo , Mapeamento Encefálico , Radioisótopos de Carbono , Estudos de Casos e Controles , Feminino , Radioisótopos de Flúor , Humanos , Masculino , Pessoa de Meia-Idade , Doses de Radiação , Ensaio Radioligante , Compostos Radiofarmacêuticos/farmacocinética , Distribuição Tecidual
3.
Int J Neuropsychopharmacol ; 21(7): 656-667, 2018 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-29522184

RESUMO

Background: The α7 nicotinic acetylcholine receptor increasingly has been implicated in normal brain physiology, as well as in neuropsychiatric disorders. The highly cortical distribution of α7 nicotinic acetylcholine receptor suggests a role in cognition. Methods: We expanded the first-in-human PET imaging of α7 nicotinic acetylcholine receptor with [18F]ASEM from 5 to 21 healthy nonsmoking volunteers and added a feasibility study in 6 male patients with schizophrenia. Study aims included: (1) confirmation of test-retest reproducibility of [18F]ASEM binding, (2) demonstration of specificity by competition with DMXB-A, an α7 nicotinic acetylcholine receptor partial agonist, (3) estimation of [18F]ASEM binding potentials and α7 nicotinic acetylcholine receptor density in vivo in humans, and (4) demonstrating the feasibility of studying α7 nicotinic acetylcholine receptor as a target for schizophrenia. Results: Test-retest PET confirmed reproducibility (>90%) (variability ≤7%) of [18F]ASEM volume of distribution (VT) estimates in healthy volunteers. Repeated sessions of PET in 5 healthy subjects included baseline and effect of inhibition after oral administration of 150 mg DMXB-A. From reduction of binding potentials, we estimated the dose-dependent occupancy of α7 nicotinic acetylcholine receptor by DMXB-A at 17% to 49% for plasma concentrations at 60 to 200 nM DMXB-A. In agreement with evidence postmortem, α7 nicotinic acetylcholine receptor density averaged 0.67 to 0.82 nM and inhibitor affinity constant averaged 170 to 385 nM. Median VT in a feasibility study of 6 patients with schizophrenia was lower than in healthy volunteers in cingulate cortex, frontal cortex, and hippocampus (P = 0.02, corrected for multiple comparions, Mann-Whitney test). Conclusions: The current results confirm the reproducibility of [18F]ASEM VT estimates and the specificity of the tracer for α7 nicotinic acetylcholine receptor. Preliminary findings from our feasibility study of [18F]ASEM binding in patients with schizophrenia are suggestive and provide guidance for future studies with more subjects.


Assuntos
Compostos Azabicíclicos/farmacocinética , Encéfalo/metabolismo , Óxidos S-Cíclicos/farmacocinética , Tomografia por Emissão de Pósitrons/normas , Esquizofrenia/metabolismo , Receptor Nicotínico de Acetilcolina alfa7/metabolismo , Adolescente , Adulto , Encéfalo/diagnóstico por imagem , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Tomografia por Emissão de Pósitrons/métodos , Reprodutibilidade dos Testes , Esquizofrenia/diagnóstico por imagem , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA