Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 86
Filtrar
1.
Circ Rep ; 5(11): 415-423, 2023 Nov 10.
Artigo em Inglês | MEDLINE | ID: mdl-37969232

RESUMO

Background: There is a strong demand for remote monitoring systems to gather health data. This study investigated the safety, usefulness, and patient satisfaction in outpatient care using telehealth with real-time electrocardiogram (ECG) monitoring after catheter ablation. Methods and Results: In all, 38 patients who underwent catheter ablation were followed up using telehealth. At the 3- and 6-month follow-up, a self-fitted Duranta ECG monitoring device was sent to the patient's home before the online consultation. Patients attached the devices themselves, and the doctors viewed the patients by video chat and performed real-time ECG monitoring. The frequency of hospital visits and the ECG monitoring duration were compared with conventional in-person follow-up data (n=102). The completion rate for telehealth follow-up was 32 of 38 patients (84%). The number of hospital visits during the 6 months was significantly lower with telehealth follow-up than with conventional follow-up (median [interquartile range] 1 [1-1] vs. 5 [3-5]; P<0.0001). However, the ECG monitoring duration was approximately 4-fold longer for the telehealth follow-up (median [interquartile range] 89 [64-117] vs. 24 [0.1-24] h; P<0.0001). No major adverse events were observed during the telehealth follow-up. Patient surveys showed high satisfaction with telehealth follow-up due to reduced hospital visits. Conclusions: A combination of telehealth follow-up with real-time ECG monitoring increased the ECG monitoring duration and patient satisfaction without any adverse events.

3.
J Cardiovasc Electrophysiol ; 34(7): 1569-1576, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37313805

RESUMO

INTRODUCTION: Intermuscular implantations of subcutaneous implantable cardioverter-defibrillators (S-ICD) have been recommended, but the position of the anterior border of the latissimus dorsi muscle (LDM) has not previously been evaluated in establishing an incision line to facilitate the intermuscular approach. The objective of this study is to evalua the position and trend of the anterior border of the LDM in patients who are candidates for implantable cardioverter-defibrillators. METHODS: The distance from the back to the anterior border of the LDM (A) and the anterior-posterior width of the chest wall (B) were measured on computed tomography retrospectively, and the ratio (=A/B) was used as the position of the anterior border of the LDM. In addition, the variability and factors affecting the values were evaluated. RESULTS: An analysis was performed on 78 patients, and the position of the anterior border of the LDM (=A/B) exhibited a normal distribution, with a mean value of 0.53 ± 0.062 (0.41-0.69). The position of the anterior border of the LDM tended to be more anterior in younger, taller, male, primary prevention, nonheart failure, low brain natriuretic peptide level, and nondiabetic patients. CONCLUSION: The position of the anterior border of the LDM varied from case to case with variable results. Conventional incisions on the midaxillary line may be inappropriate for intermuscular implantations, and the position of the anterior border of the LDM should be evaluated in each individual case to establish the incision line.


Assuntos
Desfibriladores Implantáveis , Músculos Superficiais do Dorso , Ferida Cirúrgica , Humanos , Masculino , Músculos Superficiais do Dorso/diagnóstico por imagem , Músculos Superficiais do Dorso/cirurgia , Estudos Retrospectivos , Resultado do Tratamento , Implantação de Prótese/efeitos adversos , Implantação de Prótese/métodos
5.
Clin Case Rep ; 11(3): e7155, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36998327

RESUMO

Knowing the vascular anatomy of the common femoral artery bifurcation and ultrasound-guided puncture, including doppler, is helpful in recognizing anatomic variations and avoiding complications.

6.
J Arrhythm ; 39(1): 52-60, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36733320

RESUMO

Background: Ventricular tachycardia (VT) non-inducibility at the end of ablation is associated with a less likely VT recurrence. However, it is not clear whether we should use VT non-inducibility as a routine end point of VT ablation. The aim of this study was to evaluate VT recurrence in patients in whom VT non-inducibility was not achieved at the end of the radiofrequency (RF) ablation and the factors attributing to the VT recurrence. Methods: We analyzed that 62 patients in whom VT non-inducibility was not achieved at the end of the RF ablation were studied. Results: Over 2 years, 22 (35%) of the cases had VT recurrences. A multivariate analysis showed that an LVEF ≥35% (HR: 0.19; 95% CI: 0.06-0.49; p < .01) and elimination of the clinical VT as an acute ablation efficacy (HR: 0.23; 95% CI: 0.04-0.81; p = .02) were independent predictors of fewer VT recurrences. RF ablation was associated with a 91.1% reduction in VT episodes. Conclusion: Even if VT non-inducibility was not achieved, patients with an LVEF ≥35% or in whom the clinical VT could be eliminated might be prevented from having VT recurrences. The validity of the VT non-inducibility of any VT should be evaluated considering each patient's background and the results of the procedure.

7.
J Cardiovasc Electrophysiol ; 34(3): 527-535, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36598438

RESUMO

BACKGROUND: Lesion gaps assessed by late-gadolinium enhancement magnetic resonance imaging (LGE-MRI) are associated with the atrial fibrillation (AF) recurrence after pulmonary vein isolation. Animal studies have demonstrated that the catheter-contact force (CF), stability, and orientation are strongly associated with lesion formation. However, the impact of those procedural factors on the lesion characteristics associated with AF recurrence has not been well discussed. METHODS: A total of 30 patients with paroxysmal AF who underwent catheter ablation were retrospectively enrolled. Radiofrequency (RF) applications were performed with 35 W for 30 s in a point-by-point fashion under esophageal temperature monitoring. The inter-lesion distance was 4 mm. The lesions were visualized by LGE-MRI 3 months postprocedure and assessed by the LGE volume (ml), gap number (GN), and average gap length (AGL [mm]). The gaps were defined as nonenhancement sites of >4 mm. The procedural factors including the catheter-CF, stability, and orientation were calculated on the NavX system. RESULTS: Six (20%) of 30 patients had AF recurrences 12 months postablation. A univariate analysis demonstrated that the AGL was associated with AF recurrence (hazard ratio [HR]: 1.20, confidence interval [CI]: 1.03-1.42, p = .02). All AF recurrence were found in patients with an AGL of >7 mm. The catheter-CF and stability were associated with an AGL of >7 mm, but not the orientation (CF-HR: 0.62, CI: 0.39-0.97, p = .038; stability-HR: 0.8, CI: 0.66-0.98, p = .027). CONCLUSIONS: RF ablation with a low CF and poor catheter stability has a potential risk of creating large lesion gaps associated with AF recurrence.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Fibrilação Atrial/cirurgia , Meios de Contraste , Gadolínio , Estudos Retrospectivos , Imageamento por Ressonância Magnética/métodos , Ablação por Cateter/métodos , Recidiva , Veias Pulmonares/cirurgia , Átrios do Coração , Resultado do Tratamento
8.
Europace ; 25(2): 600-609, 2023 02 16.
Artigo em Inglês | MEDLINE | ID: mdl-36504238

RESUMO

AIMS: Accessory pathway (AP) ablation is a standard procedure for the treatment of Wolff-Parkinson-White syndrome (WPW). Twelve-lead electrocardiogram (ECG)-based delta wave analysis is essential for predicting ablation sites. Previous algorithms have shown to be complex, time-consuming, and unprecise. We aimed to retrospectively develop and prospectively validate a new, simple ECG-based algorithm considering the patients' heart axis allowing for exact localization of APs in patients undergoing ablation for WPW. METHODS AND RESULTS: Our multicentre study included 211 patients undergoing ablation of a single manifest AP due to WPW between 2013 and 2021. The algorithm was developed retrospectively and validated prospectively by comparing its efficacy to two established ones (Pambrun and Arruda). All patients (32 ± 19 years old, 47% female) underwent successful pathway ablation. Prediction of AP-localization was correct in 197 patients (93%) (sensitivity 92%, specificity 99%, PPV 96%, and NPV 99%). Our algorithm was particularly useful in correctly localizing antero-septal/-lateral (sensitivity and specificity 100%) and posteroseptal (sensitivity 98%, specificity 92%) AP in proximity to the tricuspid valve. The accuracy of EASY-WPW was superior compared to the Pambrun (93% vs. 84%, P = 0.003*) and the Arruda algorithm (94% vs. 75%, P < 0.001*). A subgroup analysis of children (n = 58, 12 ± 4 years old, 55% female) revealed superiority to the Arruda algorithm (P < 0.001*). The reproducibility of our algorithm was excellent (Ï°>0.8; P < 0.001*). CONCLUSION: The novel EASY-WPW algorithm provides reliable and accurate pre-interventional ablation site determination in WPW patients. Only two steps are necessary to locate left-sided AP, and three steps to determine right-sided AP.


Assuntos
Feixe Acessório Atrioventricular , Ablação por Cateter , Síndrome de Wolff-Parkinson-White , Humanos , Adulto , Criança , Feminino , Adolescente , Adulto Jovem , Pessoa de Meia-Idade , Masculino , Síndrome de Wolff-Parkinson-White/diagnóstico , Síndrome de Wolff-Parkinson-White/cirurgia , Estudos Retrospectivos , Reprodutibilidade dos Testes , Ablação por Cateter/métodos , Feixe Acessório Atrioventricular/diagnóstico , Feixe Acessório Atrioventricular/cirurgia , Eletrocardiografia/métodos , Algoritmos
9.
JACC Case Rep ; 4(23): 101464, 2022 Dec 07.
Artigo em Inglês | MEDLINE | ID: mdl-36507289

RESUMO

The management of heart rhythm disorders in patients with adult congenital heart disease and limited vascular access is challenging. We present the case of a 38-year-old woman with Ebstein's anomaly who underwent implantation of a combination of a leadless pacemaker and a subcutaneous implantable cardioverter-defibrillator to manage fatal arrhythmias. (Level of Difficulty: Intermediate.).

10.
J Arrhythm ; 38(6): 1056-1062, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36524047

RESUMO

Background: It is uncertain whether cardiac resynchronization therapy with a defibrillator (CRT-D) provides better survival benefits than a CRT-pacemaker (CRT-P) in heart failure patients with a reduced ejection fraction (≦35%, HFrEF) treated with contemporary HF therapy. Methods: We retrospectively analyzed the ventricular arrhythmia (VAs; sustained ventricular tachycardia/fibrillation) events in HFrEF patients who underwent CRT without a prior history of VAs or aborted sudden cardiac death before the CRT implantation. Between January/2010 and December/2020, a CRT device was implanted in 79 HFrEF patients (mean age: 69 ± 12 years, male: 57, ischemic cardiomyopathy: 16). CRT-D and CRT-P devices were implanted in 50 and 29 patients, respectively, at each physician's discretion. CRT-Ds were indicated in younger patients than were CRT-Ps (66 ± 12 vs. 73 ± 12 years, p = 0.03), but the gender distribution did not differ (female, 24% [12 of 50] vs. 35% [10 of 29], p = 0.44). The VA events during a median follow-up of 3.5-years (interquartile range [IQR]:1.6-5.5) and their predictors were analyzed. Results: VA events occurred in 9 patients with CRT-Ds (18%) and one with a CRT-P (3%, p = 0.08). The VA event rate was significantly lower in patients without a prior non-sustained ventricular tachycardia (NSVT: ≥3 beats; rate, ≥120 bpm; lasting <30 s, HR 0.05; 95% CI 0.01-0.30; p < 0.01) and females (HR 0.11; 95% CI 0.01-0.93; p = 0.04). Of note, no female patients without a prior history of NSVT experienced VA events. Conclusion: HFrEF CRT candidates without a prior history of NSVT and females may obtain less benefit from a primary preventive defibrillator indication.

11.
Circ J ; 87(1): 29-40, 2022 12 23.
Artigo em Inglês | MEDLINE | ID: mdl-35989301

RESUMO

BACKGROUND: The mechanism underlying the sex differences in atrial fibrillation (AF) recurrence following pulmonary vein (PV) isolation is not fully understood. We hypothesized that non-PV foci and epicardial adipose tissue (EAT) play a key role.Methods and Results: Data from 304 consecutive patients (75% males) who underwent contrast-enhanced computed tomography and catheter ablation of AF were reviewed. The EAT around the atrium was measured separately in 4 parts of the atrium. All patients underwent high-dose isoproterenol infusions to assess the non-PV foci. Significantly more non-PV foci and less EAT around the atrium were observed in female patients than in male patients. In males, those with non-PV foci on the left atrial (LA) anterior wall had significantly greater EAT for the same lesions than those without non-PV foci. During a median follow-up of 27 months, the predictors of AF recurrence after first catheter ablation were female sex, presence of non-PV foci, LA diameter, and septal EAT index. A sex-specific analysis revealed that LA diameter was a predictor only in males and that the presence of non-PV foci in the septal region was a strong predictor in males (hazard ratio [HR]: 2.24) and females (HR: 3.65). CONCLUSIONS: Sex-specific differences were observed in non-PV foci sites and local EAT and in regard to the predictors of AF recurrence.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Masculino , Feminino , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Caracteres Sexuais , Resultado do Tratamento , Recidiva , Átrios do Coração , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Ablação por Cateter/métodos , Tecido Adiposo/diagnóstico por imagem
12.
Am J Cardiol ; 181: 59-65, 2022 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-35973835

RESUMO

This study sought to assess the left atrial (LA) functional recovery after radiofrequency catheter ablation (RFCA) for atrial fibrillation (AF) and to evaluate the determining factor of procedural success of RFCA, using a novel preload stress echocardiography. A total of 111 patients with AF were prospectively recruited. The echocardiographic parameters were obtained during the leg-positive pressure (LPP) maneuver, both at baseline and midterm after RFCA. As an index of LA distensibility, the LA expansion index was calculated as (LAVmax - LAVmin) × 100 / LAVmin. During a median follow-up period of 14.2 months, AF recurrence was observed in 23 patients (20.7%). In LA functional parameters at baseline, only the Δ LA expansion index was significantly larger in the success group (16 ± 11% vs 4 ± 9%, p <0.05). At midterm follow-up, the Δ LA expansion index significantly increased to 32 ± 19% (p <0.05), together with structural LA reverse remodeling only in the success group. Moreover, the Δ stroke volume index during the LPP stress test significantly increased only in the success group (from 2.3 ± 1.3 ml/m2 to 3.1 ± 4.8 ml/m2, p <0.05). In a multivariate analysis, left ventricular ejection fraction (hazard ratio 0.911, p <0.05) and baseline Δ LA expansion index (hazard ratio 0.827, p <0.001) were independent predictors of AF recurrence. In conclusion, the baseline Δ LA expansion index during LPP stress is a reliable marker for predicting procedural success after RFCA. Moreover, maintenance of sinus rhythm resulted in an improvement of the preload reserve after RFCA.


Assuntos
Fibrilação Atrial , Remodelamento Atrial , Ablação por Cateter , Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Átrios do Coração/diagnóstico por imagem , Humanos , Recidiva , Volume Sistólico , Resultado do Tratamento , Função Ventricular Esquerda
13.
J Arrhythm ; 38(3): 400-407, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35785370

RESUMO

Background: Corticosteroids are widely used in patients with cardiac sarcoidosis (CS). In addition, upgrading to cardiac resynchronization therapy (CRT) is sometimes needed. This study aimed to investigate the impact of corticosteroid use on the clinical outcomes following CRT upgrades. Methods: A total of 48 consecutive patients with non-ischemic cardiomyopathies who underwent CRT upgrades were retrospectively reviewed and divided into three groups: group 1 included CS patients taking corticosteroids before the CRT upgrade (n = 7), group 2, CS patients not taking corticosteroids before the CRT upgrade (n = 10), and group 3, non-CS patients (n = 31). The echocardiographic response, heart failure hospitalizations, and cardiovascular deaths were evaluated. Results: The baseline characteristics during CRT upgrades exhibited no significant differences in the echocardiographic data between the three groups. After the CRT upgrade, responses regarding the ejection fraction (EF) and end-systolic volume (ESV) were significantly lower in CS patients than non-CS patients (ΔEF: group 1, 6.7% vs. group 2, 7.7% vs. group 3, 13.6%; p = .039, ΔESV: 3.0 ml vs. -12.7 ml vs. -37.2 ml; p = .008). The rate of an echocardiographic response was lowest in group 1 (29%). There were, however, no significant differences in the cumulative freedom from a composite outcome among the three groups (p = .19). No cardiovascular deaths occurred in group 1. Conclusion: The echocardiographic response to an upgrade to CRT and the long-term prognosis in patients with CS should be carefully evaluated because of the complex etiologies and impact of immunosuppressive therapy.

14.
J Cardiovasc Electrophysiol ; 33(8): 1847-1856, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35761749

RESUMO

INTRODUCTION: The skin overlying cardiovascular implantable electronic devices (CIEDs) sometimes becomes very thin after implantations, which could cause a device erosion. The factors related to the skin thickness of device pockets have not been elucidated. This study aimed to evaluate the skin thickness of CIED pockets and search for the factors associated with the thickness. METHODS: Seventeen skin thickness points around the CIED pocket were measured through ultrasonography in each patient. RESULTS: A total of 101 patients (76 ± 11 years, 26 female) were enrolled. The median duration from the implantation to the examination was 95 months (quartile: 52.5-147.5). The median skin thickness overlying the device was 4.1 mm (3.3-5.9). Patients with heart failure and malignancy had thinner skin overlying the CIED than those without. A significant correlation existed between skin thickness and body mass index (BMI), hemoglobin, serum creatinine, estimated glomerular filtration rate (eGFR), and left ventricular ejection fraction. In contrast, age, gender, and device size did not exhibit a significant correlation with skin thickness. A multivariate logistic regression analysis revealed that chronic heart failure and a decrease in the eGFR and BMI were independent predictive factors of "very thin (≦3.3 mm)" skin of the CIED pocket late after an implantation. CONCLUSION: Aside from a low BMI, the comorbidities (low hemoglobin, heart failure, and renal dysfunction) had a stronger impact on the skin thickness overlying the device than the device size. A careful observation of the device pocket should be performed in patients with those risk factors.


Assuntos
Desfibriladores Implantáveis , Insuficiência Cardíaca , Marca-Passo Artificial , Infecções Relacionadas à Prótese , Desfibriladores Implantáveis/efeitos adversos , Eletrônica , Feminino , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/etiologia , Humanos , Marca-Passo Artificial/efeitos adversos , Infecções Relacionadas à Prótese/diagnóstico , Estudos Retrospectivos , Volume Sistólico , Função Ventricular Esquerda
15.
J Arrhythm ; 38(2): 221-231, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35387140

RESUMO

Background: Some of atrial fibrillation (AF) drivers are found in normal/mild late-gadolinium enhancement (LGE) areas, as well as moderate ones. The atrial wall thickness (AWT) has been reported to be important as a possible AF substrate. However, the AWT and degree of LGEs as an AF substrate has not been fully validated in humans. Objective: The purpose of this study was to evaluate the impact of the AWT in normal/mild LGE areas on AF drivers. Methods: A total of 287 segments in 15 persistent AF patients were assessed. AF drivers were defined as non-passively activated areas (NPAs), where rotational activation was frequently observed, and were detected by the novel real-time phase mapping (ExTRa Mapping), mild LGE areas were defined as areas with a volume ratio of the enhancement voxel of 0% to <10%. The AWT was defined as the minimum distance from the manually determined endocardium to the epicardial border on the LGE-MRI. Results: NPAs were found in 20 (18.0%) of 131 normal/mild LGE areas where AWT was significantly thicker than that in the passively activated areas (PAs) (2.5 ± 0.3 vs. 2.2 ± 0.3 mm, p < .001). However, NPAs were found in 41 (26.3%) of 156 moderate LGE areas where AWT was thinner than that of PAs (2.1 ± 0.2 mm vs. 2.23 ± 0.3 mm, p = .02). An ROC curve analysis yielded an optimal cutoff value of 2.2 mm for predicting the presence of an NPA in normal/mild LGE areas. Conclusion: The location of AF drivers in normal/mild LGE areas might be more accurately identified by evaluating AWT.

16.
Circ J ; 86(8): 1273-1280, 2022 07 25.
Artigo em Inglês | MEDLINE | ID: mdl-35387940

RESUMO

BACKGROUND: Several algorithms have been proposed for differentiating the right and left outflow tracts (RVOT/LVOT) arrhythmia origins from 12-lead electrocardiograms (ECGs); however, the procedure is complicated. A deep learning (DL) model, a form of artificial intelligence, can directly use ECGs and depict the importance of the leads and waveforms. This study aimed to create a visualized DL model that could classify arrhythmia origins more accurately.Methods and Results: This study enrolled 80 patients who underwent catheter ablation. A convolutional neural network-based model that could classify arrhythmia origins with 12-lead ECGs and visualize the leads that contributed to the diagnosis using a gradient-weighted class activation mapping method was developed. The average prediction results of the origins by the DL model were 89.4% (88.2-90.6) for accuracy and 95.2% (94.3-96.2) for recall, which were significantly better than when a conventional algorithm is used. The ratio of the contribution to the prediction differed between RVOT and LVOT origins. Although leads V1 to V3 and the limb leads had a focused balance in the LVOT group, the contribution ratio of leads aVR, aVL, and aVF was higher in the RVOT group. CONCLUSIONS: This study diagnosed the arrhythmia origins more accurately than the conventional algorithm, and clarified which part of the 12-lead waveforms contributed to the diagnosis. The visualized DL model was convincing and may play a role in understanding the pathogenesis of arrhythmias.


Assuntos
Ablação por Cateter , Aprendizado Profundo , Taquicardia Ventricular , Complexos Ventriculares Prematuros , Inteligência Artificial , Ablação por Cateter/efeitos adversos , Eletrocardiografia/métodos , Ventrículos do Coração , Humanos , Complexos Ventriculares Prematuros/diagnóstico
17.
Clin Case Rep ; 9(6): e04198, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-34691467

RESUMO

Atrial tachycardia (AT) in the right atrium often occurs following open-heart surgery. Catheter ablation for these AT is challenging and can lead to unintended conduction block. We performed late-gadolinium enhancement magnetic resonance imaging (LGE-MRI) prior to catheter ablation and predicted wavefront propagation during SR as well as the slow conduction zone during tachycardia. LGE-MRI may assist predicting the conduction disturbance and reducing the risk of unexpected sinus exit block.

18.
Pacing Clin Electrophysiol ; 44(11): 1874-1883, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34455601

RESUMO

BACKGROUND: A substantial number of patients with shock devices (implantable cardioverter defibrillators [ICDs] or ICDs with resynchronization [CRTDs]) experience psychological distress. OBJECTIVE: We investigated the device nurse telephone intervention's effect on improving the patient's adaptation to shock devices, quality of life (QOL), and anxiety in the remote monitoring era. METHODS: The patient's adaptation to the device, health-related QOL, and anxiety were investigated by the modified Implanted Devices Adjustment-Japan score (IDAS), Short Form-36, and State-Trait Anxiety Inventory (STAI) before and 1-year after the device nurse telephone intervention, performed every 3 months. A total of 95 patients (median age 69 years and 25 females) participated. Sixty patients had ICDs and 35 CRTDs. Structural heart disease was observed in 72 patients, and idiopathic ventricular arrhythmias in the others. The mean left ventricular ejection fraction was 46% ± 15%. The median duration since the device implantation was 5.2 years. RESULTS: The total IDAS score significantly improved from 28.42 ± 7.11 at baseline to 26.77 ± 7.68 (p = 0.0076) at 1 year. Both the state and trait anxiety significantly improved (from 38.9 ± 9.6 to 35.3 ± 9.0 [<0.0001] and 38.8 ± 10.3 to 36.2±9.8 [p = 0.0044], respectively). The prevalence of patients with a state and trait anxiety of more than 40 decreased from 44 (46%) and 38 (40%) patients before the study to 27 (28 %) and 32 (34 %) at 1 year. The SF-36 mental component summary score significantly increased (50.8 ± 8.3 at baseline to 53.1 ± 7.7 at 1 year, p = 0.0031). CONCLUSIONS: The device nurse intervention facilitated the patient's adaptation to the shock device, increased the health-related QOL, and reduced the patient's anxiety.


Assuntos
Adaptação Fisiológica , Terapia de Ressincronização Cardíaca/enfermagem , Desfibriladores Implantáveis , Qualidade de Vida , Tecnologia de Sensoriamento Remoto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
19.
Clin Case Rep ; 9(6): e04169, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-34194766

RESUMO

A 61-year-old female with 50 000 ventricular premature contractions and a reduced left ventricular ejection fraction of 35% was referred to our center. Although the origin was considered to originate from the junction between the left and right coronary cusp, a single radiofrequency application above the aortic sinus cusp could eliminate it. LGE-MRI was able to reveal the exact location of the single RF lesion.

20.
Indian Pacing Electrophysiol J ; 21(5): 308-312, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34089840

RESUMO

A septuagenarian female with cardiac sarcoidosis suffered from drug refractory ventricular tachycardia (VT) requiring multiple implantable cardioverter-defibrillator shocks. The QRS complex during the VT was very similar to that during sinus rhythm although the QRS width during the VT (142 ms) was relatively wider than that during sinus rhythm (107 ms). The VT exit was located on the ventricular septum close to the His-bundle recording region. However, the critical pathway of this VT was detected on the anterior free wall of the left ventricle (LV), and a radiofrequency application at that site could terminate the VT. No Purkinje potentials were recorded there during the VT or sinus rhythm. According to the electrophysiological study, 3-D mapping, and the response to the ablation, the critical circuit of the VT was surrounded by a protected area of scar associated with cardiac sarcoidosis. As a result, the VT circuit was connected to the basal septal area close to the His-Purkinje system as an outer loop of the VT circuit. This unique trajectory of the VT might have caused a similar QRS morphology to that of sinus rhythm, and the relatively narrow QRS complex despite the critical isthmus was located on the anterior free wall of the LV.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA