Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
BMJ Open Sport Exerc Med ; 10(1): e001778, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38347856

RESUMO

Objectives: To investigate the association between leisure time physical activity (LTPA) and MRI-based diastolic function and the mediating role of metabolic health. Methods: This cross-sectional analysis comprised 901 participants (46% women, mean age (SD): 56 (6) years (The Netherlands, 2008-2012)). LTPA was assessed via questionnaire, quantified in metabolic equivalent of tasks (METs)-minutes per week and participants underwent abdominal and cardiovascular MRI. Confirmatory factor analysis was used to construct the metabolic load factor. Piecewise structural equation model with adjustments for confounders was used to determine associations between LTPA and diastolic function and the mediating effect of metabolic load. Results: Significant differences in mitral early/late peak filling rate (E/A) ratio per SD of LTPA (men=1999, women=1870 MET-min/week) of 0.18, (95% CI= 0.03 to 0.33, p=0.021) were observed in men, but not in women: -0.01 (-0.01 to 0.34, p=0.058). Difference in deceleration time of mitral early filling (E-DT) was 0.13 (0.01 to 0.24, p=0.030) in men and 0.17 (0.05 to 0.28, p=0.005) in women. Metabolic load, including MRI-based visceral and subcutaneous adipose tissue, fasting glucose, high-density lipoprotein cholesterol and triglycerides, mediated these associations as follows: E/A-ratio of 0.030 (0.000 to 0.067, 19% mediated, p=0.047) in men but not in women: 0.058 (0.027 to 0.089, p<0.001) and E-DT not in men 0.004 (-0.012 to 0.021, p=0.602) but did in women 0.044 (0.013 to 0.057, 27% mediated, p=0.006). Conclusions: A larger amount of LTPA was associated with improved diastolic function where confirmatory factor analysis-based metabolic load partly mediated this effect. Future studies should assess whether improving indicators of metabolic load alongside LTPA will benefit healthy diastolic function even more.

2.
Front Cardiovasc Med ; 10: 1285206, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38089763

RESUMO

Introduction: Current practice to obtain left ventricular (LV) native and post-contrast T1 and T2 comprises single-slice readouts with multiple breath-holds (BHs). We propose a multi-slice parallel-imaging approach with a 72-channel receive-array to reduce BHs and demonstrate this in healthy subjects and hypertrophic cardiomyopathy (HCM) patients. Methods: A T1/T2 phantom was scanned at 3 T using a 16-channel and a novel 72-channel coil to assess the impact of different coils and acceleration factors on relaxation times. 16-18 healthy participants (8 female, age 28.4 ± 5.1 years) and 3 HCM patients (3 male, age 55.3 ± 4.2 years) underwent cardiac-MRI with the 72-channel coil, using a Modified Look-Locker scan with a shared inversion pulse across 3 slices and a Gradient-Spin-Echo scan. Acceleration was done by sensitivity encoding (SENSE) with accelerations 2, 4, and 6. LV T1 and T2 values were analyzed globally, per slice, and in 16 segments, with SENSE = 2 as the reference. Results: The phantom scans revealed no bias between coils and acceleration factors for T1 or T2, except for T2 with SENSE = 2, which resulted in a bias of 8.0 ± 6.7 ms (p < 0.001) between coils. SENSE = 4 and 6 enabled T1 mapping of three slices in a single BH, and T2 mapping of three slices within two BHs. In healthy subjects, T1 and T2 values varied. We found an average overestimation of T1 in 3 slices of 25 ± 87 ms for SENSE = 4 and 30 ± 103 ms using SENSE = 6, as compared to SENSE = 2. Acceleration resulted in decreased signal-to-noise; however, visually insignificant and without increased incidence of SENSE-artifacts. T2 was overestimated by 2.1 ± 5.0 ms for SENSE = 4 and 6.4 ± 9.7 ms using SENSE = 6, as compared to SENSE = 2. Native and post-contrast T1 measurements with SENSE = 4 and ECV quantification in HCM patients was successful. Conclusion: The 72-channel receiver-array coil with SENSE = 4 and 6, enabled LV-tissue characterization in three slices. Pre- and post-contrast T1 maps were obtained in a single BH, while T2 required two BHs.

4.
Eur Radiol Exp ; 6(1): 54, 2022 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-36316525

RESUMO

BACKGROUND: A new 72-channel receive array coil and sensitivity encoding, compressed (C-SENSE) and noncompressed (SENSE), were investigated to decrease the number of breath-holds (BHs) for cardiac magnetic resonance (CMR). METHODS: Three-T CMRs were performed using the 72-channel coil with SENSE-2/4/6 and C-SENSE-2/4/6 accelerated short-axis cine two-dimensional balanced steady-state free precession sequences. A 16-channel coil with SENSE-2 served as reference. Ten healthy subjects were included. BH-time was kept under 15 s. Data were compared in terms of image quality, biventricular function, number of BHs, and scan times. RESULTS: BHs decreased from 7 with C-SENSE-2 (scan time 70 s, 2 slices/BH) to 3 with C-SENSE-4 (scan time 42 s, 4-5 slices/BH) and 2 with C-SENSE-6 (scan time 28 s, 7 slices/BH). Compared to reference, image sharpness was similar for SENSE-2/4/6, slightly inferior for C-SENSE-2/4/6. Blood-to-myocardium contrast was unaffected. C-SENSE-4/6 was given lower qualitative median scores, but images were considered diagnostically adequate to excellent, with C-SENSE-6 suboptimal. Biventricular end-diastolic (EDV), end-systolic (ESV) and stroke volumes, ejection fractions (EF), cardiac outputs, and left ventricle (LV)-mass were similar for SENSE-2/4/6 with no systematic bias and clinically appropriate limits of agreements. C-SENSE slightly underestimated LV-EDV (-6.38 ± 6.0 mL, p < 0.047), LV-ESV (-7.94 ± 6.0 mL, p < 0.030) and overestimated LV-EF (3.16 ± 3.10%; p < 0.047) with C-SENSE-4. Bland-Altman analyses revealed minor systematic biases in these variables with C-SENSE-2/4/6 and for LV-mass with C-SENSE-6. CONCLUSIONS: Using the 72-channel coil, short-axis CMR for quantifying biventricular function was feasible in two BHs where SENSE slightly outperformed C-SENSE.


Assuntos
Suspensão da Respiração , Imagem Cinética por Ressonância Magnética , Humanos , Imagem Cinética por Ressonância Magnética/métodos , Ventrículos do Coração , Reprodutibilidade dos Testes , Função Ventricular Esquerda
5.
J Diabetes Complications ; 36(6): 108202, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35491309

RESUMO

AIMS: To quantify metabolic impairment via a one-factor approach with confirmatory factor analysis (CFA) including MRI-derived visceral and subcutaneous adipose tissues and to associate it with diastolic dysfunction. METHODS: In this cross-sectional analysis, 916 participants (53% female, mean age (SD): 56 (6)) underwent abdominal and cardiovascular MRI. With CFA a metabolic-load factor of metabolic-syndrome variables and visceral and subcutaneous adipose tissues was constructed. A piecewise structural equation model approach with adjustment for confounding factors was used to determine associations with left-ventricular diastolic function, cardiac morphology and hemodynamics. RESULTS: Model fitting excluding blood pressure and waist circumference but including visceral and subcutaneous adipose tissues, fasting glucose, HDL-c and triglycerides was used to construct the metabolic-load factor. Evaluating measurement invariance demonstrated sex-specificity. Change in mitral early/late peak filling rate ratio was -0.12 for both males [-0.20; -0.05, p > 0.05] and females [-0.17; -0.07, p > 0.001] per SD of metabolic-load factor. Change in deceleration time of mitral early filling was -11.83 ms in females [-17.38; -6.27] per SD of metabolic-load factor. CONCLUSION: A single latent metabolic-load factor via CFA including MRI-derived adipose tissues increased sensitivity for metabolic impairment obsoleting waist circumference and is associated with a decreased left-ventricular diastolic function, more apparent in females than in males.


Assuntos
Síndrome Metabólica , Obesidade , Tecido Adiposo/diagnóstico por imagem , Tecido Adiposo/metabolismo , Estudos Transversais , Análise Fatorial , Feminino , Humanos , Imageamento por Ressonância Magnética , Masculino , Síndrome Metabólica/complicações , Síndrome Metabólica/diagnóstico por imagem , Obesidade/complicações
6.
Pediatr Cardiol ; 43(4): 796-806, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-34988599

RESUMO

Tricuspid valve agenesis/atresia (TVA) is a congenital cardiac malformation where the tricuspid valve is not formed. It is hypothesized that TVA results from a failure of the normal rightward expansion of the atrioventricular canal (AVC). We tested predictions of this hypothesis by morphometric analyses of the AVC in fetal hearts. We used high-resolution MRI and ultrasonography on a post-mortem fetal heart with TVA and with tricuspid valve stenosis (TVS) to validate the position of measurement landmarks that were to be applied to clinical echocardiograms. This revealed a much deeper right atrioventricular sulcus in TVA than in TVS. Subsequently, serial echocardiograms of in utero fetuses between 12 and 38 weeks of gestation were included (n = 23 TVA, n = 16 TVS, and n = 74 controls) to establish changes in AVC width and ventricular dimensions over time. Ventricular length and width and estimated fetal weight all increased significantly with age, irrespective of diagnosis. Heart rate did not differ between groups. However, in the second trimester, in TVA, the ratio of AVC to ventricular width was significantly lower compared to TVS and controls. This finding supports the hypothesis that TVA is due to a failed rightward expansion of the AVC. Notably, we found in the third trimester that the AVC to ventricular width normalized in TVA fetuses as their mitral valve area was greater than in controls. Hence, TVA associates with a quantifiable under-development of the AVC. This under-development is obscured in the third trimester, likely because of adaptational growth that allows for increased stroke volume of the left ventricle.


Assuntos
Atresia Pulmonar , Atresia Tricúspide , Ecocardiografia , Feminino , Coração Fetal/diagnóstico por imagem , Humanos , Gravidez , Atresia Pulmonar/complicações , Atresia Tricúspide/complicações , Valva Tricúspide/diagnóstico por imagem , Ultrassonografia Pré-Natal
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA