Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Head Face Med ; 17(1): 33, 2021 Aug 14.
Artigo em Inglês | MEDLINE | ID: mdl-34389020

RESUMO

BACKROUND: This study was designed to analyse the value of preoperative Cone Beam CTs (CBCT) prior to the surgical removal of complex lower third molars. Furthermore, the aim was to assess injuries to the inferior alveolar nerve (IAN) bundle and postoperative neurological disorders depending on the position of the lower third molar and the inferior alveolar nerve bundle. METHODS: In this retrospective examination preoperative Cone Beam CTs and Orthopantomographs (OPT) of 324 patients were analysed concerning the location of the lower third molars in relation to the mandible and the inferior alveolar nerve bundle. Surgery protocols of all patients who underwent the surgical removal of at least one complex lower third molar were analysed concerning patient data, length of surgery, intraoperative haemorrhage, intraoperative exposure of the inferior alveolar nerve bundle, postoperative swelling and postoperative neurological disorders. The data was then compared to data from international studies. RESULTS: In all 324 patients a permanent neurological damage was not found. Temporary neurological damage was recorded in 13 cases (2.6%). A caudal nerve position with no measurable distance to the root of the lower third molar was associated with the highest risk of a temporal neurological damage. A vestibular touching nerve route also correlated with postoperative sensitivity impairment. If a mesioangulation (Winter) or a Pell and Gregory Type IIIC appears in the OPT, risk of neurological damage is at its highest. CONCLUSIONS: Three-dimensional radiographic imaging, in our patient group, does not significantly affect the risk for complications during the surgical removal of complex lower third molars. Therefore, it should only be utilized for risk assessment, especially in cases of symptom-free lower third molars. A preoperative orthopantomogram still can be accepted as standard for radiographic imaging. An intraoperative exposure of the IAN bundle does not necessarily predict simultaneous neurological damage. Exposure of the IAN bundle is no indication for a discontinuation of the surgery.


Assuntos
Dente Impactado , Traumatismos do Nervo Trigêmeo , Tomografia Computadorizada de Feixe Cônico , Humanos , Mandíbula/diagnóstico por imagem , Mandíbula/cirurgia , Nervo Mandibular/diagnóstico por imagem , Dente Serotino/diagnóstico por imagem , Dente Serotino/cirurgia , Radiografia Panorâmica , Estudos Retrospectivos , Extração Dentária/efeitos adversos , Dente Impactado/diagnóstico por imagem , Dente Impactado/cirurgia , Traumatismos do Nervo Trigêmeo/prevenção & controle
2.
J Craniomaxillofac Surg ; 43(3): 408-13, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25648069

RESUMO

INTRODUCTION: The objective of this study was to determine whether postoperative control of the neurostimulator placement within the pterygopalatine fossa (PPF) by means of 3-dimensional (3D) cone beam computed tomography (CBCT) was of therapeutic relevance compared to intraoperative CBCT imaging alone. MATERIAL AND METHODS: Immediately after implantation of the sphenopalatine ganglion (SPG) neurostimulator, intraoperative CBCT datasets were generated in order to visualize the position of the probe within the PPF. Postoperatively, all patients received a CBCT for comparison with intraoperatively acquired radiographs. RESULTS: Twenty-four patients with cluster headache (CH) received an SPG neurostimulator. In 4 patients, postoperative CBCT images detected misplacement not found in intraoperative CBCT. In 3 cases, electrode tips were misplaced into the maxillary sinus and in 1 case into the apex of the PPF superior to the suspected location of the SPG. Immediate revision with successful repositioning within 3 days was done in 2 patients and a deferred reimplantation in 1 patient within 6 months. One patient declined revision. CONCLUSION: We were able to demonstrate the clinical value of postoperative dental CBCT imaging with a wide region of interest (ROI) due to a superior image quality compared with that achieved with intraoperative medical CBCT. Although intraoperative 3D CBCT imaging of electrode placement is helpful in the acute surgical setting, resolution is, at present, too low to safely exclude misplacement, especially in the maxillary sinus. High-resolution postoperative dental CBCT allows rapid detection and revision of electrode misplacement, thereby avoiding readmission and recurrent tissue trauma.


Assuntos
Cefaleia Histamínica/terapia , Tomografia Computadorizada de Feixe Cônico/métodos , Terapia por Estimulação Elétrica/instrumentação , Eletrodos Implantados , Imageamento Tridimensional/métodos , Cuidados Intraoperatórios , Cuidados Pós-Operatórios , Fossa Pterigopalatina/inervação , Adulto , Idoso , Eletrodos Implantados/efeitos adversos , Desenho de Equipamento , Feminino , Migração de Corpo Estranho/diagnóstico por imagem , Gânglios Parassimpáticos/fisiologia , Humanos , Processamento de Imagem Assistida por Computador/métodos , Masculino , Seio Maxilar/diagnóstico por imagem , Pessoa de Meia-Idade , Fossa Pterigopalatina/diagnóstico por imagem , Reoperação , Estudos Retrospectivos , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA