Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 39
Filtrar
1.
Oncogene ; 41(40): 4560-4572, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-36068335

RESUMO

Overexpression of MYC is a genuine cancer driver in lymphomas and related to poor prognosis. However, therapeutic targeting of the transcription factor MYC remains challenging. Here, we show that inhibition of the histone deacetylase 6 (HDAC6) using the HDAC6 inhibitor Marbostat-100 (M-100) reduces oncogenic MYC levels and prevents lymphomagenesis in a mouse model of MYC-induced aggressive B-cell lymphoma. M-100 specifically alters protein-protein interactions by switching the acetylation state of HDAC6 substrates, such as tubulin. Tubulin facilitates nuclear import of MYC, and MYC-dependent B-cell lymphoma cells rely on continuous import of MYC due to its high turn-over. Acetylation of tubulin impairs this mechanism and enables proteasomal degradation of MYC. M-100 targets almost exclusively B-cell lymphoma cells with high levels of MYC whereas non-tumor cells are not affected. M-100 induces massive apoptosis in human and murine MYC-overexpressing B-cell lymphoma cells. We identified the heat-shock protein DNAJA3 as an interactor of tubulin in an acetylation-dependent manner and overexpression of DNAJA3 resulted in a pronounced degradation of MYC. We propose a mechanism by which DNAJA3 associates with hyperacetylated tubulin in the cytoplasm to control MYC turnover. Taken together, our data demonstrate a beneficial role of HDAC6 inhibition in MYC-dependent B-cell lymphoma.


Assuntos
Linfoma de Células B , Tubulina (Proteína) , Acetilação , Animais , Proteínas de Choque Térmico HSP40/metabolismo , Proteínas de Choque Térmico/metabolismo , Desacetilase 6 de Histona/metabolismo , Inibidores de Histona Desacetilases/farmacologia , Histona Desacetilases/genética , Histona Desacetilases/metabolismo , Humanos , Linfoma de Células B/tratamento farmacológico , Linfoma de Células B/genética , Camundongos , Fatores de Transcrição/metabolismo , Tubulina (Proteína)/metabolismo
2.
Microcirculation ; 29(3): e12754, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-35218286

RESUMO

OBJECTIVE: To find out whether application of cold atmospheric plasma (CAP) affects microcirculation in chronic wounds. METHODS: We treated 20 patients with chronic wounds on the lower extremity with CAP. Blood flow parameters of wounds were assessed with combined Laser-Doppler-Flowmetry and spectrophotometry in tissue depth of 2 and 6-8 mm. Parameters were assessed under standardized conditions before and over the course of 30 min after application of CAP. RESULTS: Deep capillary blood flow increased significantly by up to 24.33% (percentage change) after treatment with CAP and remained significantly elevated until the end of measuring period at 30 min. Superficial oxygen tissue saturation was significantly elevated by 14.05% for the first 5 min after treatment. Postcapillary venous filling pressure was significantly elevated by 10.23% 19 min after CAP and stayed significantly elevated starting from minute 24 until the end of measuring. CONCLUSION: Cold atmospheric plasma increases microcirculation parameters in chronic wounds significantly. As CAP is known for its benefits in wound healing, the effects observed may explain the improved healing of chronic wounds after its use. Whether CAP-application can increase blood flow in chronic wounds for longer periods of time or boosts blood flow when applied more than once should be subject to further research.


Assuntos
Gases em Plasma , Capilares , Humanos , Fluxometria por Laser-Doppler , Microcirculação/fisiologia , Gases em Plasma/farmacologia , Gases em Plasma/uso terapêutico , Cicatrização
3.
J Vasc Interv Radiol ; 33(4): 384-391.e7, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-34958860

RESUMO

PURPOSE: To evaluate the feasibility and accuracy of a radiation-free implantation of a thoracic aortic stent graft employing fiberoptic and electromagnetic tracking in an anthropomorphic phantom. MATERIALS AND METHODS: An anthropomorphic phantom was manufactured based on computed tomography (CT) angiography data from a patient. An aortic stent graft application system was equipped with a fiber Bragg gratings and 3 electromagnetic sensors. The stent graft was navigated in the phantom by 3 interventionalists using the tracking data generated by both technologies. One implantation procedure was performed. The technical success of the procedure was evaluated using digital subtraction angiography and CT angiography (before and after the intervention). Tracking accuracy was determined at various anatomical landmarks based on separately acquired fluoroscopic images. The mean/maximum errors were measured for the stent graft application system and the tip/end of the stent graft. RESULTS: The procedure resulted in technical success with a mean error below 3 mm for the entire application system and <2 mm for the position of the tip of the stent graft. Navigation/implantation and handling of the device were rated sufficiently accurate and on par with comparable, routinely used stent graft application systems. CONCLUSIONS: The study demonstrates successful stent graft implantation during a thoracic endovascular aortic repair procedure employing advanced guidance techniques and avoiding fluoroscopic imaging. This is an essential step in facilitating the implantation of stent grafts and reducing the health risks associated with ionizing radiation during endovascular procedures.


Assuntos
Aneurisma da Aorta Abdominal , Aneurisma da Aorta Torácica , Implante de Prótese Vascular , Procedimentos Endovasculares , Aneurisma da Aorta Abdominal/cirurgia , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/cirurgia , Prótese Vascular , Fenômenos Eletromagnéticos , Humanos , Imageamento Tridimensional , Stents , Resultado do Tratamento
4.
Microvasc Res ; 138: 104220, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34216601

RESUMO

BACKGROUND: Chronic wounds, such as venous leg ulcers, diabetic foot ulcers, and pressure ulcers, impose a significant burden on patients and health care systems worldwide. Cold atmospheric plasma (CAP) accelerates wound healing and decreases bacterial load in chronic wounds in both in vitro and in vivo experiments. For the first time, we examined the effects of a repetitive application of CAP on the microcirculation in chronic wounds. HYPOTHESIS: The repetitive application of cold atmospheric plasma application further improves microcirculation in chronic wounds. METHODS: Twenty patients with chronic wounds were treated repetitively with CAP. The repetitive application consisted of three CAP sessions, each lasting 90 s and separated by a 10-minute microcirculation measuring period. Microcirculation parameters were assessed with combined Laser-Doppler-Flowmetry and spectrophotometry in a tissue depth of 2 mm. RESULTS: Tissue oxygen saturation was significantly increased after the first CAP application. The effect amplitude and duration were further increased after the second and third CAP application with a maximum increase by 16,7% (percent change; p = 0,004 vs. baseline) after the third application. There was no significant increase in capillary blood flow until the third CAP application. After the third CAP application, an increase by 22,6% (p = 0,014) was observed. Postcapillary filling pressure was not significantly increased over the measuring period. The repetitive application of CAP further enhances the microcirculation in chronic wounds compared to a single application. CONCLUSION: The repetitive application of CAP boosts and prolongs tissue oxygen saturation and capillary blood flow in chronic wounds compared to a single application. This insight could provide an impetus for new treatment protocols.


Assuntos
Capilares/fisiopatologia , Úlcera da Perna/terapia , Microcirculação , Gases em Plasma/uso terapêutico , Pele/irrigação sanguínea , Cicatrização , Idoso , Doença Crônica , Feminino , Humanos , Fluxometria por Laser-Doppler , Úlcera da Perna/patologia , Úlcera da Perna/fisiopatologia , Masculino , Pessoa de Meia-Idade , Saturação de Oxigênio , Gases em Plasma/efeitos adversos , Estudos Prospectivos , Recuperação de Função Fisiológica , Espectrofotometria , Fatores de Tempo , Resultado do Tratamento
5.
Biomed Tech (Berl) ; 66(3): 285-292, 2021 Jun 25.
Artigo em Inglês | MEDLINE | ID: mdl-34062634

RESUMO

Cancer will be the leading cause of death in a few decades. In line with minimal invasive lung cancer surgery, surgeons loose most of their tactile tissue information and need an additional tool of intraoperative tissue navigation during surgery. Confocal laser microscopy is a well-established method of tissue investigation. In this ex-vivo pilot study, we evaluated an endoscopic confocal laser microscope (eCLM) that does not need any fluorescent dye as a diagnostic tool in non-malignant and malignant pulmonary tissue and distal stapler resection margins, respectively. In seven cases, an eCLM was used for examining pulmonary tissue ex-vivo. Images of non-malignant and non-small cell lung cancer tissue and distal stapler resection margins were characterized in terms of specific signal-patterns. No fluorescent dye was used. Correlations to findings in conventional histology were systematically recorded and described. Healthy lung tissue showed hyperreflectoric alveolar walls with dark alveolar spaces. Hyperreflective nets indicated the tumor stroma; whereas the hyperreflective areas indicated the tumor cell clusters. Compared to adenocarcinoma tissue, tissue from squamous cell carcinoma showed more distinctive hyperreflective stroma nets. eCLM characteristics seen in non-malignant and malignant tissue were also visible in distal stapler resection margins and so therefore it was feasible to distinguish between healthy lung tissue and lung cancer. This pilot study shows that the assessment of pulmonary tissue with this eCLM for minimally invasive surgical approach without any fluorescent dye is feasible. It enables to differentiate between benign and malignant tissue in pulmonary specimen by easy to evaluate and reproducible parameters.


Assuntos
Adenocarcinoma/cirurgia , Carcinoma Pulmonar de Células não Pequenas/patologia , Corantes Fluorescentes/química , Neoplasias Pulmonares/fisiopatologia , Adenocarcinoma/patologia , Endoscopia/métodos , Humanos , Lasers , Microscopia Confocal/métodos , Procedimentos Cirúrgicos Minimamente Invasivos , Projetos Piloto , Cirurgia Torácica
6.
J Vasc Surg Venous Lymphat Disord ; 9(2): 435-443, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-32502730

RESUMO

BACKGROUND: Sclerotherapy is considered to be the method of choice for the treatment of telangiectatic varicose veins (C1 veins). Whereas the use of compression stockings after sclerotherapy is recommended, little is known about the impact of compression on the outcome of sclerotherapy. The aim of this study was to assess the influence of compression on the outcome of injection sclerotherapy of C1 varicose veins. METHODS: There were 100 legs of 50 consecutive patients with chronic venous insufficiency (C1) included. After randomization per patient, both legs were treated with sclerotherapy in a predefined area of the thigh (measuring 100 cm2), followed by eccentric compression for 24 hours. Group A received no further compression, whereas group B was additionally equipped with compression stockings of 18 to 20 mm Hg above the ankle and continued wearing these for 1 week. Photodocumentation was performed before, 1 week after, and 4 weeks after sclerotherapy, and the clinical outcome was assessed at these postprocedure follow-up dates. The photographs were reviewed by an internal unblinded rater and an independent blinded external rater. RESULTS: There was no discernible difference between the groups in terms of clinical outcome or side effects after 4 weeks. Whereas inter-rater reliability was high, there was no correlation between the raters and patients in terms of outcome. In 55% of the treated legs, the patients deemed the result of the treatment to be good; in 27% of the treated legs, fair; and in 18%, poor. Postprocedure hyperpigmentation occurred in 13% of patients and was comparable in both groups. Compression therapy was found to be comfortable by the majority (58%) of patients. CONCLUSIONS: One week of postinterventional compression therapy had no clinical benefit compared with no compression.


Assuntos
Polidocanol/administração & dosagem , Soluções Esclerosantes/administração & dosagem , Escleroterapia , Meias de Compressão , Telangiectasia/terapia , Varizes/terapia , Insuficiência Venosa/terapia , Doença Crônica , Terapia Combinada , Alemanha , Humanos , Injeções Intravenosas , Polidocanol/efeitos adversos , Estudos Prospectivos , Soluções Esclerosantes/efeitos adversos , Escleroterapia/efeitos adversos , Meias de Compressão/efeitos adversos , Telangiectasia/diagnóstico por imagem , Telangiectasia/fisiopatologia , Fatores de Tempo , Resultado do Tratamento , Varizes/diagnóstico por imagem , Varizes/fisiopatologia , Insuficiência Venosa/diagnóstico por imagem , Insuficiência Venosa/fisiopatologia
7.
Ann Anat ; 234: 151629, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33137459

RESUMO

INTRODUCTION: 3D printing has a wide range of applications in medicine. In surgery, this technique can be used for preoperative planning of complex procedures, production of patient specific implants, as well as training. However, accuracy evaluations of 3D vascular models are rare. OBJECTIVES: Aim of this study was to investigate the accuracy of patient-specific 3D-printed aortic anatomies. METHODS: Patients suffering from aorto-iliac aneurysms and with indication for treatment were selected on the basis of different anatomy and localization of the aneurysm in the period from January 1st 2014 to May 27th 2016. Six patients with aorto-iliac aneurysms were selected out of the database for 3D-printing. Subsequently, computed tomography (CT) images of the printed 3D-models were compared with the original CT data sets. RESULTS: The mean deviation of the six 3D-vascular models ranged between -0.73 mm and 0.14 mm compared to the original CT-data. The relative deviation of the measured values showed no significant difference between the 3D-vascular and the original patient CT-data. CONCLUSION: Our results showed that 3D printing has the potential to produce patient-specific 3D vascular models with reliable accuracy. This enables the use of such models for the development of new endovascular procedures and devices.


Assuntos
Procedimentos Endovasculares , Impressão Tridimensional , Aorta , Humanos , Modelos Anatômicos , Tomografia Computadorizada por Raios X
8.
Int J Comput Assist Radiol Surg ; 15(6): 1033-1042, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32383105

RESUMO

PURPOSE: During endovascular aneurysm repair (EVAR) procedures, medical instruments are guided with two-dimensional (2D) fluoroscopy and conventional digital subtraction angiography. However, this requires X-ray exposure and contrast agent is used, and the depth information is missing. To overcome these drawbacks, a three-dimensional (3D) guidance approach based on tracking systems is introduced and evaluated. METHODS: A multicore fiber with fiber Bragg gratings for shape sensing and three electromagnetic (EM) sensors for locating the shape were integrated into a stentgraft system. A model for obtaining the located shape of the first 38 cm of the stentgraft system with two EM sensors is introduced and compared with a method based on three EM sensors. Both methods were evaluated with a vessel phantom containing a 3D-printed vessel made of silicone and agar-agar simulating the surrounding tissue. RESULTS: The evaluation of the guidance methods resulted in average errors from 1.35 to 2.43 mm and maximum errors from 3.04 to 6.30 mm using three EM sensors, and average errors from 1.57 to 2.64 mm and maximum errors from 2.79 to 6.27 mm using two EM sensors. Moreover, the videos made from the continuous measurements showed that a real-time guidance is possible with both approaches. CONCLUSION: The results showed that an accurate real-time guidance with two and three EM sensors is possible and that two EM sensors are already sufficient. Thus, the introduced 3D guidance method is promising to use it as navigation tool in EVAR procedures. Future work will focus on developing a method with less EM sensors and a detailed latency evaluation of the guidance method.


Assuntos
Aneurisma Aórtico/cirurgia , Implante de Prótese Vascular/instrumentação , Imageamento Tridimensional/métodos , Angiografia Digital , Procedimentos Endovasculares/métodos , Fluoroscopia , Humanos , Imagens de Fantasmas
9.
Ann Anat ; 231: 151519, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32305378

RESUMO

PURPOSE: Endovascular interventions have become standard procedures for the therapy of abdominal aortic aneurysms. Therefore, endovascular surgeons need special skills which have to be learned and trained. Additionally, authentic simulators are needed for further development of new endovascular devices and procedures. The aim of this project was to develop an authentic and modular endovascular simulation environment with patient-specific vascular anatomy for training and research purposes. MATERIAL AND METHODS: We first designed a prototype with exchangeable 3D-printed patient-specific vascular anatomy. Then, the feasibility of the prototype was validated by a simulation of an EVAR procedure in a clinical setting. RESULTS: We developed an authentic endovascular simulator with an exchangeable patient-specific vascular anatomy and performed an EVAR procedure under realistic conditions. The evaluation of the accuracy of the vascular models showed little deviation when compared with the original CT data. CONCLUSION: Endovascular simulators based on patient-specific 3D-printed vascular models can realistically mimic endovascular procedures and have the potential to be used for further development of new devices and grafts as well as for training purposes. Furthermore, in our opinion they can reduce the use of animals during developmental processes.


Assuntos
Vasos Sanguíneos/anatomia & histologia , Procedimentos Endovasculares/educação , Procedimentos Endovasculares/métodos , Estudos de Viabilidade , Humanos , Impressão Tridimensional , Treinamento por Simulação/métodos
10.
Zentralbl Chir ; 144(5): 445-448, 2019 Oct.
Artigo em Alemão | MEDLINE | ID: mdl-31269515

RESUMO

OBJECTIVE: Visceral artery aneurysms are a rare but dangerous vascular pathology. The branches of the coeliac trunc are most frequently affected, especially the splenic artery. A visceral aneurysm is usually diagnosed only when a bleeding complication occurs due to rupture. It is therefore recommended to treat this pathology at an early stage after diagnosis. Endovascular elimination is the preferred procedure. However, if endovascular elimination is not suitable, the visceral aneurysm can be successfully treated by minimally invasive surgery. INDICATIONS: Splenic artery aneurysms are located at the splenic hilum, and are therefore considered to be at high risk of splenic ischemia and secondary complications following endovascular coiling. PROCEDURE: Laparoscopic treatment of splenic artery aneurysm. CONCLUSION: In the case of complex vascular pathologies unsuitable for an endovascular approach, laparoscopic treatment of splenic artery aneurysm is a safe and effective minimally invasive option and alternative.


Assuntos
Aneurisma , Embolização Terapêutica , Laparoscopia , Aneurisma/cirurgia , Artéria Celíaca , Humanos , Artéria Esplênica , Resultado do Tratamento
11.
Dtsch Med Wochenschr ; 144(9): 606-623, 2019 05.
Artigo em Alemão | MEDLINE | ID: mdl-31026870

RESUMO

Varicosis of the lower limb is a common disease that can lead to edema, trophic disturbances and skin ulcerations. In addition to the classic surgical procedure of crossectomy with stripping of the saphenous vein, a growing number of minimally invasive endoluminal treatment methods has been established over the past 15 years, offering a colorful array of procedures to the modern phlebologist. It is important to choose the optimal treatment option for each individual patient.


Assuntos
Procedimentos Endovasculares , Escleroterapia , Varizes/terapia , Humanos
13.
Surg Endosc ; 33(6): 1811-1817, 2019 06.
Artigo em Inglês | MEDLINE | ID: mdl-30242465

RESUMO

BACKGROUND: Histological analysis of surgical specimen is the gold standard for cancer classification. In particular, frozen histological diagnosis of vague peritoneal spots or uncertain excision of tumors plays a crucial role in the decision to proceed with or abandon an operation. Confocal laser microscopy (CLM) enables in-vivo and real-time high-resolution tissue analysis. This method has already been used during endoscopic assessments analyzing transformation of esophageal or colon mucosa. We examined whether a CLM device enables to distinguish between non-malignant and malignant tissue in vivo and real time and enables to assign peritoneal carcinomatosis spots to their primary tumor. In addition, we investigated whether the newly developed CLM camera device causes any tissue damage. METHODS: CC531 colon carcinoma cells were implanted on the serosa side of the colon and intraperitoneally in Wag/Rija rats via laparotomy. After 7 days of tumor growth, confocal laser microscopy in vivo was performed by re-laparotomy. Images of non-malignant and malignant tissue were characterized in terms of specific signal pattern. No fluorescent dye was used. Correlations to findings in conventional histology were systematically recorded and described. Potential tissue damage was examined by conventional histology. RESULTS: All animals survived the operative procedure and could be evaluated 7 days following surgery. No unexpected death occurred after surgery. Non-malignant colon is defined by small cycles of the microvilli of the colon. There is repetitive deregulated structure in colon carcinoma. Peritoneal carcinomatosis showed the same structural pattern as in primary colon carcinoma. In all examined cases, it was possible to differentiate between peritoneal carcinomatosis spots and non-malignant peritoneum. The CLM device did not cause any tissue damage. CONCLUSIONS: The CLM camera device reported here is feasible to identify peritoneal carcinomatosis spots, assign these spots to the primary tumor, as well as distinguish between non-malignant and malignant tissue in without using any fluorescent dye.


Assuntos
Adenocarcinoma/cirurgia , Colo/diagnóstico por imagem , Neoplasias do Colo/cirurgia , Cuidados Intraoperatórios/métodos , Microscopia Confocal/métodos , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Peritônio/diagnóstico por imagem , Adenocarcinoma/diagnóstico por imagem , Adenocarcinoma/patologia , Adenocarcinoma/secundário , Animais , Linhagem Celular Tumoral , Colo/patologia , Colo/cirurgia , Neoplasias do Colo/diagnóstico por imagem , Neoplasias do Colo/patologia , Sistemas Computacionais , Humanos , Laparotomia , Masculino , Transplante de Neoplasias , Neoplasias Peritoneais/diagnóstico por imagem , Neoplasias Peritoneais/secundário , Peritônio/patologia , Peritônio/cirurgia , Ratos
14.
Surg Endosc ; 32(12): 4966-4972, 2018 12.
Artigo em Inglês | MEDLINE | ID: mdl-29869079

RESUMO

BACKGROUND: Hepatocellular carcinoma is a highly prevalent and lethal primary neoplasia of the liver and metastases of other malignancies affect most frequently the liver. Minimally invasive surgical approach for liver resections is advancing. Dissection of liver parenchyma by laparoscopic technique remains challenging and new technologies are in need. Therefore, we asked whether it is feasible to dissect liver tissue comparably in terms of speed and hemostasis with a non-contact 1.9-µm cw-laser device and whether there are differences in the postoperative healing process compared to a gold standard device (ultrasound aspirator) in an experimental model. METHODS: Laparoscopic laser and ultrasound aspirator standardized partial liver resections were performed in seven pigs. Resection time, hemostasis time, and blood loss were evaluated. After at least 10 days, representative specimen of the resection areas was collected via re-laparoscopy and biopsy and side effects like hematoma, abscess, or bilioma were noted. Histologically, coagulation necrosis margin, granulation tissue zone, tissue fibrosis, and giant cell count were analyzed. RESULTS: Laparoscopic laser liver resection was three times faster compared to the laparoscopic ultrasound aspirator. Blood loss was equal in both groups. No side effects like hematoma or bilioma occurred. Histologically, specimen showed the same expansion of coagulation necrosis zone and granulation tissue. Fibrotic scar could be determined in three cases in both groups, respectively. However, giant cell count was significant higher in the laser resection group. CONCLUSIONS: The 1.9-µm cw-laser device enables a safe and fast liver resection in an experimental pig model compared to a gold standard (ultrasound aspirator) laparoscopic liver resection method. Wound healing is not interfered by laser liver resection.


Assuntos
Carcinoma Hepatocelular/cirurgia , Hepatectomia/métodos , Laparoscopia/métodos , Terapia a Laser/métodos , Neoplasias Hepáticas Experimentais/cirurgia , Animais , Suínos
15.
Innov Surg Sci ; 3(3): 167-177, 2018 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-31579781

RESUMO

INTRODUCTION: Endovascular aortic repair (EVAR) is a minimal-invasive technique that prevents life-threatening rupture in patients with aortic pathologies by implantation of an endoluminal stent graft. During the endovascular procedure, device navigation is currently performed by fluoroscopy in combination with digital subtraction angiography. This study presents the current iterative process of biomedical engineering within the disruptive interdisciplinary project Nav EVAR, which includes advanced navigation, image techniques and augmented reality with the aim of reducing side effects (namely radiation exposure and contrast agent administration) and optimising visualisation during EVAR procedures. This article describes the current prototype developed in this project and the experiments conducted to evaluate it. METHODS: The current approach of the Nav EVAR project is guiding EVAR interventions in real-time with an electromagnetic tracking system after attaching a sensor on the catheter tip and displaying this information on Microsoft HoloLens glasses. This augmented reality technology enables the visualisation of virtual objects superimposed on the real environment. These virtual objects include three-dimensional (3D) objects (namely 3D models of the skin and vascular structures) and two-dimensional (2D) objects [namely orthogonal views of computed tomography (CT) angiograms, 2D images of 3D vascular models, and 2D images of a new virtual angioscopy whose appearance of the vessel wall follows that shown in ex vivo and in vivo angioscopies]. Specific external markers were designed to be used as landmarks in the registration process to map the tracking data and radiological data into a common space. In addition, the use of real-time 3D ultrasound (US) is also under evaluation in the Nav EVAR project for guiding endovascular tools and updating navigation with intraoperative imaging. US volumes are streamed from the US system to HoloLens and visualised at a certain distance from the probe by tracking augmented reality markers. A human model torso that includes a 3D printed patient-specific aortic model was built to provide a realistic test environment for evaluation of technical components in the Nav EVAR project. The solutions presented in this study were tested by using an US training model and the aortic-aneurysm phantom. RESULTS: During the navigation of the catheter tip in the US training model, the 3D models of the phantom surface and vessels were visualised on HoloLens. In addition, a virtual angioscopy was also built from a CT scan of the aortic-aneurysm phantom. The external markers designed for this study were visible in the CT scan and the electromagnetically tracked pointer fitted in each marker hole. US volumes of the US training model were sent from the US system to HoloLens in order to display them, showing a latency of 259±86 ms (mean±standard deviation). CONCLUSION: The Nav EVAR project tackles the problem of radiation exposure and contrast agent administration during EVAR interventions by using a multidisciplinary approach to guide the endovascular tools. Its current state presents several limitations such as the rigid alignment between preoperative data and the simulated patient. Nevertheless, the techniques shown in this study in combination with fibre Bragg gratings and optical coherence tomography are a promising approach to overcome the problems of EVAR interventions.

16.
J Cardiovasc Surg (Torino) ; 59(2): 225-231, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-28548473

RESUMO

BACKGROUND: To evaluate the safety and efficacy of a novel balloon-expandable stent-graft for endovascular treatment of visceral artery aneurysms (VAA). METHODS: Between 9/2014 and 1/2017 seven patients (69±15 years) with true (N.=4) and false (N.=3) VAAs were treated by implantation of balloon-expandable stent-grafts (E-ventus®, Jotec, Hechingen, Germany) using a transfemoral (N.=2) or transbrachial (N.=5) vascular access. The stent-graft was placed without prior passing of the landing zone with a sheath. In 3 of 7 patients (42.9%) additional coil or plug embolization was performed to prevent retrograde VAA perfusion. Endpoints were technical success (defined as delivery and implantation of the stent-graft in the intended position with complete exclusion of the VAA), peri-procedural complications and patency. RESULTS: Mean diameters of true VAAs (splenic artery: N.=2, common hepatic artery: N.=1, celiac trunk: N.=1) were 26±9 and of false (common hepatic artery: N.=2, gastroduodenal artery: N.=1) 29±14 mm. False aneurysms presented as emergencies with active bleeding. Technical success was 100%. One peri-procedural complication was noted: pseudoaneurysm of the accessed brachial artery. After a mean follow-up of 187 days 6/7 stent-grafts (85.7%) were patent. One patient (fVAA) died two days after the emergency procedure owing to multi-organ failure which was assessed to be non-procedure-related. Another patient (fVAA) died 7 months from the procedure owing to cancer. CONCLUSIONS: Endovascular treatment of true and false visceral artery aneurysms by use of the E-ventus® stent-graft is safe and effective. Flexibility of the stent-graft and shaft allows for implantation without passing the lesion with a sheath, enabling treatment of distal as well as complex visceral lesions. Long-term results regarding patency in a larger patient cohort are needed to confirm these findings.


Assuntos
Falso Aneurisma/cirurgia , Aneurisma/cirurgia , Angioplastia com Balão/instrumentação , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Stents , Vísceras/irrigação sanguínea , Idoso , Idoso de 80 Anos ou mais , Aneurisma/diagnóstico por imagem , Aneurisma/mortalidade , Aneurisma/fisiopatologia , Falso Aneurisma/diagnóstico por imagem , Falso Aneurisma/mortalidade , Falso Aneurisma/fisiopatologia , Angioplastia com Balão/efeitos adversos , Angioplastia com Balão/mortalidade , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/mortalidade , Angiografia por Tomografia Computadorizada , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/etiologia , Desenho de Prótese , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Grau de Desobstrução Vascular
17.
Healthc Technol Lett ; 4(5): 184-187, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-29184662

RESUMO

A major challenge during endovascular interventions is visualising the position and orientation of the catheter being inserted. This is typically achieved by intermittent X-ray imaging. Since the radiation exposure to the surgeon is considerable, it is desirable to reduce X-ray exposure to the bare minimum needed. Additionally, transferring two-dimensional (2D) X-ray images to 3D locations is challenging. The authors present the development of a real-time navigation framework, which allows a 3D holographic view of the vascular system without any need of radiation. They extract the patient's surface and vascular tree from pre-operative computed tomography data and register it to the patient using a magnetic tracking system. The system was evaluated on an anthropomorphic full-body phantom by experienced clinicians using a four-point questionnaire. The average score of the system (maximum of 20) was found to be 17.5. The authors' approach shows great potential to improve the workflow for endovascular procedures, by simultaneously reducing X-ray exposure. It will also improve the learning curve and help novices to more quickly master the required skills.

18.
Surg Innov ; 23(4): 341-6, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-26976830

RESUMO

Introduction Histological analysis of surgical specimen is the gold standard for cancer classification. In particular, frozen histological diagnosis of vague peritoneal spots or uncertain excision of tumors plays a crucial role for proceeding with or without change of the operation procedure. Confocal laser microscopy (CLM) enables in vivo and real-time high-resolution tissue analysis. To evaluate a novel technique of CLM without any fluorescent dye, this pilot ex vivo study demonstrates a CLM camera device for minimal invasive surgical approach. Methods In 5 cases, a laparoscopic CLM camera was used for examining colon and rectum specimen. Images of nonmalignant and malignant intestinal mucosa were characterized in terms of specific signal-patterns. No fluorescent dye was used. Correlations to findings in conventional histology were systematically recorded and described. Results Using this CLM camera device, it is possible to analyze colon specimen mucosa. Nonmalignant and malignant intestinal mucosa show specific signal patterns. Nonmalignant mucosa is defined by honeycomb structure. There is deregulated structure in colon and rectum carcinoma mucosa. The inside lumen is irregular. The radial border appears swollen with reduced contrast. Discussion This pilot study shows that the assessment of colon mucosa with a prototype of CLM camera for minimally invasive surgical approach without any fluorescent dye is feasible. It is possible to differentiate between benign and malignant mucosa in colon specimen by easy to evaluate and reproducible parameters. These first steps of this pioneering achievement to establish CLM in minimal invasive surgical procedures show a great potential for a more reliable intraoperative evaluation of suspect foci.


Assuntos
Adenocarcinoma/diagnóstico por imagem , Adenoma/diagnóstico por imagem , Neoplasias do Colo/diagnóstico por imagem , Laparoscopia , Microscopia Confocal , Adenocarcinoma/patologia , Adenocarcinoma/cirurgia , Adenoma/patologia , Adenoma/cirurgia , Colectomia , Neoplasias do Colo/patologia , Neoplasias do Colo/cirurgia , Diagnóstico Diferencial , Corantes Fluorescentes , Humanos , Projetos Piloto , Técnicas de Cultura de Tecidos
19.
Diab Vasc Dis Res ; 12(4): 265-71, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25920914

RESUMO

INTRODUCTION: Almost all studies on diabetic foot syndrome focused on prevention of amputation and did not investigate long-term prognosis and survival of patients as a primary outcome parameter. METHODS: We did a retrospective cohort study including 314 patients who had diabetic foot syndrome and underwent amputation between December 1995 and January 2001. RESULTS: A total of 48% of patients received minor amputation (group I), 15% only major amputation (group II) and 36% initially underwent a minor amputation that was followed by a major amputation (group III). Statistically significant differences were observed in comparison of the median survival of group I to group II (51 vs. 40 months; p = 0.016) and of group II to group III (40 vs. 55 months; p = 0.003). DISCUSSION: The prognosis of patients with major amputation due to diabetic foot syndrome is comparable to patients with malignant diseases. Vascular interventions did not improve the individual prognosis of patients.


Assuntos
Amputação Cirúrgica/métodos , Doenças Cardiovasculares/epidemiologia , Diabetes Mellitus/epidemiologia , Pé Diabético/cirurgia , Nefropatias Diabéticas/epidemiologia , Mortalidade , Adulto , Idoso , Idoso de 80 Anos ou mais , Estudos de Coortes , Comorbidade , Pé Diabético/epidemiologia , Feminino , Humanos , Estudos Longitudinais , Masculino , Pessoa de Meia-Idade , Neoplasias/cirurgia , Prognóstico , Estudos Retrospectivos , Taxa de Sobrevida
20.
J Vasc Surg Cases ; 1(1): 57-60, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-31724567

RESUMO

If unilateral common iliac aneurysms occur simultaneously with abdominal aortic aneurysm, endovascular treatment consists of implantation of a bifurcated stent graft with extension into the external iliac artery while the ipsilateral internal iliac artery is often occluded. The internal iliac artery may be preserved by an iliac branch device (IBD). In this technical note, we describe a technique to probe the side branch of an IBD for postdilation through an ipsilateral retrograde access using one balloon to block the way upstream while directing a second percutaneous transluminal angioplasty balloon into the side branch despite the hostile angle of side branch and IBD.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA