Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
NPJ Prim Care Respir Med ; 34(1): 13, 2024 May 28.
Artigo em Inglês | MEDLINE | ID: mdl-38806496

RESUMO

The Test of Adherence to Inhalers (TAI) Toolkit links an adherence measurement instrument (the TAI) to proven effective interventions for different causes of non-adherence to inhaled medication. This study aimed to assess the usability and feasibility of the TAI Toolkit in clinical practice. The TAI Toolkit was piloted in eight primary and secondary care settings. Each study site included 10 patients with asthma and/or COPD and suspected non-adherence. Healthcare professionals (HCPs) recorded clinical data and TAI Toolkit outcomes. Data on usability and feasibility were collected in semi-structured interviews and with the System Usability Score (SUS). Of the included patients, 81% were non-adherent, and sporadic non-adherence was the most common (69%). The TAI Toolkit was valued with a mean SUS-score of 85.9 by the HCPs. They found the toolkit to 'be visually attractive', 'easy-to-use' and 'give insight into patients' adherence', thereby offering good potential for its use in clinical practice.


Assuntos
Asma , Estudos de Viabilidade , Adesão à Medicação , Nebulizadores e Vaporizadores , Doença Pulmonar Obstrutiva Crônica , Humanos , Adesão à Medicação/estatística & dados numéricos , Masculino , Doença Pulmonar Obstrutiva Crônica/tratamento farmacológico , Feminino , Pessoa de Meia-Idade , Asma/tratamento farmacológico , Administração por Inalação , Idoso , Adulto
2.
Respir Med ; 218: 107376, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37549796

RESUMO

BACKGROUND: Poor adherence to inhaled medication has been associated with poor outcomes. Smart spacers can monitor inhaler use and technique, yet their feasibility in adults with asthma and their potential benefits are unknown. OBJECTIVE: Assessing the feasibility of undertaking a definitive randomized controlled trial (RCT) of smart spacer-based inhaler education and explore potential clinical benefits in adults with asthma. METHODS: Two-month randomized controlled feasibility OUtcomes following Tailored Education and Retraining: Studying Performance and AdherenCE (OUTERSPACE) trial comparing personalized smart spacer-based inhaler education versus usual care. Patients were recruited in four Dutch primary care centres. Outcomes were feasibility (inclusion speed, patient acceptance), medication adherence, inhaler technique, clinical effects (lung function, ACQ, FeNO) and usability (System Usability Scale [SUS]). RESULTS: 42 patients were randomized and all completed the study. The feasibility of performing a larger trial focusing on asthma patient education using a smart spacer was demonstrated with all patients included in four months and a participation rate of 86%. In the intervention group, inhalation errors per day decreased by 26.2% while in the usual care group inhalation errors increased by 14.6% (p = 0.021). Adherence decreased slightly in the intervention group as opposed to improvement in the control group (difference 12%, p = 0.028). No changes in lung function, ACQ or FeNO were observed. Usability was deemed high (SUS patients 71, nurses 89). CONCLUSION: This RCT showed that smart spacer-driven education in patients with asthma is feasible and in this short-term study reduced inhaler errors. Longer-term and larger studies are required to assess clinical effects.


Assuntos
Asma , Adulto , Humanos , Asma/tratamento farmacológico , Nebulizadores e Vaporizadores , Administração por Inalação , Inaladores Dosimetrados , Adesão à Medicação , Eletrônica
3.
Respir Med ; 201: 106940, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35933835

RESUMO

Pressurized metered dose inhalers are recommended to be used in combination with spacers, yet inhaler technique and adherence are poor. A novel digital "smart" spacer can record spacer use and technique errors and could facilitate personalized education. In this proof-of-concept study, we assessed the usability of the digital spacer and explored its effects on inhaler technique, adherence, long-term systemic drug exposure and clinical outcomes in COPD. Usability was deemed high. One month after personalized digital spacer inhaler education, the mean number of errors per patient per day decreased with 36%, from 6.40 errors/day to 4.07 errors/day (p = 0.038). Drug exposure was confirmed by bioanalytical scalp hair analysis of formoterol. No significant change in clinical outcomes was observed. This study demonstrates the digital spacer's potential value in inhaler education, but larger, longer-term studies are required.


Assuntos
Broncodilatadores , Doença Pulmonar Obstrutiva Crônica , Administração por Inalação , Broncodilatadores/uso terapêutico , Fumarato de Formoterol/uso terapêutico , Humanos , Inaladores Dosimetrados , Nebulizadores e Vaporizadores , Doença Pulmonar Obstrutiva Crônica/tratamento farmacológico
4.
Clin Exp Allergy ; 52(11): 1247-1263, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-35947495

RESUMO

This review presents an overview of the available literature regarding intranasal corticosteroids (INCs) for the treatment of allergic rhinitis (AR). Various treatment options exist for AR including INCs, antihistamines and leucotriene antagonists. INCs are considered to be the most effective therapy for moderate-to-severe AR, as they are effective against nasal and ocular symptoms and improve quality of life. Their safety has been widely observed. INCs are effective and safe for short-term use. Local adverse events are observed but generally well-tolerated. The occurrence of (serious) systemic adverse events is unlikely but cannot be ruled out. There is a lack of long-term safety data. INC may cause serious eye complications. The risk of INCs on the hypothalamic-pituitary-adrenal axis, on bone mineral density reduction or osteoporosis and on growth in children, should be considered during treatment. Pharmacological characteristics of INCs (e.g. the mode of action and pharmacokinetics) are well known and described. We sought to gain insight into whether specific properties affect the efficacy and safety of INCs, including nasal particle deposition, which the administration technique affects. However, advances are lacking regarding the improved understanding of the effect of particle deposition on efficacy and safety and the effect of the administration technique. This review emphasizes the gaps in knowledge regarding this subject. Advances in research and health care are necessary to improve care for patients with AR.


Assuntos
Qualidade de Vida , Rinite Alérgica , Criança , Humanos , Sistema Hipotálamo-Hipofisário , Sistema Hipófise-Suprarrenal , Rinite Alérgica/tratamento farmacológico , Corticosteroides , Administração Intranasal , Antagonistas dos Receptores Histamínicos/uso terapêutico
5.
BMJ Open ; 12(6): e059929, 2022 06 13.
Artigo em Inglês | MEDLINE | ID: mdl-35697450

RESUMO

INTRODUCTION: Medication adherence and inhaler technique in patients with asthma remain suboptimal. A digital, smart spacer may support personalised adherence and inhaler technique education. The aim of this study is to assess the feasibility of undertaking a definitive randomised controlled trial of personalised, smart spacer data-driven education and explore clinical benefits. METHODS AND ANALYSIS: We present the design of the multicentre, randomised controlled OUtcomes following Tailored Education and Retraining: Studying Performance and AdherenCE feasibility trial of 2 months. Patients will be recruited from four Dutch general practices. At t=-1, patients with asthma ≥18 years using inhaled corticosteroids±long-acting beta-agonists±short-acting beta-agonists administered with a pressurised-metered-dose-inhaler and spacer (n=40) will use a smart spacer for 1 month. The rechargeable CE-marked smart spacer (Aerochamber Plus with Flow Vu) includes a sensor that monitors adherence and inhalation technique to prescribed dosing regimen of both maintenance and reliever inhalers. After 1 month (t=0), patients are 1:1 randomised into two groups: control group (usual care) versus intervention group (personalised education). At t=-1, t=0 and t=1 month, the Asthma Control Questionnaire (ACQ), Work Productivity and Activity Impairment (WPAI) questionnaire and Test of Adherence to Inhalers (TAI) are administered and fractional exhaled nitric oxide (FeNO) is assessed. At t=0 and t=1, spirometry is performed. At t=1, usability and satisfaction will be analysed using the System Usability Scale and interviews with patients and healthcare providers. Primary outcome is the overall feasibility of a definitive trial assessed by patient recruitment speed, participation and drop-out rate. Secondary outcomes are patient and healthcare provider satisfaction and exploratory clinical outcomes are adherence, inhaler technique, TAI score, FeNO, lung function, ACQ and WPAI. ETHICS AND DISSEMINATION: Ethical approval was obtained from the RTPO in Leeuwarden, Netherlands (number: NL78361.099.21). Patients will provide written informed consent. Study findings will be disseminated through conferences and peer-reviewed scientific and professional journals. TRIAL REGISTRATION NUMBER: NL9637.


Assuntos
Asma , Broncodilatadores , Administração por Inalação , Asma/tratamento farmacológico , Eletrônica , Humanos , Adesão à Medicação , Estudos Multicêntricos como Assunto , Nebulizadores e Vaporizadores , Ensaios Clínicos Controlados Aleatórios como Assunto
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA