Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
J Heart Valve Dis ; 10(4): 495-504, 2001 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-11499597

RESUMO

BACKGROUND AND AIM OF THE STUDY: The use of flexible structures within cardiovascular prostheses such as valves, stents and vascular grafts has been proposed as a means of more closely modeling native mechanics, and thereby reducing the biomechanical problems associated with rigid materials. However, the design of such materials has been hampered by the paucity of quantitative information on the in-vivo behavior of such structures. The aim of this study was to explore the use of 3D ultrasound imaging coupled with finite element analysis (FEA) as a tool to estimate deformation and forces imposed in vivo on a novel bioprosthetic valve design. METHODS: The method was first tested using in-vitro static loading conditions, where good agreement between displacements seen on video and those obtained from application of the identical force within the finite element program was seen. The method was then tested in a porcine model with valves implanted in the mitral position. Images of the deforming annular ring were obtained over the cardiac cycle using 3D intravascular ultrasound; these images were fed into the FEA program for calculation of reaction forces. RESULTS: Results in vitro showed that a force of 2.7-8.0 Newtons (N) was required to produce a deformation of between 1.0 and 3.0 mm in the radial direction. A time history of deformation and force around the ring of the valve stent could be obtained for the in-vivo conditions. These results revealed a maximum deformation of 0.5-1.7 mm along the short axis (anteroposterior) of the mitral valve. Coupled to this, a peak reaction force of 4.4-13.9 N was found at the points corresponding to maximal deflection. Both deformation and reaction force reached maximum during atrial contraction. CONCLUSION: This method provides an accurate means of estimating deformation and corresponding forces imposed in vivo on intracardiac prostheses. The results provide information on the dynamic behavior of the mitral valve annulus. Such information should be useful in the design of flexible cardiovascular prostheses.


Assuntos
Bioprótese , Ecocardiografia Tridimensional , Análise de Elementos Finitos , Próteses Valvulares Cardíacas , Valva Mitral/diagnóstico por imagem , Ultrassonografia de Intervenção , Animais , Fenômenos Biomecânicos , Humanos , Técnicas In Vitro , Valva Mitral/transplante , Projetos de Pesquisa , Suínos
3.
J Pediatr ; 138(3): 349-54, 2001 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-11241041

RESUMO

OBJECTIVE: To determine the cardiovascular outcome of a group of term newborns treated with inhaled nitric oxide (iNO) for severe hypoxemic respiratory failure with associated persistent pulmonary hypertension. STUDY DESIGN: We performed echocardiographic evaluations in 40 survivors treated for severe neonatal hypoxemic respiratory failure. Each of the 40 had at least 2 follow-up echocardiograms at 3 or 6 and 24 months. These studies were compared with echocardiograms done in infants in a normal, age-matched control group. RESULTS: Three of 31 infants met echocardiographic criteria for pulmonary hypertension at the 3-month examination. Two of the 3 had associated structural heart disease (1 with an atrial septal defect and 1 with a ventricular septal defect). At 24 months only 1 patient had pulmonary hypertension. This infant had an atrial septal defect that was surgically closed shortly after the 24-month echocardiogram because of the pulmonary hypertension. Group comparisons of 3- and 24-month echocardiographic variables showed no differences between the study and control groups. In the 31 infants in whom serial studies were completed, expected age-related changes were demonstrated between the 3- and 24-month examinations. CONCLUSIONS: The incidence of residual pulmonary hypertension in infants treated as newborns for severe hypoxemic respiratory failure is low. The group at highest risk is those with structural heart disease.


Assuntos
Ecocardiografia Doppler , Hipóxia/tratamento farmacológico , Óxido Nítrico/uso terapêutico , Síndrome da Persistência do Padrão de Circulação Fetal/etiologia , Insuficiência Respiratória/tratamento farmacológico , Administração por Inalação , Estudos de Casos e Controles , Seguimentos , Cardiopatias Congênitas/complicações , Humanos , Hipóxia/complicações , Incidência , Recém-Nascido , Síndrome da Persistência do Padrão de Circulação Fetal/diagnóstico por imagem , Síndrome da Persistência do Padrão de Circulação Fetal/epidemiologia , Insuficiência Respiratória/complicações , Fatores de Risco , Estados Unidos/epidemiologia
4.
J Am Soc Echocardiogr ; 13(10): 924-31, 2000 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-11029717

RESUMO

Aortic arch anomalies usually require surgical intervention preceded by precise anatomic definition. We studied 20 patients to evaluate the feasibility and accuracy of using intravascular ultrasound catheters from a transesophageal approach with 3-dimensional image reconstruction for the diagnosis of aortic arch anomalies in infants and children. All patients had transthoracic echocardiograms and/or angiograms or magnetic resonance imaging. A 12.5-MHz intravascular ultrasound catheter was positioned in the esophagus and withdrawn by using an electrocardiogram and a respiratory gated pullback device to acquire the mediastinal images. All patients with arch anomalies underwent surgical repair. Reconstructed images were analyzed in the "anyplane" mode and with surface rendering. Intravascular ultrasound 3-dimensional imaging was successfully accomplished without complications. Anatomy was correctly identified in all patients by both blinded and unblinded observers, thus confirming the sensitivity and accuracy of the technique. We foresee this new technique to be useful as an adjunctive imaging modality applicable at the bedside or in the cardiac imaging laboratory.


Assuntos
Aorta Torácica/anormalidades , Coartação Aórtica/diagnóstico por imagem , Ecocardiografia Tridimensional , Ecocardiografia Transesofagiana , Ultrassonografia de Intervenção/métodos , Pré-Escolar , Estudos de Viabilidade , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Lactente , Recém-Nascido , Masculino , Sensibilidade e Especificidade
5.
Am J Cardiol ; 81(6): 740-8, 1998 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-9527085

RESUMO

We sought to describe the morphologic characteristics of pulmonary arteries by intravascular ultrasound (IVUS) in children with and without pulmonary hypertension to compare these anatomic findings with those of pulmonary wedge angiography, and to determine the relation between these structural findings and functional reactivity to pulmonary vasodilators. Direct evaluation of pulmonary vascular structure in children with pulmonary hypertension with current imaging techniques has been limited and little is known about the relation between structural and functional characteristics of the pulmonary vasculature. In 23 children undergoing cardiac catheterization (15 with pulmonary hypertension and 8 controls) we performed IVUS and pulmonary wedge angiography of the distal pulmonary arteries in the same lobe. IVUS was performed in 44 pulmonary arteries measuring 2.5 to 5.0 mm internal diameter with a 3.5Fr 30-MHz IVUS catheter. We assessed vasoreactivity to inhaled nitric oxide (NO) and oxygen in 13 of 15 children with pulmonary hypertension. Baseline pulmonary vascular resistance (PVR) was greater in the 15 children with pulmonary hypertension than in the 8 controls (9.5+/-1.9 vs 1.5+/-0.3 U x m2, p <0.05). NO lowered PVR in patients with pulmonary hypertension (p <0.05). IVUS studies in patients with pulmonary hypertension showed a thicker middle layer, wall thickness ratio, and diminished pulsatility than did those in controls (p <0.05). The inner layer was not visualized by IVUS in any control patient, but was seen in 9 of 15 patients with pulmonary hypertension. Pulmonary artery wedge angiography correlated with baseline mean pulmonary artery pressure and PVR as well as with IVUS findings of wall thickness ratio and inner layer thickness. The inner layer was not visualized by IVUS in any patient with grade 1 wedge angiograms or in 86% of patients with grade 2 wedge angiograms. All patients with grade 4 and 80% of patients with grade 3 wedge angiograms had a visible inner layer. Vasoreactivity to NO and oxygen did not correlate with structural assessment of the pulmonary vasculature by IVUS. Structural changes in the pulmonary arteries in children with pulmonary hypertension can be directly visualized by IVUS, but are not predictive of NO-induced pulmonary vasodilation. IVUS examination of pulmonary arteries may complement current techniques utilized in the evaluation of children with pulmonary hypertension.


Assuntos
Hipertensão Pulmonar/diagnóstico por imagem , Hipertensão Pulmonar/patologia , Artéria Pulmonar/diagnóstico por imagem , Artéria Pulmonar/patologia , Ultrassonografia de Intervenção , Administração por Inalação , Angiografia , Estudos de Casos e Controles , Criança , Pré-Escolar , Humanos , Hipertensão Pulmonar/fisiopatologia , Óxido Nítrico/administração & dosagem , Óxido Nítrico/farmacologia , Oxigênio/administração & dosagem , Oxigênio/farmacologia , Artéria Pulmonar/efeitos dos fármacos , Artéria Pulmonar/fisiopatologia , Circulação Pulmonar/efeitos dos fármacos , Análise de Regressão , Vasodilatadores/administração & dosagem , Vasodilatadores/farmacologia
6.
J Am Coll Cardiol ; 24(3): 813-9, 1994 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-8077557

RESUMO

OBJECTIVES: The purpose of the present study was to rigorously evaluate the accuracy of the color Doppler jet area planimetry method for quantifying chronic mitral regurgitation. BACKGROUND: Although the color Doppler jet area has been widely used clinically for evaluating the severity of mitral regurgitation, there have been no studies comparing the color jet area with a strictly quantifiable reference standard for determining regurgitant volume. METHODS: In six sheep with surgically produced chronic mitral regurgitation, 24 hemodynamically different states were obtained. Maximal color Doppler jet area for each state was obtained with a Vingmed 750. Image data were directly transferred in digital format to a microcomputer. Mitral regurgitation was quantified by the peak and mean regurgitant flow rates, regurgitant stroke volumes and regurgitant fractions determined using mitral and aortic electromagnetic flow probes. RESULTS: Mean regurgitant volumes varied from 0.19 to 2.4 liters/min (mean [+/- SD] 1.2 +/- 0.59), regurgitant stroke volumes from 1.8 to 29 ml/beat (mean 11 +/- 6.2), peak regurgitant volumes from 1.0 to 8.1 liters/min (mean 3.5 +/- 2.1) and regurgitant fractions from 8.0% to 54% (mean 29 +/- 12%). Twenty-two of 24 jets were eccentric. Simple linear regression analysis between maximal color jet areas and peak and mean regurgitant flow rates, regurgitant stroke volumes and regurgitant fractions showed correlation, with r = 0.68 (SEE 0.64 cm2), r = 0.63 (SEE 0.67 cm2), r = 0.63 (SEE 0.67 cm2) and r = 0.58 (SEE 0.71 cm2), respectively. Univariate regression comparing regurgitant jet area with cardiac output, stroke volume, systolic left ventricular pressure, pressure gradient, left ventricular/left atrial pressure gradient, left atrial mean pressure, left atrial v wave pressure, systemic vascular resistance and maximal jet velocity showed poor correlation (0.08 < r < 0.53, SEE > 0.76 cm2). CONCLUSIONS: This study demonstrates that color Doppler jet area has limited use for evaluating the severity of mitral regurgitation with eccentric jets.


Assuntos
Ecocardiografia Doppler , Insuficiência da Valva Mitral/diagnóstico por imagem , Animais , Valva Aórtica/fisiopatologia , Pressão Sanguínea , Doença Crônica , Ecocardiografia Doppler/métodos , Ecocardiografia Doppler/normas , Fenômenos Eletromagnéticos , Processamento de Imagem Assistida por Computador , Valva Mitral/fisiopatologia , Insuficiência da Valva Mitral/fisiopatologia , Análise Multivariada , Variações Dependentes do Observador , Valor Preditivo dos Testes , Padrões de Referência , Fluxo Sanguíneo Regional , Análise de Regressão , Reologia , Ovinos , Volume Sistólico
7.
J Appl Physiol (1985) ; 72(5): 2005-17, 1992 May.
Artigo em Inglês | MEDLINE | ID: mdl-1601812

RESUMO

A previous optimal chemical-mechanical model (C.-S. Poon. J. Appl. Physiol. 62: 2447-2459, 1987) suggested that the normal ventilatory responses to CO2 and exercise inputs and mechanical loading can be predicted by the minimization of a controller objective function consisting of the total chemical and mechanical costs of breathing. In this study the model was generalized to include a description of the inspiratory neuromuscular drive as the control output. With a mechanical work rate index for both inspiration and expiration, the general optimization model accurately reproduced the observed responses in the waveshape of inspiratory drive, breathing pattern, and total ventilation under differing conditions of CO2 inhalation, exercise, and inspiratory/expiratory mechanical loads. The simulation results are in general agreement with a wide range of respiratory phenomena, including exercise hyperpnea, CO2 chemoreflex, and post-inspiratory (postinflow) inspiratory activity, as well as respiratory neural compensations for mechanical loading, respiratory muscle fatigue, and muscle weakness.


Assuntos
Modelos Biológicos , Mecânica Respiratória/fisiologia , Animais , Células Quimiorreceptoras/fisiologia , Simulação por Computador , Retroalimentação , Humanos , Mecanorreceptores/fisiologia , Bulbo/fisiologia , Troca Gasosa Pulmonar/fisiologia
8.
Circulation ; 83(3): 1023-7, 1991 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-1999007

RESUMO

BACKGROUND: Recent advances in miniaturization of phased-array and mechanical ultrasound devices have resulted in exploration of alternative approaches to cardiac and vascular imaging in the form of transesophageal or intravascular imaging. Preliminary efforts in adapting phased-array endoscopes designed for transesophageal use to a transvascular approach have used full-sized phased-array devices introduced directly into the right atrium in open-chested animals. The purpose of this study was to assess the feasibility of using a custom-made, very small phased-array endoscope for intracardiac imaging introduced intravascularly through a jugular venous approach in young piglets. METHODS AND RESULTS: Experimental atrial septal defects created in four piglets (3-4 weeks old) had been closed with a buttoned atrial septal defect closure device consisting of an occluder in the left atrium and a counteroccluder in the right atrium. Five to 15 days after atrial septal defect closure, the piglets were returned to the experimental laboratory, where a 6.3-mm, 17-element, 5-MHz phased-array probe mounted on a 4-mm endoscope was introduced through a cutdown incision of the external jugular vein and advanced to the right atrium. From the right atrium all four cardiac chambers, their inflows and outflows, and all four valves were well imaged with minimal superior and inferior rotation. High-resolution imaging of the atrial septum defined with anatomical accuracy, later verified by autopsy, the exact placement of both the occluder and counteroccluder in the left and right sides of the atrial septal defects and the absence of any shunting across the atrial septum in any of the four animals. CONCLUSIONS: Our efforts indicate that transvascular passage of small phased-array probes can be easily accomplished and is a promising technique for detailed visualization of cardiac structures. This approach may provide an alternative to transesophageal echocardiography, particularly for guiding interventional procedures such as placement of transcatheter closure devices in pediatric patients.


Assuntos
Ecocardiografia/instrumentação , Endoscópios , Animais , Estudos de Viabilidade , Átrios do Coração/diagnóstico por imagem , Comunicação Interatrial/diagnóstico por imagem , Miniaturização , Suínos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA