Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Biosensors (Basel) ; 14(2)2024 Jan 31.
Artigo em Inglês | MEDLINE | ID: mdl-38391995

RESUMO

This present work is aimed at conducting fundamental and exploratory studies of the mechanisms of electrical impedance signal formation. This paper also considers morphofunctional changes in forearm tissues during the performance of basic hand actions. For this purpose, the existing research benches were modernized to conduct experiments of mapping forearm muscle activity by electrode systems on the basis of complexing the electrical impedance signals and electromyography signals and recording electrode systems' pressing force using force transducers. Studies were carried out with the involvement of healthy volunteers in the implementation of vertical movement of the electrode system and ultrasound transducer when the subject's upper limb was positioned in the bed of the stand while performing basic hand actions in order to identify the relationship between the morphofunctional activity of the upper limb muscles and the recorded parameters of the electro-impedance myography signal. On the basis of the results of the studies, including complex measurements of neuromuscular activity on healthy volunteers such as the signals of electro-impedance myography and pressing force, analyses of the morphofunctional changes in tissues during action performance on the basis of ultrasound and MRI studies and the factors influencing the recorded signals of electro-impedance myography are described. The results are of fundamental importance and will enable reproducible electro-impedance myography signals, which, in turn, allow improved anthropomorphic control.


Assuntos
Contração Muscular , Músculo Esquelético , Humanos , Impedância Elétrica , Eletromiografia , Contração Muscular/fisiologia , Miografia/métodos
2.
J Electr Bioimpedance ; 14(1): 13-18, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37416524

RESUMO

The aim of the proposed study is to reveal the correlations between the dynamics of Respiratory Rate (RR) and Heart Rate (HR) during intermittent physical work at maximum power on a cycle ergometer. The stage of investigating the General functional athlete readiness (GFAR) was conducted using the sports standard "R-Engine" and the cycle ergometer in 16 volunteers (10 men, 6 women) whose average age was 21±1.17 years. To determine the athletic potential of the volunteers in this study, we used our own Coefficient of Anaerobic Capacity (CANAC Q, beats). Continuous registration of the heart rate and respiratory rate of volunteers in the maximum power sports test was performed by the "RheoCardioMonitor" system with a module of the athlete functional readiness based on the method of Transthoracic electrical impedance rheography (TEIRG). The degree of correlation of functional indicators (M, HRM, GFAR) with CANAC Q in all experimental series of the study group as a whole (n=80) was at a very high level, which confirmed the effectiveness of using the Coefficient of Anaerobic Capacity (CANAC Q) in assessing the general functional athlete readiness of the volunteers. CANAC Q is measured in "beats" of the heart and is recorded very accurately using the method of transthoracic electrical impedance rheography (TEIRG). For this reason, as a promising sports PSM-system, CANAC Q can replace the methods for determining the functional athlete readiness by blood lactate concentration and maximum oxygen consumption.

3.
J Electr Bioimpedance ; 13(1): 45-53, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36196240

RESUMO

At present, there are no hardware or biochemical systems that allow to assess the severity of post-COVID syndrome in vivo. The hardware of the proposed biotechnical system is based on routine transthoracic electrical impedance rheography, which makes it possible to register the frequency characteristics of the patient's bioimpedance response to controlled stress stimulation, thereby simultaneously fixing the characteristics of his productive heart, the state of the hemomicrocirculatory bed, the efficiency of the gas transport function of his blood, and also reliably assess personal reactivity and adaptive potential. Subsequent mathematical approximation of the obtained biometric data by an original neural network makes it possible to rank the results obtained and automatically generate a program of medical rehabilitation for a particular patient, depending on the severity of his post-COVID syndrome. The study results proved two reliable physiological signs confirming the presence of latent post-COVID complications: a decrease in the base impedance value for light exercise and an increase in the length of the systolic arc of the rheocardiogram.

4.
Sensors (Basel) ; 22(5)2022 Mar 02.
Artigo em Inglês | MEDLINE | ID: mdl-35271088

RESUMO

The detection of muscle contraction and the estimation of muscle force are essential tasks in robot-assisted rehabilitation systems. The most commonly used method to investigate muscle contraction is surface electromyography (EMG), which, however, shows considerable disadvantages in predicting the muscle force, since unpredictable factors may influence the detected force but not necessarily the EMG data. Electrical impedance myography (EIM) investigates the change in electrical impedance during muscle activities and is another promising technique to investigate muscle functions. This paper introduces the design, development, and evaluation of a device that performs EMG and EIM simultaneously for more robust measurement of muscle conditions subject to artifacts. The device is light, wearable, and wireless and has a modular design, in which the EMG, EIM, micro-controller, and communication modules are stacked and interconnected through connectors. As a result, the EIM module measures the bioimpedance between 20 and 200 Ω with an error of less than 5% at 140 SPS. The settling time during the calibration phase of this module is less than 1000 ms. The EMG module captures the spectrum of the EMG signal between 20-150 Hz at 1 kSPS with an SNR of 67 dB. The micro-controller and communication module builds an ARM-Cortex M3 micro-controller which reads and transfers the captured data every 1 ms over RF (868 Mhz) with a baud rate of 500 kbps to a receptor connected to a PC. Preliminary measurements on a volunteer during leg extension, walking, and sit-to-stand showed the potential of the system to investigate muscle function by combining simultaneous EMG and EIM.


Assuntos
Contração Muscular , Dispositivos Eletrônicos Vestíveis , Impedância Elétrica , Eletromiografia/métodos , Humanos , Músculos
5.
Sensors (Basel) ; 22(1)2021 Dec 24.
Artigo em Inglês | MEDLINE | ID: mdl-35009640

RESUMO

The electrical impedance myography method is widely used in solving bionic control problems and consists of assessing the change in the electrical impedance magnitude during muscle contraction in real time. However, the choice of electrode systems sizes is not always properly considered when using the electrical impedance myography method in the existing approaches, which is important in terms of electrical impedance signal expressiveness and reproducibility. The article is devoted to the determination of acceptable sizes for the electrode systems for electrical impedance myography using the Pareto optimality assessment method and the electrical impedance signals formation model of the forearm area, taking into account the change in the electrophysical and geometric parameters of the skin and fat layer and muscle groups when performing actions with a hand. Numerical finite element simulation using anthropometric models of the forearm obtained by volunteers' MRI 3D reconstructions was performed to determine a sufficient degree of the forearm anatomical features detailing in terms of the measured electrical impedance. For the mathematical description of electrical impedance relationships, a forearm two-layer model, represented by the skin-fat layer and muscles, was reasonably chosen, which adequately describes the change in electrical impedance when performing hand actions. Using this model, for the first time, an approach that can be used to determine the acceptable sizes of electrode systems for different parts of the body individually was proposed.


Assuntos
Músculo Esquelético , Miografia , Impedância Elétrica , Eletrodos , Humanos , Reprodutibilidade dos Testes
6.
Sensors (Basel) ; 22(1)2021 Dec 27.
Artigo em Inglês | MEDLINE | ID: mdl-35009694

RESUMO

Creating highly functional prosthetic, orthotic, and rehabilitation devices is a socially relevant scientific and engineering task. Currently, certain constraints hamper the development of such devices. The primary constraint is the lack of an intuitive and reliable control interface working between the organism and the actuator. The critical point in developing these devices and systems is determining the type and parameters of movements based on control signals recorded on an extremity. In the study, we investigate the simultaneous acquisition of electric impedance (EI), electromyography (EMG), and force myography (FMG) signals during basic wrist movements: grasping, flexion/extension, and rotation. For investigation, a laboratory instrumentation and software test setup were made for registering signals and collecting data. The analysis of the acquired signals revealed that the EI signals in conjunction with the analysis of EMG and FMG signals could potentially be highly informative in anthropomorphic control systems. The study results confirm that the comprehensive real-time analysis of EI, EMG, and FMG signals potentially allows implementing the method of anthropomorphic and proportional control with an acceptable delay.


Assuntos
Biônica , Miografia , Impedância Elétrica , Eletromiografia , Movimento , Punho
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA