Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
2.
Platelets ; 22(1): 20-7, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-20873965

RESUMO

Insufficient response on antiplatelet medication has become an intensively discussed issue because of the risk factor of recurrent adverse cardiovascular events. However, the monitoring of antiplatelet therapy requires appropriate, robust and reliable test methods. For the measurement of thienopyridine effects, the manufacturer of the PFA-100® System provides the INNOVANCE® PFA P2Y * cartridge. We tested this cartridge for its capacity to detect the inhibition of the P2Y12 receptor, which is the target for thienopyridine medication (e.g. clopidogrel). We compared the INNOVANCE® PFA P2Y * results with those obtained by the receptor specific flow cytometric vasodilator stimulated phosphoprotein (VASP) assay that expresses the status of the P2Y12 receptor as "platelet reactivity index" (PRI). The in vitro addition of the P2Y12 receptor antagonist cangrelor (AR-C69931MX) to citrated human whole blood resulted in a dose-dependent prolongation of closure times (CTs) of the INNOVANCE® PFA P2Y * cartridge correlating with decreased PRI levels. In volunteers, the intake of a 600 mg clopidogrel loading dose caused an increase of the CTs in all volunteers, although some of these volunteers were identified as "poor responders" by the VASP assay (no significant reduction of PRI levels). In 50 patients with stable coronary artery disease undergoing percutaneous coronary intervention (PCI) and under dual antiplatelet therapy, the new cartridge had a detection rate of 84% (CT 106 s as cut-off) for clopidogrel medication. After dividing the 50 patients into two groups according to their response to clopidogrel INNOVANCE® PFA P2Y * recognized all "responders" (defined by a PRI > 50%) using >106 s as cut-off but the specificity for a "good response" was only 42% because several "poor responders" (defined by a PRI > 50%) also showed CTs above the cut-off. The best correlation (substantial agreement) between the results of INNOVANCE® PFA P2Y * and of the VASP phosphorylation assay was achieved using CT > 200 s and PRI < 55% as cut-offs. Then, the sensitivity of INNOVANCE® PFA P2Y * was 97% and the specificity for a "good response" 65%. In summary, INNOVANCE® PFA P2Y * showed a high sensitivity for the detection of P2Y12 receptor blockade, but had only a limited specificity for a "good response" to clopidogrel. Therefore, this new cartridge is a useful tool to rule out P2Y12 receptor inhibition, if normal or only slightly prolonged CTs are obtained. Its predictive value for risk assessment of thromboembolic events, e.g. after coronary stent implantation, needs to be evaluated in clinical trials.


Assuntos
Plaquetas/efeitos dos fármacos , Inibidores da Agregação Plaquetária/farmacologia , Antagonistas do Receptor Purinérgico P2/farmacologia , Ticlopidina/análogos & derivados , Monofosfato de Adenosina/análogos & derivados , Monofosfato de Adenosina/farmacologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Bioensaio , Biomarcadores/sangue , Plaquetas/metabolismo , Estudos de Casos e Controles , Moléculas de Adesão Celular/metabolismo , Clopidogrel , Doença da Artéria Coronariana/tratamento farmacológico , Feminino , Citometria de Fluxo , Humanos , Masculino , Proteínas dos Microfilamentos/metabolismo , Pessoa de Meia-Idade , Fosfoproteínas/metabolismo , Fosforilação/efeitos dos fármacos , Inibidores da Agregação Plaquetária/uso terapêutico , Valor Preditivo dos Testes , Antagonistas do Receptor Purinérgico P2/uso terapêutico , Receptores Purinérgicos P2/sangue , Sensibilidade e Especificidade , Ticlopidina/farmacologia , Ticlopidina/uso terapêutico , Adulto Jovem
3.
Platelets ; 21(2): 112-6, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-20085435

RESUMO

The rationale for monitoring platelet inhibition by thienopyridines for the identification of patients at risk for future recurrent arterial thrombosis or ischemic events is intensively discussed, as well as which monitoring systems are appropriate, robust and reliable. Flow cytometric measurement of phosphorylated VASP (vasodilator-stimulated phosphoprotein), expressed as platelet reactivity index (PRI), is presently "the gold standard method" for evaluating P2Y(12) receptor inhibition. The PFA-100 system, a commercially available and clinically widely used platelet test system, is based on a different principle, not that of VASP phosphorylation. The aim of the present study was to compare the two methods and evaluate whether the conventional PFA-100 collagen/ADP cartridge could be pharmacologically improved to enable its routine clinical use for detection of platelet P2Y(12) receptor inhibition. The effects of increasing concentrations of the competitive P2Y(12) receptor antagonist cangrelor (AR-C69931MX) and the time-dependent effects of a single oral loading dose of clopidogrel (600 mg) were analysed with human whole blood. P2Y(12) receptor inhibition was measured by the VASP/PRI assay and the PFA-100 collagen/ADP cartridge system, with and without preincubation with the prostacyclin analog iloprost (Ilomedin). In vitro addition of iloprost (0.5 nM) enabled PFA-100 collagen/ADP cartridge system detection of P2Y(12) receptor inhibition in whole blood by cangrelor in vitro or by clopidogrel treatment of volunteers. The addition of a prostacyclin analog facilitates PFA-100 collagen/ADP system detection of P2Y(12) receptor inhibition, achieving a sensitivity similar to that of the VASP/PRI reference method. Future studies should now evaluate whether this modified PFA-100 system, like the VASP assay, is a reliable test system for monitoring P2Y(12) receptor inhibition under clinical conditions.


Assuntos
Plaquetas , Citometria de Fluxo , Inibidores da Agregação Plaquetária/farmacologia , Antagonistas do Receptor Purinérgico P2 , Receptores de Epoprostenol/metabolismo , Difosfato de Adenosina/metabolismo , Monofosfato de Adenosina/análogos & derivados , Monofosfato de Adenosina/farmacologia , Adulto , Plaquetas/efeitos dos fármacos , Plaquetas/metabolismo , Moléculas de Adesão Celular/metabolismo , Clopidogrel , Feminino , Citometria de Fluxo/instrumentação , Citometria de Fluxo/métodos , Citometria de Fluxo/normas , Humanos , Iloprosta/farmacologia , Masculino , Proteínas dos Microfilamentos/metabolismo , Pessoa de Meia-Idade , Fosfoproteínas/metabolismo , Fosforilação , Receptores Purinérgicos P2Y12 , Ticlopidina/análogos & derivados , Ticlopidina/farmacologia , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA