Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
J Invasive Cardiol ; 24(8): 390-4, 2012 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-22865309

RESUMO

OBJECTIVES: The Stenting of Saphenous Grafts-Xience V (SOS-Xience V) trial prospectively examined the frequency of angiographic in-stent restenosis in saphenous vein graft (SVG) lesions 12 months after implantation of a Xience V everolimus-eluting stent (EES; Abbott Vascular). Optical coherence tomography (OCT) during follow-up angiography was added to the protocol after OCT was approved for clinical use in the United States. METHODS: Forty patients with 40 SVG lesions were enrolled in the study, of whom 27 underwent 12-month coronary angiography and 12 (only 1 of whom had in-stent restenosis) also had follow-up OCT evaluation. OCT strut-level analysis was performed to determine the percentage of strut coverage, malapposition, strut protrusion, neointimal thickness, and the existence of thrombus. RESULTS: Mean patient age was 67 ± 7 years, and 95% were men. A total of 2584 struts were evaluated by OCT. The percentages for uncovered, malapposed, and protruding struts were 4%, 9%, and 15%, respectively. The mean strut neointimal thickness was 0.094 ± 0.094 mm. Of the 12 stents analyzed, 4 (33%) showed full neointimal coverage, 2 (17%) had all the struts embedded, 7 (58%) had at least 1 malapposed strut, and 10 (83%) had at least 1 protruding strut. The mean difference between the stent area and the lumen area was 0.36 ± 1.6 mm². No thrombus was detected in the stented areas. CONCLUSIONS: Use of EES in SVGs is associated with high rates of stent strut coverage and high malapposition rates at 12 months post implantation.


Assuntos
Doença da Artéria Coronariana/cirurgia , Stents Farmacológicos/efeitos adversos , Oclusão de Enxerto Vascular , Revascularização Miocárdica/efeitos adversos , Veia Safena , Tomografia de Coerência Óptica , Idoso , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/cirurgia , Everolimo , Feminino , Oclusão de Enxerto Vascular/diagnóstico , Oclusão de Enxerto Vascular/etiologia , Oclusão de Enxerto Vascular/fisiopatologia , Oclusão de Enxerto Vascular/terapia , Humanos , Imunossupressores/uso terapêutico , Masculino , Pessoa de Meia-Idade , Monitorização Fisiológica/métodos , Monitorização Fisiológica/estatística & dados numéricos , Revascularização Miocárdica/métodos , Neointima/diagnóstico por imagem , Neointima/fisiopatologia , Intervenção Coronária Percutânea/métodos , Estudos Prospectivos , Medição de Risco/métodos , Veia Safena/diagnóstico por imagem , Veia Safena/fisiopatologia , Veia Safena/transplante , Sirolimo/análogos & derivados , Sirolimo/uso terapêutico , Tomografia de Coerência Óptica/métodos , Tomografia de Coerência Óptica/estatística & dados numéricos , Resultado do Tratamento , Grau de Desobstrução Vascular
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA