Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 37
Filtrar
1.
Talanta ; 277: 126425, 2024 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-38897008

RESUMO

This work reports the development of low-cost and rapid multiplexed colorimetric assay of antioxidants (total phenolics, antioxidant capacity, flavonoids and anthocyanins) in wines at daisy-shaped fluidic paper-based analytical devices (PADs). The desired fluidic patterns were formed on paper by pen drawing and colorimetric reagents were immobilized at the 6 peripheral test zones. The sample was added at the central sample zone, migrated to the test zones and reacted with the immobilized reagents producing characteristic colors that were captured and analyzed. The paper-based approach was applied to the analysis of several wine samples and the results were statistically correlated to standard solution-based colorimetric assays, indicating that it could be reliably used for ranking wines according to their antioxidants content. In addition, the paper-based analytical methodology is simple, instrument-free, portable, cost-effective, rapid and environment friendly.


Assuntos
Antioxidantes , Colorimetria , Papel , Vinho , Vinho/análise , Colorimetria/métodos , Antioxidantes/análise , Antioxidantes/química , Antocianinas/análise , Antocianinas/química , Fenóis/análise , Flavonoides/análise
2.
Anal Methods ; 16(18): 2921-2929, 2024 May 09.
Artigo em Inglês | MEDLINE | ID: mdl-38661387

RESUMO

Carcinoembryonic antigen (CEA) is a glycoprotein widely used as a tumor marker. In this work, a colorimetric lateral flow immunosensor is developed for rapid and low-cost quantification of CEA in human blood serum. The immunosensor consists of a glass fiber sample/conjugation pad, a nitrocellulose detection pad and a cellulose absorption pad. The detection is based on a sandwich immunoreaction: the sample/conjugation pad is modified with gold nanoparticles (GNPs)-labeled anti-CEA conjugate probes which bind to the CEA target molecules in the sample and the complexes are captured at capture anti-CEA immobilized at the test line. The color intensity of the test line, measured from a scanned image of the strip, is related to the CEA concentration in the sample. The different assay parameters are studied in detail. The linearity holds from 1.25 to 640 ng mL-1 of CEA, the instrumental and visual limits of detection are 0.45 and 0.63 ng mL-1, respectively, and the total assay time is 15 min. The specificity of the immunoassay versus other cancer biomarkers is satisfactory. The recovery in samples of human serum spiked with CEA is in the range of 81-118% and the coefficient of variation of the method is ≤10%. Results obtained with the lateral flow immunosensor correlated well with a reference radioimmunoassay method (R2 = 0.99). This immunosensor can be readily applied to CEA monitoring at the point-of-care (POC) or in resource-limited settings thanks to its low-cost and simplicity.


Assuntos
Técnicas Biossensoriais , Antígeno Carcinoembrionário , Ouro , Nanopartículas Metálicas , Antígeno Carcinoembrionário/sangue , Humanos , Imunoensaio/métodos , Nanopartículas Metálicas/química , Ouro/química , Técnicas Biossensoriais/métodos , Limite de Detecção , Colorimetria/métodos , Biomarcadores Tumorais/sangue
3.
Molecules ; 28(24)2023 Dec 17.
Artigo em Inglês | MEDLINE | ID: mdl-38138623

RESUMO

In this work, a simple and cost-efficient aptasensor strip is developed for the rapid detection of OTA in food samples. The biosensor is based on the lateral flow assay concept using an OTA-specific aptamer for biorecognition of the target analyte. The strip consists of a sample pad, a conjugate pad, a nitrocellulose membrane (NC) and an absorbent pad. The conjugate pad is loaded with the OTA-specific aptamer conjugated with gold nanoparticles (AuNPs). The test line of the NC membrane is loaded with a specific OTA-aptamer probe and the control line is loaded with a control probe. The assay is based on a competitive format, where the OTA present in the sample combines with the OTA aptamer-AuNP conjugate and prevents the interaction between the specific probe immobilized on the test line and the OTA aptamer-AuNP conjugates; therefore, the color intensity of the test line decreases as the concentration of OTA in the sample increases. Qualitative detection of OTA is performed visually, while quantification is performed by reflectance colorimetry using a commercial scanner and image analysis. All the parameters of the assay are investigated in detail and the analytical features are established. The visual limit of detection (LOD) of the strip is 0.05 ng mL-1, while the LOD for semi-quantitative detection using reflectance colorimetry is 0.02 ng mL-1. The lateral flow strip aptasensor is applied to the detection of OTA in wine, beer, apple juice and milk samples with recoveries in the range from 91 to 114%. The assay exhibits a satisfactory selectivity for OTA with respect to other mycotoxins and lasts 20 min. Therefore, the lateral flow strip aptasensor could be useful for the rapid, low-cost and fit-for-purpose on-site detection of OTA in food samples.


Assuntos
Aptâmeros de Nucleotídeos , Técnicas Biossensoriais , Nanopartículas Metálicas , Ocratoxinas , Ouro , Ocratoxinas/análise , Técnicas Biossensoriais/métodos , Limite de Detecção
4.
Sensors (Basel) ; 23(18)2023 Sep 10.
Artigo em Inglês | MEDLINE | ID: mdl-37765843

RESUMO

Aptamers are short oligonucleotides designed to possess high binding affinity towards specific target compounds (ions, molecules, or cells). Due to their function and unique advantages, aptamers are considered viable alternatives to antibodies as biorecognition elements in bioassays and biosensors. On the other hand, paper-based devices (PADs) have emerged as a promising and powerful technology for the fabrication of low-cost analytical tools, mainly intended for on-site and point-of-care applications. The present work aims to provide a comprehensive overview of paper-based aptasensors. The review describes the fabrication methods and working principles of paper-based devices, the properties of aptamers as bioreceptors, the different modes of detection used in conjunction with aptasensing PADs, and representative applications for the detection of ions, small molecules, proteins, and cells. The future challenges and prospects of these devices are also discussed.


Assuntos
Aptâmeros de Nucleotídeos , Técnicas Biossensoriais , Aptâmeros de Nucleotídeos/química , Técnicas Biossensoriais/métodos , Anticorpos
5.
Mikrochim Acta ; 190(10): 376, 2023 Sep 02.
Artigo em Inglês | MEDLINE | ID: mdl-37659010

RESUMO

The fabrication of a low-cost eco-friendly sensor platform for the voltammetric determination of trace metals by electrochemical stripping analysis is reported. Plastic conductive electrodes were manufactured via injection moulding from polysterene reinforced with carbon fibres. The platform comprises a carbon counter electrode, a working electrode modified with bismuth nanoparticles generated by spark discharge and a reference electrode coated with AgCl. The sensor fabrication and modification procedures are simple, cost-effective and fast while the materials used are environment-friendly. The utility of the voltammetric platform is demonstrated for stripping analysis of Cd(II) and Pb(II); the limits of detection are 0.7 µg L-1 and 0.6 µg L-1, respectively (with a deposition time of 240 s) which are comparable to conventional Bi-modified sensors and are sufficient to determine the target metals in water and food samples. The scope of the analytical platform for multi-element assays and for the determination of other trace metals is discussed with representative examples. Therefore, this sustainable and economical platform holds great potential for electrochemical sensing of trace metals.

6.
Molecules ; 28(14)2023 Jul 20.
Artigo em Inglês | MEDLINE | ID: mdl-37513411

RESUMO

In this work, a simple, fast, and sensitive voltammetric method for the trace determination of the alkaloid drug colchicine (Colc) using a 3D-printed device is described. The electrochemical method was based on the adsorptive accumulation of the drug at a carbon-black polylactic acid (CB/PLA) working electrode, followed by voltammetric determination of the accumulated species. The plastic sensor was printed in a single step by a low-cost dual extruder 3D-printer and featured three CB/PLA electrodes (serving as working, reference, and counter electrodes) and a holder, printed from a non-conductive PLA filament. The electrochemical parameters that affected the response of the device towards Colc determination, such as accumulation time and potential, solution pH, and other variables, were optimized. Under the selected conditions, the oxidation current of Colc was proportional to the concentration of Colc, and its quantification was conducted in the concentration range of 0.6-2.2 µmol L-1 with a limit of detection of 0.11 µmol L-1 in phosphate buffer (pH 7.0). Both within-device and between-device reproducibility were lower than 9%, revealing satisfactory operational and fabrication reproducibility. Furthermore, the 3D-printed device was employed for the voltammetric determination of Colc in pharmaceutical tablets and in human urine with satisfactory results, justifying its suitability for low-cost routine analysis of Colc.


Assuntos
Colchicina , Poliésteres , Humanos , Reprodutibilidade dos Testes , Eletrodos , Técnicas Eletroquímicas/métodos , Impressão Tridimensional , Preparações Farmacêuticas
7.
Talanta ; 265: 124850, 2023 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-37354623

RESUMO

Mercury is a toxic environmental contaminant that can cause serious health problems. This work describes a new type of eco-friendly three-electrode plastic sensor chip for the determination of trace Hg(II) by means of anodic stripping voltammetry (ASV). The sensor chip is entirely fabricated by injection moulding, which is a sustainable manufacturing method, and consists of three conductive carbon-based electrodes embedded in a plastic holder while the reference electrode is coated with Ag using e-beam evaporation. The sample is spiked with Au(III) which deposits on the working electrode in the form of gold nanoparicles during the analysis; the target Hg(II) co-deposits on the gold nanoparticles forming a Au(Hg) amalgam in situ. The accumulated Hg is stripped off the electrode and quantified by an anodic square wave potential scan. The relevant conditions and the potential interferences are investigated. The limit of detection for Hg(II) is 0.4 µg L-1 and the repeatability at the 20 µg L-1 Hg(III) level (n = 10) is 5.3%. The sensor is applied to water, honey, fish oil and mussel samples with recoveries between 98 and 107%.

8.
Mikrochim Acta ; 190(7): 274, 2023 06 24.
Artigo em Inglês | MEDLINE | ID: mdl-37354230

RESUMO

Estimation of glucose (GLU) levels in the human organism is very important in the diagnosis and monitoring of diabetes. Scientific advances in nanomaterials have led to the construction of new generations of enzymatic-free GLU sensors. In this work, an innovative 3D-printed device modified with a water-stable and non-toxic metal-organic framework of iron (Fe(II)-MOF), which serves as a nanozyme, has been developed for the voltammetric determination of GLU in artificial sweat. In contrast to existing MOF-based GLU sensors which exhibit electrocatalytic activity for the oxidation of GLU in alkaline media, the nanozyme Fe(II)-MOF/3D-printed device can operate in the acidic epidermal sweat environment. The enzymatic-free GLU sensor is composed of a 3-electrode 3D-printed device with the MOF nanozyme immobilized on the surface of the working electrode. GLU sensing is conducted by differential pulse voltammetry without interference from other co-existing metabolites in artificial sweat. The response is based on the oxidation of glucose to gluconolactone, induced by the redox activity of the Fe-centers of the MOF. GLU gives rise to an easily detectable and well-defined voltammetric peak at about - 1.2 V and the limit of detection is 17.6 µmol L-1. The synergy of a nanozyme with 3D printing technology results in an advanced, sensitive, and low-cost sensor, paving the way for on-skin applications.


Assuntos
Glucose , Estruturas Metalorgânicas , Humanos , Glucose/química , Estruturas Metalorgânicas/química , Suor , Impressão Tridimensional , Compostos Ferrosos
9.
Anal Chem ; 95(17): 6765-6768, 2023 05 02.
Artigo em Inglês | MEDLINE | ID: mdl-37079776

RESUMO

Since wood is a renewable, biodegradable naturally occurring material, the development of conductive patterns on wood substrates is a new and innovative chapter in sustainable electronics and sensors. Herein, we describe the first wooden (bio)sensing device fabricated via diode laser-induced graphitization. For this purpose, a wooden tongue depressor (WTD) is laser-treated and converted to an electrochemical multiplex biosensing device for oral fluid analysis. A low-cost laser engraver, equipped with a low-power (0.5 W) diode laser, programmably irradiates the surface of the WTD, forming two mini electrochemical cells (e-cells). The two e-cells consist of four graphite electrodes: two working electrodes, a common counter, and a common reference electrode. The two e-cells are spatially separated via programmable pen-plotting, using a commercial hydrophobic marker pen. Proof-of-principle for biosensing is demonstrated for the simultaneous determination of glucose and nitrite in artificial saliva. This wooden electrochemical biodevice is an easy-to-fabricate disposable point-of-care chip with a wide scope of applicability to other bioassays, while it paves the way for the low-cost and straightforward production of wooden electrochemical platforms.


Assuntos
Técnicas Biossensoriais , Saliva , Madeira , Técnicas Biossensoriais/instrumentação , Técnicas Biossensoriais/métodos , Saliva/química , Gravuras e Gravação , Lasers Semicondutores , Língua , Técnicas Eletroquímicas , Eletrodos
10.
Biosensors (Basel) ; 12(12)2022 Dec 11.
Artigo em Inglês | MEDLINE | ID: mdl-36551123

RESUMO

In this work, a 3D printed sensor modified with a water-stable complex of Fe(III) basic benzoate is presented for the voltammetric detection of glucose (GLU) in acidic epidermal skin conditions. The GLU sensor was produced by the drop-casting of Fe(III)-cluster ethanolic mixture on the surface of a 3D printed electrode fabricated by a carbon black loaded polylactic acid filament. The oxidation of GLU was electrocatalyzed by Fe(III), which was electrochemically generated in-situ by the Fe(III)-cluster precursor. The GLU determination was carried out by differential pulse voltammetry without the interference from common electroactive metabolites presented in sweat (such as urea, uric acid, and lactic acid), offering a limit of detection of 4.3 µmol L-1. The exceptional electrochemical performance of [Fe3O(PhCO2)6(H2O)3]∙PhCO2 combined with 3D printing technology forms an innovative and low-cost enzyme-free sensor suitable for noninvasive applications, opening the way for integrated 3D printed wearable biodevices.


Assuntos
Compostos Férricos , Glucose , Suor , Eletrodos , Impressão Tridimensional , Técnicas Eletroquímicas
11.
Dent Mater ; 38(11): 1721-1727, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-36123188

RESUMO

OBJECTIVES: Three-dimensional (3D) printing technology is a promising technique for fabricating custom orthodontic metallic appliances. Aim of this study was to assess the effect of intraoral aging on the mechanical / electrochemical properties of 3D-printed orthodontic metallic appliances. METHODS: Twelve molar orthodontic distalization appliances 3D-printed from cobalt chromium (Co-Cr) alloy were retrieved after intraoral use and twenty blocks fabricated under similar conditions were used as control. The samples' microstructural / elemental composition assessment was assessed with SEM/EDS, while their mechanical properties (modulus of elasticity [EIT], Martens hardness [HM] and the elastic index [ηIT]) were measured by instrumented indentation testing. Finally, the samples' electrochemical features were assessed with a potentiostat-connected cell arrangement in terms of open circuit potential (OCP), corrosion potential (Ez), current density (I300) and breaking potential (Epit). Results were analyzed by t-test / Mann-Whitney test (α = 0.05). RESULTS: The used Co-Cr alloy was found to have a highly homogenous structure with no significant differences between retrieved and new specimens in HM (4037.7 ± 215.6 vs 4090.9 ± 259.8 N/mm2), EIT (120.0 ± 13.2 vs 123.8 ± 12.9 GPa), or nIT (28.4 ± 2.6 vs 28.6 ± 2.9 %) (P > 0.05 in all instances). Metallic surfaces retained the same oxidation tendency and oxide dissolution rate in passive region in both groups (P > 0.05 for OCP, Ez, and I300). However, intraorally-aged specimens had a significantly lower breakdown potential due to degraded protection efficacy of surface oxide (P = 0.003 for Epit). SIGNIFICANCE: The tested 3D-printed Co-Cr orthodontic appliances present clinically-acceptable mechanical properties that remained unaffected by intraoral ageing, which however degraded the protection of surface oxide against pitting corrosion.


Assuntos
Ligas de Cromo , Aparelhos Ortodônticos , Cromo , Cobalto , Corrosão , Teste de Materiais/métodos , Óxidos , Impressão Tridimensional , Propriedades de Superfície
12.
Dent Mater ; 38(7): 1162-1172, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35690483

RESUMO

OBJECTIVE: To characterize the effect of elemental composition and manufacturing process on the electrochemical properties of Co-Cr-Mo, Co-Cr-W and Co-Cr-Mo-W alloys. METHODS: Six Co-Cr based alloys were included in this study. All alloys are Co-Cr based alloys, classified in three different types according to their elemental composition. The first group has Mo as the third alloying element while the second one has W instead of Mo. The third one has both alloying elements. The groups are further divided by the manufacturing process (casting or Selective Laser Melting(SLM)). All groups were subjected to static immersion, open circuit potential, anodic scan, SEM/EDX analysis, static and cyclic tarnish testing according to ISO 10271 requirements. The ionic release was evaluated by inductively coupled plasma mass spectrometry and the results were statistically analyzed by two way ANOVA and Tukey test (a=0.05). RESULTS: No statistical differences were identified for Co-Cr-Mo alloy for all elements and their total ionic release between casting and SLM manufacturing processes, in contrast to significantly lower values for SLM groups for the other two groups. All groups tested demonstrated similar performance in OCP and AS testing while no gross elemental changes before and after AS were identified following EDX analysis. All alloys fulfilled the requirements of tarnish resistance CONCLUSIONS: The ionic release is dependent on alloy type and manufacturing process while all groups were found to fulfill the requirements of international standards for ionic release, corrosion and tarnish resistance and thus an acceptable clinical performance is anticipated.


Assuntos
Ligas de Cromo , Técnica de Fundição Odontológica , Ligas , Ligas de Cromo/química , Corrosão , Ligas Dentárias/química , Lasers , Teste de Materiais , Propriedades de Superfície
13.
Mikrochim Acta ; 189(6): 240, 2022 05 31.
Artigo em Inglês | MEDLINE | ID: mdl-35641709

RESUMO

The fabrication of fully ink-drawn fluidic electrochemical paper-based analytical devices (ePADs) is reported for the determination of trace Pb(II) and Cd(II) by differential pulse anodic stripping voltammetry (DPASV). The fluidic pattern was formed on the paper substrate using an inexpensive computer-controlled x-y plotter and a commercial hydrophobic marker pen. Then, electrodes were deposited on the devices using a second x-y plotting step with a commercial technical pen filled with a graphite-based conductive ink prepared in house. The fabrication parameters of the ePADs were studied by cyclic voltammetry using the ferro/ferri couple as a probe and by scanning electron microscopy. The ePADs, featuring a bismuth nanoparticle-modified working electrode, were applied to the determination of Pb(II) and Cd(II) by DPASV. The chemical and instrumental conditions were studied. The limits of detection were 3.1 µg L-1 for Cd(II) and 4.5 µg L-1 for Pb(II) whereas the between-device reproducibility (expressed as the % relative standard deviation of the response at 6 different ePADs) was < 14%. Each ePAD requires 120 s to fabricate and costs less than 0.15 € in terms of consumables. The ePADs are suitable for the on-site determination of Pb(II) and Cd(II) in environmental and food samples.


Assuntos
Bismuto , Nanopartículas , Bismuto/química , Cádmio , Eletrodos , Chumbo , Reprodutibilidade dos Testes
14.
Anal Chem ; 94(9): 4087-4094, 2022 03 08.
Artigo em Inglês | MEDLINE | ID: mdl-35195989

RESUMO

In-house digital fabrication of low-cost sensors that can on-site and rapidly detect adulteration of alcoholic beverages with sedation drugs (known as date rape drugs, (DRDs)) and analgesics is of great importance for everyday consumers and supervisory authorities. DRDs and analgesics are administrated in spirits for "drug-facilitated sexual assault" crimes and for the reduction of the following day hangover caused by low-quality spirits, respectively. This work describes, a novel "do-it-yourself" wearable 3D printed electrochemical finger (e-finger), which enables direct, rapid, and multianalyte self-testing of the main DRDs (flunitrazepam, scopolamine, ketamine) and paracetamol via direct immersing into a spirit shot. The oxygen interference on flunitrazepam detection was alleviated by dissolving an effervescent tablet of vitamin C in the spirit shot, as ascorbic acid serves as a scavenger for dissolved oxygen. The e-finger can be printed in-house at any size by anyone with access to a low-cost domestic 3D printer using a simple, fast, and low-cost printing procedure. The e-finger is addressed by a smartphone-based miniature potentiostat and allows on-the-spot self-checking of the quality and safety of alcoholic spirits, via a single calibration-free voltammetric measurement, readily performed even by untrained end users. The e-finger is a new powerful screening tool in the hands of supervisory authorities to conduct on-site forensic investigations. More importantly, it paves the way toward in-house e-production of "ready-to-use" reliable self-testing devices.


Assuntos
Estupro , Dispositivos Eletrônicos Vestíveis , Dedos , Flunitrazepam , Autoteste
15.
Anal Chim Acta ; 1186: 339114, 2021 Nov 22.
Artigo em Inglês | MEDLINE | ID: mdl-34756268

RESUMO

The low-cost e-fabrication of specialized multianalyte biosensors within the point-of-care (POC) settings in a few minutes remains a great challenge. Unlike prefabricated biosensors, 3D printing seems to be able to meet this challenge, empowering the end user with the freedom to create on-demand devices adapted to immediate bioanalytical need. Here, we describe a novel miniature all-3D-printed 4-electrode biochip, capable of the simultaneous determination of different biomarkers in a single assay. The chip is utterly fabricated via an one-step 3D printing process and it is connected to a mini portable bi-potentiostant, permitting simultaneous measurements. The bioanalytical capability of the microchip is demonstrated through the simultaneous amperometric determination of two cardiac biomarkers (cholesterol and choline) in the same blood droplet, via enzymatic assays developed on its two tiny integrated electrodes. The simultaneous determination of cholesterol and choline is free from cross-talk phenomena and interferences offering limits of detection much lower than the cut-off levels of these biomarkers in blood for coronary syndromes. The biodevice is an easy-constructed, low-cost, sensitive and e-transferable POC chip with wide scope of applicability to other enzymatic bioassays.


Assuntos
Técnicas Biossensoriais , Colina , Técnicas Eletroquímicas , Eletrodos , Sistemas Automatizados de Assistência Junto ao Leito , Impressão Tridimensional
16.
Sensors (Basel) ; 21(20)2021 Oct 18.
Artigo em Inglês | MEDLINE | ID: mdl-34696121

RESUMO

This work reports the fabrication of integrated electrochemical fluidic paper-based analytical devices (ePADs) using a marker pen drawing and screen-printing. Electrodes were deposited on paper using screen-printing with conductive carbon ink. Then, the desired fluidic patterns were formed on the paper substrate by drawing with a commercial hydrophobic marker pen using an inexpensive computer-controlled x-y plotter. The working electrode was characterized by cyclic voltammetry and scanning electron microscopy. The analytical utility of the electrochemical PADs is demonstrated through electrochemical determination of Pb(II) and Cd(II) by anodic stripping voltammetry. For this purpose, the sample was mixed with a buffer solution and a Bi(III) solution, applied to the test zone of the PAD, the metals were preconcentrated as a bismuth alloy on the electrode surface and oxidized by applying an anodic potential scan. The proposed manufacturing approach enables the large-scale fabrication of fit-for-purpose disposable PADs at low cost which can be used for rapid on-site environmental monitoring.


Assuntos
Cádmio , Chumbo , Bismuto , Carbono , Eletrodos
17.
Sensors (Basel) ; 21(14)2021 Jul 12.
Artigo em Inglês | MEDLINE | ID: mdl-34300495

RESUMO

In this work, we developed a novel all-3D-printed device for the simple determination of quetiapine fumarate (QF) via voltammetric mode. The device was printed through a one-step process by a dual-extruder 3D printer and it features three thermoplastic electrodes (printed from a carbon black-loaded polylactic acid (PLA)) and an electrode holder printed from a non-conductive PLA filament. The integrated 3D-printed device can be printed on-field and it qualifies as a ready-to-use sensor, since it does not require any post-treatment (i.e., modification or activation) before use. The electrochemical parameters, which affect the performance of the sensor in QF determination, were optimized and, under the selected conditions, the quantification of QF was carried out in the concentration range of 5 × 10-7-80 × 10-7 mol × L-1. The limit of detection was 2 × 10-9 mol × L-1, which is lower than that of existing electrochemical QF sensors. The within-device and between-device reproducibility was 4.3% and 6.2% (at 50 × 10-7 mol × L-1 QF level), respectively, demonstrating the satisfactory operational and fabrication reproducibility of the device. Finally, the device was successfully applied for the determination of QF in pharmaceutical tablets and in human urine, justifying its suitability for routine and on-site analysis.


Assuntos
Antipsicóticos , Eletrodos , Eletrônica , Humanos , Impressão Tridimensional , Fumarato de Quetiapina , Reprodutibilidade dos Testes
18.
Anal Chim Acta ; 1159: 338426, 2021 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-33867040

RESUMO

In this paper, a 3D-printed microfluidic device is described which is suitable for sequential injection/anodic stripping voltammetric (SIA-ASV) determination of Pb(II) and Cd(II). The fluidic device is manufactured by 3D-printing in a single-step using a dual extruder 3D printer. The device is composed of a microfluidic cell (printed from a non-conductive polylactic acid (PLA) filament) and of 3 electrodes (printed from a conductive carbon-loaded PLA filament) which are integrated within the fluidic cell. During the preconcentration step, a zone of the sample (containing the target cations) and a zone of Bi(III) solution are mixed on-line and the cations are reduced on the working electrode forming a bismuth alloy. The detection step involves a voltametric scan in static solution, in which the accumulated metals are oxidized while the oxidation current is monitored. After the optimization of the relevant parameters, the limit of detection is 0.38 µg L-1 for Pb(II) and 0.57 µg L-1 for Cd(II), while the within-device repeatability and the between-device reproducibility are lower than 4.5% (n = 8) and 9% (n = 6), respectively, for both cations at the 30 µg L-1 level. The device was successfully applied to the simultaneous determination of Pb(II) and Cd(II) in a honey sample.

19.
Anal Chem ; 93(7): 3331-3336, 2021 02 23.
Artigo em Inglês | MEDLINE | ID: mdl-33560824

RESUMO

Nowadays, there is increased demand for wearable sensors for sweat glucose monitoring in order to facilitate diabetes management in a patient-friendly and noninvasive manner. This work describes a wearable glucose monitoring device in the form of an electrochemical ring (e-ring) fabricated by 3D printing. The 3D-printed e-ring consists of three carbon-based plastic electrodes (fabricated using a conductive filament) integrated at the inner side of a ring-shaped flexible plastic holder (fabricated using a nonconductive filament). The e-ring is modified with an electrodeposited gold film and is coupled to a miniature potentiostat directly addressable by a smartphone, offering the possibility for nonenzymatic amperometric self-testing of glucose levels in human sweat. Optical and electrochemical techniques are employed for the characterization of the e-ring. The device is resistant to mechanical bending and enables noninvasive glucose detection in sweat in the physiologically relevant concentration range of 12.5-400 µmol L-1 without interference from common electroactive metabolites. The 3D-printed e-ring bridges the gap between the existing fabrication/sensing technologies and the desired operational features for glucose self-monitoring and may be employed as a paradigm of in-house fabricated wearable sensors.


Assuntos
Técnicas Biossensoriais , Dispositivos Eletrônicos Vestíveis , Glicemia , Automonitorização da Glicemia , Técnicas Eletroquímicas , Glucose , Humanos , Impressão Tridimensional , Smartphone , Suor
20.
Sensors (Basel) ; 20(18)2020 Sep 11.
Artigo em Inglês | MEDLINE | ID: mdl-32933037

RESUMO

Flunitrazepam is an extremely potent benzodiazepine sedative which is associated with "drug-facilitated sexual assault" when administered within an alcoholic drink. This work describes a simple electrochemical method for on-site rapid detection of flunitrazepam in untreated spirits (whiskey, vodka and gin) using a single-use screen-printed sensor (featuring graphite working and auxiliary electrodes and an Ag/AgCl reference electrode) in a dry reagent format. Analysis was performed by placing a drop of sample on the sensor, which was previously coated with dry KCl, and recording selected reduction/oxidation peaks of the target compound in a cyclic voltammetry scan. The limit of quantification of flunitrazepam was at the sub-mg L-1 range. The between-sensor % relative standard deviation of the analytically useful reduction peak in a solution containing 11.4 mg L-1 flunitrazepam was 9.8% (n = 5). Quantification was performed using calibration curves constructed from pooled samples spiked with flunitrazepam with relative errors <15%. The main advantages of the methodology are that it involves no sample pretreatment (such as deoxygenation, extraction or reagent(s) addition) and requires only drop-sized volumes of the sample, thus facilitating rapid on-site screening using portable equipment.


Assuntos
Flunitrazepam , Preparações Farmacêuticas , Técnicas Eletroquímicas , Eletrodos , Indicadores e Reagentes , Estupro
SELEÇÃO DE REFERÊNCIAS