Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 176
Filtrar
1.
J Clin Med ; 13(17)2024 Aug 25.
Artigo em Inglês | MEDLINE | ID: mdl-39274253

RESUMO

Lipid lowering, with the use of statins after an acute coronary syndrome (ACS), is a cornerstone, well-established strategy for the secondary prevention of ischemic events in this high-risk cohort. In addition to the positive effect on lipid levels, statins have also been linked to improved atherosclerotic plaque characteristics, such as plaque regression and inflammation reduction, associated with the extent of reduction in LDL-C. The recent emergence of PCSK9 inhibitors for the management of dyslipidemia and the more extensive lipid lowering provided by these agents may provide better prevention for ACS patients when initiated after the ACS event. Several trials have evaluated the immediate post-ACS initiation of PCSK9 inhibitors, which has shown, to date, beneficial results. Furthermore, PCSK9 inhibitors have been linked with positive plaque remodeling and associated mortality benefits, which makes their use in the initial management strategy of such patients appealing. Therefore, in this review, we will analyze the rationale behind immediate lipid lowering after an ACS, report the evidence of PCSK9 inhibition immediately after the ACS event and the available data on plaque stabilization, and discuss treatment algorithms and clinical perspectives for the use of these agents in this clinical setting.

2.
J Hum Hypertens ; 38(10): 676-686, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-39317753

RESUMO

Pulse wave velocity (PWV) is as a reliable marker of arterial stiffness and vascular aging, surpassing traditional risk factors in predicting detrimental cardiovascular events. The present meta-analysis aims to investigate PWV thresholds and assess its prognostic value in outcomes of acute ischemic stroke (AIS). A search was conducted in PubMed, Cochrane, Web of Science, and Scopus for studies published up to January 2024, focusing on patients admitted with AIS, wherein arterial stiffness was assessed through PWV measurements during hospitalization. Identified studies reported PWV values in individuals with both favorable and unfavorable outcomes at the end of follow-up. Initially, 35 eligible studies provided data for weighted mean baPWV (11,953 AIS patients) and cfPWV (2,197 AIS patients) calculations. The average age was 67 years, with approximately 60% male, 67% hypertensive, 30% diabetic and 30% smoker participants. The weighted mean systolic blood pressure was approximately 150 mmHg. In AIS patients, the mean PWV was 10 m/s for standard cfPWV and 20 m/s for baPWV. Nine cohort studies (6,006 AIS patients) were included in the quantitative analysis of clinical outcomes. Higher PWV levels were associated with poorer functional outcomes (2.3 m/s higher, 95%CI:1.2-3.4, p < 0.001; I2 = 87.4%). AIS patients with arterial stiffness/vascular aging (higher PWV) had approximately 46.2% increased risk of poor functional outcome, 12.7% higher risk of mortality, 13.9% greater risk of major adverse cardiovascular events, and 13.9% greater risk of stroke recurrence over the long term compared to those without arterial stiffness. Advanced vascular aging, as indicated by PWV, significantly predicts adverse outcomes in AIS patients. Integrating the assessment of vascular aging into clinical practice can improve risk perception in these patients.


Assuntos
AVC Isquêmico , Análise de Onda de Pulso , Rigidez Vascular , Humanos , AVC Isquêmico/fisiopatologia , AVC Isquêmico/mortalidade , AVC Isquêmico/diagnóstico , Idoso , Masculino , Feminino , Prognóstico , Fatores de Risco , Envelhecimento/fisiologia , Pessoa de Meia-Idade , Medição de Risco
3.
Blood Press Monit ; 29(4): 212-216, 2024 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-38946333

RESUMO

OBJECTIVE: A novel automated auscultatory upper arm cuff blood pressure (BP) monitor KOROT V2 Doctor (InBody BPBIO280KV) was developed for professional use. An electronic stethoscope embedded in the device cuff records the Korotkoff sounds, which are graphically displayed during deflation allowing visual evaluation by the healthcare professional. The device provides automated measurements of BP and this study evaluated its accuracy. METHODS: The requirements of the Association for the Advancement of Medical Instrumentation/European Society of Hypertension/International Organization for Standardization (AAMI/ESH/ISO) Universal Standard (ISO 81060-2:2018) and its Amendment 1.2020-01 were applied. Participants were recruited to fulfill the age, sex, BP, arm circumference, and cuff distribution criteria of the Universal Standard and its Amendment in a general population using the same arm sequential measurement method. Three cuffs of the test device were tested for arm circumference 23-28, 28-35, and 33-42 cm. RESULTS: Data from 85 individuals were analyzed [mean age: 56.4 ±â€…16.0 (SD) years, 50 men, arm circumference 23-42 cm]. For validation Criterion 1, the mean difference ±SD between the test device and reference BP readings (N = 255) was -1.3 ± 6.0/1.5 ± 5.0 mmHg (systolic/diastolic; threshold ≤5 ±â€…8 mmHg). For Criterion 2, the SD of the averaged BP differences per individual (N = 85) was 4.61/3.48 mmHg (systolic/diastolic; threshold ≤6.82/6.78 mmHg). CONCLUSION: The KOROT V2 Doctor (InBody BPBIO280KV) device for professional use, which provides automated auscultatory measurements with visual display of the Korotkoff sounds, comfortably fulfills all the requirements of the AAMI/ESH/ISO Universal Standard (ISO 81060-2:2018) in a general population and can be recommended for clinical use.


Assuntos
Auscultação , Determinação da Pressão Arterial , Monitores de Pressão Arterial , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Adulto , Determinação da Pressão Arterial/instrumentação , Monitores de Pressão Arterial/normas , Auscultação/instrumentação , Braço , Pressão Sanguínea
4.
Hellenic J Cardiol ; 2024 May 31.
Artigo em Inglês | MEDLINE | ID: mdl-38823778

RESUMO

OBJECTIVE: The COVID-19 pandemic had an adverse impact on several cardiovascular risk factors. This study investigated the prevalence, awareness and treatment of hypertension in Greece before and after the pandemic. Data were collected in the context of the May Measurement Month (MMM) global survey initiated by the International Society of Hypertension. METHODS: Adult volunteers (age ≥ 18 years) were recruited through opportunistic screening in public areas across cities in Greece in 2019 and 2022. Medical history and triplicate sitting blood pressure (BP) measurements were taken using validated automated upper-arm cuff devices. The data were uploaded to the international MMM cloud platform. Hypertension was defined as systolic BP ≥ 140 mm Hg and/or diastolic ≥90 mm Hg and/or self-reported use of drugs for hypertension. The same threshold was used to define uncontrolled BP in treated individuals. RESULTS: Data from 12,080 adults were collected (5,727/6,353 in MMM 2019/2022; men 46/49%, p < 0.01; mean age 52.7 ± 16.6/54.8 ± 16.2, p < 0.001; smokers, 24.7/30.5, p < 0.001; diabetics 12/11.5%, p = NS; cardiovascular disease 5/5.8%, p = NS). The prevalence of hypertension was 41.6/42.6% (MMM 2019/2022, p = NS), with 21.3/27.5% of individuals with hypertension being unaware of their condition (p < 0.001), 5.6/2.4% aware untreated (p < 0.001), 24.8/22.1% treated uncontrolled (p < 0.05), and 48.3/47.8% treated controlled (p = NS). CONCLUSION: In Greece, the COVID-19 pandemic did not appear to affect the prevalence and control of hypertension; however, the rate of undiagnosed hypertension was higher after the pandemic. National strategies need to be implemented for the early detection and optimal management of hypertension in the general population in Greece.

5.
J Hypertens ; 42(8): 1350-1357, 2024 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-38690937

RESUMO

OBJECTIVES: Blood pressure (BP) variability (BPV) can be assessed using office (OBP), home (HBP), or ambulatory BP (ABP) measurements. This analysis investigated the association and agreement between OBP, HBP, and ABP measurements for BPV assessment at baseline and 10 weeks after initiating antihypertensive drug therapy. METHODS: Untreated hypertensive patients with elevated BPV were randomized to receive an angiotensin-converting enzyme inhibitor (ramipril) or a calcium channel blocker (nifedipine GITS) in a 10-week, open-label, blinded-end point study. BPV was assessed using standard deviation (SD) and coefficient of variation (CV) (reading-to-reading analyses). RESULTS: Data from 146 participants from three research centers (Athens/Greece; Milan/Italy; Shanghai/China) were analyzed [mean age 53 ±â€Š10 (SD) years, male individuals 60%, baseline systolic OBP, HBP, and 24 h ABP 144 ±â€Š9, 138 ±â€Š10, and 143 ±â€Š10 mmHg, respectively]. Post-treatment minus pre-treatment systolic CV difference was: OBP: 0.3%, P  = 0.28; HBP: -0.2%, P  = 0.20; 24 h ABP: 1.1%, P  < 0.001. Home and ambulatory (not office) BPV indices presented weak-to-moderate correlation, both before and during treatment (range of coefficients 0.04-0.33). The correlation coefficient between systolic HBP and awake ABP CV was 0.21 and 0.28 before and during treatment, respectively ( P  < 0.05/< 0.001, respectively). Home and ambulatory (not office) BPV indices presented slight-to-fair agreement (range 64-73%) in detecting participants with high systolic BPV (top quartile of respective distributions) both before and during treatment (kappa range 0.04-0.27). CONCLUSION: These data showed a weak-to-moderate association between out-of-office (but not office) BPV indices both before and during BP-lowering treatment, with reasonable agreement in detecting individuals with high BPV. Out-of-office BP measurements provide more similar and consistent BPV information than office measurements.


Assuntos
Anti-Hipertensivos , Monitorização Ambulatorial da Pressão Arterial , Pressão Sanguínea , Hipertensão , Humanos , Masculino , Pessoa de Meia-Idade , Anti-Hipertensivos/uso terapêutico , Feminino , Pressão Sanguínea/efeitos dos fármacos , Hipertensão/tratamento farmacológico , Hipertensão/fisiopatologia , Monitorização Ambulatorial da Pressão Arterial/métodos , Adulto , Ramipril/uso terapêutico , Idoso , Inibidores da Enzima Conversora de Angiotensina/uso terapêutico , Nifedipino/uso terapêutico
6.
J Hypertens ; 42(9): 1538-1543, 2024 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-38690918

RESUMO

OBJECTIVE: A novel automated auscultatory upper-arm cuff blood pressure (BP) monitor for office use (KOROT P3 Accurate, previously InBody BPBIO480KV), which displays Korotkoff sound curves for each BP reading was recently developed. This study investigated whether the review of Korotkoff sound curves by healthcare professionals further improves the accuracy of the device by identifying unreliable BP readings. METHODS: Three observers assessed independently the morphology of Korotkoff sound curves of BP measurements obtained during an ISO 81060-2:2018 validation study, and classified them as of good, fair, or poor quality (low amplitude or sound intensity, aberrant morphology, background noise, signal artifact, auscultatory gap, irregular rhythm). The observers were blinded to the study BP measurements. RESULTS: Korotkoff sound curves of 255 BP readings obtained in 85 individuals were analyzed (mean age 57.3 ±â€Š15.0 years, 53 men). Of the SBP readings 80.4/12.2/7.4% were classified as good/fair/poor, and DBP 76.9/12.2/10.9%. Inter-observer agreement in detecting poor-quality curves was 84.7/83.1% (systolic/diastolic). Of poor-quality curves, 10.5/60.7% (systolic/diastolic) clustered in the same individuals. The validation criterion 1 [mean test-reference BP difference ≤5 ±â€Š8 (SD) mmHg] was satisfied for readings with good (0.1 ±â€Š4.9/0.3 ±â€Š3.8 mmHg, systolic/diastolic) and fair-quality curves (-0.4 ±â€Š6.4/0.2 ±â€Š5.0), but not for poor-quality ones (2.7 ±â€Š8.8/3.6 ±â€Š8.1). By excluding poor-quality readings (40 of 255), criterion 1 of the validation study was improved (0.2 ±â€Š4.9/0.2 ±â€Š3.9 versus 0.3 ±â€Š5.5/0.6 ±â€Š4.7 mmHg). CONCLUSION: The visual assessment of Korotkoff sounds generated during automated auscultatory BP measurement by the KOROT P3 Accurate professional monitor identifies unreliable readings and further improves the device accuracy.


Assuntos
Auscultação , Determinação da Pressão Arterial , Humanos , Masculino , Pessoa de Meia-Idade , Feminino , Determinação da Pressão Arterial/métodos , Determinação da Pressão Arterial/instrumentação , Adulto , Auscultação/métodos , Idoso , Pressão Sanguínea/fisiologia , Monitores de Pressão Arterial , Reprodutibilidade dos Testes
7.
Diabetes Metab Syndr ; 18(5): 103042, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38781718

RESUMO

AIMS: The clinical utility of waist-to-height ratio (WHtR) in predicting cardiometabolic risk factors (CMRFs) and subclinical markers of cardiovascular disease remains controversial. We aimed to compare the utility of WHtR with waist circumference (WC) and body mass index (BMI) in identifying children and adolescents (youths) at risk for cardiometabolic outcomes, including clustered CMRFs, high carotid intima-media thickness (cIMT), and arterial stiffness (assessed as high pulse wave velocity, PWV). METHODS: We analyzed data from 34,224 youths (51.0 % boys, aged 6-18 years) with CMRFs, 5004 (49.5 % boys, aged 6-18 years) with cIMT measurement, and 3100 (56.4 % boys, aged 6-17 years) with PWV measurement from 20 pediatric samples across 14 countries. RESULTS: WHtR, WC, and BMI z-scores had similar performance in discriminating youths with ≥3 CMRFs, with the area under the curve (AUC) (95 % confidence interval, CI)) ranging from 0.77 (0.75-0.78) to 0.78 (0.76-0.80) using the modified National Cholesterol Education Program (NCEP) definition, and from 0.77 (0.74-0.79) to 0.77 (0.74-0.80) using the International Diabetes Federation (IDF) definition. Similarly, all three measures showed similar performance in discriminating youths with subclinical vascular outcomes, with AUC (95 % CI) ranging from 0.67 (0.64-0.71) to 0.70 (0.66-0.73) for high cIMT (≥P95 values) and from 0.60 (0.58-0.66) to 0.62 (0.58-0.66) for high PWV (≥P95 values). CONCLUSIONS: Our findings suggest that WHtR, WC, and BMI are equally effective in identifying at-risk youths across diverse pediatric populations worldwide. Given its simplicity and ease of use, WHtR could be a preferable option for quickly screening youths with increased cardiometabolic risk in clinical settings.


Assuntos
Índice de Massa Corporal , Fatores de Risco Cardiometabólico , Doenças Cardiovasculares , Circunferência da Cintura , Razão Cintura-Estatura , Humanos , Adolescente , Masculino , Criança , Feminino , Doenças Cardiovasculares/etiologia , Doenças Cardiovasculares/diagnóstico , Doenças Cardiovasculares/epidemiologia , Espessura Intima-Media Carotídea , Prognóstico , Seguimentos , Análise de Onda de Pulso , Fenótipo , Rigidez Vascular , Fatores de Risco
8.
BMC Med ; 22(1): 190, 2024 May 07.
Artigo em Inglês | MEDLINE | ID: mdl-38715060

RESUMO

Metabolic syndrome (MetS) is becoming prevalent in the pediatric population. The existing pediatric MetS definitions (e.g., the International Diabetes Federation (IDF) definition and the modified National Cholesterol Education Program (NCEP) definition) involve complex cut-offs, precluding fast risk assessment in clinical practice.We proposed a simplified definition for assessing MetS risk in youths aged 6-17 years, and compared its performance with two existing widely used pediatric definitions (the IDF definition, and the NCEP definition) in 10 pediatric populations from 9 countries globally (n = 19,426) using the receiver operating characteristic (ROC) curve analyses. In general, the total MetS prevalence of 6.2% based on the simplified definition was roughly halfway between that of 4.2% and 7.7% estimated from the IDF and NCEP definitions, respectively. The ROC curve analyses showed a good agreement between the simplified definition and two existing definitions: the total area under the curve (95% confidence interval) of the proposed simplified definition for identifying MetS risk achieved 0.91 (0.89-0.92) and 0.79 (0.78-0.81) when using the IDF or NCEP definition as the gold standard, respectively.The proposed simplified definition may be useful for pediatricians to quickly identify MetS risk and cardiometabolic risk factors (CMRFs) clustering in clinical practice, and allow direct comparison of pediatric MetS prevalence across different populations, facilitating consistent pediatric MetS risk monitoring and the development of evidence-based pediatric MetS prevention strategies globally.


Assuntos
Síndrome Metabólica , Humanos , Síndrome Metabólica/epidemiologia , Síndrome Metabólica/diagnóstico , Adolescente , Criança , Masculino , Feminino , Prevalência , Curva ROC , Saúde Global , Medição de Risco/métodos , Fatores de Risco
10.
J Hypertens ; 42(6): 939-947, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38647124

RESUMO

Recent evidence suggests that an exaggerated blood pressure (BP) response to standing (ERTS) is associated with an increased risk of adverse outcomes, both in young and old individuals. In addition, ERTS has been shown to be an independent predictor of masked hypertension. In the vast majority of studies reporting on the prognostic value of orthostatic hypertension (OHT), the definition was based only on systolic office BP measurements. This consensus statement provides recommendations on the assessment and management of individuals with ERTS and/or OHT. ERTS is defined as an orthostatic increase in SBP at least 20 mmHg and OHT as an ERTS with standing SBP at least 140 mmHg. This statement recommends a standardized methodology to assess ERTS, by considering body and arm position, and the number and timing of BP measurements. ERTS/OHT should be confirmed in a second visit, to account for its limited reproducibility. The second assessment should evaluate BP changes from the supine to the standing posture. Ambulatory BP monitoring is recommended in most individuals with ERTS/OHT, especially if they have high-normal seated office BP. Implementation of lifestyle changes and close follow-up are recommended in individuals with ERTS/OHT and normotensive seated office BP. Whether antihypertensive treatment should be administered in the latter is unknown. Hypertensive patients with ERTS/OHT should be managed as any other hypertensive patient. Standardized standing BP measurement should be implemented in future epidemiological and interventional studies.


Assuntos
Pressão Sanguínea , Hipertensão , Humanos , Hipertensão/fisiopatologia , Hipertensão/diagnóstico , Hipertensão/terapia , Pressão Sanguínea/fisiologia , Determinação da Pressão Arterial/métodos , Consenso , Posição Ortostática , Europa (Continente) , Monitorização Ambulatorial da Pressão Arterial/métodos
11.
Hypertension ; 81(7): 1477-1488, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38602099

RESUMO

BACKGROUND: Atrial fibrillation (AF) is often asymptomatic and undiagnosed. As AF and hypertension often coexist, opportunistic AF detection during routine automated blood pressure (BP) measurement appears to be an attractive screening method. METHODS: A systematic literature search was conducted to identify studies assessing the diagnostic test accuracy of office, home, or 24-hour ambulatory BP measuring devices with AF detection algorithms versus reference electrocardiography. Analyses were performed per participant (AF status based on several BP readings; most office/home devices) or per reading (AF status based on individual readings; all ambulatory devices). A meta-analysis stratified by device type (office/home/ambulatory) was conducted to calculate pooled measures of diagnostic accuracy. Sensitivity/meta-regression analyses were also performed. RESULTS: Among 3096 records initially retrieved, 23 diagnostic test accuracy studies were included. Data derived from 11 093 individuals (weighted age 69 years, males 56%, hypertensives 79%, diabetics 24%, and AF prevalence 17%) indicated a pooled sensitivity 0.97 (95% CI, 0.92-0.99), specificity 0.93 (95% CI, 0.90-0.95), and accuracy 0.93 (95% CI, 0.89-0.95), with generally consistent results using office, home, or ambulatory BP devices (slightly lower specificity with the latter). The positive and negative predictive values were 0.70 (95% CI, 0.60-0.80) and 0.99 (95% CI, 0.98-1.00), respectively. Sensitivity analyses indicated lower specificity in studies implementing reading versus participant analyses. Most studies presented a low risk of bias and minor applicability concerns. CONCLUSIONS: There is considerable and consistent evidence suggesting high diagnostic accuracy of AF detection algorithms implemented in automated BP monitors during routine BP measurements in and out of the office. AF diagnosis requires verification (electrocardiography) before treatment is administered.


Assuntos
Fibrilação Atrial , Monitorização Ambulatorial da Pressão Arterial , Hipertensão , Programas de Rastreamento , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Monitorização Ambulatorial da Pressão Arterial/métodos , Hipertensão/diagnóstico , Hipertensão/fisiopatologia , Hipertensão/epidemiologia , Programas de Rastreamento/métodos , Determinação da Pressão Arterial/métodos , Determinação da Pressão Arterial/estatística & dados numéricos , Sensibilidade e Especificidade , Algoritmos , Visita a Consultório Médico/estatística & dados numéricos , Feminino , Masculino , Eletrocardiografia/métodos
12.
J Clin Med ; 13(6)2024 Mar 18.
Artigo em Inglês | MEDLINE | ID: mdl-38541976

RESUMO

Background: Telemedicine is increasingly used in several fields of healthcare, including vascular medicine. This study aimed to investigate the views of experts and propose clinical practice recommendations on the possible applications of telemedicine in vascular medicine. Methods: A clinical guidance group proposed a set of 67 clinical practice recommendations based on the synthesis of current evidence and expert opinion. The Telemedicine Vascular Medicine Working Group included 32 experts from Europe evaluating the appropriateness of each clinical practice recommendation based on published RAND/UCLA methodology in two rounds. Results: In the first round, 60.9% of clinical practice recommendations were rated as appropriate, 35.9% as uncertain, and 3.1% as inappropriate. The strongest agreement (a median value of 10) was reached on statements regarding the usefulness of telemedicine during the 2019 coronavirus disease (COVID-19) pandemic, its usefulness for geographical areas that are difficult to access, and the superiority of video calls compared to phone calls only. The lowest degree of agreement (a median value of 2) was reported on statements regarding the utility of telemedicine being limited to the COVID-19 pandemic and regarding the applicability of teleconsultation in the diagnosis and management of abdominal aortic aneurysm. In the second round, 11 statements were re-evaluated to reduce variability. Conclusions: This study highlights the levels of agreement and the points that raise concern on the use of telemedicine in vascular medicine. It emphasizes the need for further clarification on various issues, including infrastructure, logistics, and legislation.

13.
Medicina (Kaunas) ; 60(2)2024 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-38399618

RESUMO

Background and Objectives: The success of combined antiretroviral therapy (cART) has led to a dramatic improvement in the life expectancy of people living with HIV (PLWH). However, there has been an observed increase in cardiometabolic, bone, renal, hepatic, and neurocognitive manifestations, as well as neoplasms, known as serious non-AIDS events/SNAEs, compared to the general population of corresponding age. This increase is linked to a harmful phenomenon called inflammaging/immunosenescence, which is driven by chronic immune activation and intestinal bacterial translocation. In this study, we examined immunological and metabolic parameters in individuals receiving current cART. Materials and Methods: The study was conducted at Laiko General Hospital in Athens, Greece. Plasma concentrations of sCD14, IL-6, SuPAR, I-FABP, and LBP were measured in virally suppressed PLWH under cART with at least 350 CD4 lymphocytes/µL. We compared these levels between PLWH receiving integrase strand transfer inhibitors (INSTIs) and protease inhibitors (PIs) and attempted to correlate them with chronic immune activation and metabolic parameters. Results: Data from 28 PLWH were analyzed, with a mean age of 52 and 93% being males. Among the two comparison groups, IL-6 levels were higher in the PIs group (5.65 vs. 7.11 pg/mL, p = 0.03). No statistically significant differences were found in the other measured parameters. A greater proportion of PLWH under INSTIs had normal-range LBP (33% vs. 0%, p = 0.04). When using inverse probability of treatment weighting, no statistically significant differences in the measured parameters were found between the two groups (sCD14 p = 0.511, IL-6 p = 0.383, SuPAR p = 0.793, I-FABP p = 0.868, and LBP p = 0.663). Glucose levels were found to increase after viral suppression in the entire sample (92 mg/dL vs. 98 mg/dL, p = 0.009). Total (191 mg/dL vs. 222 mg/dL, p = 0.005) and LDL cholesterol (104 mg/dL vs. 140 mg/dL, p = 0.002) levels were higher in the PIs group. No significant differences were observed in liver and renal function tests. Conclusions: Further investigation is warranted for PLWH on cART-containing INSTI regimens to explore potential reductions in chronic immune activation and intestinal bacterial translocation.


Assuntos
Infecções por HIV , Inibidores de Proteases , Humanos , Masculino , Pessoa de Meia-Idade , Feminino , Receptores de Ativador de Plasminogênio Tipo Uroquinase , Interleucina-6 , Receptores de Lipopolissacarídeos , Infecções por HIV/complicações , Infecções por HIV/tratamento farmacológico , Integrases , Peptídeo Hidrolases
14.
J Hypertens ; 42(3): 385-392, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38164947

RESUMO

OBJECTIVES: Ambulatory (ABP) and self-home blood pressure (HBP) measurements are known to be superior to office blood pressure (OBP) measurements in predicting cardiovascular events. Whether ABP has superior prognostic ability than HBP, or the reverse, has not been adequately investigated. METHODS: A systematic literature search was conducted to identify outcome studies investigating HBP and ABP in the same population. A meta-analysis was conducted to calculate the pooled measure of risk regarding the primary endpoint of each study for each method. Primary analysis included the comparison of pooled estimates of HBP versus 24 h ABP. RESULTS: Among 2587 articles retrieved, 6 fulfilled the inclusion criteria. Meta-analysis of five studies ( n  = 4439, weighted age 57 years, men 52%, hypertension 68%, diabetes 15%, cardiovascular disease 11%) indicated pooled hazard ratio per 10 mmHg increase in systolic HBP 1.36 (95% CI 1.23-1.50) and in 24 h ABP 1.38 (1.22-1.57) for the primary endpoint of each study ( z -test P  = NS). Meta-analysis of five studies ( n  = 4497, weighted age 58 years, men 51%, hypertension 65%, diabetes 15%, cardiovascular disease 9%) indicated pooled hazard ratio per 10 mmHg increase in systolic HBP 1.29 (1.14-1.47), daytime ABP 1.30 (1.15-1.46) and nighttime ABP 1.31 (1.14-1.50) ( z -test, P  = NS). Data for DBP were similar. All studies were deemed to have low risk of bias. In studies comparing all the three methods, OBP provided the lowest hazard ratio. CONCLUSION: This meta-analysis of the available prospective outcome studies suggested that HBP and ABP have similar ability in predicting outcome and superior to OBP.


Assuntos
Doenças Cardiovasculares , Diabetes Mellitus , Hipertensão , Masculino , Humanos , Pessoa de Meia-Idade , Monitorização Ambulatorial da Pressão Arterial , Determinação da Pressão Arterial/métodos , Doenças Cardiovasculares/diagnóstico , Prognóstico , Estudos Prospectivos , Hipertensão/diagnóstico , Pressão Sanguínea/fisiologia , Diabetes Mellitus/diagnóstico
16.
Cancers (Basel) ; 16(2)2024 Jan 20.
Artigo em Inglês | MEDLINE | ID: mdl-38275891

RESUMO

Cancer-associated thrombosis (CAT) is a common complication in lung cancer patients. Lung cancer confers an increased risk of thrombosis compared to other solid malignancies across all stages of the disease. Newer treatment agents, including checkpoint immunotherapy and targeted agents, may further increase the risk of CAT. Different risk-assessment models, such as the Khorana Risk Score, and newer approaches that incorporate genetic risk factors have been used in lung cancer patients to evaluate the risk of thrombosis. The management of CAT is based on the results of large prospective trials, which show similar benefits to low-molecular-weight heparins (LMWHs) and direct oral anticoagulants (DOACs) in ambulatory patients. The anticoagulation agent and duration of therapy should be personalized according to lung cancer stage and histology, the presence of driver mutations and use of antineoplastic therapy, including recent curative lung surgery, chemotherapy or immunotherapy. Treatment options should be evaluated in the context of the COVID-19 pandemic, which has been shown to impact the thrombotic risk in cancer patients. This review focuses on the epidemiology, pathophysiology, risk factors, novel predictive scores and management of CAT in patients with active lung cancer, with a focus on immune checkpoint inhibitors.

17.
Blood Press Monit ; 29(2): 89-92, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-37937605

RESUMO

OBJECTIVE: This study evaluated the accuracy of the automated oscillometric upper-arm cuff device AVITA BPM82 intended for home use in a general population according to the Association for the Advancement of Medical Instrumentation/European Society of Hypertension/International Organization for Standardization (AAMI/ESH/ISO) Universal Standard (ISO 81060-2:2018) and its Amendment 1.2020-01. METHODS: Participants were recruited to fulfill the age, sex, blood pressure (BP), and limb distribution criteria of the AAMI/ESH/ISO Universal Standard and its Amendment 1.2020-01 in a general population using the same arm sequential BP measurement method. Two cuffs of the test device were used for arm circumference 22-33 (medium) and 33-42 cm (large). RESULTS: One-hundred-one individuals were recruited and 85 were analyzed [mean age 57.3 ±â€…15.1 (SD) years, 46 men, arm circumference 32 ±â€…5.1 cm, range 22.3-42 cm]. For validation Criterion 1, the mean difference ±SD between the test device and reference BP readings (N = 255) was 1.3 ±â€…6.5/3.6 ±â€…5.9 mmHg (systolic/diastolic; threshold ≤5 ±â€…8 mmHg). For Criterion 2, the SD of the averaged BP differences between the test device and reference BP per individual (N = 85) was 5.70/5.25 mmHg (systolic/diastolic; threshold ≤6.82/5.89 mmHg). CONCLUSIONS: The automated oscillometric home BP monitor AVITA BPM82 comfortably fulfilled all the requirements of the AAMI/ESH/ISO Universal Standard (ISO 81060-2:2018) and its Amendment 1.2020-01 in a general population and can be recommended for clinical use.


Assuntos
Monitores de Pressão Arterial , Hipertensão , Masculino , Humanos , Adulto , Pessoa de Meia-Idade , Idoso , Pressão Sanguínea , Hipertensão/diagnóstico , Determinação da Pressão Arterial , Padrões de Referência
18.
Blood Press Monit ; 29(2): 99-102, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-37997431

RESUMO

OBJECTIVE: To evaluate the blood pressure (BP) measurement accuracy of the Braun BUA4000 automated oscillometric upper-arm cuff device for self-home use in a general population according to the Association for the Advancement of Medical Instrumentation/European Society of Hypertension/International Organization for Standardization (AAMI/ESH/ISO) Universal Standard (ISO 81060-2:2018) and its Amendment 1.2020-01. METHODS: Participants were recruited to fulfill the age, sex, BP and limb circumference distribution criteria of the AAMI/ESH/ISO Universal Standard in a general population using the same arm sequential BP measurement method. A single wide-range cuff of the test device was used for arm circumference range 22-42 cm. RESULTS: A total of 98 individuals were recruited and 85 were analyzed [mean age 60.3 ±â€…16.1 (SD) years, 44 men, arm circumference 31.5 ±â€…5.1 cm, range 22-41.5 cm]. For validation criterion 1, the mean difference ± SD between the test device and reference BP readings ( N  = 255) was 0.9 ±â€…6.4/-0.3 ±â€…6.4 mmHg (systolic/diastolic; threshold ≤5 ±â€…8 mmHg). For criterion 2, the SD of the averaged BP differences between the test device and reference BP per individual ( N  = 85) was 5.15/5.81 mmHg (systolic/diastolic; threshold ≤6.88/6.95 mmHg). CONCLUSION: The Braun BUA4000 automated oscillometric BP monitor fulfilled all the requirements of the AAMI/ESH/ISO Universal Standard in a general population and can be recommended for self-monitoring of BP by patients at home.


Assuntos
Monitores de Pressão Arterial , Hipertensão , Masculino , Humanos , Adulto , Pessoa de Meia-Idade , Idoso , Pressão Sanguínea , Hipertensão/diagnóstico , Determinação da Pressão Arterial , Padrões de Referência
20.
Hypertens Res ; 47(3): 790-793, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38123713

RESUMO

This study investigated the seasonal effect on blood pressure (BP) variability. Patients on stable antihypertensive drug treatment were assessed with office (OBP), home (HBP), and ambulatory BP (ABP) measurements in winter, next summer, and in next winter. Fifty-eight participants with full data for winter and summer were analyzed (mean age 65.2 ± 7.9 [SD], 64% males). OBP, HBP and ABP (24-h; daytime) were lower in summer than in winter (P < 0.01), whereas nighttime ABP was unchanged (p = NS). Standard deviation (SD), coefficient of variation (CV) and average real variability (ARV) for systolic OBP were higher in winter than summer (p < 0.01/ < 0.05/ < 0.01, respectively). These indices for HBP and ABP measurements did not differ in winter and summer (p = NS). Forty participants had complete data for winter-summer-next winter and HBP/ABP variability indices did not differ for both winters versus summer. These preliminary data suggest that BP variability is unaffected by seasonal changes in contrast to average BP levels.


Assuntos
Determinação da Pressão Arterial , Hipertensão , Masculino , Humanos , Pessoa de Meia-Idade , Idoso , Feminino , Pressão Sanguínea/fisiologia , Estações do Ano , Monitorização Ambulatorial da Pressão Arterial
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA