Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
Gen Hosp Psychiatry ; 85: 155-162, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37926051

RESUMO

OBJECTIVE: Alcohol remains the fourth­leading preventable cause of death in the U.S. The objective of this study was to compare the incidence of phenobarbital (PHB)-resistant withdrawal and determine risk factors for PHB-resistant alcohol withdrawal syndrome (AWS). METHODS: This retrospective cohort study included adults admitted to an academic center with AWS who received PHB as part of an institution-specific treatment protocol. The primary outcome was incidence of AWS resistant to initial protocolized PHB load across two cohorts (standard-dose, 10 mg/kg vs. low-dose, 6 mg/kg). RESULTS: Among 176 included patients, there was no difference in the incidence of PHB-resistant AWS based on initial PHB load [low-dose load, 21 (18.3%) vs. standard-dose load, 12 (19.7%), p = 0.82]. There were also no differences in observed PHB-related ADEs between the groups. Total benzodiazepine dose received (mg) in the 24 h prior to initial PHB load was the only risk factor significantly associated with AWS resistant to initial protocolized PHB load [adjusted OR 1.79 (95% CI 1.24, 2.60)]. PHB-resistant withdrawal occurred in 33 (18.8%) patients with a median cumulative PHB dose of approximately 20 mg/kg during hospitalization. CONCLUSION(S): There were no differences in the incidence of PHB-resistant AWS or PHB-related ADEs based on initial PHB loading dose.


Assuntos
Alcoolismo , Síndrome de Abstinência a Substâncias , Adulto , Humanos , Síndrome de Abstinência a Substâncias/epidemiologia , Síndrome de Abstinência a Substâncias/tratamento farmacológico , Estudos Retrospectivos , Benzodiazepinas/uso terapêutico , Fenobarbital/uso terapêutico
4.
BMJ Case Rep ; 13(8)2020 Aug 11.
Artigo em Inglês | MEDLINE | ID: mdl-32784244

RESUMO

A 36-year-old previously healthy woman with no personal or family history of mental illness presented with new-onset psychosis after a diagnosis of symptomatic COVID-19. Her psychotic symptoms initially improved with antipsychotics and benzodiazepines and further improved with resolution of COVID-19 symptoms. This is the first case of COVID-19-associated psychosis in a patient with no personal or family history of a severe mood or psychotic disorder presenting with symptomatic COVID-19, highlighting the need for vigilant monitoring of neuropsychiatric symptoms in these individuals.


Assuntos
Betacoronavirus , Infecções por Coronavirus/complicações , Infecções por Coronavirus/psicologia , Pneumonia Viral/complicações , Pneumonia Viral/psicologia , Transtornos Psicóticos/etiologia , Transtornos Psicóticos/psicologia , Adulto , Antipsicóticos/uso terapêutico , COVID-19 , Diagnóstico Diferencial , Feminino , Humanos , Pandemias , Transtornos Psicóticos/tratamento farmacológico , SARS-CoV-2
6.
Congenit Heart Dis ; 12(1): 67-73, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-27561699

RESUMO

BACKGROUND: Antenatal diagnosis of congenital heart defects (CHD) can impact outcomes in neonates with severe CHD. Obstetric screening guidelines and the indications for fetal echocardiography (FE) have evolved in an attempt to improve the early prenatal detection of CHD. Analyzing yield for specific indications will help clinicians better stratify at-risk pregnancies. METHODS: Retrospective cohort study of all FE performed between 2000 and 2010 at a single tertiary care academic medical center in New York City. A total of 9878 FE met inclusion criteria for our study. In cases of multiple gestations (MG), each fetus was counted as a separate study. RESULTS: The number of new diagnosis of fetal CHD by FEs increased 200%. There was a statistically significant increase in those referred for suspected CHD, increased nuchal translucency (NT), MG, and suboptimal imaging (P < .001). The indication of "suboptimal imaging" (SO) not only accounted for 5.23% of all referrals from 2000 to 2002, compared to 22.26% of all referrals from 2008 to 2010 (P < .0001), but also had the lowest yield for diagnoses of CHD (P < .02). CONCLUSIONS: Over the past decade, there has been an increase in utilization of FE with a proportional increase in prenatally diagnosed CHD. For indications such as suspected CHD, NT and MG increases in referrals have led to a proportionate increase in fetal diagnosis of CHD. SO as an indication has the lowest yield of fetal diagnosis of CHD. Antenatal detection of CHD may be improved by a change in obstetric imaging protocols to ensure appropriate referrals.


Assuntos
Ecocardiografia/estatística & dados numéricos , Coração Fetal/diagnóstico por imagem , Cardiopatias Congênitas/diagnóstico por imagem , Padrões de Prática Médica , Ultrassonografia Pré-Natal/estatística & dados numéricos , Ecocardiografia/tendências , Feminino , Humanos , Cidade de Nova Iorque , Padrões de Prática Médica/tendências , Valor Preditivo dos Testes , Gravidez , Prognóstico , Reprodutibilidade dos Testes , Estudos Retrospectivos , Centros de Atenção Terciária , Fatores de Tempo , Ultrassonografia Pré-Natal/métodos , Ultrassonografia Pré-Natal/tendências
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA