Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
J Breast Imaging ; 3(3): 354-362, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34056594

RESUMO

OBJECTIVE: To determine the impact of the COVID-19 pandemic on breast imaging education. METHODS: A 22-item survey addressing four themes during the early pandemic (time on service, structured education, clinical training, future plans) was emailed to Society of Breast Imaging members and members-in-training in July 2020. Responses were compared using McNemar's and Mann-Whitney U tests; a general linear model was used for multivariate analysis. RESULTS: Of 136 responses (136/2824, 4.8%), 96 U.S. responses from radiologists with trainees, residents, and fellows were included. Clinical exposure declined during the early pandemic, with almost no medical students on service (66/67, 99%) and fewer clinical days for residents (78/89, 88%) and fellows (48/68, 71%). Conferences shifted to remote live format (57/78, 73%), with some canceled (15/78, 19%). Compared to pre-pandemic, resident diagnostic (75/78, 96% vs 26/78, 33%) (P < 0.001) and procedural (73/78, 94% vs 21/78, 27%) (P < 0.001) participation fell, as did fellow diagnostic (60/61, 98% vs 47/61, 77%) (P = 0.001) and procedural (60/61, 98% vs 43/61, 70%) (P < 0.001) participation. Most thought that the pandemic negatively influenced resident and fellow screening (64/77, 83% and 43/60, 72%, respectively), diagnostic (66/77, 86% and 37/60, 62%), and procedural (71/77, 92% and 37/61, 61%) education. However, a majority thought that decreased time on service (36/67, 54%) and patient contact (46/79, 58%) would not change residents' pursuit of a breast imaging fellowship. CONCLUSION: The pandemic has had a largely negative impact on breast imaging education, with reduction in exposure to all aspects of breast imaging. However, this may not affect career decisions.

2.
J Breast Imaging ; 3(3): 343-353, 2021 May 21.
Artigo em Inglês | MEDLINE | ID: mdl-38424771

RESUMO

OBJECTIVE: To determine the early impact of the COVID-19 pandemic on breast imaging centers in California and Texas and compare regional differences. METHODS: An 11-item survey was emailed to American College of Radiology accredited breast imaging facilities in California and Texas in August 2020. A question subset addressed March-April government restrictions on elective services ("during the shutdown" and "after reopening"). Comparisons were made between states with chi-square and Fisher's tests, and timeframes with McNemar's and paired t-tests. RESULTS: There were 54 respondents (54/240, 23%, 26 California, 28 Texas). Imaging volumes fell during the shutdown and remained below pre-pandemic levels after reopening, with reduction in screening greatest (ultrasound 12% of baseline, mammography 13%, MRI 23%), followed by diagnostic MRI (43%), procedures (44%), and diagnostics (45%). California reported higher volumes during the shutdown (procedures, MRI) and after reopening (diagnostics, procedures, MRI) versus Texas (P = 0.001-0.02). Most screened patients (52/54, 96% symptoms and 42/54, 78% temperatures), and 100% (53/53) modified check-in and check-out. Reading rooms or physician work were altered for social distancing (31/54, 57%). Physician mask (45/48, 94%), gown (15/48, 31%), eyewear (22/48, 46%), and face shield (22/48, 46%) use during procedures increased after reopening versus pre-pandemic (P < 0.001-0.03). Physician (47/54, 87%) and staff (45/53, 85%) financial impacts were common, but none reported terminations. CONCLUSION: Breast imaging volumes during the early pandemic fell more severely in Texas than in California. Safety measures and financial impacts on physicians and staff were similar in both states.

3.
Clin Imaging ; 40(4): 591-3, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27317202

RESUMO

A 38year-old male presented with cauda equina syndrome following multiple lumbar puncture attempts. Lumbar spine magnetic resonance imaging (MRI) showed a subdural hematoma and an area of apparent contrast enhancement in the spinal canal on sagittal post-contrast images. Axial post-contrast images obtained seven minutes later demonstrated an increase in size and change in shape of the region of apparent contrast enhancement, indicating active extravasation of the contrast agent. This is the first reported case of active extravasation of gadolinium-based contrast agent in the spine.


Assuntos
Meios de Contraste/efeitos adversos , Extravasamento de Materiais Terapêuticos e Diagnósticos/diagnóstico por imagem , Gadolínio/administração & dosagem , Hematoma Subdural/etiologia , Punção Espinal/efeitos adversos , Espaço Subdural , Adulto , Cauda Equina/diagnóstico por imagem , Hematoma Subdural/diagnóstico por imagem , Humanos , Imageamento por Ressonância Magnética , Masculino , Espaço Subdural/diagnóstico por imagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA