1.
JACC Cardiovasc Interv ; 13(2): 210-216, 2020 01 27.
Artigo em Inglês | MEDLINE | ID: mdl-31883715

RESUMO

OBJECTIVES: The aim of this study was to report the 1-year results of transcatheter aortic valve replacement (TAVR) with the Edwards SAPIEN 3 (S3) valve in extremely large annuli. BACKGROUND: Favorable 30-day outcomes of S3 TAVR in annuli >683 mm2 have previously been reported. Pacemaker implantation rates were acceptable, and a larger left ventricular outflow tract and more eccentric annular anatomy were associated with increasing paravalvular leak. METHODS: From December 2013 to December 2018, 105 patients across 15 centers with mean area 721.3 ± 36.1 mm2 (range 683.5 to 852.0 mm2) underwent TAVR using an S3 device. Clinical, anatomic, and procedural characteristics were analyzed. One-year survival and echocardiographic follow-up were reached in 94.3% and 82.1% of patients, respectively. Valve Academic Research Consortium-2 30-day and 1-year outcomes were reported. RESULTS: The mean age was 76.9 ± 10.4 years, and Society of Thoracic Surgeons predicted risk score averaged 5.2 ± 3.4%. One-year overall mortality and stroke rates were 18.2% and 2.4%, respectively. Quality-of-life index improved from baseline to 30 days and at 1 year (p < 0.001 for both). Mild paravalvular aortic regurgitation occurred in 21.7% of patients, while moderate or greater paravalvular aortic regurgitation occurred in 4.3%. Mild and moderate or severe transvalvular aortic regurgitation occurred in 11.6% and 0%, respectively. Valve gradients remained stable at 1 year. CONCLUSIONS: S3 TAVR in annular areas >683 mm2 is feasible, with favorable mid-term outcomes.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Próteses Valvulares Cardíacas , Desenho de Prótese , Substituição da Valva Aórtica Transcateter/instrumentação , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Feminino , Hemodinâmica , Humanos , Masculino , América do Norte , Complicações Pós-Operatórias/mortalidade , Complicações Pós-Operatórias/terapia , Recuperação de Função Fisiológica , Estudos Retrospectivos , Fatores de Risco , Índice de Gravidade de Doença , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento
2.
JACC Cardiovasc Interv ; 11(14): 1377-1387, 2018 07 23.
Artigo em Inglês | MEDLINE | ID: mdl-29960755

RESUMO

OBJECTIVES: The aim of this study was to determine factors affecting paravalvular leak (PVL) in transcatheter aortic valve replacement (TAVR) with the Edwards SAPIEN 3 (S3) valve in extremely large annuli. BACKGROUND: The largest recommended annular area for the 29-mm S3 is 683 mm2. However, experience with S3 TAVR in annuli >683 mm2 has not been widely reported. METHODS: From December 2013 to July 2017, 74 patients across 16 centers with mean area 721 ± 38 mm2 (range: 684 to 852 mm2) underwent S3 TAVR. The transfemoral approach was used in 95%, and 39% were under conscious sedation. Patient, anatomic, and procedural characteristics were retrospectively analyzed. Valve Academic Research Consortium-2 outcomes were reported. RESULTS: Procedural success was 100%, with 2 deaths, 1 stroke, and 2 major vascular complications at 30 days. Post-dilatation occurred in 32%, with final balloon overfilling (1 to 5 ml extra) in 70% of patients. Implantation depth averaged 22.3 ± 12.4% at the noncoronary cusp and 20.7 ± 9.9% at the left coronary cusp. New left bundle branch block occurred in 17%, and 6.3% required new permanent pacemakers. Thirty-day echocardiography showed mild PVL in 22.3%, 6.9% moderate, and none severe. There was no annular rupture or coronary obstruction. Mild or greater PVL was associated with larger maximum annular and left ventricular outflow tract (LVOT) diameters, larger LVOT area and perimeter, LVOT area greater than annular area, and higher annular eccentricity. CONCLUSIONS: TAVR with the 29-mm S3 valve beyond the recommended range by overexpansion is safe, with acceptable PVL and pacemaker rates. Larger LVOTs and more eccentric annuli were associated with more PVL. Longer term follow-up will be needed to determine durability of S3 TAVR in this population.


Assuntos
Insuficiência da Valva Aórtica/etiologia , Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/instrumentação , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Feminino , Humanos , Masculino , Desenho de Prótese , Sistema de Registros , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Estados Unidos
3.
Circ J ; 75(5): 1120-9, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-21467655

RESUMO

BACKGROUND: The long-term impact of treating de novo coronary lesions in native vessels and challenging small vessel and long lesion subsets with TAXUS Liberté stents is unknown. This report examines the 3-year efficacy and safety from the TAXUS ATLAS program. METHODS AND RESULTS: TAXUS ATLAS WH, Small Vessel, and Long Lesion are non-randomized studies comparing TAXUS Liberté (n = 871), TAXUS Liberté 2.25 mm (n = 261), and TAXUS Liberté 38 mm (n = 150) stents, respectively, to case-matched TAXUS Express historical controls. TAXUS Liberté demonstrated comparable 3-year rates of major adverse cardiac events (19.0% vs. 20.2%, P = 0.51) in de novo lesions, reduced target lesion revascularization (TLR, 10.0% vs. 22.1%, P = 0.008) in small vessels, and reduced myocardial infarction (MI, 2.9% vs. 10.4%; P = 0.01) and stent thrombosis (ST, 0.0% vs. 3.9%, P = 0.03) in long lesions vs. TAXUS Express. After propensity score adjustment, no statistically significant effect of TAXUS Liberté on TLR (9.7% vs. 16.9%, P = 0.12) in small vessels or MI (2.9% vs. 7.9%, P = 0.05) in long lesions was noted, although reduced ST (0.0% vs. 2.7%, P = 0.02) remained in long lesions. Multivariate analyses demonstrated that TAXUS Liberté treatment significantly reduced TLR by 66% in small vessels, and MI by 75% in long lesions, vs. TAXUS Express. CONCLUSIONS: TAXUS Liberté suggests durable 3-year effectiveness in reducing restenosis and improved clinical outcomes in small vessels and long lesions compared with TAXUS Express.


Assuntos
Stents , Humanos , Taxus