Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 101
Filtrar
1.
Nanomedicine ; 59: 102750, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38734040

RESUMO

The human pathogenic fungus Candida albicans damages epithelial cells during superficial infections. Here we use three-dimensional-sequential-confocal Raman spectroscopic imaging and atomic force microscopy to investigate the interaction of C. albicans wild type cells, the secreted C. albicans peptide toxin candidalysin and mutant cells lacking candidalysin with epithelial cells. The candidalysin is responsible for epithelial cell damage and exhibits in its deuterated form an identifiable Raman signal in a frequency region distinct from the cellular frequency region. Vibration modes at 2100-2200 cm-1 attributed to carbon­deuterium bending and at 477 cm-1, attributed to the nitrogen­deuterium out-of-plane bending, found around the nucleus, can be assigned to deuterated candidalysin. Atomic force microscopy visualized 100 nm deep lesions on the cell and force-distance curves indicate the higher adhesion on pore surrounding after incubation with candidalysin. Candidalysin targets the plasma membrane, but is also found inside of the cytosol of epithelial cells during C. albicans infection.


Assuntos
Candida albicans , Células Epiteliais , Microscopia de Força Atômica , Análise Espectral Raman , Candida albicans/metabolismo , Células Epiteliais/microbiologia , Células Epiteliais/metabolismo , Microscopia de Força Atômica/métodos , Análise Espectral Raman/métodos , Humanos , Candidíase/microbiologia , Microscopia Confocal/métodos , Marcação por Isótopo , Imageamento Tridimensional , Deutério/química
2.
Analyst ; 148(22): 5627-5635, 2023 Nov 06.
Artigo em Inglês | MEDLINE | ID: mdl-37842964

RESUMO

Major drawbacks of direct mid-infrared spectroscopic imaging of single cells in an aqueous buffer are strong water absorption, low resolution typically above 10 µm, and Mie scattering effects. This study demonstrates how an indirect detection principle can overcome these drawbacks using the optical photothermal infrared (O-PTIR) technique for high-resolution discrete wavenumber imaging and fingerprint spectroscopy of cultivated cells as a model system in a simple liquid sample chamber. The O-PTIR spectra of six leukemia- and cancer-derived cell lines showed main IR bands near 1648, 1547, 1447, 1400, 1220, and 1088 cm-1. Five spectra of approximately 260 single cells per cell type were averaged, the O-PTIR data set was divided into leukemia-derived cells (THP-1, HL 60, Jurkat, and Raji) and cancer cells (HeLa and HepaRG), and partial least squares linear discriminant analysis (PLS-LDA) was applied in the spectral range 800-1800 cm-1 to train three classification models. A leukemia versus cancer cell model showed an accuracy of 90.0%, the HeLa versus HepaRG cell model had an accuracy of 95.4%, and the model for the distinction of leukemia cells had an accuracy of 75.4%. IR bands in linear discriminants (LDs) of the models were correlated with second derivative spectra that resolved more than 25 subbands. The IR and second derivative spectra of proteins, DNA, RNA and lipids were collected as references to confirm band assignments. O-PTIR images of single cells at a 200 nm step size were acquired at 1086, 1548, and 1746 cm-1 to visualize the nucleic acid, protein, and lipid distribution, respectively. Variations in subcellular features and in the lipid-to-protein and nucleic acid-to-protein ratios were identified that were consistent with biomolecular information in LDs. In conclusion, O-PTIR can provide high-quality spectra and images with submicron resolution of single cells in aqueous buffers that offer prospects in high-content screening applications.


Assuntos
Leucemia , Ácidos Nucleicos , Humanos , Espectrofotometria Infravermelho/métodos , Diagnóstico por Imagem , Água/química , Lipídeos
3.
Anal Bioanal Chem ; 415(25): 6257-6267, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37640827

RESUMO

Advanced glycation end products (AGEs) form extracellular crosslinking with collagenous proteins, which contributes to the development of diabetic complications. In this study, AGEs-related pentosidine (PENT) crosslinks-induced structural and biochemical changes are studied using multimodal multiphoton imaging, Raman spectroscopy and atomic force microscopy (AFM). Decellularized equine pericardium (EP) was glycated with four ribose concentrations ranging between 5 and 200 mM and monitored for up to 30 days. Two-photon excited fluorescence (TPEF) and second harmonic generation (SHG) microscopic imaging probed elastin and collagen fibers, respectively. The glycated EP showed a decrease in the SHG intensities associated with loss of non-centrosymmetry of collagen and an increase of TPEF intensities associated with PENT crosslinks upon glycation. TPEF signals from elastin fibers were unaffected. A three-dimensional reconstruction with SHG + TPEF z-stack images visualized the distribution of collagen and elastin within the EP volume matrix. In addition, Raman spectroscopy (RS) detected changes in collagen-related bands and discriminated glycated from untreated EP. Furthermore, AFM scans showed that the roughness increases and the D-unit structure of fibers remained unchanged during glycation. The PENT crosslinked-induced changes are discussed in the context of previous studies of glutaraldehyde- and genipin-induced crosslinking and collagenase-induced digestion of collagen. We conclude that TPEF, SHG, RS, and AFM are effective, label-free, and non-destructive methods to investigate glycated tissues, differentiate crosslinking processes, and characterize general collagen-associated and disease-related changes, in particular by their RS fingerprints.

4.
Spectrochim Acta A Mol Biomol Spectrosc ; 302: 123136, 2023 Dec 05.
Artigo em Inglês | MEDLINE | ID: mdl-37454437

RESUMO

Optical constants functions of analytes are indispensable for the effective design of plasmonic sensors. Such sensors are potentially able to enhance the sensitivity by several order of magnitudes which can greatly facilitate the determination of the generally weak spectral signals caused by vibrational circular dichroism. Accordingly, to demonstrate how to obtain these functions, we have determined the dielectric and chirality admittance functions of α-Pinene and Propylene oxide in the mid-infrared spectral range using attenuated total reflection and vibrational circular dichroism spectroscopy. Our iterative formalism starts with an estimation of the absorption index function, followed by the calculation of the refractive index function using the Kramers-Kronig relation and a modelled spectrum based on Fresnel's equations. By comparing the experimental and modelled spectra, we improve the absorption index function. To determine the chirality admittance function, we use the same iterative formalism, but with a modified 4x4 matrix formalism formulated by Berreman. Our results show that the experimental absorbance difference is independent of the dielectric function of the chiral substance and depends linearly on the cuvette thickness. Additionally, we provide a sum rule that can be used to assess the quality of VCD spectra and determine the position of the baseline. Our findings provide crucial insights into the optical properties of chiral substances in the mid-infrared spectral range, which have important implications for a range of applications in fields such as analytical chemistry and materials science.

5.
Cancers (Basel) ; 15(7)2023 Apr 05.
Artigo em Inglês | MEDLINE | ID: mdl-37046822

RESUMO

Raman spectroscopy offers label-free assessment of bladder tissue for in vivo and ex vivo intraoperative applications. In a retrospective study, control and cancer specimens were prepared from ten human bladder resectates. Raman microspectroscopic images were collected from whole tissue samples in a closed chamber at 785 nm laser excitation using a 20× objective lens and 250 µm step size. Without further preprocessing, Raman images were decomposed by the hyperspectral unmixing algorithm vertex component analysis into endmember spectra and their abundancies. Hierarchical cluster analysis distinguished endmember Raman spectra that were assigned to normal bladder, bladder cancer, necrosis, epithelium and lipid inclusions. Interestingly, Raman spectra of microplastic particles, pigments or carotenoids were detected in 13 out of 20 specimens inside tissue and near tissue margins and their identity was confirmed by spectral library surveys. Hypotheses about the origin of these foreign materials are discussed. In conclusion, our Raman workflow and data processing protocol with minimal user interference offers advantages for future clinical translation such as intraoperative tumor detection and label-free material identification in complex matrices.

6.
Sci Rep ; 12(1): 18785, 2022 11 05.
Artigo em Inglês | MEDLINE | ID: mdl-36335148

RESUMO

In recent years, vibrational spectroscopic techniques based on Fourier transform infrared (FTIR) or Raman microspectroscopy have been suggested to fulfill the unmet need for microplastic particle detection and identification. Inter-system comparison of spectra from reference polymers enables assessing the reproducibility between instruments and advantages of emerging quantum cascade laser-based optical photothermal infrared (O-PTIR) spectroscopy. In our work, IR and Raman spectra of nine plastics, namely polyethylene, polypropylene, polyvinyl chloride, polyethylene terephthalate, polycarbonate, polystyrene, silicone, polylactide acid and polymethylmethacrylate were simultaneously acquired using an O-PTIR microscope in non-contact, reflection mode. Comprehensive band assignments were presented. We determined the agreement of O-PTIR with standalone attenuated total reflection FTIR and Raman spectrometers based on the hit quality index (HQI) and introduced a two-dimensional identification (2D-HQI) approach using both Raman- and IR-HQIs. Finally, microplastic particles were prepared as test samples from known materials by wet grinding, O-PTIR data were collected and subjected to the 2D-HQI identification approach. We concluded that this framework offers improved material identification of microplastic particles in environmental, nutritious and biological matrices.


Assuntos
Microplásticos , Poluentes Químicos da Água , Plásticos , Análise Espectral Raman/métodos , Reprodutibilidade dos Testes , Polipropilenos , Espectroscopia de Infravermelho com Transformada de Fourier , Monitoramento Ambiental , Poluentes Químicos da Água/análise
7.
Materials (Basel) ; 15(20)2022 Oct 14.
Artigo em Inglês | MEDLINE | ID: mdl-36295240

RESUMO

(1) Background: Decalcified enamel and dentin surfaces can be regenerated with non-fluoride-containing biomimetic systems. This study aimed to investigate the effect of a zinc carbonate-hydroxyapatite-containing dentifrice on artificially demineralized enamel and dentin surfaces. (2) Methods: Human enamel and dentin discs were prepared and subjected to surface demineralization with 30% orthophosphoric acid for 60 s. Subsequently, in the test group (n = 20), the discs were treated three times a day for 3 min with a zinc carbonate-hydroxyapatite-containing toothpaste (biorepair®). Afterwards, all samples were gently rinsed with PBS (5 s) and stored in artificial saliva until next use. Samples from the control group (n = 20) received no dentifrice-treatment and were stored in artificial saliva, exclusively. After 15 days of daily treatment, specimens were subjected to Raman spectroscopy, energy-dispersive X-ray micro-analysis (EDX), white-light interferometry, and profilometry. (3) Results: Raman spectroscopy and white-light interferometry revealed no significant differences compared to the untreated controls. EDX analysis showed calcium phosphate and silicon dioxide precipitations on treated dentin samples. In addition, treated dentin surfaces showed significant reduced roughness values. (4) Conclusions: Treatment with biorepair® did not affect enamel surfaces as proposed. Minor mineral precipitation and a reduction in surface roughness were detected among dentin surfaces only.

8.
Talanta ; 246: 123501, 2022 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-35525057

RESUMO

ß-cyclodextrin/graphene oxide (GO-ß-CD) was applied for dispersive micro-solid phase extraction (DMSPE) of uranyl ions (UO22+) from water samples and their determination by energy-dispersive (EDXRF) and total-reflection X-ray fluorescence spectrometry (TXRF). The structure of GO-ß-CD was characterized by X-ray photoelectron spectroscopy, scanning electron microscopy, Fourier transform infrared spectroscopy, and Raman spectroscopy. The results of batch adsorption experiment indicate that the maximum recoveries for UO22+ ions are observed at pH 4.5. The Langmuir isotherm model fits the adsorption data, which stands for the chemisorption mechanism. The obtained adsorption capacity of 87.7 mg g-1 indicates a great potential of the synthesized adsorbent in the UO22+ ions preconcentration. The GO-ß-CD exhibits high resistance to high ionic strength (up to 2 mol L-1), indicating that high salinity samples can be treated with the evaluated preconcentration procedure. The obtained limit of detection values were 0.40 µg L-1 for the EDXRF and only 0.014 µg L-1 for TXRF analysis. The accuracy of the method was verified by analyzing certified reference material (spring water NIST-SRM 1640a) and spiked water samples (mineral, lake, river, and artificial sea water).


Assuntos
Grafite , Urânio , beta-Ciclodextrinas , Adsorção , Grafite/química , Água/química , Raios X , beta-Ciclodextrinas/química
9.
Anal Chem ; 94(3): 1575-1584, 2022 01 25.
Artigo em Inglês | MEDLINE | ID: mdl-35015512

RESUMO

Tissue cross-linking represents an important and often used technique to enhance the mechanical properties of biomaterials. For the first time, we investigated biochemical and structural properties of genipin (GE) cross-linked equine pericardium (EP) using optical imaging techniques in tandem with quantitative atomic force microscopy (AFM). EP was cross-linked with GE at 37 °C, and its biochemical and biomechanical properties were observed at various time points up to 24 h. GE cross-linked EP was monitored by the normalized ratio between its second-harmonic generation (SHG) and two-photon autofluorescence emissions and remained unchanged for untreated EP; however, a decreasing ratio due to depleted SHG and elevated autofluorescence and a fluorescence band at 625 nm were found for GE cross-linked EP. The mean autofluorescence lifetime of GE cross-linked EP also decreased. The biochemical signature of GE cross-linker and shift in collagen bands were detected and quantified using shifted excitation Raman difference spectroscopy as an innovative approach for tackling artifacts with high fluorescence backgrounds. AFM images indicated a higher and increasing Young's modulus correlated with cross-linking, as well as collagen structural changes in GE cross-linked EP, qualitatively explaining the observed decrease in the second-harmonic signal. In conclusion, we obtained detailed information about the biochemical, structural, and biomechanical effects of GE cross-linked EP using a unique combination of optical and force microscopy techniques in a nondestructive and label-free manner.


Assuntos
Colágeno , Iridoides , Animais , Colágeno/química , Módulo de Elasticidade , Cavalos , Iridoides/análise , Pericárdio
11.
Analyst ; 146(22): 6760-6767, 2021 Nov 08.
Artigo em Inglês | MEDLINE | ID: mdl-34704561

RESUMO

Shifted excitation Raman difference spectroscopy (SERDS) can be used as an instrumental baseline correction technique to retrieve Raman bands in highly fluorescent samples. Genipin (GE) cross-linked equine pericardium (EP) was used as a model system since a blue pigment is formed upon cross-linking, which results in a strong fluorescent background in the Raman spectra. EP was cross-linked with 0.25% GE solution for 0.5 h, 2 h, 4 h, 6 h, 12 h, and 24 h, and compared with corresponding untreated EP. Raman spectra were collected with three different excitation wavelengths. For the assessment of the SERDS technique, the preprocessed SERDS spectra of two excitation wavelengths (784 nm-786 nm) were compared with the mathematical baseline-corrected Raman spectra at 785 nm excitation using extended multiplicative signal correction, rubberband, the sensitive nonlinear iterative peak and polynomial fitting algorithms. Whereas each baseline correction gave poor quality spectra beyond 6 h GE crosslinking with wave-like artefacts, the SERDS technique resulted in difference spectra, that gave superior reconstructed spectra with clear collagen and resonance enhanced GE pigment bands with lower standard deviation. Key for this progress was an advanced difference optimization approach that is described here. Furthermore, the results of the SERDS technique were independent of the intensity calibration because the system transfer response was compensated by calculating the difference spectrum. We conclude that this SERDS strategy can be transferred to Raman studies on biological and non-biological samples with a strong fluorescence background at 785 nm and also shorter excitation wavelengths which benefit from more intense scattering intensities and higher quantum efficiencies of CCD detectors.


Assuntos
Artefatos , Análise Espectral Raman , Algoritmos , Animais , Calibragem , Corantes , Cavalos
12.
Biomedicines ; 9(5)2021 May 20.
Artigo em Inglês | MEDLINE | ID: mdl-34065470

RESUMO

Extracellular vesicles (EVs) are membrane-enclosed structures ranging in size from about 60 to 800 nm that are released by the cells into the extracellular space; they have attracted interest as easily available biomarkers for cancer diagnostics. In this study, EVs from plasma of control and prostate cancer patients were fractionated by differential centrifugation at 5000× g, 12,000× g and 120,000× g. The remaining supernatants were purified by ultrafiltration to produce EV-depleted free-circulating (fc) fractions. Spontaneous Raman and surface-enhanced Raman spectroscopy (SERS) at 785 nm excitation using silver nanoparticles (AgNPs) were employed as label-free techniques to collect fingerprint spectra and identify the fractions that best discriminate between control and cancer patients. SERS spectra from 10 µL droplets showed an enhanced Raman signature of EV-enriched fractions that were much more intense for cancer patients than controls. The Raman spectra of dehydrated pellets of EV-enriched fractions without AgNPs were dominated by spectral contributions of proteins and showed variations in S-S stretch, tryptophan and protein secondary structure bands between control and cancer fractions. We conclude that the AgNPs-mediated SERS effect strongly enhances Raman bands in EV-enriched fractions, and the fractions, EV12 and EV120 provide the best separation of cancer and control patients by Raman and SERS spectra.

13.
Anal Chem ; 93(8): 3813-3821, 2021 03 02.
Artigo em Inglês | MEDLINE | ID: mdl-33596051

RESUMO

We demonstrate the ability of nondestructive optical imaging techniques such as second-harmonic generation (SHG), two-photon fluorescence (TPF), fluorescence lifetime imaging (FLIM), and Raman spectroscopy (RS) to monitor biochemical and mechanical alterations in tissues upon collagen degradation. Decellularized equine pericardium (EP) was treated with 50 µg/mL bacterial collagenase at 37 °C for 8, 16, 24, and 32 h. The SHG ratio (defined as the normalized ratio between SHG and TPF signals) remained unchanged for untreated EP (stored in phosphate-buffered solution (PBS)), whereas treated EP showed a trend of a decreasing SHG ratio with increasing collagen degradation. In the fluorescence domain, treated EP experienced a red-shifted emission and the fluorescence lifetime had a trend of decreasing lifetime with increasing collagen digestion. RS monitors collagen degradation, the spectra had less intense Raman bands at 814, 852, 938, 1242, and 1270 cm-1. Non-negative least-squares (NNLS) modeling quantifies collagen loss and relative increase of elastin. The Young's modulus, derived from atomic force microscope-based nanoindentation experiments, showed a rapid decrease within the first 8 h of collagen degradation, whereas more gradual changes were observed for optical modalities. We conclude that optical imaging techniques like SHG, RS, and FLIM can monitor collagen degradation in a label-free manner and coarsely access mechanical properties in a nondestructive manner.


Assuntos
Colágeno , Imagem Óptica , Animais , Módulo de Elasticidade , Elastina , Cavalos , Análise Espectral Raman
14.
J Biophotonics ; 14(1): e202000280, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-32951321

RESUMO

Breast conserving surgery (BCS) offering similar surgical outcomes as mastectomy while retaining breast cosmesis is becoming increasingly popular for the management of early stage breast cancers. However, its association with reoperation rates of 20% to 40% following incomplete tumor removal warrants the need for a fast and accurate intraoperative surgical margin assessment tool that offers cellular, structural and molecular information of the whole specimen surface to a clinically relevant depth. Biophotonic technologies are evolving to qualify as such an intraoperative tool for clinical assessment of breast cancer surgical margins at the microscopic and macroscopic scale. Herein, we review the current research in the application of biophotonic technologies such as photoacoustic imaging, Raman spectroscopy, multimodal multiphoton imaging, diffuse optical imaging and fluorescence imaging using medically approved dyes for breast cancer detection and/or tumor subtype differentiation toward intraoperative assessment of surgical margins in BCS specimens, and possible challenges in their route to clinical translation.


Assuntos
Neoplasias da Mama , Margens de Excisão , Mama , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/cirurgia , Feminino , Humanos , Mastectomia , Mastectomia Segmentar
15.
Sensors (Basel) ; 20(23)2020 Nov 24.
Artigo em Inglês | MEDLINE | ID: mdl-33255459

RESUMO

Wide field Raman imaging using the integral field spectroscopy approach was used as a fast, one shot imaging method for the simultaneous collection of all spectra composing a Raman image. For the suppression of autofluorescence and background signals such as room light, shifted excitation Raman difference spectroscopy (SERDS) was applied to remove background artifacts in Raman spectra. To reduce acquisition times in wide field SERDS imaging, we adapted the nod and shuffle technique from astrophysics and implemented it into a wide field SERDS imaging setup. In our adapted version, the nod corresponds to the change in excitation wavelength, whereas the shuffle corresponds to the shifting of charges up and down on a Charge-Coupled Device (CCD) chip synchronous to the change in excitation wavelength. We coupled this improved wide field SERDS imaging setup to diode lasers with 784.4/785.5 and 457.7/458.9 nm excitation and applied it to samples such as paracetamol and aspirin tablets, polystyrene and polymethyl methacrylate beads, as well as pork meat using multiple accumulations with acquisition times in the range of 50 to 200 ms. The results tackle two main challenges of SERDS imaging: gradual photobleaching changes the autofluorescence background, and multiple readouts of CCD detector prolong the acquisition time.

16.
Anal Chem ; 92(24): 15745-15756, 2020 12 15.
Artigo em Inglês | MEDLINE | ID: mdl-33225709

RESUMO

The variable configuration of Raman spectroscopic platforms is one of the major obstacles in establishing Raman spectroscopy as a valuable physicochemical method within real-world scenarios such as clinical diagnostics. For such real world applications like diagnostic classification, the models should ideally be usable to predict data from different setups. Whether it is done by training a rugged model with data from many setups or by a primary-replica strategy where models are developed on a 'primary' setup and the test data are generated on 'replicate' setups, this is only possible if the Raman spectra from different setups are consistent, reproducible, and comparable. However, Raman spectra can be highly sensitive to the measurement conditions, and they change from setup to setup even if the same samples are measured. Although increasingly recognized as an issue, the dependence of the Raman spectra on the instrumental configuration is far from being fully understood and great effort is needed to address the resulting spectral variations and to correct for them. To make the severity of the situation clear, we present a round robin experiment investigating the comparability of 35 Raman spectroscopic devices with different configurations in 15 institutes within seven European countries from the COST (European Cooperation in Science and Technology) action Raman4clinics. The experiment was developed in a fashion that allows various instrumental configurations ranging from highly confocal setups to fibre-optic based systems with different excitation wavelengths. We illustrate the spectral variations caused by the instrumental configurations from the perspectives of peak shifts, intensity variations, peak widths, and noise levels. We conclude this contribution with recommendations that may help to improve the inter-laboratory studies.

17.
Molecules ; 25(17)2020 Aug 25.
Artigo em Inglês | MEDLINE | ID: mdl-32854230

RESUMO

Biomaterials used in tissue engineering and regenerative medicine applications benefit from longitudinal monitoring in a non-destructive manner. Label-free imaging based on fluorescence lifetime imaging (FLIm) and Raman spectroscopy were used to monitor the degree of genipin (GE) cross-linking of antigen-removed bovine pericardium (ARBP) at three incubation time points (0.5, 1.0, and 2.5 h). Fluorescence lifetime decreased and the emission spectrum redshifted compared to that of uncross-linked ARBP. The Raman signature of GE-ARBP was resonance-enhanced due to the GE cross-linker that generated new Raman bands at 1165, 1326, 1350, 1380, 1402, 1470, 1506, 1535, 1574, 1630, 1728, and 1741 cm-1. These were validated through density functional theory calculations as cross-linker-specific bands. A multivariate multiple regression model was developed to enhance the biochemical specificity of FLIm parameters fluorescence intensity ratio (R2 = 0.92) and lifetime (R2 = 0.94)) with Raman spectral results. FLIm and Raman spectroscopy detected biochemical changes occurring in the collagenous tissue during the cross-linking process that were characterized by the formation of a blue pigment which affected the tissue fluorescence and scattering properties. In conclusion, FLIm parameters and Raman spectroscopy were used to monitor the degree of cross-linking non-destructively.


Assuntos
Reagentes de Ligações Cruzadas/química , Matriz Extracelular/química , Iridoides/química , Pericárdio/química , Animais , Bovinos , Imagem Óptica , Pericárdio/diagnóstico por imagem , Análise Espectral Raman
18.
Front Cardiovasc Med ; 7: 122, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32793637

RESUMO

Background: Fluorescence lifetime imaging (FLIm) is a spectroscopic imaging technique able to characterize the composition of luminal surface of arterial vessels. Studies of human coronary samples demonstrated that distinct atherosclerotic lesion types are characterized by FLIm features associate with distinct tissue molecular makeup. While conventional histology has provided indications about potential sources of molecular contrast, specific information about the origin of FLIm signals is lacking. Here we investigate whether Raman spectroscopy, a technique able to evaluate chemical content of biological samples, can provide additional insight into the origin of FLIm contrast. Methods: Six human coronary artery samples were imaged using FLIm (355 nm excitation)-Raman spectroscopy (785 nm excitation) via a multimodal fiber optic probe. The spatial distribution of molecular contrast in FLIm images was analyzed in relationship with histological findings. Raman data was investigated using an endmember technique and compared with histological findings. A descriptive modeling approach based on multivariate regression was used to identify Raman bands related with changes in lifetime in four spectral channels (violet: 387/35 nm, blue: 443/29 nm, green: 546/38 nm, and red: 628/53 nm). Results: Fluorescence lifetime variations in the violet, blue and green spectral bands were observed for distinct areas of each tissue sample associated with distinct pathologies. Analysis of Raman signals from areas associated with normal, pathological intimal thickening, and fibrocalcific regions demonstrated the presence of hydroxyapatite, collagenous proteins, carotene, cholesterol, and triglycerides. The FLIm and Raman descriptive modeling analysis indicated that lifetime increase in the violet spectral band was associated with increased presence of cholesterol and carotenes, a new finding consistent with LDL accumulation in atherosclerotic lesions, and not with collagen proteins, as expected from earlier studies. Conclusions: The systematic, quantitative analysis of the multimodal FLIm-Raman dataset using a descriptive modeling approach led to the identification of LDL accumulation as the primary source of lifetime contrast in atherosclerotic lesions in the violet spectral range. Earlier FLIm validation studies relying on histopathological findings had associated this contrast to increased collagen content, also present in advanced lesions, thus demonstrating the benefits of alternative validation methods.

19.
Anal Chem ; 92(15): 10659-10667, 2020 08 04.
Artigo em Inglês | MEDLINE | ID: mdl-32598134

RESUMO

Bovine pericardium (BP) is a vascular biomaterial used in cardiovascular surgery that is typically cross-linked for masking antigenicity and enhance stability. There is a need for biochemical evaluation of the tissue properties prior to implantation to ensure that quality and reliability standards are met. Here, engineered antigen removed BP (ARBP) that was cross-linked with 0.2% and 0.6% glutaraldehyde (GA), and further calcified in vitro to simulate graft calcifications upon implantation was characterized nondestructively using fluorescence lifetime imaging (FLIm) to identify regions of interest which were then assessed by Raman spectroscopy. We observed that the tissue fluorescence lifetime shortened, and that Raman bands at 856, 935, 1282, and 1682 cm-1 decreased, and at 1032 and 1627 cm-1 increased with increasing GA cross-linking. Independent classification analysis based on fluorescence lifetime and on Raman spectra discriminated between GA-ARBP and untreated ARBP with an accuracy of 91% and 66%, respectively. Pearson's correlation analysis showed a strong correlation between pyridinium cross-links measured with high-performance liquid chromatography and fluorescence lifetime measured at 380-400 nm (R = -0.76, p = 0.00094), as well as Raman bands at 856 cm-1 for hydroxy-proline (R = -0.68, p = 0.0056) and at 1032 cm-1 for hydroxy-pyridinium (R = 0.74, p = 0.0016). Calcified areas of GA cross-linked tissue showed characteristic hydroxyapatite (959 and 1038 cm-1) bands in the Raman spectrum and fluorescence lifetime shortened by 0.4 ns compared to uncalcified regions. FLIm-guided Raman imaging could rapidly identify degrees of cross-linking and detected calcified regions with high chemical specificity, an ability that can be used to monitor tissue engineering processes for applications in regenerative medicine.


Assuntos
Materiais Biocompatíveis/metabolismo , Calcificação Fisiológica , Imagem Óptica/métodos , Pericárdio/diagnóstico por imagem , Pericárdio/metabolismo , Análise Espectral Raman , Animais , Bovinos
20.
Analyst ; 144(15): 4488-4492, 2019 Aug 07.
Artigo em Inglês | MEDLINE | ID: mdl-31287453

RESUMO

High-throughput screening Raman spectroscopy (HTS-RS) with automated localization algorithms offers unsurpassed speed and sensitivity to investigate the effect of dithiothreitol on the diatom Phaedactylum tricornutum. The HTS-RS capability that was demonstrated for this model system can be transferred to unmet analytical applications such as kinetic in vivo studies of microalgal assemblages.


Assuntos
Diatomáceas/efeitos dos fármacos , Ditiotreitol/farmacologia , Algoritmos , Diatomáceas/efeitos da radiação , Ensaios de Triagem em Larga Escala/métodos , Luz , Análise Espectral Raman/métodos , Xantofilas/química , Xantofilas/metabolismo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA