Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 89
Filtrar
1.
Front Psychol ; 15: 1368989, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38911953

RESUMO

Most people, evidence suggests, have a hard time thinking straight. Symbolic logic is a tool that can help remedy this problem. Unfortunately, it is highly abstract and uses symbols whose meanings rely on unintuitive arbitrary conventions. Without sacrificing rigor, iconic logic is more concrete and uses icons that resemble what they stand for and whose meanings are thus easier to picture, process, and remember. Here I review and critique iconic existential graphs and concept diagrams-the former link iconic logic to iconic mathematics; the latter expand popular Euler or Venn diagrams and have, to some degree, been empirically investigated for user-friendliness. I lay out how expertise in perception, cognition, and genetics can inform and improve such empirical research to help make iconic logic more ergonomic. After all, logic is a tool, and tools should not only suit their use but also their user.

2.
Eur J Cardiothorac Surg ; 65(4)2024 Mar 29.
Artigo em Inglês | MEDLINE | ID: mdl-38597905

RESUMO

OBJECTIVES: This study aimed to evaluate the short-/mid-term outcome of patients with complex dextro (d)-/levo (l)-transposition of the great arteries (TGA), ventricular septal defect and left ventricular outflow tract obstructions. METHODS: A single-centre, retrospective review of all complex dextro-TGA (n = 85) and levo-TGA (n = 22) patients undergoing different surgeries [Arterial switch operation + left ventricular outflow tract obstruction-resection (ASO-R), half-turned truncal switch/Mair (HTTS), Nikaidoh and Rastelli] between May 1990 and September 2022 was performed. Groups were analysed using Kruskal-Wallis test with post hoc pairwise comparison and Kaplan-Meier time-to-event models. RESULTS: A total of 107 patients [ASO-R (n = 20), HTTS (n = 23), Nikaidoh (n = 21), Rastelli (n = 43)] were included, with a median age of 1.0 year (0.5-2.5) and surgical repair median follow-up was 3.8 years (0.3-10.5). Groups did not differ in respect to early postoperative complications/early mortality. Five-year overall survival curves were comparable: ASO-R 78.9% (53.2-91.5), HTTS 75.3% (46.8-89.9), Nikaidoh 85% (60.4-94.9) and Rastelli 83.9% (67.5-92.5), P = 0.9. Highest rates of right ventricular outflow tract (RVOT) reinterventions [33.3% and 32.6% (P = 0.04)] and reoperations [28.6% and 32.6% (P = 0.02)] occurred after Nikaidoh and Rastelli procedures. However, overall freedom from RVOT reinterventions and RVOT reoperations at 5 years did not differ statistically significantly between the groups (ASO-R, HTTS, Nikaidoh and Rastelli): 94.4% (66.6-99.2), 69.1% (25.4-90.5), 67.8% (34-86.9), 64.4% (44.6-78.7), P = 0.2, and 90.0% (65.6-97.4), 91% (50.8-98.7), 65.3% (32.0-85.3) and 67.0% (47.4-80.6), P = 0.3. CONCLUSIONS: Surgical repair of complex dextro-/levo-TGA can be performed with satisfying early/mid-term survival. RVOT reinterventions/reoperations were frequent, with highest rates after Nikaidoh and Rastelli procedures. Left ventricular outflow tract obstruction reoperations were rare with zero events after Nikaidoh and HTTS procedures.


Assuntos
Transposição das Grandes Artérias , Transposição dos Grandes Vasos , Obstrução da Via de Saída Ventricular Esquerda , Obstrução do Fluxo Ventricular Externo , Humanos , Lactente , Transposição dos Grandes Vasos/cirurgia , Obstrução do Fluxo Ventricular Externo/cirurgia , Transposição das Grandes Artérias/efeitos adversos , Transposição das Grandes Artérias/métodos , Artérias , Estudos Retrospectivos , Resultado do Tratamento
3.
Front Cardiovasc Med ; 10: 1256752, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37745106

RESUMO

Objectives: Due to the limited longevity of endovascular leads, children require thoughtful lifetime lead management strategies including conservation of access vessel patency. Consequently, there is an increasing interest in transvenous lead extraction (TLE) in children, however, data on TLE and the use of powered mechanical dissection sheaths is limited. Methods: We performed a retrospective cohort study analyzing all children <18 years that underwent TLE in our institution from 2015 to 2022. Procedural complexity, results and complications were defined as recommended by recent consensus statements. Results: Twenty-eight children [median age 12.8 (interquartile range 11.3-14.6) years] were included. Forty-one leads were extracted [median dwell time 85 (interquartile range 52-102) months]. Extractions of 31 leads (76%) in 22 patients (79%) were complex, requiring advanced extraction tools including powered bidirectional rotational dissection sheaths in 14 children. There were no major complications. Complete procedural success was achieved in 18 (64%) and clinical success in 27 patients (96%), respectively. Procedural success and complexity varied between lead types. The Medtronic SelectSecure™ lead was associated with increased odds of extraction by simple traction (p = 0.006) and complete procedural success (p < 0.001) while the Boston Scientific Fineline™ II lead family had increased odds of partial procedural failure (p = 0.017). Conclusions: TLE with the use of mechanical powered rotational dissection sheaths is feasible and safe in pediatric patients. In light of rare complications and excellent overall clinical success, TLE should be considered an important cornerstone in lifetime lead management in children. Particular lead types might be more challenging and less successful to extract.

4.
Catheter Cardiovasc Interv ; 102(4): 672-682, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37545179

RESUMO

BACKGROUND: Endovascular treatment of aortic coarctation (CoA) in children and adults frequently requires stent implantation. The aim of this study was to analyze long-term results after CoA treatment with bare and covered Cheatham-PlatinumTM (CP) stents in our institution and to derive recommendations for the differential use of these stent types. METHODS: In this retrospective single institution study, 212 patients received endovascular CoA treatment with bare (n = 71) and covered (n = 141) CP stents between September 1999 and July 2021, respectively. The indications for treatment were native CoA in 110/212 patients (51.9%) and re-coarctation after primary surgical or interventional treatment in 102/212 patients (48.1%). Median patient age at endovascular CoA treatment was 18.8 years [IQR 11.9; 35.8]. Long-term follow-up was available in 158/212 patients (74.5%) with a median follow-up of 7.3 years [IQR 4.3; 12.6]. RESULTS: Procedural success was achieved in 187/212 (88.2%) patients. Survival rate was 98.1% after 5, and 95.6% after 10 and 15 years, respectively. The probability of freedom from re-intervention was 93.0% after 5, 82.3% after 10 and 77.8% after 15 years, respectively. Freedom from re-interventions (44/158, 27.8%) did not differ between patients who received bare or covered CP stents (p = 0.715). Multivariable risk factor analysis identified previous CoA surgery (HR: 2.0, 95% confidence interval (CI): 1.1-3,9, p = 0.029), postdilatation (HR: 2,9, 95% CI: 1.1-6.3, p = 0.028) and age at intervention (HR: 0.96, 95% CI: 0.94-0.99, p = 0.002) as independent risk factors for re-intervention. Peri-procedural complications occurred in 15/212 (7.1%) patients (dissection/thrombosis of vascular access vessel: n = 9; bleeding: n = 1; stent dislocation: n = 2; aortic dissection/aortic wall rupture: n = 3). Long-term complications were observed in 36 patients and included stent fracture (n = 19), aneurysm formation (n = 14), endoleak (n = 1) and subclavian artery stenosis (n = 2). Peri-procedural and long-term complications did not differ between patients who received CoA treatment with bare or covered CP stents (all p > 0.05). CONCLUSION: Endovascular treatment of CoA using bare or covered CP stents can be performed safely and effectively with excellent long-term results. Survival, re-intervention and complication rate did not significantly differ between both stent types. However, individual stent selection is advisable with regard to CoA morphology and severity as well as patient age.


Assuntos
Coartação Aórtica , Procedimentos Endovasculares , Adulto , Criança , Humanos , Coartação Aórtica/diagnóstico por imagem , Coartação Aórtica/terapia , Coartação Aórtica/complicações , Seguimentos , Platina , Estudos Retrospectivos , Resultado do Tratamento , Stents/efeitos adversos , Procedimentos Endovasculares/efeitos adversos
5.
Front Psychol ; 14: 1149381, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37575437

RESUMO

This article lays out the foundation of a new language for easier written communication that is inherently reader-friendly and inherently international. Words usually consist of strings of sounds or squiggles whose meanings are merely a convention. In Icono, instead, they typically are strings of icons that illustrate what they stand for. "Train," for example, is expressed with the icon of a train, "future" with the icon of a clock surrounded by a clockwise arrow, and "mammal" with the icons of a cow and a mouse-their combination's meaning given by what they have in common. Moreover, Icono reveals sentence structure graphically before, rather than linguistically after, one begins reading. On smartphones and computers, writing icons can now be faster than writing alphabetic words. And using simple pictures as words helps those who struggle with conditions like dyslexia, aphasia, cerebral palsy, and autism with speech impairment. Because learning its pronunciation or phonetic spelling is optional rather than a prerequisite, and because it shows what it says, Icono is bound to be easier to learn to read-and then easier to read-than any other language, including our own.

6.
Catheter Cardiovasc Interv ; 102(2): 359-363, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37313625

RESUMO

Device thromboses after patent foramen ovale (PFO) and atrial septal defect (ASD) closure are rare but serious complications. They have been reported in different devices of virtually all manufacturers. Here, we report three cases of left atrial device thrombosis after atrial defect closure with the Gore® Cardioform septal occluder (GSO) in our recent institutional experience. All patients were symptomatic with new-onset neurological impairments and evidence of cerebral thromboembolism. Device thromboses have occurred despite antiplatelet therapy in two patients and moreover were observed late, at approximately 2 years after implantation, in two patients. One device was surgically explanted while in two cases, thrombi completely resolved with initiated anticoagulation. All patients had a favorable neurological recovery. Our observations suggest that regular follow-up echocardiography beyond 6 months after device implantation might be advisable in patients with GSO devices to rule out late device thromboses. More long-term follow-up data considering safety and late complications of contemporary PFO and ASD devices is required to establish confident evidence-based recommendations on long-term follow-up management and antithrombotic therapy regimen after PFO and ASD closure.


Assuntos
Fibrilação Atrial , Forame Oval Patente , Comunicação Interatrial , Dispositivo para Oclusão Septal , Trombose , Humanos , Resultado do Tratamento , Fibrilação Atrial/complicações , Comunicação Interatrial/terapia , Forame Oval Patente/complicações , Forame Oval Patente/diagnóstico por imagem , Forame Oval Patente/terapia , Trombose/diagnóstico por imagem , Trombose/etiologia , Trombose/terapia , Cateterismo Cardíaco/efeitos adversos , Desenho de Prótese
7.
Eur Heart J Case Rep ; 7(1): ytad030, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36727125

RESUMO

Background: Transcatheter correction of superior sinus venosus atrial septal defect (SVASD) with partial anomalous pulmonary venous drainage (PAPVD) of the right upper and/or right middle pulmonary vein (RUPV/RMPV) has recently been described as an alternative to surgical approach in a substantial number of patients. We describe a modified technical approach for transcatheter correction of SVASD using transoesophageal echocardiography (TOE) to confirm adequate stent landing zone and apposition and evaluate its feasibility, safety, and procedural success. Case summary: From 2019 to 2021, three consecutive patients received a transcatheter correction of SVASD with PAPVD by redirecting the superior vena cava and RUPV/RMPV to the left atrium by implantation of a custom-made covered Cheatham platinum stent (10-zig, length: 60-80 mm). Prior to stent implantation, a balloon testing was performed in the anticipated landing zone using TOE to confirm complete defect closure and unobstructed pulmonary venous drainage. Stent deployment and flaring of the interior stent portion were performed with TOE guidance to confirm adequate landing zone and apposition and to avoid residual shunt or pulmonary vein obstruction. Conclusion: Transcatheter correction of SVASD with PAPVD was performed without any complications. The follow-up period was 7.8, 13.6, and 29.8 months, respectively. During follow-up, no mortality, stent embolization, or obstruction of pulmonary venous drainage occurred. The TOE-guided modified transcatheter approach for correction of SVASD with PAPVD is safe and feasible with excellent post-procedural results and represents an alternative to surgical treatment in a pre-selected patient cohort.

8.
Front Cardiovasc Med ; 9: 1024053, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36531701

RESUMO

Background: Double outlet right ventricle (DORV) describes a group of congenital heart defects where pulmonary artery and aorta originate completely or predominantly from the right ventricle. The individual anatomy of DORV patients varies widely with multiple subtypes classified. Although the majority of morphologies is suitable for biventricular repair (BVR), complex DORV anatomy can render univentricular palliation (UVP) the only option. Thus, patient-specific decision-making is critical for optimal surgical treatment planning. The evolution of image processing and rapid prototyping techniques facilitate the generation of detailed virtual and physical 3D models of the patient-specific anatomy which can support this important decision process within the Heart Team. Materilas and methods: The individual cardiovascular anatomy of nine patients with complex DORV, in whom surgical decision-making was not straightforward, was reconstructed from either computed tomography or magnetic resonance imaging data. 3D reconstructions were used to characterize the morphologic details of DORV, such as size and location of the ventricular septal defect (VSD), atrioventricular valve size, ventricular volumes, relationship between the great arteries and their spatial relation to the VSD, outflow tract obstructions, coronary artery anatomy, etc. Additionally, physical models were generated. Virtual and physical models were used in the preoperative assessment to determine surgical treatment strategy, either BVR vs. UVP. Results: Median age at operation was 13.2 months (IQR: 9.6-24.0). The DORV transposition subtype was present in six patients, three patients had a DORV-ventricular septal defect subtype. Patient-specific reconstruction was feasible for all patients despite heterogeneous image quality. Complex BVR was feasible in 5/9 patients (55%). Reasons for unsuitability for BVR were AV valve chordae interfering with potential intraventricular baffle creation, ventricular hypoplasia and non-committed VSD morphology. Evaluation in particular of qualitative data from 3D models was considered to support comprehension of complex anatomy. Conclusion: Image-based 3D reconstruction of patient-specific intracardiac anatomy provides valuable additional information supporting decision-making processes and surgical planning in complex cardiac malformations. Further prospective studies are required to fully appreciate the benefits of 3D technology.

9.
Front Cardiovasc Med ; 9: 952080, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36158803

RESUMO

Background: Despite improved survival a substantial number of Fontan patients eventually develop late failure. Fontan-associated liver disease (FALD) is the most frequent end-organ dysfunction. Although impaired hemodynamics and Fontan failure correlate with FALD severity, no association between hepatic functional metabolic impairment and Fontan hemodynamics has been established. Hypothesis: Metabolic liver function measured by liver maximum function capacity test (LiMAx®) correlates with Fontan hemodynamics and Fontan failure. Methods: From 2020 to 2022, 58 adult Fontan patients [median age: 29.3 years, IQR (12.7), median follow-up time after Fontan operation: 23.2 years, IQR (8.7)] were analyzed in a cross-sectional study. Hemodynamic assessment included echocardiography, cardiopulmonary exercise testing and invasive hemodynamic evaluation. Fontan failure was defined based on commonly applied clinical criteria and our recently composed multimodal Fontan failure score. Results: LiMAx® test revealed normal maximum liver function capacity in 40 patients (>315 µg/h*kg). In 18 patients a mild to moderate impairment was detected (140-314 µg/h*kg), no patient suffered from severe hepatic deterioration (≤ 139 µg/kg*h). Fontan failure was present in 15 patients. Metabolic liver function was significantly reduced in patients with increased pulmonary artery pressure (p = 0.041. r = -0.269) and ventricular end-diastolic pressure (p = 0.033, r = -0.325), respectively. In addition, maximum liver function capacity was significantly impaired in patients with late Fontan failure (289.0 ± 99.6 µg/kg*h vs. 384.5 ± 128.6 µg/kg*h, p = 0.007). Conclusion: Maximum liver function capacity as determined by LiMAx® was significantly reduced in patients with late Fontan failure. In addition, elevated pulmonary artery pressure and end-diastolic ventricular pressure were associated with hepatic functional metabolic impairment.

10.
Front Cardiovasc Med ; 9: 898701, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35990961

RESUMO

Background: Uneven hepatic venous blood flow distribution (HFD) to the pulmonary arteries is hypothesized to be responsible for the development of intrapulmonary arteriovenous malformations (PAVM) in patients with univentricular physiology. Thus, achieving uniform distribution of hepatic blood flow is considered favorable. However, no established method for the prediction of the post-interventional hemodynamics currently exists. Computational fluid dynamics (CFD) offers the possibility to quantify HFD in patient-specific anatomies before and after virtual treatment. In this study, we evaluated the potential benefit of CFD-assisted treatment planning. Materials and methods: Three patients with total cavopulmonary connection (TCPC) and PAVM underwent cardiovascular magnetic resonance imaging (CMR) and computed tomography imaging (CT). Based on this imaging data, the patient-specific anatomy was reconstructed. These patients were considered for surgery or catheter-based intervention aiming at hepatic blood flow re-routing. CFD simulations were then performed for the untreated state as well as for different surgical and interventional treatment options. These treatment options were applied as suggested by treating cardiologists and congenital heart surgeons with longstanding experience in interventional and surgical treatment of patients with univentricular physiology. HFD was quantified for all simulations to identify the most viable treatment decision regarding redistribution of hepatic blood flow. Results: For all three patients, the complex TCPC anatomy could be reconstructed. However, due to the presence of metallic stent implants, hybrid models generated from CT as well as CMR data were required. Numerical simulation of pre-interventional HFD agreed well with angiographic assessment and physiologic considerations. One treatment option resulting in improvement of HFD was identified for each patient. In one patient follow-up data after treatment was available. Here, the virtual treatment simulation and the CMR flow measurements differed by 15%. Conclusion: The combination of modern computational methods as well as imaging methods for assessment of patient-specific anatomy and flow might allow to optimize patient-specific therapy planning in patients with pronounced hepatic flow mismatch and PAVM. In this study, we demonstrate that these methods can also be applied in patients with complex univentricular physiology and extensive prior interventions. However, in those cases, hybrid approaches utilizing information of different image modalities may be required.

11.
Front Psychol ; 13: 890362, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35769758

RESUMO

Mathematics is a struggle for many. To make it more accessible, behavioral and educational scientists are redesigning how it is taught. To a similar end, a few rogue mathematicians and computer scientists are doing something more radical: they are redesigning mathematics itself, improving its ergonomic features. Charles Peirce, an important contributor to ordinary symbolic logic, also introduced a rigorous but non-symbolic, graphical alternative to it that is easier to picture. In the spirit of this iconic logic, George Spencer-Brown founded iconic mathematics. Performing iconic arithmetic, algebra, and even trigonometry, resembles doing calculations on an abacus, which is still popular in education today, has aided humanity for millennia, helps even when it is merely imagined, and ameliorates severe disability in basic computation. Interestingly, whereas some intellectually disabled individuals excel in very complex numerical tasks, others of normal intelligence fail even in very simple ones. A comparison of their wider psychological profiles suggests that iconic mathematics ought to suit the very people traditional mathematics leaves behind.

12.
Innovations (Phila) ; 17(3): 237-243, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35616926

RESUMO

Seven adult patients underwent a two-stage treatment of complex coarctation (CoA), including surgical revascularization of the left subclavian artery (LSA) to left common carotid artery (LCCA), followed by transcatheter covered stent implantation. The majority of patients (5 of 7, 71%) received 1 covered stent (covered Cheatham Platinum stent: 8 zig/45 mm [n = 2], 10 zig/60 mm [n = 1], 10 zig/65 mm [n = 1]; BeGraft: 24/48 mm [n = 2]). In 1 patient (14%), the implantation of 2 covered stents (BeGraft 20/48 mm) was necessary. During a median follow-up of 2.4 years (interquartile range, 0.1 to 4.9 years), complications occurred in 3 of 7 patients (43%), including an asymptomatic but severe stenosis of the LSA bypass (n = 1), a recoarctation with a mild endoleak (n = 1), and a severe endoleak (n = 1). Surgical revascularization of the LSA to the LCCA can successfully prepare for covered stent implantation in complex CoA in adult patients. This two-stage approach was feasible and safe with complications occurring in 3 of 7 patients (43%). All complications were managed by catheter reintervention only.


Assuntos
Coartação Aórtica , Implante de Prótese Vascular , Procedimentos Endovasculares , Adulto , Humanos , Coartação Aórtica/complicações , Coartação Aórtica/cirurgia , Aortografia/efeitos adversos , Implante de Prótese Vascular/efeitos adversos , Artéria Carótida Primitiva/cirurgia , Endoleak/etiologia , Procedimentos Endovasculares/efeitos adversos , Desenho de Prótese , Stents/efeitos adversos , Artéria Subclávia/cirurgia , Resultado do Tratamento
13.
Front Cardiovasc Med ; 9: 767503, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35360016

RESUMO

Objectives: Despite the outstanding success of the Fontan operation, it is a palliative procedure and a substantial number of patients experience late failure of the Fontan circulation. Clinical presentation and hemodynamic phenotypes of Fontan failure are considerably variable. While various parameters have been identified as risk factors for late Fontan failure, a feasible score to classify Fontan failure and possibly allow timely risk stratification is lacking. Here, we explored the possibility of developing a score based on hemodynamic, clinical and laboratory parameters to classify Fontan failure and mortality. Methods: We performed a retrospective study in our cohort of adult Fontan patients from two institutions [n = 198, median follow-up after Fontan 20.3 (IQR 15.6-24.3) years], identifying those patients with clinical Fontan failure (n = 52, 26.3%). Various hemodynamic, echocardiographic, laboratory and clinical data were recorded and differences between patients with and without Fontan failure were analyzed. We composed a Fontan Failure Score containing 15 parameters associated with Fontan failure and/or mortality and assessed its accuracy to discriminate between patients with and without late Fontan failure as well as late mortality and survival. Results: Late failure occurred at a median of 18.2 (IQR 9.1-21.1) years after Fontan completion. Mortality associated with Fontan failure was substantial (25/52, 48.1%) with freedom of death/transplantation/take-down of 64% at 5 years and 36% at 10 years after onset of Fontan failure, respectively. Patients with Fontan failure had a significantly higher median Fontan Failure Score compared to non-failing Fontan patients [8 points (IQR 5-10) vs. 2 points (IQR 1-5), p < 0.001]. The score accurately classifies Fontan failure as well as mortality as assessed with receiver operating characteristic analysis. Area under the curve of the Fontan Failure Score was 0.963 (95% CI 0.921; 0.985, p < 0.001) to discriminate failure and 0.916 (95% CI 0.873; 0.959, p < 0.001) to classify mortality. Conclusion: We have developed an uncomplex yet remarkably accurate score to classify Fontan failure and late mortality in adult Fontan patients. Prospective validation and most likely refinement and calibration of the score in larger and preferably multi-institutional cohorts is required to assess its potential to predict the risk of Fontan failure and late mortality.

14.
Pediatr Cardiol ; 43(6): 1214-1222, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35149898

RESUMO

Several criteria to identify suitable candidates for anatomic repair in congenitally corrected transposition (cc-TGA) have been proposed. The purpose of this study was to critically re-evaluate adequacy of these recommendations in our patient cohort. All cc-TGA patients undergoing anatomic repair between 2010 and 2019 were reviewed. Evaluated eligibility criteria for repair included age ≤ 15 years, LV mass index ≥ 45-50 g/m2, LV mass/volume ratio > 0.9-1.5 and systolic LV to right ventricle pressure ratio > 70-90% among others. Repair failure was defined as postoperative early mortality or LV dysfunction requiring mechanical circulatory support. Twenty-five patients were included (median [interquartile range] age at surgery 1.8 years [0.7;6.6]; median postoperative follow-up 3.2 years [0.7;6.3]). Median preoperative LV ejection fraction was 60% [56;64], indexed LV mass 48.5 g/m2 [43.7;58.1] and LV mass/volume ratio 1.5 [1.1;1.6], respectively. A total of 12 patients (48%) did not meet at least one of the previously recommended criteria, however, all but two patients (92%) experienced favorable early outcome. Of 7 patients (28%) with indexed LV mass < 45 g/m2, 6 were successfully operated. There were two early repair failures (8%) with LV dysfunction: one patient died and one required mechanical circulatory support but recovered well. Surgery was performed successfully in patients with LV mass and volume Z-scores as low as - 2 and - 2.5, respectively. Anatomic correction for cc-TGA can be performed with excellent early outcome and is feasible even in patients with LV mass below previously recommended cut-offs. The use of LV mass and volume Z-scores might help to refine eligibility criteria.


Assuntos
Transposição dos Grandes Vasos , Adolescente , Transposição das Grandes Artérias Corrigida Congenitamente , Humanos , Lactente , Volume Sistólico , Resultado do Tratamento , Função Ventricular Esquerda
15.
Pediatr Cardiol ; 43(5): 1084-1093, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35084525

RESUMO

Double-chambered right ventricle (DCRV) is a progressive division of the right ventricular outflow tract (RVOT) often associated with a subaortic ventricular defect (VSD). The septation is caused by a mixture of hypertrophied muscle bundles and fibrous tissue, whereof the latter is of unclear pathogenesis. Our group has previously reported that flow disturbances lead to formation of fibroelastic tissue through a process called endothelial-to-mesenchymal transition (EndMT) but it is unclear whether the same mechanism exists in the RV. Tissue from patients undergoing repair of DCRV was examined to identify the histomorphological substrate of this tissue. Demographic and pre-/post-operative echocardiographic data were collected from nine patients undergoing surgery for DCRV. RVOTO tissue samples were histologically analyzed for myocardial hypertrophy, fibrosis, elastin content, and active EndMT (immunohistochemical double-staining for endothelial and mesenchymal markers and transcription factors Slug/Snail) and compared to four healthy controls. Indication for surgery were symptoms and progressive RVOT gradients. A highly turbulent flow jet through the RVOTO and VSD was observed in all patients with a preoperative median RVOT peak gradient of 77 mmHg (IQR 55.0-91.5), improved to 6 mmHg (IQR 4.5-17) postoperatively. Histological analysis revealed muscle and thick infiltratively growing fibroelastic tissue. EndMT was confirmed as underlying patho-mechanism of this fibroelastic tissue but the degree of myocardial hypertrophy was not different compared to controls (P = 0.08). This study shows for the first time that an invasive fibroelastic remodeling processes of the endocardium into the underlying myocardium through activation of EndMT contributes to the septation of the RVOT.


Assuntos
Comunicação Interventricular , Ventrículos do Coração , Cardiomegalia , Ecocardiografia , Endocárdio/patologia , Comunicação Interventricular/cirurgia , Ventrículos do Coração/cirurgia , Humanos , Miocárdio/patologia
16.
Horm Behav ; 137: 104937, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-33516727

RESUMO

In the phase between ovulation and potential implantation of the egg, and especially during pregnancy, females downregulate their immune system to prevent it from attacking the (future) embryo, which is after all a half-foreign organism. Yet this adaptive mechanism, that is set off by rising progesterone, makes females more vulnerable to pathogens at those critical times. It has been proposed that, to compensate this depression of physiological immunity, progesterone reinforces behavioral immunity-by increasing proneness to disgust and hence active avoidance of infection-but evidence is inconclusive and indirect. Manipulating progesterone directly, a recent, crucial study on female mice's disgust for infected males came up empty handed. Here, reanalyzing these data in a more statistically sensitive manner, we show that progesterone not only raises disgust but does so in a way that is both significant and substantial.


Assuntos
Asco , Animais , Feminino , Sistema Imunitário , Masculino , Camundongos , Gravidez , Progesterona/farmacologia
17.
Pediatr Cardiol ; 43(4): 769-775, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-34902048

RESUMO

Coronary artery lesions represent rare conditions in pediatric congenital heart disease and mainly include coronary artery stenoses (CAS) or coronary artery fistulae (CAF). Due to the small vessel size, pediatric percutaneous coronary interventions (PCI) are demanding and studies concerning long-term results are missing. In this retrospective study, we analyzed indications, procedural details, and post-procedural outcomes in pediatric patients who underwent PCI in our institution. For CAS treatment, procedural success was defined as efficient coronary revascularization with a significant improvement of coronary perfusion. CAF treatment was considered successful, when no residual shunt was detectable. From 1995 to 2020, 32 pediatric patients aged ≤ 18 years received interventional treatment for CAS (n = 24/32) or CAF (n = 8/32). Reasons for CAS were post-surgical (n = 15/24) or post-transplant (n = 9/24). Interventional treatment strategies included coronary angioplasty (20/43), stent placement (10/43), and a combination of both (13/43). In-hospital mortality occurred in 6/24 patients and late mortality in 5/24 patients leading to an overall 5-year survival of 62.5%. Early mortality mainly occurred due to post-ischemic myocardial failure. CAF occlusion was performed using coil embolization (n = 3), placement of vascular plugs (n = 3), a combination of both (n = 1), or a combination of coil embolization and a covered stent (n = 1). Treatment of coronary fistulae was successful in all patients with excellent post-procedural results and no follow-up death. PCI in pediatric patients with congenital heart disease can be performed safely and effectively. However, the overall 5-year survival probability of patients with CAS is reduced due to severe ischemic myocardial damage.


Assuntos
Angioplastia Coronária com Balão , Doença da Artéria Coronariana , Estenose Coronária , Cardiopatias Congênitas , Intervenção Coronária Percutânea , Angioplastia Coronária com Balão/métodos , Criança , Angiografia Coronária , Seguimentos , Cardiopatias Congênitas/cirurgia , Humanos , Intervenção Coronária Percutânea/métodos , Estudos Retrospectivos , Resultado do Tratamento
19.
J Interv Cardiol ; 2022: 3476398, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36684829

RESUMO

Background: Nowadays, transcatheter device closure of an atrial septal defect (ASD) is a standard approach in children. Potential early and long-term side effects or complications related to the metal framework of the devices are a known issue. A bioresorbable device such as the Carag Bioresorbable Septal Occluder™ (CBSO) could resolve such complications. Material and Results. The Carag Bioresorbable Septal Occluder™ (CBSO; Carag AG, Baar, Switzerland) is a self-centering double disk, repositionable, and retractable device with a bioresorbable framework (polylactic-co-glycolic acid), which is almost completely resorbed by 18-24 months postimplantation. This manuscript reports the four first-in-child ASD device closures using a CBSO. The patients' age was median (IQ1-IQ3), 4.5 years (4-7.25). Weight was 21.3 kg (17.6-32.7). We demonstrated procedural feasibility and safety. Effective defect closure with the device was 100%. Echocardiographic measurements of the thickness of the interatrial septum did not show any relevant increase over a 12-monthfollow-up period. There were no residual defects found after the procedure or later during the resorption process. The patients showed no evidence of any local or systemic inflammatory reaction. Conclusions: The CBSO device system could offer a new treatment option for transcatheter ASD device closure in the pediatric and adult fields. In our first-in-child experience, it was effectively and safely implanted. During the first 12 months of follow-up, no complications occurred.


Assuntos
Septo Interatrial , Comunicação Interatrial , Dispositivo para Oclusão Septal , Adulto , Criança , Humanos , Implantes Absorvíveis , Comunicação Interatrial/cirurgia , Ecocardiografia , Suíça , Cateterismo Cardíaco/métodos , Resultado do Tratamento , Seguimentos , Ecocardiografia Transesofagiana
20.
Int J Cardiol ; 344: 87-94, 2021 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-34563595

RESUMO

BACKGROUND: The Fontan operation is a palliative procedure and a substantial number of patients eventually experiences late Fontan circulation failure. Previous concepts of Fontan failure implicate increasing pulmonary vascular resistance (PVR) as a key contributor to late circulatory failure. However, data to support this assumption are sparse. We sought to characterize longitudinal hemodynamic and echocardiographic findings in adult failing Fontan patients. METHODS: We performed a retrospective cohort study in adult Fontan patients, identifying patients with Fontan failure. Hemodynamic, echocardiographic and clinical data were recorded. RESULTS: Of 173 adult patients (median follow-up after Fontan 20.2 years [IQR 15.7-24.3]), 48 (28%) showed signs of clinical Fontan failure. Thirty-seven patients (77.1%) exhibited ventricular dysfunction (systolic dysfunction defined by ejection fraction ≤45%, n = 22, or diastolic dysfunction defined by systemic ventricular end-diastolic pressure (SVEDP) ≥12 mmHg, n = 15). Elevated indexed PVR (≥2.5 WU*m2) was only observed in 9 (18.8%) patients. Ejection fraction declined from 60% [IQR 55-65] to 47% [IQR 35-55] during follow-up (p < 0.001). Mean pulmonary artery pressure and SVEDP increased from 11 mmHg [IQR 9-15] to 15 mmHg [IQR 12-18] and from 7 mmHg [IQR 4-10] to 11 mmHg [IQR 8-15] (both p < 0.001), respectively, while indexed PVR did not change significantly (2.1 [IQR 1.1-2.4] vs. 1.7 [IQR 1.1-2.5] WU*m2, p = 0.949). Fontan failure-associated mortality during follow-up was substantial (23/48; 48%). CONCLUSIONS: Systolic and diastolic ventricular dysfunction are frequent features in late Fontan failure in adults, while increases in PVR were rarely observed. The intricate interplay between hemodynamic compromises in Fontan failure deserves further research to optimize treatment strategies and outcome.


Assuntos
Técnica de Fontan , Cardiopatias Congênitas , Adulto , Técnica de Fontan/efeitos adversos , Cardiopatias Congênitas/diagnóstico por imagem , Cardiopatias Congênitas/cirurgia , Ventrículos do Coração/cirurgia , Humanos , Estudos Retrospectivos , Função Ventricular
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA