Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 65
Filtrar
1.
Quant Imaging Med Surg ; 12(3): 1871-1881, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-35284263

RESUMO

Background: Systemic lung cancer treatment-induced changes in bone marrow attenuation assessed via dual-energy CT-based virtual non-calcium (VNCa) imaging of the axial skeleton and their relationship to hematological laboratory have not yet been investigated. Methods: VNCa bone marrow images of the axial skeleton derived from 93 unenhanced reduced dose dual-energy CTs of the thorax and abdomen of 31 patients were retrospectively analyzed. Each patient had received one pre-therapy baseline exam and two consecutive follow-up exams (FU1 and FU2) at a mean of 7.7 and 11.7 weeks after start of therapy. Concurrent hematologic laboratory data were available for every exam. Seven regions of interest were placed in the spine and pelvis and mean VNCa bone marrow attenuation was measured. Twenty-two Patients receiving highly myelotoxic treatment (Group A) were compared to 9 patients receiving less toxic substances (Group B). Results: Median bone marrow attenuation in Group A/Group B was -31.8 HU (IQR 12.7)/40.6 HU (IQR, 12.2) at baseline, -46.5 HU (IQR, 12.5)/-43.8 HU (15.7) at FU1 and -46.9 HU (IQR, 22.0)/-38.5 HU (IQR, 18.5) at FU2. In both subgroups the reduction of the mean attenuation between baseline and FU1 was statistically significant although in Group A it was more pronounced; no significant difference was found between FU1 and FU2. The differences between Groups were not statistically significant. Leukopenia rates at FU1 and FU 2 were 50% and 54.5% in Group A and 0% and 22% in Group B. Anemia rates rose from 31.8% at baseline to 90% at FU1 and 86.4% at FU2 in Group A and fell from 77.8% at baseline to 66.7% at FU1 and further to 55.6% at FU2 in Group B. Conclusions: Both highly myelotoxic as well as-to a smaller degree-less myelotoxic systemic therapy led to a significant drop in bone marrow attenuation with no significant tendency towards subsequent elevation irrespective of the treatment's degree of toxicity or the presence of myelosuppression and not even under hematological supportive therapy. The results suggest that in this clinical setting an increase in bone marrow attenuation should be regarded as suspicious for tumor infiltration.

2.
Acad Radiol ; 29(2): 245-254, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-33707044

RESUMO

RATIONALE AND OBJECTIVES: To assess focal multiple myeloma bone lesions via dual-energy CT-based virtual noncalcium (VNCa) bone marrow imaging in relation to the overall hematological disease status and MRI findings. MATERIALS AND METHODS: We retrospectively evaluated 103 focal osteolytic lesions of the axial skeleton in VNCa bone marrow images of 32 patients. Region of interest-based attenuation measurements were correlated with T1w signal intensity and apparent diffusion coefficient (ADC). Results were compared between patients in active and inactive disease. Receiver operating characteristic analysis was performed to determine a cut-off value of VNCa attenuation for differentiation between the two groups. Standard of reference was the overall disease status according to International Myeloma Working Group response criteria. RESULTS: Mean attenuation difference between lesions and background bone marrow was significantly lower in inactive disease (16 HU, SD 30) compared to active disease (35 HU, SD 29). VNCa attenuation measurement allowed for differentiation between active and inactive disease with a sensitivity of 92% and a specificity of 58% at a cut-off value of -21 HU. VNCa attenuation was negatively correlated to T1w signal intensity (Spearman's ρ -0.617, p < 0.001) and positively correlated to ADC (Spearman's ρ 0.521, p < 0.001). CONCLUSION: Quantitative assessment of attenuation of focal osteolytic lesions in VNCa bone marrow images allows differentiation between overall active and inactive disease with higher attenuation signifying an increasing likelihood of active disease. This is supported by a significant positive correlation between the attenuation and the ADC, as well as a corresponding inverse correlation to T1w signal intensity.


Assuntos
Mieloma Múltiplo , Medula Óssea/diagnóstico por imagem , Humanos , Imageamento por Ressonância Magnética , Mieloma Múltiplo/diagnóstico por imagem , Estudos Retrospectivos , Sensibilidade e Especificidade , Tomografia Computadorizada por Raios X
4.
Eur J Radiol ; 139: 109725, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33878568

RESUMO

PURPOSE: Purpose of this study was to investigate Dual-energy CT (DECT) derived virtual non-calcium (VNCa) values for absolute quantification of the bone marrow composition in the wrist. MATERIALS AND METHODS: We prospectively included consecutive adult participants and examined their wrists with DECT. Ranges of VNCa and calcium values were measured in the carpal bones, radius and ulna using a semi-automatic method. Bones with bone marrow edema, assessed by two blinded radiologists, were excluded. After determining optimum parameters for the three-material decomposition, the influence of calcium values, age and sex on VNCa values was assessed using multiple linear regression. RESULTS: 41 participants (Median age 53 years, range 20 years - 88 years, 51 % men) were enrolled and 399 bones assessed. At participant level mean VNCa values were -143 HU (SD 14 HU) using the current parameters for three-material decomposition and -104HU (SD 11 HU) with optimized parameters. There was a strong and significant influence of calcium values on VNCa values with the current parameters (p < 0.001, -0.137 HU[VNCa] / HU[Calcium]). With optimized parameters the calcium values and sex were not statistically significant predictors of VNCa values. Age was a significant, but clinically negligible, predictor (p = 0.03, -0.225 HU / year). CONCLUSIONS: After optimizing three-material decomposition parameters, calcium values, age and sex do not substantially influence virtual non-calcium values, and DECT may therefore be used for absolute quantification of the bone marrow composition - alleviating the need for reference bones or groups.


Assuntos
Medula Óssea , Punho , Adulto , Medula Óssea/diagnóstico por imagem , Feminino , Humanos , Imageamento por Ressonância Magnética , Masculino , Sensibilidade e Especificidade , Tomografia Computadorizada por Raios X , Adulto Jovem
5.
Abdom Radiol (NY) ; 46(5): 2079-2089, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33159558

RESUMO

PURPOSE: To compare noise texture and accuracy to differentiate uric acid from non-uric acid urinary stones among four different single-source and dual-source DECT approaches in an ex vivo phantom study. METHODS: Thirty-two urinary stones embedded in gelatin were mounted on a Styrofoam disk and placed into a water-filled phantom. The phantom was imaged using four different DECT approaches: (A) dual-source DECT (DS-DE); (B) 1st generation split-filter single-source DECT (SF1-TB); (C) 2nd generation split-filter single-source DECT (SF2-TB) and (D) 2nd generation split-filter single-source DECT using serial acquisitions (SF2-TS). Two different radiation doses (3 mGy and 6 mGy) were used. Noise texture was compared by assessing the average spatial frequency (fav) of the normalized noise power spectrum (nNPS). ROC curves for stone classification were computed and the accuracy for different dual-energy ratio cutoffs was derived. RESULTS: NNPS demonstrated comparable noise texture among A, C, and D (fav-range 0.18-0.19) but finer noise texture for B (fav = 0.27). Stone classification showed an accuracy of 96.9%, 96.9%, 93.8%, 93.8% for A, B, C, D for low-dose, respectively, and 100%, 96.9%, 96.9%, 100% for routine dose. The vendor-specified cutoff for the dual-energy ratio was optimal except for the low-dose scan in D for which the accuracy was improved from 93.8 to 100% using an optimized cutoff. CONCLUSION: Accuracy to differentiate uric acid from non-uric acid stones was high among four single-source and dual-source DECT approaches for low- and routine dose DECT scans. Noise texture differed only slightly for the first-generation split-filter approach.


Assuntos
Cálculos Urinários , Urolitíase , Humanos , Imagens de Fantasmas , Tomografia Computadorizada por Raios X , Ácido Úrico , Cálculos Urinários/diagnóstico por imagem
6.
Int J Cardiovasc Imaging ; 36(10): 2051-2059, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32506286

RESUMO

To compare intravenous contrast material (CM) injection protocols for dual-energy CT pulmonary angiography (CTPA) in patients with suspected acute pulmonary embolism with regard to image quality and pulmonary perfused blood volume (PBV) values. A total of 198 studies performed with four CM injection protocols varying in CM volume and iodine delivery rates (IDR) were retrospectively included: (A) 60 ml at 5 ml/s (IDR = 1.75gI/s), (B) 50 ml at 5 ml/s (IDR = 1.75gI/s), (C) 50 ml at 4 ml/s (IDR = 1.40gI/s), (D) 40 ml at 3 ml/s (IDR = 1.05gI/s). Image quality and PBV values at different resolution settings were compared. Pulmonary arterial tract attenuation was highest for protocol A (397 ± 110 HU; p vs. B = 0.13; vs. C = 0.02; vs. D < 0.001). CTPA image quality of protocol A was rated superior compared to protocols B and D by reader 1 (p = 0.01; < 0.001), and superior to protocols B, C and D by reader 2 (p < 0.001; 0.02; < 0.001). Otherwise, there were no significant differences in CTPA quality ratings. Subjective iodine map ratings did not vary significantly between protocols A, B, and C. Both readers rated protocol D inferior to all other protocols (p < 0.05). PBV values did not vary significantly between protocols A and B at resolution settings of 1, 4 and 10 (p = 0.10; 0.10; 0.09), while otherwise PBV values displayed a decreasing trend from protocol A to D (p < 0.05). Higher CM volume and IDR are associated with superior CTPA and iodine map quality and higher absolute PBV values.


Assuntos
Angiografia por Tomografia Computadorizada , Meios de Contraste/administração & dosagem , Iopamidol/análogos & derivados , Artéria Pulmonar/diagnóstico por imagem , Embolia Pulmonar/diagnóstico por imagem , Administração Intravenosa , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Iopamidol/administração & dosagem , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Artéria Pulmonar/fisiopatologia , Embolia Pulmonar/fisiopatologia , Reprodutibilidade dos Testes , Estudos Retrospectivos
7.
Eur Radiol ; 30(8): 4295-4305, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32242275

RESUMO

OBJECTIVES: Previous studies have shown that split-bolus protocols in virtual non-contrast (VNC) reconstructions of dual-energy computed tomography (DE-CT) significantly decrease radiation dose in patients with urinary stone disease. To evaluate the impact on kidney stone detection rate of stone composition, size, tube voltage, and iodine concentration for VNC reconstructions of DE-CT. METHODS: In this prospective study, 16 kidney stones of different sizes (1.2-4.5 mm) and compositions (struvite, cystine, whewellite, brushite) were placed within a kidney phantom. Seventy-two scans with nine different iodine contrast agents/saline solutions with increasing attenuation (0-1400 HU) and different kilovoltage settings (70 kV/150 kV; 80 kV/150 kV; 90 kV/150 kV; 100 kV/150 kV) were performed. Two experienced radiologists independently rated the images for the presence and absence of stones. Multivariate classification tree analysis and descriptive statistics were used to evaluate the diagnostic performance. RESULTS: Classification tree analysis revealed a higher detection rate of renal calculi > 2 mm in size compared with that of renal calculi < 2 mm (84.7%; 12.7%; p < 0.001). For stones with a diameter > 2 mm, the best results were found at 70 kV/Sn 150 kV and 80 kV/Sn 150 kV in scans with contrast media attenuation of 600 HU or less, with sensitivity of 99.6% and 96.0%, respectively. A higher luminal attenuation (> 600 HU) resulted in a significantly decreased detection rate (91.8%, 0-600 HU; 70.7%, 900-1400 HU; p < 0.001). In our study setup, the detection rates were best for cystine stones. CONCLUSION: Scan protocols in DE-CT with lower tube current and lower contrast medium attenuation show excellent results in VNC for stones larger than 2 mm but have limitations for small stones. KEY POINTS: • The detection rate of virtual non-contrast reconstructions is highly dependent on the surrounding contrast medium attenuation at the renal pelvis and should be kept as low as possible, as at an attenuation higher than 600 HU the VNC reconstructions are susceptible to masking ureteral stones. • Protocols with lower tube voltages (70 kV/Sn 150 kV and 80 kV/Sn 150 kV) improve the detection rate of kidney stones in VNC reconstructions. • The visibility of renal stones in virtual non-contrast of dual-energy CT is highly associated with the size, and results in a significantly lower detection rate in stones below 2 mm.


Assuntos
Meios de Contraste , Processamento de Imagem Assistida por Computador/métodos , Cálculos Renais/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Oxalato de Cálcio , Fosfatos de Cálcio , Cistina , Humanos , Iodo , Imagens de Fantasmas , Estudos Prospectivos , Doses de Radiação , Estruvita , Cálculos Urinários
8.
Eur Radiol Exp ; 3(1): 46, 2019 12 04.
Artigo em Inglês | MEDLINE | ID: mdl-31802305

RESUMO

BACKGROUND: We investigated the influence of dose, spectral separation, pitch, rotation time, and reconstruction kernel on accuracy and image noise of virtual non-calcium images using a bone marrow phantom. METHODS: The phantom was developed at our institution and scanned using a third-generation dual-source dual-energy CT scanner at five different spectral separations by varying the tube-voltage combinations (70 kV/Sn150 kV, 80 kV/Sn150 kV, 90 kV/Sn150 kV, and 100 kV/Sn150 kV, all with 0.6-mm tin filter [Sn]; 80 kV/140 kV without tin filter) at six different doses (volume computed tomography dose index from 1 to 80 mGy). In separate experiments, rotation times, pitch, and reconstruction kernels were varied at a constant dose and tube voltage. Accuracy was determined by measuring the mean error between virtual non-calcium values in the fluid within and outside of the bone. Image noise was defined as the standard deviation of virtual non-calcium values. RESULTS: Spectral separation, dose, rotation time, or pitch did not significantly correlate (p > 0.083) with mean error. Increased spectral separation (rs-0.96, p < 0.001) and increased dose (rs-0.98, p < 0.001) correlated significantly with decreased image noise. Increasing sharpness of the reconstruction kernel correlated with mean error (rs 0.83, p = 0.015) and image noise (rs 1.0, p < 0.001). CONCLUSIONS: Increased dose and increased spectral separation significantly lowered image noise in virtual non-calcium images but did not affect the accuracy. Virtual non-calcium reconstructions with similar accuracy and image noise could be achieved at a lower tube-voltage difference by increasing the dose.


Assuntos
Medula Óssea/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Imagens de Fantasmas , Estudos Prospectivos , Tomografia Computadorizada por Raios X/instrumentação
9.
BMC Urol ; 19(1): 29, 2019 Apr 30.
Artigo em Inglês | MEDLINE | ID: mdl-31039768

RESUMO

BACKGROUND: We analysed in vitro the appearance of commonly used ureteral stents with dual-energy computed tomography (DECT) and we used these characteristics to optimize the differentiation between stents and adjacent stone. METHODS: We analysed in vitro a selection of 36 different stents from 7 manufacturers. They were placed in a self-build phantom model and measured using the SOMATOM® Force Dual Source CT-Scanner (Siemens, Forchheim, Germany). Each sample was scanned at various tube potentials of 80 and 150 peak kilovoltage (kVp), 90 and 150 kVp and 100 and 150 kVp. The syngo Post-Processing Suite software program (Siemens, Forchheim, Germany) was used for differentiation based on a 3-material decomposition algorithm (UA, calcium, urine) according to our standard stone protocol. RESULTS: Stents composed of polyurethane appeared blue and silicon-based stents were red on the image. The determined appearances were constant for various peak kilovoltage (kVp) values. The coloured stent-stone-contrast displayed on DECT improves monitoring, especially of small calculi adjacent to indwelling ureteral stents. CONCLUSION: Both urinary calculi and ureteral stents can be accurately differentiated by a distinct appearance on DECT. For the management of urolithiasis patients can be monitored more easily and accurately using DECT if the stent shows a different colour than the adjacent stone.


Assuntos
Cor , Gerenciamento Clínico , Imagens de Fantasmas/normas , Stents/normas , Tomografia Computadorizada por Raios X/normas , Urolitíase/diagnóstico por imagem , Humanos , Cálculos Renais/diagnóstico por imagem , Cálculos Renais/cirurgia , Tomografia Computadorizada por Raios X/instrumentação , Urolitíase/cirurgia
10.
Korean J Radiol ; 20(2): 283-294, 2019 02.
Artigo em Inglês | MEDLINE | ID: mdl-30672168

RESUMO

OBJECTIVE: To compare quantitative and qualitative image quality parameters in pediatric abdominopelvic dual-energy CT (DECT) using noise-optimized virtual monoenergetic image (VMI) and conventional VMI at different kiloelectron volt (keV) levels. MATERIALS AND METHODS: Thirty-six consecutive abdominopelvic DECT scans were retrospectively included. Noise-optimized VMI and conventional VMI were reconstructed at seven energy levels, from 40 keV to 100 keV at 10 keV intervals. The contrast-to-noise ratio (CNR) and signal-to-noise ratio (SNR) of the liver, pancreas, and aorta were objectively measured and compared. Image quality was evaluated subjectively regarding image noise, image blurring of solid organ, bowel image quality and severity of beam-hardening artifacts. Optimal monoenergetic levels in keV for both algorithms were determined based on overall image quality score. RESULTS: The maximal CNR and SNR values for all investigated organs were observed at 40 keV in noise-optimized VMI (CNR and SNR of liver, pancreas, aorta in order [CNR; 20.93, 17.34, 46.75: SNR; 37.39, 33.80, 63.21]), at 60-70 keV and at 70 keV in conventional VMI (CNR; 8.12, 5.67, 15.97: SNR; 19.57, 16.66, 26.65). In qualitative image analysis, noise-optimized VMI and conventional VMI showed the best overall image quality scores at 60 keV and at 70 keV, respectively. Noise-optimized VMI at 60 keV showed superior CNRs, SNRs, and overall image quality scores compared to conventional VMI at 70 keV (p < 0.001). CONCLUSION: Optimal energy levels for noise-optimized VMI and conventional VMI were 60 keV and at 70 keV, respectively. Noise-optimized VMI shows superior CNRs, SNRs and subjective image quality over conventional VMI, at the optimal energy level.


Assuntos
Aorta/diagnóstico por imagem , Fígado/diagnóstico por imagem , Pâncreas/diagnóstico por imagem , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Tomografia Computadorizada por Raios X/métodos , Adolescente , Algoritmos , Criança , Pré-Escolar , Feminino , Humanos , Lactente , Masculino , Estudos Retrospectivos , Razão Sinal-Ruído
11.
Eur Radiol ; 29(6): 2868-2877, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-30406312

RESUMO

OBJECTIVES: To retrospectively quantify liver iron content in haematological patients suspected of transfusional haemosiderosis using dual-energy CT (DECT) and correlate with serum ferritin levels and estimated quantity of transfused iron. METHODS: One hundred forty-seven consecutive dual-source dual-energy non-contrast chest-CTs in 110 haematologic patients intended primarily for exclusion of pulmonary infection between September 2016 and June 2017 were retrospectively evaluated. Image data was post-processed with a software prototype. After material decomposition, an iron enhancement map was created and freehand ROIs were drawn including most of the partially examined liver. The virtual iron content (VIC) was calculated and expressed in milligram/millilitre. VIC was correlated with serum ferritin and estimated amount of transfused iron. Scans of patients who had not received blood products were considered controls. RESULTS: Forty-eight (32.7%) cases (controls) had not received any blood transfusions whereas 67.3% had received one transfusion or more. Median serum ferritin and VIC were 138.0 µg/dl (range, 6.0-2628.0 µg/dl) and 1.33 mg/ml (range, - 0.94-7.56 mg/ml) in the post-transfusional group and 27.0 µg/dl (range, 1.0-248.0 µg/dl) and 0.61 mg/ml (range, - 2.1-2.4) in the control group. Correlation between serum ferritin and VIC was strong (r = 0.623; p < 0.001) as well as that between serum ferritin and estimated quantity of transfused iron (r = 0.681; p < 0.001). CONCLUSIONS: Hepatic VIC obtained via dual-energy chest-CT examinational protocol strongly correlates with serum ferritin levels and estimated amount of transfused iron and could therefore be used in the routine diagnosis for complementary evaluation of transfusional haemosiderosis. KEY POINTS: • Virtual liver iron content was measured in routine chest-CTs of haematological patients suspected of having iron overload. Chest-CTs were primarily intended for exclusion of pulmonary infection. • Measurements correlate strongly with the most widely used blood marker of iron overload serum ferritin (after exclusion of infection) and the amount of transfused iron. • Liver VIC could be used for supplemental evaluation of transfusional haemosiderosis in haematological patients.


Assuntos
Sobrecarga de Ferro/diagnóstico , Ferro/metabolismo , Fígado/metabolismo , Tomografia Computadorizada por Raios X/métodos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Biomarcadores/metabolismo , Feminino , Humanos , Sobrecarga de Ferro/metabolismo , Fígado/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Adulto Jovem
12.
Radiol Clin North Am ; 56(4): 497-506, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-29936943

RESUMO

Dual-energy computed tomography (CT) is an imaging technique in which the same axial slice of the patient is scanned with two different X-ray spectra in order to extract chemical information or improve diagnostic image quality. This method is useful for the detection or visualization of heavy atoms like iodine but the differentiation of soft tissue types containing only light atoms is usually not markedly improved compared with single-energy CT. The commercially available dual-energy CT scanners use different technological approaches that differ in complexity and result quality.


Assuntos
Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Tomografia Computadorizada por Raios X/métodos , Humanos
13.
Eur Radiol ; 28(12): 5083-5090, 2018 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-29882069

RESUMO

OBJECTIVES: Bone marrow imaging patterns in patients with multiple myeloma possess prognostic and potential therapeutic relevance. We aim to evaluate whether different magnetic resonance imaging (MRI) patterns also result in different bone marrow dual-energy computed tomography (DECT) virtual non-calcium (VNCa) attenuation values. METHODS: The institutional review board approved this study. Written informed consent was obtained from all participants. 53 patients with plasma cell disorders (24 with normal imaging pattern, 24 with focal infiltration, 5 with diffuse infiltration) and 21 control subjects sequentially underwent DECT and MRI of the axial skeleton. MRI served as reference standard for imaging pattern assessment. Bone marrow VNCa attenuation numbers were obtained according to pattern allocation. Generalised estimating equations and a receiver operating characteristic (ROC) analysis were performed. RESULTS: Mean VNCa attenuation numbers in patients with normal, focal and diffuse imaging patterns were - 65.8 HU, 3.3 HU and - 13.3 HU, respectively. We found significant differences between diffuse vs. normal (p < 0.001), diffuse vs. focal (p = 0.002) and normal vs. focal (p < 0.001) patterns. A cut-off of - 35.7 HU showed a sensitivity of 100% (24/24) and specificity of 97% (116/120) for the identification of a diffuse pattern vs. normal pattern, with an area under the ROC curve of 0.997. CONCLUSIONS: Bone marrow VNCa attenuation numbers of various imaging patterns in patients with plasma cell disorders differ significantly and a diffuse imaging pattern can be determined confidently using DECT, when ROIs are carefully selected on the basis of MRI findings. KEY POINTS: • DECT allows for imaging pattern allocation similar to MRI. • Bone marrow VNCa attenuation numbers differ significantly depending on the imaging pattern. • A diffuse imaging pattern can be determined confidently using DECT.


Assuntos
Medula Óssea/diagnóstico por imagem , Mieloma Múltiplo/diagnóstico , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Imageamento por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Curva ROC , Reprodutibilidade dos Testes
14.
Eur Radiol ; 28(8): 3405-3412, 2018 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-29460070

RESUMO

OBJECTIVES: To compare image quality and radiation dose of abdominal split-filter dual-energy CT (SF-DECT) combined with monoenergetic imaging to single-energy CT (SECT) with automatic tube voltage selection (ATVS). METHODS: Two-hundred single-source abdominal CT scans were performed as SECT with ATVS (n = 100) and SF-DECT (n = 100). SF-DECT scans were reconstructed and subdivided into composed images (SF-CI) and monoenergetic images at 55 keV (SF-MI). Objective and subjective image quality were compared among single-energy images (SEI), SF-CI and SF-MI. CNR and FOM were separately calculated for the liver (e.g. CNRliv) and the portal vein (CNRpv). Radiation dose was compared using size-specific dose estimate (SSDE). Results of the three groups were compared using non-parametric tests. RESULTS: Image noise of SF-CI was 18% lower compared to SEI and 48% lower compared to SF-MI (p < 0.001). Composed images yielded higher CNRliv over single-energy images (23.4 vs. 20.9; p < 0.001), whereas CNRpv was significantly lower (3.5 vs. 5.2; p < 0.001). Monoenergetic images overcame this inferiority in CNRpv and achieved similar results compared to single-energy images (5.1 vs. 5.2; p > 0.628). Subjective sharpness was equal between single-energy and monoenergetic images and diagnostic confidence was equal between single-energy and composed images. FOMliv was highest for SF-CI. FOMpv was equal for SEI and SF-MI (p = 0.78). SSDE was significant lower for SF-DECT compared to SECT (p < 0.022). CONCLUSIONS: The combined use of split-filter dual-energy CT images provides comparable objective and subjective image quality at lower radiation dose compared to single-energy CT with ATVS. KEY POINTS: • Split-filter dual-energy results in 18% lower noise compared to single-energy with ATVS. • Split-filter dual-energy results in 11% lower SSDE compared to single-energy with ATVS. • Spectral shaping of split-filter dual-energy leads to an increased dose-efficiency.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Doses de Radiação , Radiografia Abdominal/métodos , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Estudos Retrospectivos , Razão Sinal-Ruído , Adulto Jovem
15.
Invest Radiol ; 53(3): 135-142, 2018 03.
Artigo em Inglês | MEDLINE | ID: mdl-28926370

RESUMO

PURPOSE: The purpose of this study was to evaluate image quality of a spectral photon-counting detector (PCD) computed tomography (CT) system for evaluation of major arteries of the head and neck compared with conventional single-energy CT scans using energy-integrating detectors (EIDs). METHODS: In this institutional review board-approved study, 16 asymptomatic subjects (7 men) provided informed consent and received both PCD and EID contrast-enhanced CT scans of the head and neck (mean age, 58 years; range, 46-75 years). Tube settings were (EID: 120 kVp/160 mA vs PCD: 140 kVp/108 mA) for all volunteers. Quantitative analysis included measurements of mean attenuation, image noise, and contrast-to-noise ratio (CNR). Spectral PCD data were used to reconstruct virtual monoenergetic images and iodine maps. A head phantom was used to validate iodine concentration measurements in PCD images only. Two radiologists blinded to detector type independently scored the image quality of different segments of the arteries, as well as diagnostic acceptability, image noise, and severity of artifacts of the PCD and EID images. Reproducibility was assessed with intraclass correlation coefficient. Linear mixed models that account for within-subject correlation of analyzed arterial segments were used. Linear regression and Bland-Altman analysis with 95% limits of agreement were used to calculate the accuracy of material decomposition. RESULTS: Photon-counting detector image quality scores were significantly higher compared with EID image quality scores with lower image noise (P < 0.01) and less image artifacts (P < 0.001). Photon-counting detector image noise was 9.1% lower than EID image noise (8.0 ± 1.3 HU vs 8.8 ± 1.5 HU, respectively, P < 0.001). Arterial segments showed artifacts on EID images due to beam hardening that were not present on PCD images. On PCD images of the head phantom, there was excellent correlation (R = 0.998) between actual and calculated iodine concentrations without significant bias (bias: -0.4 mg/mL [95% limits of agreements: -1.1 to 0.4 mg/mL]). Iodine maps had 20.7% higher CNR compared with nonspectral PCD (65.2 ± 9.0 vs 54.0 ± 4.5, P = 0.01), and virtual monoenergetic image at 70 keV showed similar CNR to nonspectral images (52.6 ± 4.2 vs 54.0 ± 4.5, P = 0.39). CONCLUSIONS: Photon-counting CT has the potential to improve the image quality of carotid and intracranial CT angiography compared with single-energy EID CT.


Assuntos
Encéfalo/irrigação sanguínea , Artérias Carótidas/anatomia & histologia , Circulação Cerebrovascular/fisiologia , Angiografia por Tomografia Computadorizada/métodos , Angiografia Coronária/métodos , Processamento de Imagem Assistida por Computador/métodos , Idoso , Encéfalo/anatomia & histologia , Encéfalo/fisiologia , Artérias Carótidas/fisiologia , Angiografia por Tomografia Computadorizada/instrumentação , Meios de Contraste , Angiografia Coronária/instrumentação , Feminino , Humanos , Iodo , Masculino , Pessoa de Meia-Idade , Imagens de Fantasmas , Fótons , Estudos Prospectivos , Intensificação de Imagem Radiográfica/métodos , Valores de Referência , Reprodutibilidade dos Testes
16.
Invest Radiol ; 53(2): 63-69, 2018 02.
Artigo em Inglês | MEDLINE | ID: mdl-28915161

RESUMO

PURPOSE: The aim of this study was to determine whether dual-energy computed tomography (DECT) imaging is superior to conventional noncontrast computed tomography (CT) imaging for the detection of acute ischemic stroke. MATERIALS AND METHODS: This was a retrospective, single-center study of 40 patients who presented to the emergency department (ED) of a major, acute care, teaching center with signs and symptoms of acute stroke. Only those patients who presented to the ED within 4 hours of symptom onset were included in this study. All 40 patients received a noncontrast DECT of the head at the time of presentation. Each patient also received standard noncontrast CT of the head 24 hours after their initial presentation to the ED. "Brain edema" images were then reconstructed using 3-material decomposition with parameters adjusted to suppress gray/white matter contrast while preserving edema and increasing its conspicuity. The initial unenhanced, mixed images, brain edema, and 24-hour follow-up true noncontrast (TNC) images were reviewed and assigned Alberta Stroke Program Early CT scores. Sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) were calculated. RESULTS: Of the 40 patients, 28 (70%) were diagnosed with an acute infarction. Brain edema reconstructions were better able to predict end infarction volume, with Alberta Stroke Program Early CT scores similar to the 24-hour follow-up TNC CT (7.75 vs 7.7; P > 0.05), whereas the mixed images routinely underestimated the extent of infarction (8.975 vs 7.7; P < 0.001). Initial TNC images had a sensitivity, specificity, PPV, and NPV of 80% (95% confidence interval [CI], 51.9%-95.7%), 72.7% (95% CI, 39%-94%), 80% (95% CI, 51.9%-95.7%), and 72.73% (95% CI, 51.91%-95.67%), respectively. The DECT brain edema images provided a sensitivity, specificity, PPV, and NPV of 93.33% (95% CI, 68.05%-99.83%), 100% (95% CI, 71.51%-100%), 100% (95% CI, 76.84%-100%), and 91.67% (95% CI, 61.52%-99.79%), respectively. There was very good interrater reliability across all 3 imaging techniques. CONCLUSION: Brain edema reconstructions are able to more accurately detect edema and end-infarct volume as compared with initial TNC images. This provides a better assessment of the degree and extent of infarction and may serve to better guide therapy in the future.


Assuntos
Edema Encefálico/diagnóstico por imagem , Acidente Vascular Cerebral/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Idoso , Idoso de 80 Anos ou mais , Encéfalo/diagnóstico por imagem , Edema Encefálico/complicações , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Imagem Radiográfica a Partir de Emissão de Duplo Fóton , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade , Acidente Vascular Cerebral/complicações
17.
Radiology ; 286(1): 205-213, 2018 01.
Artigo em Inglês | MEDLINE | ID: mdl-28799843

RESUMO

Purpose To determine the diagnostic performance of dual-energy computed tomography (CT) for detection of bone marrow (BM) infiltration in patients with multiple myeloma by using a virtual noncalcium (VNCa) technique. Materials and Methods In this prospective study, 34 consecutive patients with multiple myeloma or monoclonal gammopathy of unknown significance sequentially underwent dual-energy CT and magnetic resonance (MR) imaging of the axial skeleton. Two independent readers visually evaluated standard CT and color-coded VNCa images for the presence of BM involvement. MR imaging served as the reference standard. Analysis on the basis of the region of interest (ROI) of VNCa CT numbers of infiltrated (n = 75) and normal (n = 170) BM was performed and CT numbers were subjected to receiver operating characteristic analysis to calculate cutoff values. Results In the visual analysis, VNCa images had an overall sensitivity of 91.3% (21 of 23), specificity of 90.9% (10 of 11), accuracy of 91.2% (31 of 34), positive predictive value of 95.5% (21 of 22), and a negative predictive value of 83.3% (10 of 12). ROI-based analysis of VNCa CT numbers showed a significant difference between infiltrated and normal BM (P < .001). Receiver operating characteristic analysis revealed an area under the curve of 0.978. A cutoff of -44.9 HU provided a sensitivity of 93.3% (70 of 75), specificity of 92.4% (157 of 170), accuracy of 92.7% (227 of 245), positive predictive value of 84.3% (70 of 83), and negative predictive value of 96.9% (157 of 162) for the detection of BM infiltration. Conclusion Visual and ROI-based analyses of dual-energy VNCa images had excellent diagnostic performance for assessing BM infiltration in patients with multiple myeloma with precision comparable to that of MR imaging. © RSNA, 2017 Online supplemental material is available for this article.


Assuntos
Medula Óssea/diagnóstico por imagem , Mieloma Múltiplo/diagnóstico por imagem , Mieloma Múltiplo/patologia , Pelve/diagnóstico por imagem , Coluna Vertebral/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Idoso , Medula Óssea/patologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Pelve/patologia , Estudos Prospectivos , Curva ROC , Coluna Vertebral/patologia
18.
Phys Med Biol ; 63(1): 015012, 2017 12 14.
Artigo em Inglês | MEDLINE | ID: mdl-29057753

RESUMO

Dual energy CT (DECT) has been shown, in theoretical and phantom studies, to improve the stopping power ratio (SPR) determination used for proton treatment planning compared to the use of single energy CT (SECT). However, it has not been shown that this also extends to organic tissues. The purpose of this study was therefore to investigate the accuracy of SPR estimation for fresh pork and beef tissue samples used as surrogates of human tissues. The reference SPRs for fourteen tissue samples, which included fat, muscle and femur bone, were measured using proton pencil beams. The tissue samples were subsequently CT scanned using four different scanners with different dual energy acquisition modes, giving in total six DECT-based SPR estimations for each sample. The SPR was estimated using a proprietary algorithm (syngo.via DE Rho/Z Maps, Siemens Healthcare, Forchheim, Germany) for extracting the electron density and the effective atomic number. SECT images were also acquired and SECT-based SPR estimations were performed using a clinical Hounsfield look-up table. The mean and standard deviation of the SPR over large volume-of-interests were calculated. For the six different DECT acquisition methods, the root-mean-square errors (RMSEs) for the SPR estimates over all tissue samples were between 0.9% and 1.5%. For the SECT-based SPR estimation the RMSE was 2.8%. For one DECT acquisition method, a positive bias was seen in the SPR estimates, having a mean error of 1.3%. The largest errors were found in the very dense cortical bone from a beef femur. This study confirms the advantages of DECT-based SPR estimation although good results were also obtained using SECT for most tissues.


Assuntos
Osso e Ossos/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Prótons , Carne Vermelha/análise , Razão Sinal-Ruído , Tomografia Computadorizada por Raios X/métodos , Algoritmos , Animais , Humanos , Modelos Teóricos , Imagens de Fantasmas
19.
Acta Oncol ; 56(11): 1465-1471, 2017 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-28885130

RESUMO

PURPOSE: To evaluate the accuracy and precision across phantom size of a dual-energy computed tomography (DECT) technique used to calculate relative proton stopping power (SPR) in tissue-simulating materials and a silicone implant relative to conventional single-energy CT (SECT). MATERIAL AND METHODS: A 32 cm lateral diameter (CIRS model 062M, Norfolk, Virginia) electron density phantom containing inserts which simulated the chemical composition of eight tissues in a solid-water background was scanned using SECT and DECT. A liquid water insert was included to confirm CT number accuracy. All materials were also placed in four water tanks, ranging from 15 to 45 cm in lateral width and scanned using DECT and SECT. A silicone breast implant was scanned in the same water phantoms. SPR values were calculated based on commercial software (syngo CT Dual Energy, Siemens Healthcare GmbH) and compared to reference values derived from proton beam measurements. Accuracy and precision were quantified across phantom size using percent error and standard deviation. Graphical and regression analysis were used to determine whether SECT or DECT was superior in estimating SPR across phantom size. RESULTS: Both DECT and SECT SPR data resulted in good agreement with the reference values. Percent error was ±3% for both DECT and SECT in all materials except lung and dense bone. The coefficient of variation (CV) across materials and phantom sizes was 1.12% for SECT and 0.96% for DECT. Material-specific regression and graphical analysis did not reveal size dependence for either technique but did show reduced systematic bias with DECT for dense bone and liver. Mean percent error in SPR for the implant was reduced from 11.46% for SECT to 0.49% for DECT. CONCLUSIONS: We demonstrate the superior ability of DECT to mitigate systematic bias in bones and liver and estimate SPR in a silicone breast implant.


Assuntos
Neoplasias/radioterapia , Órgãos em Risco/efeitos da radiação , Imagens de Fantasmas , Prótons , Tomografia Computadorizada por Raios X/métodos , Relação Dose-Resposta à Radiação , Humanos
20.
Phys Med Biol ; 62(17): 7216-7232, 2017 Aug 21.
Artigo em Inglês | MEDLINE | ID: mdl-28726669

RESUMO

Photon-counting computed tomography (PCCT) uses a photon counting detector to count individual photons and allocate them to specific energy bins by comparing photon energy to preset thresholds. This enables simultaneous multi-energy CT with a single source and detector. Phantom studies were performed to assess the spectral performance of a research PCCT scanner by assessing the accuracy of derived images sets. Specifically, we assessed the accuracy of iodine quantification in iodine map images and of CT number accuracy in virtual monoenergetic images (VMI). Vials containing iodine with five known concentrations were scanned on the PCCT scanner after being placed in phantoms representing the attenuation of different size patients. For comparison, the same vials and phantoms were also scanned on 2nd and 3rd generation dual-source, dual-energy scanners. After material decomposition, iodine maps were generated, from which iodine concentration was measured for each vial and phantom size and compared with the known concentration. Additionally, VMIs were generated and CT number accuracy was compared to the reference standard, which was calculated based on known iodine concentration and attenuation coefficients at each keV obtained from the U.S. National Institute of Standards and Technology (NIST). Results showed accurate iodine quantification (root mean square error of 0.5 mgI/cc) and accurate CT number of VMIs (percentage error of 8.9%) using the PCCT scanner. The overall performance of the PCCT scanner, in terms of iodine quantification and VMI CT number accuracy, was comparable to that of EID-based dual-source, dual-energy scanners.


Assuntos
Radioisótopos do Iodo/análise , Imagens de Fantasmas , Fótons , Tomógrafos Computadorizados , Tomografia Computadorizada por Raios X/métodos , Contagem Corporal Total , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA