Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Materials (Basel) ; 15(7)2022 Apr 05.
Artigo em Inglês | MEDLINE | ID: mdl-35408005

RESUMO

A knitted implant, unilaterally modified with plasma-assisted chemical-vapor deposition (PACVD), and with a nano-layer of fluorine derivative supplementation, for reducing the risk of complications related to adhesions, and the formation of a thick postoperative scar was prepared. The biological evaluation of designed or modified medical devices is the main aspect of preclinical research. If such studies use a medical device with prolonged contact with connective tissue (more than 30 days), biocompatibility studies require a safety assessment in terms of toxicity in vitro and in vivo, allergenicity, irritation, and cancerogenicity, reproductive and developmental toxicity. The ultimate aspect of biological evaluation is biofunctionality, and evaluation of the local tissue response after implantation, resulting in the determination of all aspects of local biocompatibility with the implemented synthetic material. The implantation of PACVD-modified materials in muscle allows us to estimate the local irritation effect on the connective tissue, determining the risk of scar formation, whereas implantation of the above-mentioned knitted fabric into the abdominal wall, assists with evaluating the risk of fistula formation-the main post-surgical complications. The research aimed to evaluate the local reaction of the soft tissues after the implantation of the knitted implants modified with PACVD of the fluoropolymer in the nanostuctural form. The local effect that occurred during the implantation of the designed implants was quantitatively and qualitatively evaluated when PACVD unmodified (reference), and modified medical devices were implanted in the abdominal cavity (intra-abdominal position) for 12 or into the muscles for 56 weeks. The comparative semi-quantitative histological assessment included the severity of inflammatory cells (multinucleated cells, lymphocytes, plasma cells, macrophages, giant cells) and the tissue response (necrosis, neovascularization, fibrosis, and fat infiltration) on a five-point scale. The knitted implants modified by PACVD did not indicate cumulative tissue response when they were implanted in the muscle and intra-abdominally with direct contact with the viscera. They reduced local tissue reaction (score -2.71 after 56 weeks of the implantation) and internal organ adhesion (irritation score -2.01 and adhesion susceptibility -0.3 after 12 weeks of the implantation) compared with the reference (unmodified by PACVD) knitted implant, which had an identical structure and was made of the same source.

2.
Materials (Basel) ; 15(6)2022 Mar 21.
Artigo em Inglês | MEDLINE | ID: mdl-35329766

RESUMO

A high protection level without an excessive weight is a basic assumption in the design of modern armors and protection systems. Optimizing armors is a task of development of the utmost importance, and is the subject of the work contained within this article. Optimization of ballistic inserts was carried out using multicriterial analysis (MCA), which enables the selection of the optimal composition, taking into account properties such as ballistic resistance, physicomechanical, and/or functional properties. For this purpose, various types of composite systems were produced and tested in terms of their fragment-resistant properties according to STANAG 2920 and the composite areal density of different ballistic inserts: Soft inserts made of Twaron® para-aramid sheets, hard ballistic inserts made of multilayer hot-pressed preimpregnated sheets, and hybrid hard ballistic inserts prepared on the basis of multilayer hot-pressed preimpregnated sheets and ceramics. The application of MCA and performance of experimental fragment resistance tests for a wide spectrum of para-aramid inserts are part of the novelty of this work. The obtained test results showed that depending on the composition of the composite system, we could obtain a wide range of fragmentation resistance in the range of 300 to >1800 m/s, which depended on the areal density and type of composite system used. The results also confirmed that MCA is a good computational tool to select the optimal design of para-aramid ballistic inserts.

3.
Materials (Basel) ; 15(3)2022 Feb 02.
Artigo em Inglês | MEDLINE | ID: mdl-35161093

RESUMO

The following article describes a new type of textile signal line that can be used in smart clothing. The article presents the structure of this line and the materials used for its construction. The article also presents the results of research on the influence of the line tensile force on the value of its characteristic impedance. The above tests were carried out on lines where the electrically conductive paths do not have the form of straight lines, as is often the case in smart clothing. The article also presents a preliminary statistical analysis, the aim of which was to find those characteristics of the substrate of the line that affect changes in the characteristic impedance during stretching.

4.
Materials (Basel) ; 14(14)2021 Jul 20.
Artigo em Inglês | MEDLINE | ID: mdl-34300976

RESUMO

The presented research focuses on the concept of an advanced ballistic personal protection design, taking into account safety as well as performance requirements. The application of the multi-criterial analysis (MCA) allows for a comprehensive comparison of all the properties of materials and to select the optimal personal ballistic protection system, considering their mechanical and ballistic properties. The newly developed hybrid ballistic composites, consisting of two or three various components (variations of ballistic and/or non-ballistic textiles; hybrid ballistic plates-HBP), were evaluated via a multi-criterial analysis that considered a wide range of properties, describing behavior and safety usage, as well as the economical aspect of their fabrication.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA