Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Clin Vaccine Immunol ; 20(1): 46-51, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-23114696

RESUMO

Patients treated with erythropoietin-based erythropoiesis-stimulating agents (ESAs) can develop a rare but life-threatening condition called antibody-mediated pure red cell aplasia (amPRCA). The antibody characteristics in a nephrology patient with amPRCA include high antibody concentrations with neutralizing activity and a mixed IgG subclass including anti-ESA IgG4 antibodies. In contrast, anti-ESA IgG4 antibody is generally not detected in baseline samples and antibody-positive non-PRCA patients. Therefore, we validated a highly sensitive immunoassay on the ImmunoCAP 100 instrument to quantitate anti-ESA IgG4 antibodies using a human recombinant anti-epoetin alfa (EPO) IgG4 antibody as a calibrator. The biotinylated ESA was applied to a streptavidin ImmunoCAP, and bound anti-ESA IgG4 antibodies were detected using a ß-galactosidase-conjugated mouse anti-human IgG4 antibody. The validated assay was used to detect anti-ESA IgG4 in amPRCA and non-PRCA patients. The immunoassay detected 15 ng/ml of human anti-EPO IgG4 antibody in the presence of a 200 M excess of human anti-ESA IgG1, IgG2, or IgM antibody and tolerated 2 µg/ml of soluble erythropoietin. All patient samples with confirmed amPRCA had measurable anti-ESA IgG4 antibodies. In addition, 94% (17/18) of non-PRCA patient samples were antibody negative or had below 15 ng/ml of anti-ESA IgG4 antibodies. This novel immunoassay can measure low-nanogram quantities of human anti-ESA IgG4 antibodies in the presence of other anti-ESA antibodies. An increased concentration of anti-ESA IgG4 antibody is associated with the development of amPRCA. We propose that the measurement of anti-ESA specific IgG4 antibodies may facilitate early detection of amPRCA in patients receiving all ESAs structurally related to human erythropoietin.


Assuntos
Anticorpos Neutralizantes/sangue , Autoanticorpos/sangue , Técnicas de Laboratório Clínico/métodos , Eritropoetina/imunologia , Imunoglobulina G/sangue , Aplasia Pura de Série Vermelha/diagnóstico , Eritropoese/efeitos dos fármacos , Eritropoese/imunologia , Humanos , Imunoensaio/métodos , Sensibilidade e Especificidade
2.
J Immunol Methods ; 382(1-2): 129-41, 2012 Aug 31.
Artigo em Inglês | MEDLINE | ID: mdl-22634015

RESUMO

Recombinant human erythropoietin (EPO) has been used therapeutically for more than two decades in the treatment of anemia. Although EPO is generally well tolerated, in rare cases, patients have developed anti-EPO antibodies that can negatively impact safety and efficacy. Therefore, the detection of antibodies against EPO is a regulatory requirement during clinical development and post-approval. Although it is a rare phenomenon, antibody-mediated pure red cell aplasia (PRCA) is a serious complication than can result from antibodies that develop and neutralize EPO as well as endogenous erythropoietin. Currently, there are no universally accepted analytical methods to detect the full repertoire of binding and neutralizing anti-EPO antibodies. A number of different methods that differ in terms of antibodies detected and assay sensitivities are used by different manufacturers. There is also a lack of antibody reference reagents, and therefore no consistent basis for detecting and measuring anti-EPO antibodies. Reference reagents, with established ranges, are essential to monitor the safety and efficacy of all erythropoiesis-stimulating agents (ESAs) structurally related to human erythropoietin. This is the first report of the development and characterization of a panel of fully human antibodies against EPO suitable as reference reagents. The characteristics of antibodies within the panel were selected based on the prevalence of non-neutralizing IgG and IgM antibodies in non-PRCA patients and neutralizing IgG antibodies, including IgG1 and IgG4, in antibody-mediated PRCA subjects. The reference panel includes antibodies of high- and low-affinity with binding specificity to neutralizing and non-neutralizing erythropoietin epitopes. The subclass of human antibodies in this reference panel includes an IgG1, IgG2, and IgG4, as well as an IgM isotype. This antibody panel could help select appropriate immunogenicity assays, guide validation, and monitor assay performance. Further, this human anti-ESA antibody panel may help set the limits of each assay platform in terms of the full repertoire of the anti-ESA antibodies, and may facilitate standardization of ESA immunogenicity reporting across assay platforms.


Assuntos
Anticorpos/imunologia , Ensaio de Imunoadsorção Enzimática/métodos , Eritropoetina/imunologia , Hematínicos/imunologia , Animais , Ensaio de Imunoadsorção Enzimática/normas , Humanos , Camundongos , Camundongos Transgênicos , Proteínas Recombinantes/imunologia , Padrões de Referência , Sensibilidade e Especificidade
3.
Nephrol Dial Transplant ; 27(2): 688-93, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-21602184

RESUMO

BACKGROUND: The immunological methods for detecting antibodies to erythropoiesis-stimulating agents (ESAs) differ in assay sensitivity. However, this parameter, routinely determined in clinical assays using a high-affinity non-human polyclonal antibody, gives a one-dimensional assessment of antibody detection. We compare three widely used immunological methods and evaluate the ability of each to detect mature human antibodies and human antibodies characteristic of an early immune response. METHODS: The detection of anti-ESA antibodies was compared between a radioimmunoprecipitation (RIP) assay, an electrochemiluminescence (ECL) bridging enzyme-linked immunosorbent assay and a surface plasmon resonance (SPR)-based immunoassay. All three methods were validated for sensitivity, specificity and precision. Specimens from clinical studies or post market testing were categorized as pure red cell aplasia (PRCA) or non-PRCA and then analyzed in each method. RESULTS: Among the antibody-mediated PRCA samples, which contain high affinity neutralizing antibodies, there was strong correlation between all methods. The results from non-PRCA sample analysis show high correlation between RIP and ECL methods; however, differences between the SPR immunoassay and the ECL and RIP were demonstrated. The samples that scored positive in the SPR immunoassay and negative by RIP and ECL were characterized to be of low antibody concentration, contained a high percentage of rapidly dissociating antibodies, or were antibodies of the IgM isotype. CONCLUSIONS: All three immunological methods are appropriate for detection of antibodies associated with antibody-mediated PRCA. However, the SPR immunoassay platform detected an early, low affinity IgG and IgM antibody response as well as detected and characterized a pathogenic antibody response associated with antibody-mediated PRCA.


Assuntos
Anticorpos Anti-Idiotípicos/imunologia , Hematínicos/farmacologia , Ensaio de Radioimunoprecipitação/métodos , Aplasia Pura de Série Vermelha/imunologia , Ressonância de Plasmônio de Superfície/métodos , Anticorpos Anti-Idiotípicos/análise , Estudos de Casos e Controles , Ensaio de Imunoadsorção Enzimática , Feminino , Hematínicos/imunologia , Humanos , Imunoensaio/métodos , Masculino , Aplasia Pura de Série Vermelha/sangue , Reprodutibilidade dos Testes , Estudos de Amostragem , Sensibilidade e Especificidade
4.
Clin Immunol ; 137(1): 5-14, 2010 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-20708973

RESUMO

An immune response to a biotherapeutic can be induced when the therapeutic is processed and presented by antigen presenting cell to T helper cells. This study evaluates the performance of an in vitro assay that can elicit antigen specific effector T cell responses. Two biotherapeutics with known clinical immunogenicity [FPX1 and FPX2] were assessed for their ability to induce antigen-specific IFN-γ secreting T cells in peripheral blood mononuclear cells (PBMC). The 24 amino acid peptide component of FPX1 elicited an antigen-specific response in 16/34 (47%) individual naïve healthy donors. This in vitro effect was consistent with high rate of immunogenicity which was observed when this drug was administered in clinical trials. FPX2 did not induce antigen-specific T cells in vitro, which correlates with the low rate of development of anti-drug antibody responses to this molecule in the clinic. The assay has the potential to predict immunogenicity and help in the selection of biotherapeutics at the early development stage of a clinical candidate.


Assuntos
Terapia Biológica/efeitos adversos , Imunoensaio/métodos , Leucócitos Mononucleares/imunologia , Ativação Linfocitária/imunologia , Proteínas Recombinantes/imunologia , Linfócitos T/imunologia , Anticorpos/imunologia , Anticorpos/farmacologia , Anticorpos Monoclonais/imunologia , Formação de Anticorpos/imunologia , Técnicas de Cultura de Células , Sobrevivência Celular , Células Cultivadas , Antígenos HLA-DR/imunologia , Humanos , Fragmentos Fc das Imunoglobulinas/genética , Imunofenotipagem , Interferon gama/análise , Interferon gama/metabolismo , Leucócitos Mononucleares/metabolismo , Ativação Linfocitária/efeitos dos fármacos , Subpopulações de Linfócitos/citologia , Fragmentos de Peptídeos/imunologia , Peptídeos/genética , Peptídeos/imunologia , Fito-Hemaglutininas/farmacologia , Proteínas Recombinantes/uso terapêutico , Reprodutibilidade dos Testes , Linfócitos T/metabolismo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA