Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 93
Filtrar
1.
Heart Rhythm O2 ; 5(6): 403-416, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38984358

RESUMO

Proactive esophageal cooling for the purpose of reducing the likelihood of ablation-related esophageal injury resulting from radiofrequency (RF) cardiac ablation procedures is increasingly being used and has been Food and Drug Administration cleared as a protective strategy during left atrial RF ablation for the treatment of atrial fibrillation. In this review, we examine the evidence supporting the use of proactive esophageal cooling and the potential mechanisms of action that reduce the likelihood of atrioesophageal fistula (AEF) formation. Although the pathophysiology behind AEF formation after thermal injury from RF ablation is not well studied, a robust literature on fistula formation in other conditions (eg, Crohn disease, cancer, and trauma) exists and the relationship to AEF formation is investigated in this review. Likewise, we examine the abundant data in the surgical literature on burn and thermal injury progression as well as the acute and chronic mitigating effects of cooling. We discuss the relationship of these data and maladaptive healing mechanisms to the well-recognized postablation pathophysiological effects after RF ablation. Finally, we review additional important considerations such as patient selection, clinical workflow, and implementation strategies for proactive esophageal cooling.

2.
Eur Heart J Case Rep ; 8(7): ytae301, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38966596

RESUMO

Background: The hybrid convergent procedure is approved to treat symptomatic patients with long-standing persistent atrial fibrillation (AF). Despite direct visualization during surgical ablation as well as the use of luminal oesophageal temperature (LET) monitoring, oesophageal injury is still possible. A dedicated device for proactive oesophageal cooling has recently been cleared by the Food and Drug Administration to reduce the likelihood of ablation-related oesophageal injury resulting from radiofrequency cardiac ablation procedures. This report describes the first uses of proactive oesophageal cooling for oesophageal protection during the epicardial ablation portion of hybrid convergent procedures. Case summary: Five patients with long-standing persistent AF underwent hybrid convergent ablations with the use of proactive oesophageal cooling as means of oesophageal protection. All cases were completed successfully with no adverse effects. Most notably, cases were shorter when compared to cases using LET monitoring, likely due to lack of pauses for overheating of the oesophagus that would otherwise be required to prevent damage to the oesophagus. Discussion: This report describes the first uses of proactive oesophageal cooling for oesophageal protection during the epicardial ablation portion of five hybrid convergent procedures. Use of cooling enabled uninhibited deployment of lesions without the need to pause energy delivery due to elevated temperatures in the oesophagus, providing a feasible alternative to LET monitoring.

3.
J Vis Exp ; (206)2024 Apr 19.
Artigo em Inglês | MEDLINE | ID: mdl-38709062

RESUMO

Radiofrequency (RF) ablation to perform pulmonary vein isolation (PVI) for the treatment of atrial fibrillation involves some risk to collateral structures, including the esophagus. Proactive esophageal cooling using a dedicated device has been granted marketing authorization by the Food and Drug Administration (FDA) to reduce the risk of ablation-related esophageal injury due to RF cardiac ablation procedures, and more recent data also suggest that esophageal cooling may contribute to improved long-term efficacy of treatment. A mechanistic underpinning explaining these findings exists through the quantification of lesion placement contiguity defined as the Continuity Index (CI). Kautzner et al. quantified the CI by the order of lesion placement, such that whenever a lesion is placed non-adjacent to the prior lesion, the CI is incremented by the number of segments the catheter tip has moved over. To facilitate real-time calculation of the CI and encourage further adoption of this instrument, we propose a modification in which the placement of non-adjacent lesions increments the CI by only one unit, avoiding the need to count potentially nebulous markers of atrial segmentation. The objective of this protocol is to describe the methods of calculating the CI both prospectively during real-time PVI cases and retrospectively using recorded case data. A comparison of the results obtained between cases that utilized proactive esophageal cooling and cases that used luminal esophageal temperature (LET) monitoring is then provided.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Esôfago , Fibrilação Atrial/cirurgia , Esôfago/cirurgia , Humanos , Ablação por Cateter/métodos , Ablação por Cateter/instrumentação , Veias Pulmonares/cirurgia
4.
J Cardiovasc Electrophysiol ; 35(6): 1150-1155, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38566579

RESUMO

INTRODUCTION: Proactive esophageal cooling has been FDA cleared to reduce the likelihood of ablation-related esophageal injury resulting from radiofrequency (RF) cardiac ablation procedures. Data suggest that procedure times for RF pulmonary vein isolation (PVI) also decrease when proactive esophageal cooling is employed instead of luminal esophageal temperature (LET) monitoring. Reduced procedure times may allow increased electrophysiology (EP) lab throughput. We aimed to quantify the change in EP lab throughput of PVI cases after the introduction of proactive esophageal cooling. METHODS: EP lab throughput data were obtained from three EP groups. We then compared EP lab throughput over equal time frames at each site before (pre-adoption) and after (post-adoption) the adoption of proactive esophageal cooling. RESULTS: Over the time frame of the study, a total of 2498 PVIs were performed over a combined 74 months, with cooling adopted in September 2021, November 2021, and March 2022 at each respective site. In the pre-adoption time frame, 1026 PVIs were performed using a combination of LET monitoring with the addition of esophageal deviation when deemed necessary by the operator. In the post-adoption time frame, 1472 PVIs were performed using exclusively proactive esophageal cooling, representing a mean 43% increase in throughput (p < .0001), despite the loss of two operators during the post-adoption time frame. CONCLUSION: Adoption of proactive esophageal cooling during PVI ablation procedures is associated with a significant increase in EP lab throughput, even after a reduction in total number of operating physicians in the post-adoption group.


Assuntos
Ablação por Cateter , Esôfago , Veias Pulmonares , Humanos , Esôfago/cirurgia , Ablação por Cateter/efeitos adversos , Fatores de Tempo , Veias Pulmonares/cirurgia , Veias Pulmonares/fisiopatologia , Resultado do Tratamento , Hipotermia Induzida , Fatores de Risco , Duração da Cirurgia , Técnicas Eletrofisiológicas Cardíacas , Fluxo de Trabalho , Estudos Retrospectivos , Fibrilação Atrial/cirurgia , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/diagnóstico , Masculino
6.
medRxiv ; 2024 Apr 12.
Artigo em Inglês | MEDLINE | ID: mdl-38645228

RESUMO

Background: Proactive esophageal cooling is FDA cleared to reduce the likelihood of esophageal injury during radiofrequency ablation for treatment of atrial fibrillation (AF). Long-term follow-up data have also shown improved freedom from arrhythmia with proactive esophageal cooling compared to luminal esophageal temperature (LET) monitoring during pulmonary vein isolation (PVI). One hypothesized mechanism is improved lesion contiguity (as measured by the Continuity Index) with the use of cooling. We aimed to compare the Continuity Index of PVI cases using proactive esophageal cooling to those using LET monitoring. Methods: Continuity Index was calculated for PVI cases at two different hospitals within the same health system using a slightly modified Continuity Index to facilitate both real-time calculation during observation of PVI cases and retrospective determination from recorded cases. The results were then compared between proactively cooled cases and those using LET monitoring. Results: Continuity Indices for a total of 101 cases were obtained; 77 cases using proactive esophageal cooling and 24 cases using traditional LET monitoring. With proactive esophageal cooling, the average Continuity Index was 2.7 (1.3 on the left pulmonary vein, and 1.5 on the right pulmonary vein). With LET monitoring, the average Continuity Index was 27.3 (14.3 on the left, and 12.9 on the right), for a difference of 24.6 (p < 0.001). Conclusion: Proactive esophageal cooling during PVI is associated with significantly improved lesion contiguity when compared to LET monitoring. This finding may offer a mechanism for the greater freedom from arrhythmia seen with proactive cooling in long-term follow-up.

7.
Lasers Surg Med ; 56(4): 392-403, 2024 04.
Artigo em Inglês | MEDLINE | ID: mdl-38436122

RESUMO

BACKGROUND AND OBJECTIVES: Laser ablation is increasingly used to treat atrial fibrillation (AF). However, atrioesophageal injury remains a potentially serious complication. While proactive esophageal cooling (PEC) reduces esophageal injury during radiofrequency ablation, the effects of PEC during laser ablation have not previously been determined. We aimed to evaluate the protective effects of PEC during laser ablation of AF by means of a theoretical study based on computer modeling. METHODS: Three-dimensional mathematical models were built for 20 different cases including a fragment of atrial wall (myocardium), epicardial fat (adipose tissue), connective tissue, and esophageal wall. The esophagus was considered with and without PEC. Laser-tissue interaction was modeled using Beer-Lambert's law, Pennes' Bioheat equation was used to compute the resultant heating, and the Arrhenius equation was used to estimate the fraction of tissue damage (FOD), assuming a threshold of 63% to assess induced necrosis. We modeled laser irradiation power of 8.5 W over 20 s. Thermal simulations extended up to 250 s to account for thermal latency. RESULTS: PEC significantly altered the temperature distribution around the cooling device, resulting in lower temperatures (around 22°C less in the esophagus and 9°C in the atrial wall) compared to the case without PEC. This thermal reduction translated into the absence of transmural lesions in the esophagus. The esophagus was thermally damaged only in the cases without PEC and with a distance equal to or shorter than 3.5 mm between the esophagus and endocardium (inner boundary of the atrial wall). Furthermore, PEC demonstrated minimal impact on the lesion created across the atrial wall, either in terms of maximum temperature or FOD. CONCLUSIONS: PEC reduces the potential for esophageal injury without degrading the intended cardiac lesions for a variety of different tissue thicknesses. Thermal latency may influence lesion formation during laser ablation and may play a part in any collateral damage.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Terapia a Laser , Humanos , Esôfago/cirurgia , Esôfago/lesões , Esôfago/patologia , Átrios do Coração/cirurgia , Fibrilação Atrial/cirurgia , Lasers , Computadores , Ablação por Cateter/métodos
8.
JACC Clin Electrophysiol ; 9(12): 2558-2570, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37737773

RESUMO

BACKGROUND: Active esophageal cooling reduces the incidence of endoscopically identified severe esophageal lesions during radiofrequency (RF) catheter ablation of the left atrium for the treatment of atrial fibrillation. A formal analysis of the atrioesophageal fistula (AEF) rate with active esophageal cooling has not previously been performed. OBJECTIVES: The authors aimed to compare AEF rates before and after the adoption of active esophageal cooling. METHODS: This institutional review board (IRB)-approved study was a prospective analysis of retrospective data, designed before collecting and analyzing the real-world data. The number of AEFs occurring in equivalent time frames before and after adoption of cooling using a dedicated esophageal cooling device (ensoETM, Attune Medical) were quantified across 25 prespecified hospital systems. AEF rates were then compared using generalized estimating equations robust to cluster correlation. RESULTS: A total of 14,224 patients received active esophageal cooling during RF ablation across the 25 hospital systems, which included a total of 30 separate hospitals. In the time frames before adoption of active cooling, a total of 10,962 patients received primarily luminal esophageal temperature (LET) monitoring during their RF ablations. In the preadoption cohort, a total of 16 AEFs occurred, for an AEF rate of 0.146%, in line with other published estimates for procedures using LET monitoring. In the postadoption cohort, no AEFs were found in the prespecified sites, yielding an AEF rate of 0% (P < 0.0001). CONCLUSIONS: Adoption of active esophageal cooling during RF ablation of the left atrium for the treatment of atrial fibrillation was associated with a significant reduction in AEF rate.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Fístula Esofágica , Humanos , Fibrilação Atrial/cirurgia , Fibrilação Atrial/complicações , Estudos Retrospectivos , Fístula Esofágica/epidemiologia , Fístula Esofágica/etiologia , Ablação por Cateter/métodos
9.
Ther Hypothermia Temp Manag ; 13(4): 225-229, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37527424

RESUMO

Fever is a recognized protective factor in patients with sepsis, and growing data suggest beneficial effects on outcomes in sepsis with elevated temperature, with a recent pilot randomized controlled trial (RCT) showing lower mortality by warming afebrile sepsis patients in the intensive care unit (ICU). The objective of this prospective single-site RCT was to determine if core warming improves respiratory physiology of mechanically ventilated patients with coronavirus disease 2019 (COVID-19), allowing earlier weaning from ventilation, and greater overall survival. A total of 19 patients with mean age of 60.5 (±12.5) years, 37% female, mean weight 95.1 (±18.6) kg, and mean body mass index 34.5 (±5.9) kg/m2 with COVID-19 requiring mechanical ventilation were enrolled from September 2020 to February 2022. Patients were randomized 1:1 to standard of care or to receive core warming for 72 hours through an esophageal heat exchanger commonly utilized in critical care and surgical patients. The maximum target temperature was 39.8°C. A total of 10 patients received usual care and 9 patients received esophageal core warming. After 72 hours of warming, the ratio of arterial oxygen partial pressure to fractional inspired oxygen (PaO2/FiO2) ratios were 197 (±32) and 134 (±13.4), cycle thresholds were 30.8 (±6.4) and 31.4 (±3.2), ICU mortalities were 40% and 44%, 30-day mortalities were 30% and 22%, and mean 30-day ventilator-free days were 11.9 (±12.6) and 6.8 (±10.2) for standard of care and warmed patients, respectively (p = NS). This pilot study suggests that core warming of patients with COVID-19 undergoing mechanical ventilation is feasible and appears safe. Optimizing time to achieve febrile-range temperature may require a multimodal temperature management strategy to further evaluate effects on outcome. ClinicalTrials.gov Identifier: NCT04494867.


Assuntos
COVID-19 , Hipotermia Induzida , Sepse , Feminino , Humanos , Pessoa de Meia-Idade , Masculino , COVID-19/terapia , Respiração Artificial , Projetos Piloto , Oxigênio
10.
Resuscitation ; 191: 109903, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37423492

RESUMO

INTRODUCTION: Cognitive activity and awareness during cardiac arrest (CA) are reported but ill understood. This first of a kind study examined consciousness and its underlying electrocortical biomarkers during cardiopulmonary resuscitation (CPR). METHODS: In a prospective 25-site in-hospital study, we incorporated a) independent audiovisual testing of awareness, including explicit and implicit learning using a computer and headphones, with b) continuous real-time electroencephalography(EEG) and cerebral oxygenation(rSO2) monitoring into CPR during in-hospital CA (IHCA). Survivors underwent interviews to examine for recall of awareness and cognitive experiences. A complementary cross-sectional community CA study provided added insights regarding survivors' experiences. RESULTS: Of 567 IHCA, 53(9.3%) survived, 28 of these (52.8%) completed interviews, and 11(39.3%) reported CA memories/perceptions suggestive of consciousness. Four categories of experiences emerged: 1) emergence from coma during CPR (CPR-induced consciousness [CPRIC]) 2/28(7.1%), or 2) in the post-resuscitation period 2/28(7.1%), 3) dream-like experiences 3/28(10.7%), 4) transcendent recalled experience of death (RED) 6/28(21.4%). In the cross-sectional arm, 126 community CA survivors' experiences reinforced these categories and identified another: delusions (misattribution of medical events). Low survival limited the ability to examine for implicit learning. Nobody identified the visual image, 1/28(3.5%) identified the auditory stimulus. Despite marked cerebral ischemia (Mean rSO2 = 43%) normal EEG activity (delta, theta and alpha) consistent with consciousness emerged as long as 35-60 minutes into CPR. CONCLUSIONS: Consciousness. awareness and cognitive processes may occur during CA. The emergence of normal EEG may reflect a resumption of a network-level of cognitive activity, and a biomarker of consciousness, lucidity and RED (authentic "near-death" experiences).


Assuntos
Reanimação Cardiopulmonar , Parada Cardíaca , Parada Cardíaca Extra-Hospitalar , Humanos , Estado de Consciência , Reanimação Cardiopulmonar/métodos , Estudos Prospectivos , Estudos Transversais , Morte , Biomarcadores
11.
J Interv Card Electrophysiol ; 66(7): 1621-1629, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-36670327

RESUMO

BACKGROUND: Active esophageal cooling during pulmonary vein isolation (PVI) with radiofrequency (RF) ablation for the treatment of atrial fibrillation (AF) is increasingly being utilized to reduce esophageal injury and atrioesophageal fistula formation. Randomized controlled data also show trends towards increased freedom from AF when using active cooling. This study aimed to compare 1-year arrhythmia recurrence rates between patients treated with luminal esophageal temperature (LET) monitoring versus active esophageal cooling during left atrial ablation. METHOD: Data from two healthcare systems (including 3 hospitals and 4 electrophysiologists) were reviewed for patient rhythm status at 1-year follow-up after receiving PVI for the treatment of AF. Results were compared between patients receiving active esophageal cooling (ensoETM, Attune Medical, Chicago, IL) and those treated with traditional LET monitoring using Kaplan-Meier estimates. RESULTS: A total of 513 patients were reviewed; 253 received LET monitoring using either single or multi-sensor temperature probes; and 260 received active cooling. The mean age was 66.8 (SD ± 10) years, and 36.8% were female. Arrhythmias were 60.1% paroxysmal AF, 34.3% persistent AF, and 5.6% long-standing persistent AF, with no significant difference between groups. At 1-year follow-up, KM estimates for freedom from AF were 58.2% for LET-monitored patients and 72.2% for actively cooled patients, for an absolute increase in freedom from AF of 14% with active esophageal cooling (p = .03). Adjustment for the confounders of patient age, gender, type of AF, and operator with an inverse probability of treatment weighted Cox proportional hazards model yielded a hazard ratio of 0.6 for the effect of cooling on AF recurrence (p = 0.045). CONCLUSIONS: In this first study to date of the association between esophageal protection strategy and long-term efficacy of left atrial RF ablation, a clinically and statistically significant improvement in freedom from atrial arrhythmia at 1 year was found in patients treated with active esophageal cooling when compared to patients who received LET monitoring. More rigorous prospective studies or randomized studies are required to validate the findings of the current study.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Idoso , Feminino , Humanos , Masculino , Ablação por Cateter/métodos , Átrios do Coração/cirurgia , Estudos Prospectivos , Veias Pulmonares/cirurgia , Recidiva , Resultado do Tratamento , Pessoa de Meia-Idade
12.
J Med Econ ; 26(1): 158-167, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36537305

RESUMO

BACKGROUND: Left atrial ablation to obtain pulmonary vein isolation (PVI) for the treatment of atrial fibrillation (AF) is a technologically intensive procedure utilizing innovative and continually improving technology. Changes in the technology utilized for PVI can in turn lead to changes in procedure costs. Because of the proximity of the esophagus to the posterior wall of the left atrium, various technologies have been utilized to protect against thermal injury during ablation. The impact on hospital costs during PVI ablation from utilization of different technologies for esophageal protection during ablation has not previously been evaluated. OBJECTIVE: To compare the costs of active esophageal cooling to luminal esophageal temperature (LET) monitoring during left atrial ablation. METHODS: We performed a time-driven activity-based costing (TDABC) analysis to determine costs for PVI procedures. Published data and literature review were utilized to determine differences in procedure time and same-day discharge rates using different esophageal protection technologies and to determine the cost impacts of same-day discharge versus overnight hospitalization after PVI procedures. The total costs were then compared between cases using active esophageal cooling to those using LET monitoring. RESULTS: The effect of implementing active esophageal cooling was associated with up to a 24.7% reduction in mean total procedure time, and an 18% increase in same-day discharge rate. TDABC analysis identified a $681 reduction in procedure costs associated with the use of active esophageal cooling after including the cost of the esophageal cooling device. Factoring in the 18% increase in same-day discharge resulted in an increased cost savings of $2,135 per procedure. CONCLUSIONS: The use of active esophageal cooling is associated with significant cost-savings when compared to traditional LET monitoring, even after accounting for the additional cost of the cooling device. These savings originate from a per-patient procedural time savings and a per-population improvement in same-day discharge rate.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Humanos , Fibrilação Atrial/cirurgia , Alta do Paciente , Redução de Custos , Esôfago/cirurgia , Esôfago/lesões , Átrios do Coração/cirurgia , Ablação por Cateter/métodos , Resultado do Tratamento
13.
Expert Rev Med Devices ; 19(12): 949-957, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36413154

RESUMO

INTRODUCTION: Radiofrequency (RF) ablation of the left atrium of the heart is increasingly used to treat atrial fibrillation (AF). Unfortunately, inadvertent thermal injury to the esophagus can occur during this procedure, potentially creating an atrioesophageal fistula (AEF) which is 80% fatal. The ensoETM (Attune Medical, Chicago, IL), is an esophageal cooling device that has been shown to reduce thermal injury to the esophagus during RF ablation. AREAS COVERED: This review summarizes growing evidence related to active esophageal cooling during RF ablation for the treatment of AF. The review presents data demonstrating improved outcomes related to patient safety and procedural efficiency and suggests directions for future research. EXPERT OPINION: The use of active esophageal cooling during RF ablation reduces esophageal injury, reduces or eliminates fluoroscopy requirements, reduces procedure duration and post-operative pain, and increases long-term freedom from arrhythmia. These effects in turn increase patient same-day discharge rates, decrease operator cognitive load, and reduce cost. These findings are likely to further accelerate the adoption of active esophageal cooling.


Atrial fibrillation is a condition in which the heart beats irregularly, causing symptoms such as palpitations, dizziness, shortness of breath, and chest pain. Atrial fibrillation increases the risk of stroke, heart failure, dementia, and death. One treatment for atrial fibrillation is a procedure called a catheter ablation. This procedure is minimally invasive and is performed by a specialized cardiologist, called an electrophysiologist. The electrophysiologist, or operator, uses an energy source, such as radiofrequency energy (radio waves), to stop erratic electrical signals from traveling through the heart. One complication of the catheter ablation is an inadvertent injury to the esophagus, the organ that passes food from the mouth to the stomach. If the injury is severe, it may develop into an atrioesophageal fistula, which often results in death. In this review, a new technology is described that helps prevent this type of injury and can provide additional benefits for the patient, operator, and hospital.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Ablação por Radiofrequência , Humanos , Átrios do Coração/cirurgia , Esôfago/cirurgia , Fibrilação Atrial/cirurgia , Ablação por Radiofrequência/efeitos adversos
14.
J Vis Exp ; (186)2022 08 25.
Artigo em Inglês | MEDLINE | ID: mdl-36094261

RESUMO

Various methods are utilized during radiofrequency (RF) pulmonary vein isolation (PVI) for the treatment of atrial fibrillation (AF) to protect the esophagus from inadvertent thermal injury. Active esophageal cooling is increasingly being used over traditional luminal esophageal temperature (LET) monitoring, and each approach may influence procedure times and the variability around those times. The objective of this study is to measure the effects on procedure time and variability in procedure time of two different esophageal protection strategies utilizing advanced informatics techniques to facilitate data extraction. Trained clinical informaticists first performed a contextual inquiry in the catheterization laboratory to determine laboratory workflows and observe the documentation of procedural data within the electronic health record (EHR). These EHR data structures were then identified in the electronic health record reporting database, facilitating data extraction from the EHR. A manual chart review using a REDCap database created for the study was then performed to identify additional data elements, including the type of esophageal protection used. Procedure duration was then compared using summary statistics and standard measures of dispersion. A total of 164 patients underwent radiofrequency PVI over the study timeframe; 63 patients (38%) were treated with LET monitoring, and 101 patients (62%) were treated with active esophageal cooling. The mean procedure time was 176 min (SD of 52 min) in the LET monitoring group compared to 156 min (SD of 40 min) in the esophageal cooling group (P = 0.012). Thus, active esophageal cooling during PVI is associated with reduced procedure time and reduced variation in procedure time when compared to traditional LET monitoring.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Fibrilação Atrial/cirurgia , Temperatura Corporal , Ablação por Cateter/efeitos adversos , Esôfago/lesões , Humanos , Veias Pulmonares/cirurgia
15.
Int J Hyperthermia ; 39(1): 1202-1212, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36104029

RESUMO

BACKGROUND: Proactive cooling with a novel cooling device has been shown to reduce endoscopically identified thermal injury during radiofrequency (RF) ablation for the treatment of atrial fibrillation using medium power settings. We aimed to evaluate the effects of proactive cooling during high-power short-duration (HPSD) ablation. METHODS: A computer model accounting for the left atrium (1.5 mm thickness) and esophagus including the active cooling device was created. We used the Arrhenius equation to estimate the esophageal thermal damage during 50 W/ 10 s and 90 W/ 4 s RF ablations. RESULTS: With proactive esophageal cooling in place, temperatures in the esophageal tissue were significantly reduced from control conditions without cooling, and the resulting percentage of damage to the esophageal wall was reduced around 50%, restricting damage to the epi-esophageal region and consequently sparing the remainder of the esophageal tissue, including the mucosal surface. Lesions in the atrial wall remained transmural despite cooling, and maximum width barely changed (<0.8 mm). CONCLUSIONS: Proactive esophageal cooling significantly reduces temperatures and the resulting fraction of damage in the esophagus during HPSD ablation. These findings offer a mechanistic rationale explaining the high degree of safety encountered to date using proactive esophageal cooling, and further underscore the fact that temperature monitoring is inadequate to avoid thermal damage to the esophagus.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Fibrilação Atrial/cirurgia , Temperatura Corporal , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Esôfago/lesões , Esôfago/cirurgia , Átrios do Coração/cirurgia , Humanos
16.
J Innov Card Rhythm Manag ; 12(11): 4749-4755, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34676132

RESUMO

Risks to collateral structures exist with radiofrequency (RF) ablation of the left atrium to obtain pulmonary vein isolation (PVI) for the treatment of atrial fibrillation. Passive luminal esophageal temperature (LET) monitoring is commonly utilized, but increasing data suggest limited benefits with LET monitoring. In contrast, active cooling of the esophagus has been shown to significantly reduce esophageal injury. Active cooling of the esophagus also avoids the need for stopping and repositioning an LET probe during use, which may reduce the need for fluoroscopy use. This study aimed to measure the impact on fluoroscopy use during RF ablation with esophageal cooling using a dedicated cooling device in a low-fluoroscopy practice. All patients who underwent PVI over a one-year timeframe by a single provider were analyzed. Patients undergoing PVI prior to the incorporation of an esophageal cooling protocol into standard ablation practice were treated with traditional LET monitoring. Patients treated after this point received active esophageal cooling, in which no LET monitoring is utilized. A total of 280 patients were treated; 91 patients were treated using LET monitoring, and 189 patients were treated with esophageal cooling. The mean total fluoroscopy time before the implementation of the esophageal cooling protocol in 91 patients was 194 seconds [standard deviation (SD): 182 seconds] per case, with a median of 144 seconds. The mean total fluoroscopy time after implementation in 189 patients was 126 seconds (SD: 120 seconds) per case with a median of 96 seconds, representing a reduction of 35% per case (p < 0.0001, Mann-Whitney U test). In this largest study to date of active esophageal cooling during PVI, a 35% reduction in fluoroscopy time compared with patients who received LET monitoring was found. This reduction was seen despite an already low fluoroscopy usage rate in place.

19.
J Med Virol ; 93(9): 5358-5366, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-33913555

RESUMO

Currently available data are consistent with increased severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) replication at temperatures encountered in the upper airways (25-33°C when breathing room temperature air, 25°C) compared to those in the lower airways (37°C). One factor that may contribute to more rapid viral growth in the upper airways is the exponential increase in SARS-CoV-2 stability that occurs with reductions in temperature, as measured in vitro. Because SARS-CoV-2 frequently initiates infection in the upper airways before spreading through the body, increased upper airway viral growth early in the disease course may result in more rapid progression of disease and potentially contribute to more severe outcomes. Similarly, higher SARS-CoV-2 viral titer in the upper airways likely supports more efficient transmission. Conversely, the possible significance of air temperature to upper airway viral growth suggests that prolonged delivery of heated air might represent a preventative measure and prophylactic treatment for coronavirus disease 2019.


Assuntos
COVID-19/transmissão , Nasofaringe/virologia , SARS-CoV-2/fisiologia , Temperatura , Traqueia/virologia , Replicação Viral/fisiologia , Ar/análise , COVID-19/epidemiologia , COVID-19/patologia , COVID-19/virologia , Humanos , Umidade , Profilaxia Pós-Exposição/métodos , SARS-CoV-2/patogenicidade , Índice de Gravidade de Doença , Termodinâmica
20.
PLoS One ; 15(12): e0243190, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33259540

RESUMO

BACKGROUND: Coronavirus disease 2019 (COVID-19), caused by the virus SARS-CoV-2, is spreading rapidly across the globe, with little proven effective therapy. Fever is seen in most cases of COVID-19, at least at the initial stages of illness. Although fever is typically treated (with antipyretics or directly with ice or other mechanical means), increasing data suggest that fever is a protective adaptive response that facilitates recovery from infectious illness. OBJECTIVE: To describe a randomized controlled pilot study of core warming patients with COVID-19 undergoing mechanical ventilation. METHODS: This prospective single-site randomized controlled pilot study will enroll 20 patients undergoing mechanical ventilation for respiratory failure due to COVID-19. Patients will be randomized 1:1 to standard-of-care or to receive core warming via an esophageal heat exchanger commonly utilized in critical care and surgical patients. The primary outcome is patient viral load measured by lower respiratory tract sample. Secondary outcomes include severity of acute respiratory distress syndrome (as measured by PaO2/FiO2 ratio) 24, 48, and 72 hours after initiation of treatment, hospital and intensive care unit length of stay, duration of mechanical ventilation, and 30-day mortality. RESULTS: Resulting data will provide effect size estimates to guide a definitive multi-center randomized clinical trial. ClinicalTrials.gov registration number: NCT04426344. CONCLUSIONS: With growing data to support clinical benefits of elevated temperature in infectious illness, this study will provide data to guide further understanding of the role of active temperature management in COVID-19 treatment and provide effect size estimates to power larger studies.


Assuntos
Temperatura Corporal , COVID-19/fisiopatologia , COVID-19/terapia , Ventiladores Mecânicos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Projetos Piloto
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA