Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Environ Monit Assess ; 196(1): 98, 2023 Dec 28.
Artigo em Inglês | MEDLINE | ID: mdl-38153544

RESUMO

A new conceptual framework based on satellite data, including chlorophyll (CHL), sea surface temperature (SST) fronts, relative winds, current vectors, Ekman transport, and eddies, has been developed to identify potential fishing zones (PFZ) in the Bay of Bengal (BoB). The framework aims to provide persistent forecasts, even under cloudy conditions, based on feature propagation. The validation of the PFZ was carried out using fish catch data collected by the Fishery Survey of India (FSI) between 2016 and 2018. Hooking rates (HR) from longlines and catch per unit effort (CPUE) from trawl nets were used to analyse the data points in hook rate categories (1.0-3.0 and > 3.0) and CPUE categories (50-100 kg and > 100 kg) and interpret them with the PFZ maps. The analysis showed that the high fish catch locations were consistent with persisting features in the BoB, such as high chlorophyll patches, SST fronts, and cyclonic eddies. The high fish catch locations based on hook rate and high CPUE were found to be collocated with the high chlorophyll persisting features and thermal gradients in the BoB. The regression analysis shows that availability of the food (CHL) had the strongest correlation with fish catch, followed by the comfort condition (fronts and eddies).


Assuntos
Baías , Pesqueiros , Animais , Clorofila , Monitoramento Ambiental
2.
J Med Phys ; 47(1): 86-92, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35548027

RESUMO

Aim: The aim of this article is to assess Tamil Nadu adult diagnostic reference levels (DRLs) by collecting radiation dose data from the four different dental modalities. Materials and Methods: The study was carried out using routine adult exposure settings in 131 intraoral, 75 panoramic, 35 cephalometric, and 10 dental cone beam computed tomography (CBCT) X-ray devices. DRLs were assessed for intraoral and extraoral (panoramic, cephalometric, and CBCT) examinations in terms of incident air kerma (Ka, i) and kerma area product (PKA), respectively. Air kerma measurements, for all dental units, were made using calibrated RTI black Piranha 557 dosimeter (RTI Electronics AB, Sweden). The dosimeter was kept at the exit cone of the X-ray tube and on the detector side of the X-ray unit for intraoral and extraoral air kerma measurements, respectively. The obtained air kerma in extraoral modalities is multiplied with the beam area to evaluate PKA. Results: The third quartile values calculated from the median for adult intraoral (mandibular molar), panoramic, cephalometric, and CBCT were 1.5 mGy, 116 mGycm2, 40 mGycm2, and 532 mGycm2, respectively. The proposed DRL in the present study was comparable to those reported in Germany, Greece, the UK, Japan, and Korea. Conclusion: This study revealed the need for dose management and radiation dose optimization, in various dental facilities in the state. It was also found that dental facilities employed with the digital type of detector are not always related to lower exposure.

3.
J Med Phys ; 45(3): 182-186, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33487931

RESUMO

AIM: The current work aims to calculate dose area product (DAP) and to determine regional diagnostic reference level (DRL) for pediatric panoramic radiography in Tamil Nadu. MATERIALS AND METHODS: In this study, DAP was calculated after finding the product of air kerma on the detector side of scanner with the corresponding exposed area. The obtained DAP values were further analyzed, and DRL was calculated using Microsoft Excel. The study was carried out with routine pediatric exposure parameters. RESULTS: The obtained mean, range, and third quartile values for pediatric panoramic radiography are found to be 65 mGycm2, 11-148 mGycm2, and 82 mGycm2, respectively. The proposed DRL is comparable with the other countries' DRL. CONCLUSION: Based on the results of the present study, it was observed that there exists a wide difference in mean doses among the panoramic scanners. The variation in radiation doses between the clinics/hospitals and similar scanners suggests a large potential for optimization of panoramic procedures.

4.
J Med Phys ; 44(4): 292-297, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31908390

RESUMO

AIM: The aim of this study was to calculate dose area product (DAP) and to determine diagnostic reference level (DRL) for adult panoramic procedures in Tamil Nadu. MATERIALS AND METHODS: In this study, air kerma on the front side of the secondary collimator was measured with a Black Piranha, RTI Electronics, Sweden and multiplied with the corresponding exposed area to calculate DAP. The obtained DAP values were further analyzed, and DRL was calculated using the Microsoft Excel software. The study was carried out with regular adult exposure parameters. RESULTS: The mean, range, and 3rd quartile values for 67 panoramic scanners in Tamil Nadu, India, were calculated as 94 mGycm2, 41 mGycm2-165 mGycm2, and 114.3 mGycm2, respectively. The results are comparable with other international studies. CONCLUSION: The present study suggests that further optimization can be achieved in many centers by the recruitment of professionally qualified radiographers and conducting periodic training programs on the optimization of exposure parameters. Considering this as the first study for the dental DRL assessment, further studies are suggested to establish national dental DRL in India.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA