Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Am J Ophthalmol ; 262: 186-191, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38191066

RESUMO

PURPOSE: To investigate the results of patients undergoing surgical treatment for strabismic diplopia in thyroid eye disease (TED) following teprotumumab. DESIGN: Multicenter, retrospective, case series. METHODS: We report 28 patients who underwent extraocular muscle surgery for strabismic diplopia after treatment with teprotumumab at 7 different academic centers. Elapsed time from last teprotumumab dose to the date of surgery, previous orbital decompression, primary preoperative horizontal and vertical deviation, surgical procedure, and 2-month postoperative results were collected from the patient records. RESULTS: Sixteen (57%) patients were diplopia-free after 1 surgery. Three (11%) chose prism spectacles to correct residual diplopia, 2 (7%) used compensatory head posture to resolve diplopia, and 1 (4%) had intermittent diplopia and was functionally improved (choosing no prisms or further surgery). These were considered treatment successes. Three (11%) patients required reoperation, and all were diplopia-free after their second procedure. CONCLUSIONS: Most patients requiring surgery for strabismic diplopia following teprotumumab achieve good outcomes with success rates comparable to series published before the availability of teprotumumab.


Assuntos
Anticorpos Monoclonais Humanizados , Diplopia , Oftalmopatia de Graves , Músculos Oculomotores , Estrabismo , Humanos , Estudos Retrospectivos , Masculino , Feminino , Músculos Oculomotores/cirurgia , Músculos Oculomotores/fisiopatologia , Pessoa de Meia-Idade , Oftalmopatia de Graves/cirurgia , Oftalmopatia de Graves/tratamento farmacológico , Diplopia/fisiopatologia , Estrabismo/cirurgia , Estrabismo/fisiopatologia , Anticorpos Monoclonais Humanizados/uso terapêutico , Idoso , Adulto , Resultado do Tratamento , Procedimentos Cirúrgicos Oftalmológicos , Descompressão Cirúrgica , Visão Binocular/fisiologia
2.
Am J Ophthalmol ; 149(6): 882-886.e1, 2010 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-20231013

RESUMO

PURPOSE: To determine capsular breakage risk from contact by phacoemulsification needles by machine and tip type. DESIGN: Experimental laboratory investigation. METHODS: Infiniti (Alcon, Inc.) with Intrepid cartridges and Signature (Abbott Medical Optics, Inc.) phacoemulsification machines were tested using 19- and 20-gauge sharp and rounded tips. Actual and unoccluded flow vacuum were determined at 550 mm Hg, bottle height of 75 cm, and machine-indicated flow rate of 60 mL/minute. Breakage from brief tip contact with a capsular surrogate and human cadaveric lenses was calculated. RESULTS: Nineteen-gauge tips had more flow and less unoccluded flow vacuum than 20-gauge tips for both machines, with highest unoccluded flow vacuum in the Infiniti. The 19-gauge sharp tip was more likely than the 20-gauge sharp tip to cause surrogate breakage for Signature with micropulse and Ellips (Abbott Medical Optics, Inc.) ultrasound at 100% power. For Infiniti using OZil (Alcon, Inc.) ultrasound, 20-gauge sharp tips were more likely than 19-gauge sharp tips to break the membrane. For cadaveric lenses, using rounded 20-gauge tips at 100% power, breakage rates were micropulse (2.3%), Ellips (2.3%), OZil (5.3%). Breakage rates for sharp 20-gauge Ellips tips were higher than for rounded tips. CONCLUSIONS: Factors influencing capsular breakage may include active vacuum at the tip, flow rate, needle gauge, and sharpness. Nineteen-gauge sharp tips were more likely than 20-gauge tips to cause breakage in lower vacuum methods. For higher-vacuum methods, breakage is more likely with 20-gauge than with 19-gauge tips. Rounded-edge tips are less likely than sharp-edged tips to cause breakage.


Assuntos
Traumatismos Oculares/etiologia , Cápsula do Cristalino/lesões , Agulhas/efeitos adversos , Facoemulsificação/instrumentação , Humanos , Microcirurgia/instrumentação , Modelos Biológicos , Medição de Risco , Ruptura , Vácuo
3.
Am J Ophthalmol ; 145(6): 1014-1017, 2008 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-18343350

RESUMO

PURPOSE: To compare three phacoemulsification machines for measurement accuracy and postocclusion surge (POS) in human cadaver eyes. DESIGN: In vitro comparisons of machine accuracy and POS. METHODS: Tip vacuum and flow were compared with machine indicated vacuum and flow. All machines were placed in two human cadaver eyes and POS was determined. RESULTS: Vacuum (% of actual) was 101.9% +/- 1.7% for Infiniti (Alcon, Fort Worth, Texas, USA), 93.2% +/- 3.9% for Stellaris (Bausch & Lomb, Rochester, New York, USA), and 107.8% +/- 4.6% for Signature (Advanced Medical Optics, Santa, Ana, California, USA; P < .0001). At 60 ml/minute flow, actual flow and unoccluded flow vacuum (UFV) was 55.8 +/- 0.4 ml/minute and 197.7 +/- 0.7 mm Hg for Infiniti, 53.5 +/- 0.0 ml/minute and 179.8 +/- 0.9 mm Hg for Stellaris, and 58.5 +/- 0.0 ml/minute and 115.1 +/- 2.3 mm Hg for Signature (P < .0001). POS in an 32-year-old eye was 0.33 +/- 0.05 mm for Infiniti, 0.16 +/- 0.06 mm for Stellaris, and 0.13 +/- 0.04 mm for Signature at 550 mm Hg, 60 cm bottle height, 45 ml/minute flow with 19-gauge tips (P < .0001 for Infiniti vs Stellaris and Signature). POS in an 81-year-old eye was 1.51 +/- 0.22 mm for Infiniti, 0.83 +/- 0.06 mm for Stellaris, 0.67 +/- 0.01 mm for Signature at 400 mm Hg vacuum, 70 cm bottle height, 40 ml/minute flow with 19-gauge tips (P < .0001). CONCLUSIONS: Machine-indicated accuracy, POS, and UFV were statistically significantly different. Signature had the lowest POS and vacuum to maintain flow. Regarding POS, Stellaris was close to Signature; regarding vacuum to maintain flow, Infiniti and Stellaris were similar. Minimizing POS and vacuum to maintain flow potentially are important in avoiding ocular damage and surgical complications.


Assuntos
Facoemulsificação/instrumentação , Pressão , Sucção/normas , Vácuo , Adulto , Idoso de 80 Anos ou mais , Drenagem , Humanos , Reprodutibilidade dos Testes
4.
Genes Dev ; 16(7): 796-805, 2002 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-11937488

RESUMO

Gene-specific and chromosome-wide mechanisms of transcriptional regulation control development in multicellular organisms. SDC-2, the determinant of hermaphrodite fate in Caenorhabditis elegans, is a paradigm for both modes of regulation. SDC-2 represses transcription of X chromosomes to achieve dosage compensation, and it also represses the male sex-determination gene her-1 to elicit hermaphrodite differentiation. We show here that SDC-2 recruits the entire dosage compensation complex to her-1, directing this X-chromosome repression machinery to silence an individual, autosomal gene. Functional dissection of her-1 in vivo revealed DNA recognition elements required for SDC-2 binding, recruitment of the dosage compensation complex, and transcriptional repression. Elements within her-1 differed in location, sequence, and strength of repression, implying that the dosage compensation complex may regulate transcription along the X chromosome using diverse recognition elements that play distinct roles in repression.


Assuntos
Proteínas de Caenorhabditis elegans/biossíntese , Proteínas de Caenorhabditis elegans/fisiologia , Cromossomos/ultraestrutura , Proteínas Repressoras/biossíntese , Proteínas Repressoras/fisiologia , Transcrição Gênica , Animais , Animais Geneticamente Modificados , Caenorhabditis elegans/genética , Proteínas de Caenorhabditis elegans/química , Proteínas de Caenorhabditis elegans/genética , Cromatina/metabolismo , Cromossomos/genética , DNA/metabolismo , Mecanismo Genético de Compensação de Dose , Feminino , Proteínas de Helminto/metabolismo , Masculino , Microscopia de Fluorescência , Modelos Genéticos , Fenótipo , Testes de Precipitina , Ligação Proteica , Proteínas Repressoras/química , Processos de Determinação Sexual , Cromossomo X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA