RESUMO
INTRODUCTION: High-power short-duration (HPSD) ablation at 50 W, guided by ablation index (AI) or lesion size index (LSI), and a 90 W/4 s very HSPD (vHPSD) setting are available for atrial fibrillation (AF) treatment. Yet, tissue temperatures during ablation with different catheters around venoatrial junction and collateral tissues remain unclear. METHODS: In this porcine study, we surgically implanted thermocouples on the epicardium near the superior vena cava (SVC), right pulmonary vein, and esophagus close to the inferior vena cava. We then compared tissue temperatures during 50W-HPSD guided by AI 400 or LSI 5.0, and 90 W/4 s-vHPSD ablation using THERMOCOOL SMARTTOUCH SF (STSF), TactiCath ablation catheter, sensor enabled (TacthCath), and QDOT MICRO (Qmode and Qmode+ settings) catheters. RESULTS: STSF produced the highest maximum tissue temperature (Tmax ), followed by TactiCath, and QDOT MICRO in Qmode and Qmode+ (62.7 ± 12.5°C, 58.0 ± 10.1°C, 50.0 ± 12.1°C, and 49.2 ± 8.4°C, respectively; p = .005), achieving effective transmural lesions. Time to lethal tissue temperature ≥50°C (t-T ≥ 50°C) was fastest in Qmode+, followed by TacthCath, STSF, and Qmode (4.3 ± 2.5, 6.4 ± 1.9, 7.1 ± 2.8, and 7.7 ± 3.1 s, respectively; p < .001). The catheter tip-to-thermocouple distance for lethal temperature (indicating lesion depth) from receiver operating characteristic curve analysis was deepest in STSF at 5.2 mm, followed by Qmode at 4.3 mm, Qmode+ at 3.1 mm, and TactiCath at 2.8 mm. Ablation at the SVC near the phrenic nerve led to sudden injury at t-T ≥ 50°C in all four settings. The esophageal adventitia injury was least deep with Qmode+ ablation (0.4 ± 0.1 vs. 0.8 ± 0.4 mm for Qmode, 0.9 ± 0.3 mm for TactiCath, and 1.1 ± 0.5 mm for STSF, respectively; p = .005), correlating with Tmax . CONCLUSION: This study revealed distinct tissue temperature patterns during HSPD and vHPSD ablations with the three catheters, affecting lesion effectiveness and collateral damage based on Tmax and/or t-T ≥ 50°C. These findings provide key insights into the safety and efficacy of AF ablation with these four settings.
Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Suínos , Animais , Temperatura , Veia Cava Superior/cirurgia , Catéteres , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Temperatura Alta , Ablação por Cateter/efeitos adversos , Veias Pulmonares/cirurgia , Resultado do TratamentoRESUMO
INTRODUCTION: Neither the actual in vivo tissue temperatures reached with 90 W/4 s-very high-power short-duration (vHPSD) ablation for atrial fibrillation nor the safety and efficacy profile have been fully elucidated. METHODS: We conducted a porcine study (n = 15) in which, after right thoracotomy, we implanted 6-8 thermocouples epicardially in the superior vena cava, right pulmonary vein, and esophagus close to the inferior vena cava. We compared tissue temperatures close to a QDOT MICRO catheter, between during 90 W/4 s-vHPSD ablation during ablation index (AI: target 400)-guided 50 W-HPSD ablation, both targeting a contact force of 8-15 g. RESULTS: Maximum tissue temperature reached during 90 W/4 s-vHPSD ablation did not differ significantly from that during 50 W-HPSD ablation (49.2 ± 8.4°C vs. 50.0 ± 12.1°C; p = .69) and correlated inversely with distance between the catheter tip and the thermocouple, regardless of the power settings (r = -0.52 and r = -0.37). Lethal temperature (≥50°C) was best predicted at a catheter tip-to-thermocouple distance cut-point of 3.13 and 4.27 mm, respectively. All lesions produced by 90 W/4 s-vHPSD or 50 W-HPSD ablation were transmural. Although there was no difference in the esophageal injury rate (50% vs. 66%, p = .80), the thermal lesion was significantly shallower with 90 W/4 s-vHPSD ablation than with 50W-HPSD ablation (381.3 ± 127.3 vs. 820.0 ± 426.1 µm from the esophageal adventitia; p = .039). CONCLUSION: Actual tissue temperatures reached with 90 W/4 s-vHPSD ablation appear similar to those with AI-guided 50 W-HPSD ablation, with the distance between the catheter tip and target tissue being shorter for the former. Although both ablation settings may create transmural lesions in thin atrial tissues, any resulting esophageal thermal lesions appear shallower with 90 W/4 s-vHPSD ablation.
Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Animais , Suínos , Temperatura , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Veia Cava Superior , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Esôfago/cirurgia , Esôfago/lesões , Veias Pulmonares/cirurgia , Resultado do TratamentoRESUMO
BACKGROUND: Neither the actual in vivo tissue temperatures reached with lesion size index (LSI)-guided high-power short-duration (HPSD) ablation for atrial fibrillation nor the safety profile has been elucidated. METHODS: We conducted a porcine study (n = 7) in which, after right thoracotomy, we implanted 6-8 thermocouples epicardially in the superior vena cava, right pulmonary vein, and esophagus close to the inferior vena cava. We compared tissue temperatures reached during 50 W-HPSD ablation with those reached during standard (30 W) ablation, both targeting an LSI of 5.0 (5-15 g contact force). RESULTS: Tmax (maximum tissue temperature when the thermocouple was located ≤5 mm from the catheter tip) reached during HPSD ablation was modestly higher than that reached during standard ablation (58.0 ± 10.1°C vs. 53.6 ± 9.2°C; p = .14) and peak tissue temperature correlated inversely with the distance between the catheter tip and the thermocouple, regardless of the power settings (HPSD: r = -0.63; standard: r = -0.66). Lethal temperature (≥50°C) reached 6.3 ± 1.8 s and 16.9 ± 16.1 s after the start of HPSD and standard ablation, respectively (p = .002), and it was best predicted at a catheter tip-to-thermocouple distance cut point of 2.8 and 5.3 mm, respectively. All lesions produced by HPSD ablation and by standard ablation were transmural. There was no difference between HPSD ablation and standard ablation in the esophageal injury rate (70% vs. 75%, p = .81), but the maximum distance from the esophageal adventitia to the injury site tended to be shorter (0.94 ± 0.29 mm vs. 1.40 ± 0.57 mm, respectively; p = .09). CONCLUSIONS: Actual tissue temperatures reached with LSI-guided HPSD ablation appear to be modestly higher, with a shorter distance between the catheter tip and thermocouple achieving lethal temperature, than those reached with standard ablation. HPSD ablation lasting <6 s may help minimize lethal thermal injury to the esophagus lying at a close distance.
Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Suínos , Animais , Temperatura , Veia Cava Superior , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Esôfago/cirurgia , Esôfago/lesões , Catéteres , Ablação por Cateter/efeitos adversos , Veias Pulmonares/cirurgia , Resultado do TratamentoRESUMO
BACKGROUND: Actual in vivo tissue temperatures and the safety profile during high-power short-duration (HPSD) ablation of atrial fibrillation have not been clarified. METHODS: We conducted an animal study in which, after a right thoracotomy, we implanted 6-8 thermocouples epicardially in the superior vena cava, right pulmonary vein, and esophagus close to the inferior vena cava. We recorded tissue temperatures during a 50 W-HPSD ablation and 30 W-standard ablation targeting an ablation index (AI) of 400 (5-15 g contact force). RESULTS: Maximum tissue temperatures reached with HSPD ablation were significantly higher than that reached with standard ablation (62.7 ± 12.5 vs. 52.7 ± 11.4°C, p = 0.033) and correlated inversely with the distance between the catheter tip and thermocouple, regardless of the power settings (HPSD: r = -0.71; standard: r = -0.64). Achievement of lethal temperatures (≥50°C) was within 7.6 ± 3.6 and 12.1 ± 4.1 s after HPSD and standard ablation, respectively (p = 0.003), and was best predicted at cutoff points of 5.2 and 4.4 mm, respectively. All HPSD ablation lesions were transmural, but 19.2% of the standard ablation lesions were not (p = 0.011). There was no difference between HPSD and standard ablation regarding the esophageal injury rate (30% vs. 33.3%, p > 0.99), with the injury appearing to be related to the short distance from the catheter tip. CONCLUSIONS: Actual tissue temperatures reached with AI-guided HPSD ablation appeared to be higher with a greater distance between the catheter tip and target tissue than those with standard ablation. HPSD ablation for <7 s may help prevent collateral tissue injury when ablating within a close distance.