Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
1.
Folia Morphol (Warsz) ; 83(1): 192-199, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-37345390

RESUMO

BACKGROUND: The temporomandibular joint is one of the most complex anatomic structures. It takes a great role in masticatory system and helps to make possible some functions such as speaking, chewing and swallowing. Clinicians should have sufficient anatomical knowledge to assess relationships of the hard and soft tissues, including the mandibular condyle, glenoid fossa, articular eminence of the temporal bone, the articular disc and its attachments. The aim of this study was to evaluate the frequency of different types of mandibular condyles and its distribution according to the age and gender. It was also evaluated whether the condyle types were bilaterally symmetrical or not. MATERIALS AND METHODS: A total of 1315 digital panoramic images which obtained from the patients suffering from the dental problems were assessed. Demographic data, condylar morphology were noted. All obtained data were analysed by using descriptive statistics. Morphology of mandibular condyles were classified into four shapes as identified in other studies, namely: type I - oval shape, type II - diamond shape, type III - bird beak shape, type IV - crooked finger shape. Two independent examiners, who have 19 and 7 years of experience in oral and dentomaxillofacial radiology, made a consensus and evaluated all images. RESULTS: A total of 1315 digital panoramic images were assessed. Seven hundred sixty-seven [58.3%] the patients were female and 548 [41.6%] were male. The age range of patients was from 18 to 84 years. Right-left condyle types were found to be symmetrical in the range of 67% of the subpopulation examined in the study. For the consensus, 'oval' condyle was common on both the right and left, while 'crooked finger' condyle was the rarest. CONCLUSIONS: The temporomandibular joint is the most important structure for all jaw functions such as speech, swallowing. In order for all these functions to continue in a healthy way, the anatomical structure should be known very well down to the finest detail. Identification of anatomical structures and their variations can play an important role in implant dentistry. Clinicians commonly prefer conventional radiologic methods to evaluate dentomaxillofacial region. Although the most of the variations are asymptomatic and require no treatment,correct identification of these findings will reduce unnecessary further diagnostic assessments and will provide more appropriate treatment plans.


Assuntos
Côndilo Mandibular , Articulação Temporomandibular , Humanos , Masculino , Feminino , Adolescente , Adulto Jovem , Adulto , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Radiografia Panorâmica , Estudos Retrospectivos , Articulação Temporomandibular/diagnóstico por imagem , Articulação Temporomandibular/anatomia & histologia , Côndilo Mandibular/diagnóstico por imagem , Osso Temporal
2.
Dent Med Probl ; 60(1): 127-135, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37023340

RESUMO

BACKGROUND: Cone-beam computed tomography (CBCT) is used to provide multiplanar views of the temporomandibular joint (TMJ) bone components as well as TMJ pathologies without superposition, magnification or distortion. OBJECTIVES: The study aimed to analyze degenerative changes in the condylar surface, and their relationship with patient age and gender, and the TMJ space measurements by using CBCT images. MATERIAL AND METHODS: A total of 258 individuals were retrospectively analyzed. The degenerative bone changes of the condylar head were evaluated and classified on the right and left sides. The shortest distances from the anterior, superior and posterior parts of the condylar head to the glenoid fossa were measured to represent the TMJ space. Univariate and multivariate logistic regression analyses then evaluated the effect of age and gender on the presence of degenerative changes. RESULTS: Condylar flattening was most frequently observed (413 TMJs, 53.5%). However, the presence or absence of the change types did not differ according to the sides. The mean values of the TMJ space measurements on the right and left sides were narrower in the group with changes than in the group without changes. Nonetheless, no statistically significant difference in the TMJ space was found between the groups (p > 0.05). CONCLUSIONS: An increased risk of radiographically detectable degenerative alterations in left TMJs was detected for males and for increasing age. Degenerative changes in the condylar surface may affect the dimensions of the TMJ space.


Assuntos
Tomografia Computadorizada de Feixe Cônico Espiral , Transtornos da Articulação Temporomandibular , Masculino , Humanos , Côndilo Mandibular/diagnóstico por imagem , Estudos Retrospectivos , Transtornos da Articulação Temporomandibular/diagnóstico por imagem , Transtornos da Articulação Temporomandibular/patologia , Articulação Temporomandibular/diagnóstico por imagem
3.
BMC Med Imaging ; 23(1): 46, 2023 03 28.
Artigo em Inglês | MEDLINE | ID: mdl-36978007

RESUMO

BACKGROUND: The aim of the study is to determine the distribution, location, diameter, and distance measurements of Canalis Sinusosus (CS) in relation with age and sex. METHODS: 300 Cone-Beam Computed Tomography (CBCT) images were evaluated. The distance between CS and nasal cavity floor (NCF), buccal cortical bone margin (BCM), alveolar ridge (AR), respectively.The presence of CS smaller than 1 mm, and the diameter of CS larger than 1 mm were determined. Accessory canals (AC) were classified according to their position relative to the teeth. RESULTS: 435 CS with a diameter of at least 1 mm and 142 CS < 1 mm were identified. The most frequently observed location of CS was the region of the right central incisors. The mean diameter of the canals ( CS ≥ 1) was 1.31 ± 0.19 on the right side and 1.29 ± 0.17 on the left side. No gender differences were found in canal diameter were observed (p > 0.05). There was no significant difference between men and women in the distance between CS and the NCF on the right side, and a significant difference was found in the distance of CS-NCF on the left side (p = 0.047). There were no significant differences between age groups in all parameters. CONCLUSION: CBCT is a useful tool for identifying CS. Location and diameter of ACs could not be associated with a specific age group or sex.


Assuntos
Tomografia Computadorizada de Feixe Cônico , Maxila , Masculino , Humanos , Feminino , Estudos Retrospectivos , Maxila/diagnóstico por imagem , Processo Alveolar , Fatores Sexuais
4.
J Oral Rehabil ; 50(5): 360-369, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36794633

RESUMO

OBJECTIVE: This study aimed to compare the trabecular internal structure of different regions of the mandible according to the grades of appositional classification in the mandible angle region in probable bruxist individuals and non-bruxist G0(Convex course of the basal cortex, no directional change, no bone apposition) individuals by measuring fractal dimension (FD) on panoramic radiographs. METHODS: 200 sample jaws, bilaterally, of 80 probable bruxists and 20 non-bruxist G0 individuals were included in the study. According to the classification in the literature, each mandible angle apposition severity was classified as G0-G1-G2-G3. FD was calculated by selecting the region of interest (ROI) area of 7 regions from each sample. Gender differences in changes between ROIs in radiographs and independent samples t-test were evaluated. Relation between categorical variables was determined by chi-square test (p < .05). RESULTS: In the comparison of the probable bruxist and non-bruxist G0 groups, FD was found to be statistically significantly higher in the mandible angle (p = 0.013) and cortical bone (p = 0.000) regions in the probable bruxist group than in the non-bruxist G0 group. There is a statistically significant difference between probable bruxist G0 and non-bruxist G0 grades in terms of FD averages in cortical bone (p < 0.001). A statistically significant difference was found in the relationship of ROIs with gender in canine apex (p = 0.021) and canine distal (p = 0.041) regions. CONCLUSION: FD was found to be higher in the mandibular angle region and cortical bone in probable bruxist individuals than in non-bruxist G0 individuals. Morphological changes seen in the mandible angulus region may be a finding that may raise suspicion for bruxism for clinicians.


Assuntos
Bruxismo , Osso Esponjoso , Humanos , Osso Esponjoso/diagnóstico por imagem , Fractais , Mandíbula/diagnóstico por imagem , Radiografia
5.
Oral Radiol ; 39(3): 544-552, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-36504381

RESUMO

OBJECTIVE: This study aims to evaluate whether there is a relationship between the appositional classification in the mandible angle region and the mandibular cortical index (MCI) seen in bruxist individuals and to differentiate between the bruxist group without mandibular apposition and the non-bruxist group on panoramic radiographs. METHODS: The mandible angle region of 209 individuals, 170 bruxists and 39 non-bruxists, were included in the study. Each mandible angle apposition was classified as G0 (No directional change, no bone apposition)-G1 (Directional change on the basal cortex. No bone apposition)-G2 (Directional change plus generalized bone apposition with inhomogeneous surface)-G3 (Directional change plus localized bone apposition at one or more sites). The MCI of each individual was recorded according to their classified apposition. RESULTS: No statistically significant difference was found in the relationship between MCI and apposition severity in mandible angle grades in bruxist individuals (p = 0.063). A statistically significant difference was found between MCI and the bruxist G0/non-bruxist G0 groups (p < 0.001). While the MCI-C1 was higher in non-bruxist G0 individuals, the MCI-C2 was higher in bruxist G0 individuals. A statistically significant correlation was found between gender and severity of grades (p < 0.001). CONCLUSION: Although it is known that appositional changes are seen in the mandible angle region in bruxism, MCI can be used as a valuable radiologic diagnostic criterion during the evaluation of bruxist and healthy individuals in the G0 grade who have not yet radiologically demonstrated bone apposition in the mandible angle.


Assuntos
Bruxismo , Humanos , Radiografia Panorâmica , Radiografia , Mandíbula/diagnóstico por imagem , Cabeça
7.
Oral Radiol ; 38(3): 325-335, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-34387842

RESUMO

OBJECTIVE: The aim of this study is to assess the effects of metal artifact reduction (MAR) and adaptive image noise enhancer (AINO) in CBCT imaging on the detection accuracy of artificially created fenestration defects in proximity to titanium and zirconium implants in sheep jaw. METHODS: Six zirconium and 10 titanium implants were planted on mandibular jaws of three sheep, and artificial defects were created. All images were obtained with a standard voxel size (0.150 mm3) and with 4 scan modes: (1) without MAR/without AINO; (2) with MAR/without AINO; (3) without MAR/with AINO; and (4) with MAR/with AINO during CBCT scanning. A total of 60 CBCT scans were produced. RESULTS: For all types of implants, intra- and inter-observer kappa values were the highest for MAR filter. The scan mode of with MAR filter was found to have the highest area under the curve (AUC), whereas the scan mode of without both MAR and AINO filters was found to have the lowest AUC values with statistical significance (p ≤ 0.05). Titanium implants were found to have higher AUC values than zirconium (p ≤ 0.05). CONCLUSION: Both MAR module and AINO filters enhance the accuracy of the detection of peri-implant fenestrations; however, the use of MAR filter solely can be recommended for detection of peri-implant fenestrations.


Assuntos
Artefatos , Zircônio , Algoritmos , Animais , Tomografia Computadorizada de Feixe Cônico/métodos , Ovinos , Titânio
8.
J Ultrason ; 21(86): e206-e212, 2021 Aug 16.
Artigo em Inglês | MEDLINE | ID: mdl-34540274

RESUMO

Background: The aim of the present study was to evaluate the efficacy of intraoral and extraoral ultrasonography evaluations performed with two different types of probes (linear and "hockey stick") for the visibility of peri-implant bone defects. Material and methods: Fourteen implants were inserted into sheep heads. Peri-implant bone defects were created without knowing the depth, which served as the gold standard for the defects. The defects were scanned with two different probe types (linear and hockey stick probes) extraorally and intraorally, using two different ultrasonography systems. For intra- and interobserver agreements for each probe types, Kappa coefficients were calculated. Results: The lowest ICC values were found in both intra- (ICC = 0.696) and interobserver reliability (ICC = 0.762) obtained with the extraorally used linear probe. There was a high agreement with the gold standard when using hockey sticky probes intraorally. For both linear probes, there were no significant differences in agreement among the two observers and the gold standard (p >0.05). Conclusions: High agreement was found when using high-frequency hockey stick probes intraorally, which means that they can be used with good effect for the evaluation of the visibility of peri-implant bone defects. To the best of our knowledge, this study is the first one on this subject. Thus, it can be stated that US can be an alternative method of examining defects. However, further studies are needed to evaluate the effectiveness of US in visualizing peri-implant bone defects.

9.
J Ultrason ; 21(86): e237-e243, 2021 Aug 16.
Artigo em Inglês | MEDLINE | ID: mdl-34540279

RESUMO

Aim of the study: The present preliminary study aims to evaluate the possible positive outcomes of ultrasonography-guided sialolithotomies and duct stricture dilations utilizing stone retrieval baskets and guide wires. Case description: A total of 6 cases in an ongoing study (4 cases of sialolithiasis and 2 cases of duct strictures with intraluminal adhesion) were analyzed. All sialoliths were <5 mm in diameter. Stone removals and duct dilations were performed under ultrasonography guidance with two different types of linear probes. Edema measurements were carried out, and the area of edema was evaluated via the echogenicity changes. Patient satisfaction was also evaluated by the patients themselves using a Visual Analog Scale questionnaire on postoperative day 0, and on days 1, 2, and 3. Conclusions: There were no postoperative complications, and mouth openings returned to normal at 7-day follow-up. The pain scores decreased after 6 hours, and pain subsided completely after 12 hours in all the patients. Edema also resolved gradually after the operation. The patient satisfaction levels were high.

10.
Int J Implant Dent ; 6(1): 58, 2020 Oct 02.
Artigo em Inglês | MEDLINE | ID: mdl-33006000

RESUMO

BACKGROUND: To examine the influence of voxel sizes to detect of peri-implant fenestration defects on cone beam computed tomography (CBCT) images. MATERIALS AND METHODS: This study performed with three sheep heads both maxilla and mandible and two types of dental implant type 1 zirconium implant (Zr40) (n = 6) and type 2 titanium implant (Ti22) (n = 10). A total of 14 peri-implant fenestrations (8 buccal surfaces, 6 palatal/lingual surface) were created while 18 surfaces (8 buccal, 10 palatal/lingual) were free of fenestrations. Three observers have evaluated the images of fenestration at each site. Images obtained with 0.75 mm3, 0.100 mm3, 0.150 mm3, 0.200 mm3, and 0.400 mm3 voxel sizes. For intra- and inter-observer agreements for each voxel size, Kappa coefficients were calculated. RESULTS: Intra- and inter-observer kappa values were the highest for 0.150 mm3, and the lowest in 0.75 mm3 and 0.400 mm3 voxel sizes for all types of implants. The highest area under the curve (AUC) values were found higher for the scan mode of 0.150 mm3, whereas lower AUC values were found for the voxel size for 0.400 mm3. Titanium implants had higher AUC values than zirconium with the statistical significance for all voxel sizes (p ≤ 0.05). CONCLUSION: A voxel size of 0.150 mm3 can be used to detect peri-implant fenestration bone defects. CBCT is the most reliable diagnostic tool for peri-implant fenestration bone defects.

11.
Artigo em Inglês | MEDLINE | ID: mdl-29273196

RESUMO

OBJECTIVE: This study assessed the use of different voxel resolutions in a cone beam computed tomography (CBCT) unit for the detection of artificially induced periodontal bone defects created using burr, burr and chemicals, and only chemicals. STUDY DESIGN: Seven dry skulls were used in this study. In total, 65 dehiscence defects, 43 fenestration defects, and 76 control sites with no periodontal defects were examined. Images were obtained from a CBCT unit (3 D Accuitomo; J Morita Mfg. Corp., Kyoto, Japan), using 3 field-of-view (FOV) sizes (4 × 4 cm; 6 × 6 cm; and 8 × 8 cm) and 4 scan modes (standard, high-definition, high-fidelity, and low-dose). RESULTS: Overall, κ coefficients for interobserver agreement on burr-induced periodontal defects ranged from 0.336 to 0.795, with the lowest κ value (indicating a fair degree of agreement) obtained for images acquired in standard mode with a voxel size of 0.160 mm3. κ coefficients for the detection of periodontal defects were highest (indicating moderate to high degrees of interobserver agreement) for smaller voxel sizes and high-resolution images. Statistical comparison among groups (burr, burr + chemicals, and chemicals only) was performed using 1-way analysis of variance with post hoc tests. CONCLUSIONS: The CBCT scan mode may affect the diagnosis of periodontal defects. The technique used to create periodontal defects also affected diagnosis. For this kind of experiment, burr-induced or burr + chemical-induced defects should be used, rather than those induced solely using a chemical technique.


Assuntos
Processo Alveolar/diagnóstico por imagem , Tomografia Computadorizada de Feixe Cônico , Doenças Periodontais/diagnóstico por imagem , Humanos , Técnicas In Vitro , Percloratos , Crânio/diagnóstico por imagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA