Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Int Angiol ; 41(5): 405-412, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-36264097

RESUMO

BACKGROUND: This study aimed to assess the efficacy and safety of Actovegin for the treatment of patients with Fontaine stage IIB peripheral arterial disease (PAD). METHODS: The study included 366 patients with Fontaine stage IIB PAD from 19 centers (Russia, Georgia, Kazakhstan). Placebo or Actovegin (1200 mg daily [QD]) were administered intravenously for two weeks, followed by a 10-week course of oral administration (placebo or Actovegin 1200 mg QD). The primary efficacy outcome was percentage change in the initial claudication distance (ICD) by week 12. Secondary outcomes included percent and absolute changes in ICD, absolute claudication distance (ACD) and changes in Quality of Life (QoL) assessed by the SF-36 Mental Health Score. RESULTS: The increase in ICD after 12 weeks of Actovegin treatment was 29.19% (LS mean [Actovegin vs. placebo]; 95% CI: 9.35-49.02; P=0.0041). The percentage increase in ICD at 24 weeks was 35.51% (LS mean; 95% CI: 10.96-60.05; P=0.0047), which correspond to an increase in absolute ICD of 41.22 m (LS mean; 95% CI: 16.77-65.66; P=0.0010). The percentage increase in ACD after 24 weeks was 36.47% compared with the baseline (LS mean; 95% CI: 10.07-62.88; P=0.0069), which corresponded to an absolute increase in ACD of 50.92 m (LS mean; 95% CI: 18.35-83.49; P=0.0023). A statistically significant improvement in QoL with Actovegin compared with placebo was demonstrated within 24 weeks (LS mean 2.28; 95% CI: 0.88-3.68; P=0.0015). Actovegin demonstrated an acceptable safety and tolerability profile with minor differences from placebo. CONCLUSIONS: The results of this 12-week course of Actovegin demonstrated its superiority over placebo in the increase in ICD and ACD at weeks 2, 12 and 24 from the start of treatment. Actovegin has an acceptable safety and tolerability profile.


Assuntos
Claudicação Intermitente , Doenças Vasculares Periféricas , Humanos , Heme/uso terapêutico , Claudicação Intermitente/diagnóstico , Claudicação Intermitente/tratamento farmacológico , Qualidade de Vida , Caminhada
2.
Lasers Surg Med ; 54(4): 611-622, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-34918347

RESUMO

OBJECTIVES: The development of compact diagnostic probes and instruments with an ability to direct access to organs and tissues and integration of these instruments into surgical workflows is an important task of modern physics and medicine. The need for such tools is essential for surgical oncology, where intraoperative visualization and demarcation of tumor margins define further prognosis and survival of patients. In this paper, the possible solution for this intraoperative imaging problem is proposed and its feasibility to detect tumorous tissue is studied experimentally. METHODS: For this aim, the sapphire scalpel was developed and fabricated using the edge-defined film-fed growth technique aided by mechanical grinding, polishing, and chemical sharpening of the cutting edge. It possesses optical transparency, mechanical strength, chemical inertness, and thermal resistance alongside the presence of the as-grown hollow capillary channels in its volume for accommodating optical fibers. The rounding of the cutting edge exceeds the same for metal scalpels and can be as small as 110 nm. Thanks to these features, sapphire scalpel combines tissue dissection with light delivering and optical diagnosis. The feasibility for the tumor margin detection was studied, including both gelatin-based tissue phantoms and ex vivo freshly excised specimens of the basal cell carcinoma from humans and the glioma model 101.8 from rats. These tumors are commonly diagnosed either non-invasively or intraoperatively using different modalities of fluorescence spectroscopy and imaging, which makes them ideal candidates for our feasibility test. For this purpose, fiber-based spectroscopic measurements of the backscattered laser radiation and the fluorescence signals were carried out in the visible range. RESULTS: Experimental studies show the feasibility of the proposed sapphire scalpel to provide a 2-mm-resolution of the tumor margins' detection, along with an ability to distinguish the tumor invasion region, which results from analysis of the backscattered optical fields and the endogenous or exogenous fluorescence data. CONCLUSIONS: Our findings justified a strong potential of the sapphire scalpel for surgical oncology. However, further research and engineering efforts are required to optimize the sapphire scalpel geometry and the optical diagnosis protocols to meet the requirements of oncosurgery, including diagnosis and resection of neoplasms with different localizations and nosologies.


Assuntos
Óxido de Alumínio , Neoplasias , Animais , Humanos , Lasers , Margens de Excisão , Fibras Ópticas , Imagens de Fantasmas , Ratos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA