RESUMO
Vesicoureteral reflux (VUR) is a common congenital anomaly of the urinary tract that can present with collecting system dilation or as a febrile infection. VUR can lead to permanent renal sequela requiring surgery but can also spontaneously resolve without complication. Therefore, it is important to recognize those patient populations who warrant imaging for screening, confirmation, or ongoing surveillance for VUR, while avoiding overdiagnosis. In the appropriate patient populations, an accurate diagnosis of VUR allows early treatment and prevention of pyelonephritis and scarring. Various imaging modalities are available to diagnose and grade VUR, including voiding cystourethrogram (VCUG), radionucleotide cystography (RNC), and contrast-enhanced voiding urosonography (ceVUS). The objective of this article is to summarize the current understanding of VUR diagnosis and management and to discuss these imaging modalities' strengths and pitfalls. Considerations include indications for VUR imaging, patient preparation, conduct of the examination, issues related to radiologic reporting, and cost-effectiveness. An emphasis is placed on ceVUS, which is the most recently introduced of the three imaging modalities and is receiving growing support among pediatric radiologists.
RESUMO
In this white paper, the ACR Pediatric AI Workgroup of the Commission on Informatics educates the radiology community about the health equity issue of the lack of pediatric artificial intelligence (AI), improves the understanding of relevant pediatric AI issues, and offers solutions to address the inadequacies in pediatric AI development. In short, the design, training, validation, and safe implementation of AI in children require careful and specific approaches that can be distinct from those used for adults. On the eve of widespread use of AI in imaging practice, the group invites the radiology community to align and join Image IntelliGently (www.imageintelligently.org) to ensure that the use of AI is safe, reliable, and effective for children.
Assuntos
Inteligência Artificial , Radiologia , Adulto , Humanos , Criança , Sociedades Médicas , Radiologia/métodos , Radiografia , Diagnóstico por Imagem/métodosRESUMO
PURPOSE: Ultrasound of the right lower quadrant for appendicitis requires specific training and practice. Improved visualization of the appendix can result in decreased utilization of computed tomography. Increasing the sensitivity of ultrasound for appendicitis thus decreases radiation exposure, reduces cost, and improves the patient healthcare experience in accordance with the three principles of the triple aim designated by the Institute for Healthcare Improvement. The purpose of this study was to examine the effect of a structured training program supplemented by technologist feedback on sonographic visualization of the appendix in a large pediatric health system. METHODS: The baseline ultrasound visualization frequency was computed for 20 ultrasound technologists in a large pediatric health system. Following this, technologists were informed of their individual and relative performance. Those with visualization frequencies less than 75% were provided structured training by a designated sonographer with an appendix visualization frequency above 75% while those with greater than 75% visualization continued to be monitored and informed of their monthly frequency. Following this structured training, appendix visualization frequencies were monitored over the next 5 months. RESULTS: There was no significant effect of sonographer career experience on the baseline appendix visualization frequency. Fourteen of 20 technologists demonstrated improved visualization frequencies post-intervention. The composite visualization frequency among these 20 technologists improved from 66.55 to 69.14%. This resulted in a potential savings of 38 CT scans during the post-intervention period. CONCLUSION: An appendix visualization rate monitoring program coupled with structured training was successful in improving the appendix visualization rate throughout a large pediatric health system. This program demonstrates the positive effect that monitoring and targeted intervention can have on a quality improvement program. The program continues to be carried out as part of a plan-study-do-act cycle.
Assuntos
Apendicite , Apêndice , Tutoria , Criança , Humanos , Apêndice/diagnóstico por imagem , Melhoria de Qualidade , Estudos Retrospectivos , UltrassonografiaRESUMO
Electronic cigarette or vaping product use-associated lung injury (EVALI) is a toxic inhalational injury that surged in late 2019 and early 2020, immediately prior to the coronavirus disease 2019 (COVID-19) pandemic. Although EVALI cases have significantly decreased, they are still encountered, especially among adolescents. While several characteristic imaging findings and patterns of EVALI have been described, some of them can overlap with the imaging features of COVID-19 pneumonia. We provide a comprehensive review of EVALI that includes the latest updates and highlight the important role of radiologists as contributors to the appropriate and timely care of pediatric patients with this diagnosis.
Assuntos
COVID-19 , Sistemas Eletrônicos de Liberação de Nicotina , Lesão Pulmonar , Vaping , Adolescente , Criança , Humanos , Lesão Pulmonar/diagnóstico por imagem , Pandemias , Vaping/efeitos adversosRESUMO
Ultrasound (US) has been increasingly used as an important imaging tool to assess the urethra in children. The earliest reports of pediatric urethral sonography involved imaging the urethra in a non-voiding state, during physiological voiding of urine, and after instillation of saline. The introduction of US contrast agents has continued to improve visualization of urethral anatomy. Contrast-enhanced US of the urethra can be performed during the voiding phase of a standard contrast-enhanced voiding urosonography (ceVUS) exam or with retrograde instillation of a contrast agent, depending on the exam indication. Both techniques are well tolerated by children and provide accurate information about urethral pathology and periurethral soft tissues. This article reviews the technical aspects and imaging findings of urethral pathologies in children using contrast-enhanced US, both by the voiding and retrograde instillation techniques.
Assuntos
Uretra , Micção , Criança , Meios de Contraste , Diagnóstico por Imagem , Humanos , Masculino , Ultrassonografia , Uretra/diagnóstico por imagemRESUMO
The addition of contrast US to an existing pediatric US service requires several preparatory steps. This overview provides a guide to simplify the process. Initially, it is important to communicate to all stakeholders the justifications for pediatric contrast US, including (1) its comparable or better diagnostic results relative to other modalities; (2) its reduction in procedural sedation or anesthesia by avoiding MRI or CT; (3) its reduction or elimination of radiation exposure by not having to perform fluoroscopy or CT; (4) the higher safety profile of US contrast agents (UCA) compared to other contrast agents; (5) the improved exam comfort and ease inherent to US, leading to better patient and family experience, including bedside US exams for children who cannot be transported; (6) the need for another diagnostic option in light of increasing demand by parents and providers; and (7) its status as an approved and reimbursable exam. It is necessary to have an UCA incorporated into the pharmacy formulary noting that only SonoVue/Lumason is currently approved for pediatric use. In the United States this UCA is approved for intravenous administration for cardiac and liver imaging and for vesicoureteric reflux detection with intravesical application. In Europe and China it is only approved for the intravesical use in children. All other applications are off-label. The US scanner needs to be equipped with contrast-specific software. The UCA has to be prepared just before the exam and it is important to strictly follow the steps as outlined in the packaging inserts in order to prevent premature destruction of the microbubbles. The initial training in contrast US is best focused on the frontline staff actually performing the US studies; these might be sonographers, pediatric or interventional radiologists, or trainees. It is important from the outset to educate the referring physicians about contrast US. It is helpful to participate in existing contrast US courses, particularly those with hands-on components.
Assuntos
Meios de Contraste , Refluxo Vesicoureteral , Criança , Fluoroscopia , Humanos , Microbolhas , UltrassonografiaRESUMO
Contrast-enhanced ultrasound (CEUS) is increasingly being used in children. One of the most common referrals for CEUS performance is characterization of indeterminate focal liver lesions and follow-up of known liver lesions. In this setting, CEUS is performed with intravenous administration of ultrasound contrast agents (UCAs). When injected into a vein, UCA microbubbles remain confined within the vascular network until they dissipate. Therefore, visualization of UCA within the tissues and lesions corresponds to true blood flow. CEUS enables continuous, real-time observation of the enhancement pattern of a focal liver lesion, allowing in most cases for a definite diagnosis and obviating the need for further cross-sectional imaging or other interventional procedures. The recent approval of Lumason (Bracco Diagnostics, Monroe Township, NJ) for pediatric liver CEUS applications has spurred the widespread use of CEUS. In this review article we describe the role of CEUS in pediatric liver applications, focusing on the examination technique and interpretation of main imaging findings of the most commonly encountered benign and malignant focal liver lesions. We also compare the diagnostic performance of CEUS with other imaging modalities for accurate characterization of focal liver lesions.
Assuntos
Neoplasias Hepáticas , Criança , Meios de Contraste , Humanos , Fígado/diagnóstico por imagem , Neoplasias Hepáticas/diagnóstico por imagem , Microbolhas , UltrassonografiaRESUMO
Contrast-enhanced voiding urosonography (ceVUS) is a well-established, sensitive and safe ultrasound (US) modality for detecting and grading vesicoureteral reflux (VUR) and urethral imaging in children. Nearly three decades of remarkable advances in US technology and US contrast agents have refined ceVUS's diagnostic potential. The recent approval of Lumason/SonoVue in the United States, Europe and China for pediatric intravesical applications marked the beginning of a new era for this type of contrast US imaging. Consequently, the use of ceVUS in children has expanded to multiple places around the globe. In the first part of this review article, we describe the current experience in the use of ceVUS for VUR evaluation, with an emphasis on historical background, examination technique, image interpretation and diagnostic accuracy. In the second part, we will present the role of ceVUS for urethral imaging in children.
Assuntos
Refluxo Vesicoureteral , Criança , Meios de Contraste , Humanos , Lactente , Masculino , Ultrassonografia , Uretra , Micção , Refluxo Vesicoureteral/diagnóstico por imagemRESUMO
DESCRIPTION OF THE PROBLEM: Wait time from request to placement of ports in interventional radiology had increased from 14 to 27 days over a 4-month period. The goal of this project was to reduce the wait time by 15% within 4 months while accommodating additional volume. INSTITUIONAL APPROACH TO ADDRESS PROBLEM: Capacity analysis revealed 2 bottlenecks: (1) inadequate provider capacity for preprocedural visits in interventional radiology clinic and (2) inadequate number of spots for port placement in the angiography schedule. The intervention consisted of: (1) 2 reserved slots in the attending physician's morning clinic schedule and (2) 3 daily guaranteed spots for port placement in the angiography suite. Both changes were integrated into the electronic medical record scheduling system. DESCRIPTION OF OUTCOMES: After the intervention, per biweekly period, the number of port requests increased by 17% (Preintervention: 16.6 ± 3.1, Postintervention: 20.1 ± 4.1, Pâ¯=â¯0.03), the number of completed clinic visits increased by 19% (Preintervention: 16.7 ± 5.1, Postintervention: 20.5 ± 3.6, Pâ¯=â¯0.05), and the number of port placements increased by 19% (Preintervention: 16.9 ± 3.9, Postintervention: 21.0 ± 3.5, Pâ¯=â¯0.02). The average wait time from request to placement decreased by 22% (Preintervention: 22.2 ± 4.4 days, Postintervention: 18.3 ± 3.4 days, Pâ¯=â¯0.03), driven by a 49% decrease in wait time between request and clinic visit (Preintervention: 11.0 ± 2.3 days, Postintervention: 7.4 ± 1.0 days, Pâ¯=â¯0.03). CONCLUSIONS: Prioritization of clinic and angiography suite capacity, integrated into the electronic scheduling system, significantly reduced the wait time for port placement, even with significant increases in the volume of port requests.
Assuntos
Instituições de Assistência Ambulatorial , Listas de Espera , Angiografia , HumanosRESUMO
The coronavirus disease 2019 (COVID-19) pandemic has necessitated rapid response plans to minimize risks of infection in the workforce while ensuring maintenance of essential functions of radiology departments. Plan adoption is, however, challenged by the need to coordinate with institutional efforts, a rapidly expanding number of patients, and the diversity of clinical and administrative functions in the department. Here, we describe the implementation of a response plan in an academic radiology department, challenges encountered, and tactics used to address these challenges.
Assuntos
Infecções por Coronavirus/epidemiologia , Infecções por Coronavirus/prevenção & controle , Infecção Hospitalar/prevenção & controle , Controle de Infecções/organização & administração , Transmissão de Doença Infecciosa do Paciente para o Profissional/prevenção & controle , Exposição Ocupacional/prevenção & controle , Pandemias/prevenção & controle , Pneumonia Viral/epidemiologia , Pneumonia Viral/prevenção & controle , Serviço Hospitalar de Radiologia/organização & administração , Gestão da Segurança , Betacoronavirus , COVID-19 , Humanos , Fatores de Risco , SARS-CoV-2 , Texas/epidemiologiaRESUMO
BACKGROUND: We describe a quality improvement project to improve patient dwell times for outpatient cardiac nuclear medicine exams. Preliminary data indicated that the mean patient dwell time was about 270 minutes. Our specific, measurable, achievable, relevant, and time-bound goal was to reduce patient dwell times for outpatient pharmacologically stressed cardiac nuclear medicine exams by 60 minutes over the course of 2 months. METHODS: An interdisciplinary team was formed which used staff interviews and workflow observation to create a cause and effect diagram as well as a process map. Review of the national guidelines for cardiac nuclear medicine exams identified rest and stress intervals as intervention targets. A new protocol was designed and implemented. RESULTS: The mean patient dwell time was improved from 270 to 184 minutes. CONCLUSIONS: Overall, we found that a clear specific, measurable, achievable, relevant, and time-bound goal, limited scope, and national guideline review allowed for a successful quality improvement project.
Assuntos
Assistência Ambulatorial/organização & administração , Doenças Cardiovasculares/diagnóstico por imagem , Medicina Nuclear/normas , Melhoria de Qualidade , Humanos , Objetivos Organizacionais , Guias de Prática Clínica como Assunto , Avaliação de Processos em Cuidados de Saúde , Sociedades Médicas , Fatores de Tempo , Fluxo de TrabalhoRESUMO
Background Electronic cigarette or vaping product use-associated lung injury (EVALI) is a serious public health concern with substantial morbidity and mortality, particularly in young individuals. Purpose To evaluate chest radiographic and chest CT findings of EVALI in the pediatric population. Materials and Methods This was a retrospective study of children who presented to a tertiary pediatric hospital from December 2018 to December 2019. Patients fulfilled the Centers for Disease Control and Prevention criteria for EVALI and had chest radiographs and CT images available at initial presentation. Two pediatric radiologists independently reviewed imaging for pattern, distribution, and extent of pulmonary abnormalities, as well as for extrapulmonary abnormalities. Clinical information, management, and outcomes were reviewed. Interobserver agreement was measured with Cohen κ coefficient. Results Seven male patients (50%) and seven female patients (50%) (mean age, 16 years; range, 13-18 years) were evaluated. All patients underwent chest radiography and CT within 4 days of presentation (range, 0-4 days). Chest radiographic findings included ground-glass opacity in 14 of 14 (100%) and consolidation in eight of 14 (57%). CT findings included ground-glass opacity in 14 of 14 (100%), consolidation in nine of 14 (64%), and interlobular septal thickening in two of 14 (14%). At CT, subpleural sparing was seen in 11 of 14 (79%) and a reversed halo sign was seen in five of 14 (36%). Chest radiographic and CT abnormalities were predominately bilateral in 14 of 14 (100%) and symmetric in 13 of 14 (93%), with lower lobe predominance in seven of 14 (50%). Extent of abnormality was predominately diffuse at both chest radiography and CT. There was almost perfect interobserver agreement between two reviewers for detecting abnormalities on chest radiographs (κ = 0.99; 95% confidence interval: 0.97, 1.00) and CT (κ = 0.99; 95% confidence interval: 0.98, 1.00). Conclusion In pediatric patients, electronic cigarette or vaping product use-associated lung injury is characterized by bilateral symmetric ground-glass opacities, consolidation, and a lower lobe predominance at CT. © RSNA, 2020.
Assuntos
Sistemas Eletrônicos de Liberação de Nicotina , Lesão Pulmonar/induzido quimicamente , Lesão Pulmonar/diagnóstico por imagem , Radiografia Torácica , Tomografia Computadorizada por Raios X , Vaping/efeitos adversos , Adolescente , Feminino , Humanos , Masculino , Estudos Retrospectivos , Estados UnidosRESUMO
OBJECTIVES: To inform selective and efficient use of appendix ultrasound (US) beyond adult parameters of body mass index (BMI) of less than 25 kg/m, we correlate abdominal wall thickness (AWT) with age and BMI to generate parameters for male and female children. Information presented in chart format can aid in the decision to utilize US for the evaluation of appendicitis. METHODS: In this observational study, 1600 pediatric computed tomography scans of the abdomen and pelvis were analyzed to obtain measurements of AWT in the right lower quadrant. Measurements were correlated by patient age, BMI, and sex. Results and consensus-based recommendations were presented in chart format with color-coded groupings to allow for convenient referencing in the clinical setting. RESULTS: One thousand four hundred eighty-eight computed tomography scans and AWT measurements were included. All age groups with BMI of less than 25 kg/m and all male and female groups younger than 6 years regardless of BMI had median AWT of less than 4 cm resulting in strong recommendation for US. Males older than 6 years and all female age groups with BMI of greater than 30 kg/m and female older than 15 years and BMI of greater than 25 kg/m had AWT of more than 5 cm resulting in low recommendation for US. CONCLUSIONS: While the BMI cutoff standard of less than 25 kg/m for usefulness of appendix US holds in the adult population, our data expand the acceptable range in children younger than 9 years regardless of BMI and male children with BMI up to 30 kg/m. Female children younger than 15 years with a BMI up to 30 kg/m may also be amenable to right lower quadrant US based on AWT. These parameters inform selective and efficient use of US for appendix evaluation.
Assuntos
Parede Abdominal/fisiologia , Apendicite/diagnóstico por imagem , Apêndice/diagnóstico por imagem , Adolescente , Índice de Massa Corporal , Criança , Pré-Escolar , Feminino , Humanos , Masculino , Tomografia Computadorizada por Raios X , UltrassonografiaRESUMO
PURPOSE: The purpose of this quality improvement initiative was to study the effect of providing scorecards to emergency department providers to assess its effect on changes in utilization. METHODS: CT of the abdomen and pelvis, CT angiogram of the chest for pulmonary embolism, and CT of the head were targeted due to ordering variability, cost, and radiation exposure. The utilization rate for each provider was assessed for emergency department providers. Following this, providers were given scorecards regarding their utilization as well as their relative utilization compared with each other. Utilization was then monitored following the intervention to assess the effect of the scorecard on ordering practices. RESULTS: No significant effect on the utilization of these 3 exams was found after the scorecard intervention. CONCLUSION: Providing scorecards to make emergency department providers aware of their relative utilization does not significantly alter ordering behavior. Incentive-based systems may be required in order to lessen overutilization of these 3 commonly ordered radiology procedures in the emergency department.
Assuntos
Serviço Hospitalar de Emergência/estatística & dados numéricos , Padrões de Prática Médica/estatística & dados numéricos , Tomografia Computadorizada por Raios X/estatística & dados numéricos , Angiografia por Tomografia Computadorizada/estatística & dados numéricos , Feminino , Hospitais de Condado , Humanos , Masculino , Grupo Associado , Melhoria de QualidadeRESUMO
The canal of Nuck, caused by the failed closure of the processus vaginalis in the female, is the continued outpouching of parietal peritoneum through the inguinal canal to the labia majora. Disorders of the canal of Nuck include hernia and hydrocele. Some canal of Nuck hernias, especially of the ovary, may result in emergent complications such as incarceration, strangulation, and ovarian torsion. Knowledge of canal of Nuck disorders and prompt diagnosis are important to avoid serious complications. Imaging, especially ultrasound, is essential for timely diagnosis, leading to appropriate management and better patient care.
RESUMO
OBJECTIVE: The purpose of this study is to describe our experience with pathologically proven breast masses at a tertiary care pediatric institution, review published management strategies, and propose new management recommendations for the pediatric population. MATERIALS AND METHODS: All pediatric breast ultrasound examinations performed at a dedicated pediatric facility over a 4-year period were reviewed. Maximum measurements of solid masses with features of a fibroadenoma were recorded. The subsequent management and histopathologic findings for patients undergoing biopsy were reviewed, and management strategies were compared with published recommendations. RESULTS: Of 277 breast masses with features typical of fibroadenomas, 115 (42%) underwent pathologic evaluation. All were benign; there were 107 simple fibroadenomas, four juvenile fibroadenomas, three benign phyllodes tumors, and one granular cell tumor. Simple fibroadenomas ranged in size from 0.9 to 9.1 cm and were statistically significantly different in size compared with juvenile fibroadenomas and phyllodes tumors (range, 1.7-12.5 cm). All 47 masses undergoing follow-up ultrasound before tissue diagnosis were fibroadenomas; five showed 50% or greater interval growth. The retrospective application of published pediatric breast management criteria yielded no difference in sensitivity for the detection of nonsimple fibroadenoma masses. CONCLUSION: Management of pediatric breast masses resembling fibroadenomas at sonography can be based on size and interval growth rate. The routine performance of surgical excision or biopsy of masses with ultrasound characteristics typical of fibroadenomas is not recommended.
Assuntos
Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/patologia , Fibroadenoma/diagnóstico por imagem , Fibroadenoma/patologia , Palpação , Adolescente , Criança , Humanos , Estudos Retrospectivos , Ultrassonografia Mamária , Adulto JovemRESUMO
Granular cell tumor is an exceedingly rare pediatric breast mass, derived from Schwann cells which are most commonly observed in the oral cavity, skin, and subcutaneous tissue. When they occur in the breast, they can mimic intrinsic breast masses. Most cases are benign, but malignant cases have been reported. We present a case of a premenstrual, African-American 9â¯year old female with a painful right breast mass originally felt to be an epidermal inclusion cyst. An ultrasound was performed 17â¯months after original presentation which demonstrated a 1â¯cm well-circumscribed solid ovoid mass. Despite the relatively small size and benign imaging appearance of the mass, surgical resection was performed for symptom relief given the associated pain. This is the first known case of granular cell tumor of the breast in a premenstrual female.
Assuntos
Neoplasias da Mama/diagnóstico , Mama/diagnóstico por imagem , Tumor de Células Granulares/diagnóstico , Pré-Menopausa , Ultrassonografia Mamária/métodos , Biópsia , Criança , Feminino , HumanosAssuntos
Eficiência Organizacional , Melhoria de Qualidade/organização & administração , Radiografia Intervencionista/métodos , Tomografia Computadorizada por Raios X/métodos , Comunicação , Registros Eletrônicos de Saúde/organização & administração , Humanos , Capacitação em Serviço/organização & administração , Cultura Organizacional , Radiografia Intervencionista/normas , Tomografia Computadorizada por Raios X/normas , Fluxo de TrabalhoRESUMO
Editor's Note.-RadioGraphics continues to publish radiologic-pathologic case material selected from the American Institute for Radiologic Pathology (AIRP) "best case" presentations. The AIRP conducts a 4-week Radiologic Pathology Correlation Course, which is offered five times per year. On the penultimate day of the course, the best case presentation is held at the American Film Institute Silver Theater and Cultural Center in Silver Spring, Md. The AIRP faculty identifies the best cases, from each organ system, brought by the resident attendees. One or more of the best cases from each of the five courses are then solicited for publication in RadioGraphics. These cases emphasize the importance of radiologic-pathologic correlation in the imaging evaluation and diagnosis of diseases encountered at the institute and its predecessor, the Armed Forces Institute of Pathology (AFIP).