RESUMO
BACKGROUND: Islet transplantation has been associated with better metabolic control and quality of life than insulin treatment alone, but direct evidence of its effect on hard clinical endpoints is scarce. We aimed to assess the effect of islet transplantation on patient-graft survival in kidney transplant recipients with type 1 diabetes. METHODS: In this retrospective cohort study, we enrolled all patients with type 1 diabetes who received a kidney graft in France during the study period, identified from the CRISTAL nationwide registry. Non-inclusion criteria included recipients from transplant centres that never proposed islet transplantation during the study period, recipients with a functional pancreas throughout the follow-up duration, recipients with more than two kidney transplants, HLA-sensitised recipients, recipients with less than 1 year of follow-up after kidney transplantation, misclassified recipients with type 2 diabetes, recipients aged over 65 years, recipients of kidney grafts from Donation after Circulatory Death donors, recipient with HIV or hepatitis, recipients with cancer, and recipients of combined liver-kidney transplants. Patients who also received islet-after-kidney (IAK) transplantation were compared with controls who received kidney transplantation alone according to a 1:2 matching method based on time-dependent propensity scores, ensuring patients comparability at the time of islet transplantation. The primary outcome was patient-graft survival, a composite outcome defined by death, re-transplantation, or return to dialysis. FINDINGS: Between Jan 1, 2000, and Dec 31, 2017, 2391 patients with type 1 diabetes were identified as having received a kidney transplant, 47 patients of whom also received an islet transplantation. 2002 patients were not eligible for islet transplantation and 62 were excluded due to missing data. 327 eligible recipients from 15 centres were included in the study dataset for the target trial emulation. 40 patients who received IAK transplantation were successfully matched to 80 patients who received kidney transplantation alone. 13 (33%) of 40 patients in the IAK transplantation group returned to dialysis or died, compared with 36 (45%) of 80 patients in the kidney transplantation alone group. We found a significant benefit of islet transplantation compared with kidney transplantation alone on patient-graft survival, with a hazard ratio (HR) of 0·44 (95% CI 0·23-0·88; p=0·022), mainly explained by a protective effect on the risk of death (HR 0·41, 0·13-0·91; p=0·042). There was no meaningful association between IAK and death-censored graft survival (0·73, 0·30-1·89; p=0·36). INTERPRETATION: In kidney transplant recipients with type 1 diabetes, IAK transplantation was associated with a significantly better patient-graft survival compared with kidney transplantation alone, mainly due to a protective effect on the risk of death. These results potentially serve as compelling grounds for advocating wider access to islet transplantation in patients with type 1 diabetes undergoing kidney transplant, as reimbursement of islet transplantation is provided in few countries worldwide. FUNDING: Programme Hospitalier de la Recherche Clinique, Fondation pour la Recherche Medicale, and Fonds de Dotation Line Renaud-Loulou Gasté.
Assuntos
Diabetes Mellitus Tipo 1 , Sobrevivência de Enxerto , Transplante das Ilhotas Pancreáticas , Transplante de Rim , Humanos , Diabetes Mellitus Tipo 1/cirurgia , Diabetes Mellitus Tipo 1/terapia , Diabetes Mellitus Tipo 1/complicações , Masculino , Feminino , Estudos Retrospectivos , Transplante das Ilhotas Pancreáticas/métodos , França/epidemiologia , Adulto , Pessoa de Meia-IdadeRESUMO
OBJECTIVE: Continuous glucose monitoring (CGM) combined with continuous subcutaneous insulin infusion (CSII) achieves better glycemic control than multi-injection therapy in people with type 2 diabetes. The effectiveness of closed-loop therapy needs to be further evaluated in this population. RESEARCH DESIGN AND METHODS: The study objective was to measure the impact of a hybrid closed-loop device (DBLG1) compared with CSII + CGM on glycemic control in people with type 2 diabetes previously treated with CSII. The randomized, controlled, crossover, two-period, open-label, and multicenter study was conducted from August 2022 to July 2023 in 17 individuals (9 to receive 6 weeks of CSII + CGM first and 8 to receive 6 weeks of closed-loop therapy first). The primary end point was the percentage time in range (TIR: 70-180 mg/dL). Secondary outcomes were other CGM-glucose metrics, physical activity, and sleep objectively measured using 1-week actimetry. RESULTS: Data were analyzed using a modified intention-to-treat approach. Mean age was 63 (SD 9) years and 35% were women. Mean HbA1c at inclusion was 7.9% (SD 0.9). TIR increased to 76.0% (interquartile range 69.0-84.0) during the closed-loop condition vs. 61.0% (interquartile range 55.0-70.0) during the CSII + CGM condition; mean difference was 15.0 percentage points (interquartile range 8.0-22.0; P < 0.001). Analyses of secondary end points showed a decrease in time above range, in glucose management indicator, in glucose variability, and an increase in daily insulin dose. Actimetric sleep analysis showed an improvement in sleep fragmentation during closed-loop treatment. CONCLUSIONS: Closed-loop therapy improved glycemic control more than did CSII + CGM in people with type 2 diabetes.
Assuntos
Glicemia , Estudos Cross-Over , Diabetes Mellitus Tipo 2 , Hipoglicemiantes , Sistemas de Infusão de Insulina , Insulina , Humanos , Diabetes Mellitus Tipo 2/tratamento farmacológico , Diabetes Mellitus Tipo 2/sangue , Pessoa de Meia-Idade , Feminino , Masculino , Insulina/administração & dosagem , Insulina/uso terapêutico , Idoso , Hipoglicemiantes/administração & dosagem , Hipoglicemiantes/uso terapêutico , Glicemia/análise , Glicemia/efeitos dos fármacos , Automonitorização da GlicemiaRESUMO
New therapeutic approaches to treat type 1 diabetes mellitus relies on pancreatic islet transplantation. Here, developing immuno-isolation strategies is essential to eliminate the need for systemic immunosuppression after pancreatic islet grafts. A solution is the macro-encapsulation of grafts in semipermeable matrixes with a double function: separating islets from host immune cells and facilitating the diffusion of insulin, glucose, and other metabolites. This study aims to synthesize and characterize different types of gelatin-collagen matrixes to prepare a macro-encapsulation device for pancreatic islets that fulfill these functions. While natural polymers exhibit superior biocompatibility compared to synthetic ones, their mechanical properties are challenging to reproduce. To address this issue, we conducted a comparative analysis between photo-crosslinked gelatin matrixes and chemically crosslinked collagen matrixes. We show that the different crosslinkers and polymerization methods influence the survival and glucose-stimulated insulin production of pancreatic ß cells (INS1) in vitro, as well as the in vitro and in vivo stability of the matrix and the immuno-isolation in vivo. Among the matrixes, the stiff multilayer GelMA matrixes (8.5 kPa), fabricated by digital light processing, were the best suited for pancreatic ß cells macro-encapsulation regarding these parameters. Within the alveoli of this matrix, pancreatic ß cells spontaneously formed aggregates.
Assuntos
Gelatina , Células Secretoras de Insulina , Transplante das Ilhotas Pancreáticas , Células Secretoras de Insulina/metabolismo , Animais , Transplante das Ilhotas Pancreáticas/métodos , Gelatina/química , Ratos , Colágeno/metabolismo , Insulina/metabolismo , Diabetes Mellitus Tipo 1/terapia , Diabetes Mellitus Tipo 1/metabolismo , Sobrevivência Celular , Humanos , Materiais Biocompatíveis , Glucose/metabolismoRESUMO
The achievement of glycemic management is challenging in patients with diabetes on enteral nutrition, limited literature exists on hybrid closed-loop systems' efficacy in such a situation. We described the case of a patient with type 1 diabetes treated by advanced hybrid closed loop on enteral nutrition with satisfactory glycemic management.
Assuntos
Glicemia , Diabetes Mellitus Tipo 1 , Nutrição Enteral , Sistemas de Infusão de Insulina , Humanos , Diabetes Mellitus Tipo 1/sangue , Diabetes Mellitus Tipo 1/complicações , Diabetes Mellitus Tipo 1/terapia , Nutrição Enteral/métodos , Glicemia/análise , Glicemia/metabolismo , Insulina/administração & dosagem , Insulina/uso terapêutico , Controle Glicêmico/métodos , Masculino , Hipoglicemiantes/uso terapêutico , Hipoglicemiantes/administração & dosagem , Adulto , FemininoRESUMO
Calcineurin inhibitors (CNIs) are critical in preventing rejection posttransplantation but pose an increased risk of post-transplant diabetes (PTD). Recent studies show that late conversion from CNIs to belatacept, a costimulation blocker, improves HbA1c in kidney transplant recipients with PTD or de novo diabetes. This study investigates whether the observed effects on PTD stem solely from CNI withdrawal or if belatacept influences PTD independently. The study assessed the impact of tacrolimus and belatacept on insulin secretion in MIN6 cells (a beta cell line) and rat islets. Tacrolimus and belatacept were administered to the cells and islets, followed by assessments of cell viability and insulin secretion. Tacrolimus impaired insulin secretion without affecting cell viability, while belatacept showed no detrimental effects on either parameter. These findings support clinical observations of improved HbA1c upon switching from tacrolimus to belatacept. Belatacept holds promise in islet or pancreas transplantation, particularly in patients with unstable diabetes. Successful cases of islet transplantation treated with belatacept without severe hypoglycemia highlight its potential in managing PTD. Further research is needed to fully understand the metabolic changes accompanying the transition from CNIs to belatacept. Preserving insulin secretion emerges as a promising avenue for investigation in this context.
Assuntos
Abatacepte , Imunossupressores , Insulina , Tacrolimo , Tacrolimo/uso terapêutico , Tacrolimo/farmacologia , Abatacepte/uso terapêutico , Abatacepte/farmacologia , Animais , Ratos , Insulina/metabolismo , Imunossupressores/uso terapêutico , Imunossupressores/farmacologia , Humanos , Masculino , Secreção de Insulina/efeitos dos fármacos , Camundongos , Transplante das Ilhotas Pancreáticas/métodos , Linhagem Celular , Sobrevivência Celular/efeitos dos fármacos , Diabetes Mellitus/tratamento farmacológico , Diabetes Mellitus/metabolismo , Ilhotas Pancreáticas/efeitos dos fármacos , Ilhotas Pancreáticas/metabolismoRESUMO
Introduction: Diabetes is a global health concern characterized by chronic hyperglycemia resulting from insulinopenia and/or insulin resistance. The rising prevalence of diabetes and its associated complications (ulcers, periodontitis, healing of bone defect, neuropathy, retinopathy, cardiopathy and nephropathy) necessitate innovative therapeutic approaches. Photobiomodulation (PBM), involves exposing tissues and cells to low-energy light radiation, leading to biological effects, largely via mitochondrial activation. Methods: This review evaluates preclinical and clinical studies exploring the potential of PBM in diabetes and its complications, as well all clinical trials, both planned and completed, available on ClinicalTrials database. Results: This review highlights the variability in PBM parameters across studies, hindering consensus on optimal protocols. Standardization of treatment parameters and rigorous clinical trials are needed to unlock PBM's full therapeutic potential. 87 clinical trials were identified that investigated PBM in diabetes mellitus (with 5,837 patients planned to be treated with PBM). Clinical trials assessing PBM effects on diabetic neuropathy revealed pain reduction and potential quality of life improvement. Studies focusing on wound healing indicated encouraging results, with PBM enhancing angiogenesis, fibroblast proliferation, and collagen density. PBM's impact on diabetic retinopathy remains inconclusive however, requiring further investigation. In glycemic control, PBM exhibits positive effects on metabolic parameters, including glucose tolerance and insulin resistance. Conclusion: Clinical studies have reported PBM-induced reductions in fasting and postprandial glycemia without an increased hypoglycemic risk. This impact of PBM may be related to its effects on the beta cells and islets in the pancreas. Notwithstanding challenges, PBM emerges as a promising adjunctive therapy for managing diabetic neuropathy, wound healing, and glycemic control. Further investigation into its impact on diabetic retinopathy and muscle recovery is warranted.
Assuntos
Diabetes Mellitus , Neuropatias Diabéticas , Retinopatia Diabética , Resistência à Insulina , Terapia com Luz de Baixa Intensidade , Humanos , Terapia com Luz de Baixa Intensidade/métodos , Qualidade de VidaRESUMO
Aim: To evaluate the evolution of glycemic outcomes in patients living with type 1 diabetes (T1D) after 1 year of use of the MiniMed 780G advanced hybrid closed-loop (AHCL) system. Methods: We conducted an observational, retrospective, multicentric study in 20 centers in France. The primary objective was to evaluate the improvement in glycemic control after 1-year use of AHCL. The primary endpoint was the variation of time in range (TIR) between pre-AHCL and after 1-year use of AHCL. Secondary objectives were to analyze the glycemic outcomes after 3, 6, and 12 months of AHCL use, the safety, and the long-term observance of AHCL. Results: Two hundred twenty patients were included, and 200 were analyzed for the primary endpoint. 92.7% of patients continued to use AHCL. After 1 year of use of AHCL, TIR was 72.5% ± 10.6% (+9.1%; 95% confidence interval [CI] [7.6-10.5] compared to pre-AHCL initiation, P < 0.001), HbA1c 7.1% ± 0.7% (-0.5%; 95% CI [-0.6 to -0.4]; P < 0.001), time below range 2.0% [1.0; 3.0] (0.0% [-2.0; 0.0], P < 0.001), and time above range 24.8% ± 10.9% (-7.3%; 95% CI [-8.8 to -5.7]; P < 0.001). More patients achieved the glycemic treatment goals of HbA1c <7.0% (45.1% vs. 18.1%, P < 0.001) and TIR >70% (59.0% vs. 29.5% P < 0.001) when compared with pre-AHCL. Five patients experienced severe hypoglycemia events and two patients experienced ketoacidosis. Conclusion: After 1 year of use of AHCL, people living with T1D safely improved their glucose control and a higher proportion of them achieved optimal glycemic control.
Assuntos
Automonitorização da Glicemia , Glicemia , Diabetes Mellitus Tipo 1 , Controle Glicêmico , Hipoglicemiantes , Sistemas de Infusão de Insulina , Insulina , Humanos , Diabetes Mellitus Tipo 1/tratamento farmacológico , Diabetes Mellitus Tipo 1/sangue , Estudos Retrospectivos , Masculino , Feminino , França , Adulto , Glicemia/análise , Hipoglicemiantes/uso terapêutico , Hipoglicemiantes/administração & dosagem , Controle Glicêmico/métodos , Insulina/administração & dosagem , Insulina/uso terapêutico , Pessoa de Meia-Idade , Hemoglobinas Glicadas/análise , Resultado do Tratamento , Hipoglicemia/prevenção & controle , Hipoglicemia/induzido quimicamenteRESUMO
Background: Evaluate the impact of the MiniMed™ 780G advanced hybrid closed-loop (AHCL) system on the glucose profile of pregnant women with type 1 diabetes (T1D) and maternal-neonatal complications. Methods: From April 2021 to September 2022, pregnant women with T1D treated with the AHCL system were included in an observational multicenter retrospective study. Continuous glucose monitoring parameters were analyzed monthly during pregnancy as well as maternal-neonatal complications. Results: Thirteen pregnant women, including a twin pregnancy (age: 33 ± 3 years, hemoglobin A1c [HbA1c]: 7.3% ± 0.7%, insulin doses: 0.72 ± 0.21 U/kg/day) were analyzed. At delivery, gestational age was 37 ± 2 weeks. During first 2 weeks of pregnancy, time in range (TIR, 63-140 mg/dL) was 46% (34-55) and increased to 54% (51-59) (P < 0.01), 64% (48-68) (P < 0.01), and 66% (60-70) (P < 0.001) during the first, second, and third trimester, respectively. During the night, TIR (63-140 mg/dL) was >70% throughout pregnancy. Time below the range <63 mg/dL increased from 0.5% (0-2) to 1.3% (0.7-2.2), 2% (1.2-3.5) (P < 0.05), and 1.3% (1.31-3) (P < 0.05) during the first, second, and third trimester, respectively. At delivery, insulin doses increased to 0.89 ± 0.35 IU/kg/day (P < 0.01), and HbA1c decreased to 6.4% ± 0.6% (P = 0.005). The reported carbohydrate amount increased from 167 ± 363 g/d during early pregnancy to 243 ± 106 g/d (P < 0.01) at delivery. The birthweight was 3134 ± 711 g, with 5/14 macrosomia and 2/14 neonatal hypoglycemia. Moreover, 5/13 patients had a preeclampsia and 9/13 a cesarean section, including three cases of scarred uterus. The Clinical Trial Registration number is: CE-2022-55. Conclusion: The AHCL system provided good glucose control during pregnancy and recommendation targets were reached during the nocturnal period only. The maternal and neonatal complications remained high.
Assuntos
Diabetes Mellitus Tipo 1 , Gravidez em Diabéticas , Adulto , Feminino , Humanos , Recém-Nascido , Gravidez , Glicemia , Automonitorização da Glicemia , Cesárea , Diabetes Mellitus Tipo 1/tratamento farmacológico , Glucose , Hemoglobinas Glicadas , Hipoglicemiantes/administração & dosagem , Insulina/administração & dosagem , Sistemas de Infusão de Insulina/efeitos adversos , Gravidez em Diabéticas/tratamento farmacológico , Gestantes , Estudos RetrospectivosRESUMO
Islet transplantation improves metabolic control in patients with unstable type 1 diabetes. Clinical outcomes have been improving over the last decade, and the widely used beta-score allows the evaluation of transplantation results. However, predictive pre-transplantation criteria of islet quality for clinical outcomes are lacking. In this proof-of-concept study, we examined whether characterization of the electrical activity of donor islets could provide a criterion. Aliquots of 8 human donor islets from the STABILOT study, sampled from islet preparations before transplantation, were characterized for purity and split for glucose-induced insulin secretion and electrical activity using multi-electrode-arrays. The latter tests glucose concentration dependencies, biphasic activity, hormones, and drug effects (adrenalin, GLP-1, glibenclamide) and provides a ranking of CHIP-scores from 1 to 6 (best) based on electrical islet activity. The analysis was performed online in real time using a dedicated board or offline. Grouping of beta-scores and CHIP-scores with high, intermediate, and low values was observed. Further analysis indicated correlation between CHIP-score and beta-score, although significance was not attained (R = 0.51, p = 0.1). This novel approach is easily implantable in islet isolation units and might provide means for the prediction of clinical outcomes. We acknowledge the small cohort size as the limitation of this pilot study.
Assuntos
Diabetes Mellitus Tipo 1 , Transplante das Ilhotas Pancreáticas , Ilhotas Pancreáticas , Humanos , Insulina/metabolismo , Glicemia/análise , Projetos Piloto , Transplante das Ilhotas Pancreáticas/métodos , Diabetes Mellitus Tipo 1/cirurgia , Glucose/metabolismo , Glucose/farmacologiaRESUMO
BACKGROUND: DBLG1 (Diabeloop Generation 1) stands as one of the five commercially available closed-loop solution worldwide for patients with type 1 diabetes as of 2023. Our aim was to provide an overview of all data obtained with this system regarding outcomes and populations, with an emphasis on interoperability. METHODS: This report includes all available sources of data (three randomized control trials and five surveys on real-life data). Collection ran from March 3, 2017 to April 30, 2022. RESULTS: We gathered data from 6859 adult patients treated with closed-loop from three to 12 months. Overall, all sources of data showed that time in range (TIR) 70 to 180 mg/dL, starting from 47.4% to 56.6%, improved from 12.2 to 17.3 percentage points. Time in hypoglycemia was reduced by 48% in average (range: 26%-70%) and reached a level of 1.3% in the largest and most recent cohort. In patients with excessive time in hypoglycemia at baseline (≥5%), closed-loop allowed a reduction in time below range (TBR) by 59%. The comparison of days with declared physical activity versus days without physical activity did not show differences in TBR. The improvement in TIR observed with three different pump systems (Vicentra Kaleido, n = 117; Sooil Dana-I, n = 84; and Roche Insight, n = 6684) ranged from 15.4 to 17.3 percentage points. DISCUSSION: These data obtained in different European countries were consistent throughout all reports, showing that this closed-loop system is efficient (high improvement in TIR), safe (remarkably low level of TBR), and interoperable (three pump settings so far).
Assuntos
Diabetes Mellitus Tipo 1 , Hipoglicemia , Adulto , Humanos , Diabetes Mellitus Tipo 1/tratamento farmacológico , Insulina/uso terapêutico , Hipoglicemiantes/uso terapêutico , Glicemia , Sistemas de Infusão de Insulina/efeitos adversos , Hipoglicemia/induzido quimicamente , Insulina Regular Humana/uso terapêuticoRESUMO
Insulin pump therapy improves glycaemic control in individuals with type 2 diabetes. However, it may be associated with weight gain. AIM: To test the effectiveness of a six-month dietary and physical activity intervention, compared to usual care, on weight gain prevention after initiation of insulin pump. METHODS: Multicentre randomized, controlled trial of 54 individuals. Primary endpoint was between group difference in weight gain at six-months. RESULTS: Weight gain after 6 months of insulin pump treatment did not differ between groups: mean 3.2 (3.9) kg in the control group and 3.9 (3.8) kg in the intervention group, (p = 0.56). HbA1c improved without difference between groups. Post-hoc multivariate analysis of all participants found that weight gain was independently associated with younger age, active smoking, and the magnitude of HbA1c reduction. A 1 % decrease in HbA1c was associated with an increase of 0.94 kg [95 % Confidence Interval 0.47; 1.41], p < 0.001. CONCLUSIONS: Treatment intensification by insulin pump therapy in patients with type 2 diabetes is effective to improve glycaemic control. A gain of about 1 kg per 1 % drop in HbA1c can be expected after insulin treatment intensification. This weight gain was not prevented by a home-base, individualized, 6-months lifestyle intervention program.
Assuntos
Diabetes Mellitus Tipo 2 , Humanos , Diabetes Mellitus Tipo 2/tratamento farmacológico , Diabetes Mellitus Tipo 2/prevenção & controle , Diabetes Mellitus Tipo 2/induzido quimicamente , Hipoglicemiantes , Insulina , Hemoglobinas Glicadas , Aumento de Peso , Estilo de VidaRESUMO
According to the latest statistics, more than 537 million people around the world struggle with diabetes and its adverse consequences. As well as acute risks of hypo- or hyper- glycemia, long-term vascular complications may occur, including coronary heart disease or stroke, as well as diabetic nephropathy leading to end-stage disease, neuropathy or retinopathy. Therefore, there is an urgent need to improve diabetes management to reduce the risk of complications but also to improve patient's quality life. The impact of continuous glucose monitoring (CGM) is well recognized, in this regard. The current review aims at introducing the basic principles of glucose sensing, including electrochemical and optical detection, summarizing CGM technology, its requirements, advantages, and disadvantages. The role of CGM systems in the clinical diagnostics/personal testing, difficulties in their utilization, and recommendations are also discussed. In the end, challenges and prospects in future CGM systems are discussed and non-invasive, wearable glucose biosensors are introduced. Though the scope of this review is CGMs and provides information about medical issues and analytical principles, consideration of broader use will be critical in future if the right systems are to be selected for effective diabetes management.
Assuntos
Glicemia , Diabetes Mellitus , Humanos , Automonitorização da Glicemia , Diabetes Mellitus/diagnóstico , GlucoseRESUMO
AIM: The aim of this study was to determine the prevalence of likely eating disorders and insulin misuse in a prospective cohort of adults with type 1 diabetes mellitus (T1DM) treated with insulin pump therapy. METHODS: This prospective study was held at the participants' home. The participants completed the SCOFF questionnaire as well as a question related to insulin misuse. Information about lifestyle, medical history, insulin pump and Continuous Glucose Monitoring (CGM) data were collected. RESULTS: The analysis covered 198 participants with a median age of 51 [95% CI 38; 62] years. The prevalence of likely eating disorders was 21.7% (95% CI 16.3; 28.2) in the study population and 20.6% (95% CI 14.3; 28.6) and 24.2% (95% CI 14.6; 37.0) in males and females respectively. The prevalence of insulin misuse was 39.0% (95% CI 30.8; 47.7). There was no significant difference in prevalence between males and females for likely eating disorders and insulin misuse. The analysis of CGM data revealed no factors related to glycaemic control associated with likely eating disorders. CONCLUSION: The results of this study indicate that the prevalence of likely eating disorders is high even in a middle-aged population with a T1DM and satisfactory glucose control.
Assuntos
Diabetes Mellitus Tipo 1 , Transtornos da Alimentação e da Ingestão de Alimentos , Adulto , Masculino , Pessoa de Meia-Idade , Feminino , Humanos , Diabetes Mellitus Tipo 1/tratamento farmacológico , Diabetes Mellitus Tipo 1/epidemiologia , Diabetes Mellitus Tipo 1/complicações , Estudos Prospectivos , Automonitorização da Glicemia/métodos , Prevalência , Glicemia , Insulina/uso terapêutico , Sistemas de Infusão de Insulina , Transtornos da Alimentação e da Ingestão de Alimentos/epidemiologia , Transtornos da Alimentação e da Ingestão de Alimentos/complicações , Insulina Regular Humana/uso terapêutico , Hipoglicemiantes/uso terapêuticoRESUMO
OBJECTIVES: To assess the diagnostic performances of CZT myocardial perfusion reserve (MPR) for the detection of territories with simultaneous impaired coronary flow reserve (CFR) and index of microcirculatory resistance (IMR) in patients without obstructive coronary artery disease. METHODS: Patients were prospectively included before being referred for coronary angiography. All patients underwent CZT MPR before invasive coronary angiography (ICA) and coronary physiology assessment. Rest and dipyridamole-induced stress myocardial blood flow (MBF) and MPR were quantified using 99mTc-SestaMIBI and a CZT camera. Fractional flow reserve (FFR), Thermodilution CFR, and IMR were assessed during ICA. RESULTS: Between December 2016 and July 2019, 36 patients were included. 25/36 patients presented no obstructive coronary artery disease. A complete functional assessment was performed in 32 arteries. No territory presented a significant ischemia on CZT myocardial perfusion imaging. A moderate yet significant correlation was observed between regional CZT MPR and CFR (r = 0.4, P = .03). Sensitivity, specificity, positive and negative predictive value, and accuracy of regional CZT MPR versus the composite invasive criterion (impaired CFR and IMR) were 87 [47% to 99%], 92% [73% to 99%], 78% [47% to 93%], 96% [78% to 99%], and 91% [75% to 98%], respectively. All territories with a regional CZT MPR ≤ 1.8 showed a CFR < 2. Regional CZT MPR values were significantly higher in arteries with CFR ≥ 2 and IMR < 25 (negative composite criterion, n = 14) than in those with CFR < 2 and IMR ≥ 25 (2.6 [2.1 to 3.6] versus 1.6 [1.2 to 1.8]), P < .01). CONCLUSION: Regional CZT MPR presented excellent diagnostic performances for the detection of territories with simultaneously impaired CFR and IMR reflecting a very high cardiovascular risk in patients without obstructive coronary artery disease.
Assuntos
Doença da Artéria Coronariana , Reserva Fracionada de Fluxo Miocárdico , Imagem de Perfusão do Miocárdio , Humanos , Doença da Artéria Coronariana/diagnóstico por imagem , Projetos Piloto , Reserva Fracionada de Fluxo Miocárdico/fisiologia , Microcirculação/fisiologia , Angiografia Coronária , Perfusão , Imagem de Perfusão do Miocárdio/métodosAssuntos
Diabetes Mellitus Tipo 1 , Hipoglicemia , Glicemia , Estudos Cross-Over , Diabetes Mellitus Tipo 1/complicações , Diabetes Mellitus Tipo 1/tratamento farmacológico , Feminino , Humanos , Hipoglicemia/induzido quimicamente , Hipoglicemiantes/uso terapêutico , Insulina/uso terapêutico , Sistemas de Infusão de Insulina , GravidezRESUMO
INTRODUCTION: Telemedicine programs using health technological innovation to remotely monitor the lifestyles of patients with type 2 diabetes (T2D) can improve glycaemic control and thus reduce the incidence of complications as well as management costs. In this context, an assessment was made of the 1-year and 2-year cost-effectiveness of the EDUC@DOM telemonitoring and tele-education program. METHODS: The EDUC@DOM study was a multicentre randomized controlled trial conducted between 2013 and 2017 that compared a telemonitoring group (TMG) to a control group (CG) merged with health insurance databases to extract economic data on resource consumption. Economic analysis was performed from the payer perspective, and direct costs and indirect costs were considered. The clinical outcome used was the intergroup change in glycated haemoglobin (HbA1c) levels from baseline. Missing economic data were imputed using multiple imputation, and fitted values from a generalized linear mixed model were used to calculate the incremental cost-effectiveness ratio (ICER). Bootstrapped 95% confidence ellipses were drawn in the cost-effectiveness plan. RESULTS: The main analysis included data from 256 patients: 126 in the TMG and 130 in the CG. Incremental costs over 1 and 2 years were equal to 2129 and 5101, respectively, in favour of the TMG. Once imputed and adjusted for confounding factors, the TMG trends to a 21% cost decrease over 1 and 2 years of follow-up (0.79 [0.58; 1.08], p = 0.1452 and 0.79 [0.61; 1.03], p = 0.0879, respectively). The EDUC@DOM program led to a 1334 cost saving and a 0.17 decrease in HbA1c over 1 year and a 3144 cost saving and a 0.14 decrease in HbA1c over 2 years. According to the confidence ellipse, EDUC@DOM was a cost-effective strategy. CONCLUSION: This study provides additional economic information on telemonitoring and tele-education programs to enhance their acceptance and promote their use. In the light of this work, the EDUC@DOM program is a cost-saving strategy in T2D management. TRIAL REGISTRATION: This trial was registered in the Clinical Trials Database on 27 September 2013 under no. NCT01955031 and bears ID-RCB no. 2013-A00391-44.