Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
J Thorac Dis ; 15(10): 5362-5370, 2023 Oct 31.
Artigo em Inglês | MEDLINE | ID: mdl-37969264

RESUMO

Background: The clinical benefits of totally minimal invasive esophagectomy (TIME) compared to open esophagectomy are documented and include reduced morbidity like pulmonary infections, shorter hospital stay and an increase in short-term quality of life. However, transition to TIME can be associated with a learning curve associated increased morbidity. We report our implementation of TIME using a 2-step approach, where the thoracoscopic part was added to the laparoscopic part in carefully selected patients. The hypothesis was that the 2-step implementation provides a safe and efficient implementation without compromising the outcomes for the patients. The aim of this study was to evaluation the implementation of minimal invasive esophagectomy at Aarhus University Hospital, where a 2-step implementation strategy has been used. Methods: In this retrospective observational cohort study a total of 369 patients with esophagus or gastroesophageal cancers underwent esophagectomy from September 1st, 2016 to July 31st, 2021 in a single high-volume tertiary institution. Totally minimally invasive Ivor Lewis esophagectomy was performed by experienced minimal invasive surgeons in 120 of the cases. The study presents the complication rates of the TIME patients in the implementation phase. Results: Anastomotic leakage occurred in 7.5% of the cases and pneumonia occurred in 5.8% of the cases. The lymph node count reached 16 or more in 94.3% of the cases and R0-resection was performed in 98.3% of the cases. Textbook outcome for esophageal cancer surgery was achieved in 45.8% of the patients. Conclusions: Hybrid minimal invasive esophagectomy can serve as a step towards totally minimally invasive esophagectomy. In our institution, major learning curve associated complications was avoided and a high level of cancer control was achieved by a 2-step implementation strategy in carefully selected patients.

2.
Ann Cardiothorac Surg ; 8(3): 342-350, 2019 May.
Artigo em Inglês | MEDLINE | ID: mdl-31240178

RESUMO

BACKGROUND: A subvalvular annuloplasty is often used for aortic valve repair in patients with isolated aortic regurgitation with aortic annulus dilatation. Our aim was to characterize and compare annulus geometry and dynamics of the Dacron ring and suture annuloplasty and compare it with the native aortic annulus under standardized conditions. METHODS: We randomized 29 pigs of 80 kg into a Dacron ring group, a suture annuloplasty group and a native control group. The assessment was performed using sonomicrometry crystals for evaluation of dynamic geometry, and pressure measurements and echocardiography to evaluate valve performance. RESULTS: Aortic annulus area (AAA) was significantly reduced in the Dacron and Suture group compared with the Native group. Expansibility was similar and within normal physiologic limits in all three groups (Native: 12%±7%; Dacron: 11%±3%; Suture: 10%±4%). The largest segmental expansion was observed at the right coronary sinus (RC) in the Native and Dacron group but in the Suture group there was no significant difference between segments. The aortic annulus was primarily oval in systole and became more circular in diastole in the Native and Dacron group, however, in the Suture group, the sphericity remained relatively unchanged throughout the cardiac cycle. CONCLUSIONS: This study is the first to describe and compare detailed segmental geometry of the Dacron ring and suture annuloplasty in a standardized porcine model. The two annuloplasties effectively downsized the aortic annulus, while expansibility was maintained. Each annuloplasty had its own geometrical characteristics, but the Dacron ring was more similar to the native aortic annulus than the suture annuloplasty. This study suggests that the Dacron ring offers a more physiological and standardized support by mimicking the geometry and dynamics of the native aortic annulus and thus is a preferable choice over the suture annuloplasty for valve-sparing aortic root procedures.

3.
Cardiovasc Eng Technol ; 10(3): 482-489, 2019 09.
Artigo em Inglês | MEDLINE | ID: mdl-31175615

RESUMO

PURPOSE: With new repair techniques of the aortic root and valve emerging, a detailed understanding of the dynamics of the aortic annulus and valve is required for optimal results. The objective of this study was to characterize geometrical changes and force distribution of the native porcine aortic annulus throughout the cardiac cycle. METHODS: Measurements were performed in an acute 80 kg porcine model (n = 7) using sonomicrometry crystals in the aortic annulus for evaluation of geometry and dynamics, annular force transducer evaluating force distribution, and pressure measurements and echocardiography evaluating valve performance. RESULTS: Overall, segmental force distribution and geometrical changes differed between different segments of the aortic annulus. The highest force development was found at the left/right interleaflet triangle (2.87 ± 2.1 N) and the largest segmental expansion was observed at the right-coronary and left-coronary sinus. The aortic annulus changed configuration throughout the cardiac cycle and became more oval in systole. CONCLUSIONS: This study is the first to describe detailed segmental dynamics and force distribution of the native aortic annulus in a porcine model in vivo. The heterogenous behavior of the aortic annulus suggests that different segments demand different support for repair of the aortic root and valve.


Assuntos
Valva Aórtica/fisiologia , Hemodinâmica , Telemetria/instrumentação , Transdutores de Pressão , Função Ventricular Esquerda , Animais , Valva Aórtica/diagnóstico por imagem , Diástole , Ecocardiografia , Desenho de Equipamento , Modelos Animais , Sus scrofa , Sístole , Fatores de Tempo , Pressão Ventricular
4.
Interact Cardiovasc Thorac Surg ; 28(1): 112-119, 2019 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-29961835

RESUMO

OBJECTIVES: Understanding the biomechanical impact of aortic valve-sparing techniques is important in an era in which surgical techniques are developing and are increasingly being used based on biomechanical understanding that is essential in the refining of existing techniques. The objective of this study was to describe how the valve-sparing remodelling (Yacoub) and reimplantation (David Type-1) techniques affect the biomechanics of the native aortic root in terms of force distribution and geometrical changes. METHODS: Two force transducers were implanted into 22 pigs, randomized to 1 of 3 groups (David = 7, native = 7 and Yacoub = 8) along with 11 sonomicrometry crystals and 2 pressure catheters. Force and geometry data were combined to obtain the local structural stiffness in different segments of the aortic root. RESULTS: The radial structural stiffness was not different between groups (P = 0.064) at the annular level; however, the David technique seemed to stabilize the aortic annulus more than the Yacoub technique. In the sinotubular junction, the native group was more compliant (P = 0.036) with the right-left coronary segment than the intervention groups. Overall, the native aortic root appeared to be more dynamic at both the annular level and the sinotubular junction than both intervention groups. CONCLUSIONS: In conclusion, the David procedure may stabilize the aortic annulus more than the Yacoub procedure, whereas the leaflet opening area was larger in the latter (P = 0.030). No difference (P = 0.309) was found in valve-opening delay between groups. The 2 interventions show similar characteristics at the sinotubular junction, whereas the David technique seemed more restrictive at the annular level than the Yacoub technique.


Assuntos
Aorta Torácica , Aneurisma da Aorta Torácica , Insuficiência da Valva Aórtica , Valva Aórtica , Animais , Aorta Torácica/fisiopatologia , Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/complicações , Aneurisma da Aorta Torácica/fisiopatologia , Aneurisma da Aorta Torácica/cirurgia , Valva Aórtica/fisiopatologia , Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/complicações , Insuficiência da Valva Aórtica/fisiopatologia , Insuficiência da Valva Aórtica/cirurgia , Fenômenos Biomecânicos , Prótese Vascular , Modelos Animais de Doenças , Próteses Valvulares Cardíacas , Pressão , Distribuição Aleatória , Reimplante , Suínos
5.
Interact Cardiovasc Thorac Surg ; 27(6): 819-827, 2018 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-29868723

RESUMO

OBJECTIVES: Increasing evidence shows that annular stabilization is essential in most aortic valve repair procedures. However, a standardized comparison of the 2 commonly used annuloplasty procedures is lacking. We hypothesized that the Dacron ring is more rigid than the polytetrafluoroethylene suture, whereas both procedures decrease annular dimensions. The aim of this study was to compare the biomechanical properties of the ring and suture techniques with native aortic roots in vitro. METHODS: Eighteen aortic roots explanted from 80-kg pigs were randomized into a Dacron ring group, a suture annuloplasty group and a native control group. Each sample was tested in a pulsatile in vitro model with a force transducer attached to the aortic annulus to obtain radial force measurements, and annular dynamics was evaluated using 2-dimensional echography. RESULTS: Among the 2 annuloplasty procedures, only the Dacron ring group provided a significant reduction in the annular diameter compared with the native group (P < 0.006). Both annuloplasty procedures significantly reduced the geometric orifice area, tenting area and sinus diameter while increasing the coaptation length compared with the native group. Systolic annular distension was retained between groups, although the total radial forces were significantly reduced in the procedure groups compared with the native group (ring 1.07 ± 0.45 N, suture 1.13 ± 0.39 N and native 3.55 ± 1.34 N, P < 0.001). CONCLUSIONS: Although both annuloplasty procedures increase coaptation length and decrease geometric orifice area, a significant downsizing of the annulus was achieved using the Dacron ring only. The systolic annular distension was similar to the native aortic root, whereas the radial annular forces were evenly decreased by both annuloplasty procedures. Long-term studies are needed to disclose any difference in long-term effect of the annuloplasty procedures.


Assuntos
Valva Aórtica , Anuloplastia da Valva Cardíaca , Doenças das Valvas Cardíacas , Próteses Valvulares Cardíacas , Polietilenotereftalatos , Técnicas de Sutura , Suturas , Animais , Valva Aórtica/cirurgia , Fenômenos Biomecânicos , Anuloplastia da Valva Cardíaca/métodos , Modelos Animais de Doenças , Doenças das Valvas Cardíacas/cirurgia , Desenho de Prótese , Distribuição Aleatória , Técnicas de Sutura/instrumentação , Suínos