Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Proc (Bayl Univ Med Cent) ; 26(4): 373-5, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-24082412

RESUMO

Patients undergoing coronary artery bypass surgery and/or heart valve surgery using a median sternotomy approach coupled with the use of cardiopulmonary bypass often experience pulmonary complications in the postoperative period. These patients are initially monitored in an intensive care unit (ICU) but after discharge from this unit to the ward they may still have compromised pulmonary function. This dysfunction may progress to significant respiratory failure that will cause the patient to return to the ICU. To investigate the severity and incidence of respiratory insufficiency once the patient has been discharged from the ICU to the ward, this study used transcutaneous carbon dioxide monitoring to determine the incidence of unrecognized inadequate ventilation in 39 patients undergoing the current standard of care. The incidence and severity of hypercarbia, hypoxia, and tachycardia in post-cardiac surgery patients during the first 24 hours after ICU discharge were found to be high, with severe episodes of each found in 38%, 79%, and 44% of patients, respectively.

2.
Anesth Analg ; 117(1): 69-75, 2013 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-23632055

RESUMO

BACKGROUND: Current methods for monitoring ventilatory rate have limitations including poor accuracy and precision and low patient tolerance. In this study, we evaluated a new acoustic ventilatory rate monitoring technology for accuracy, precision, reliability, and the ability to detect pauses in ventilation, relative to capnometry and a reference method in postsurgical patients. METHODS: Adult patients presenting to the postanesthesia care unit were connected to a Pulse CO-Oximeter with acoustic monitoring technology (Rad-87, version 7804, Masimo, Irvine, CA) through an adhesive bioacoustic sensor (RAS-125, rev C) applied to the neck. Each subject also wore a nasal cannula connected to a bedside capnometer (Capnostream20, version 4.5, Oridion, Needham, MA). The acoustic monitor and capnometer were connected to a computer for continuous acoustic and expiratory carbon dioxide waveform recordings. Recordings were retrospectively analyzed by a trained technician in a setting that allowed for the simultaneous viewing of both waveforms while listening to the breathing sounds from the acoustic signal to determine inspiration and expiration reference markers within the ventilatory cycle without using the acoustic monitor- or capnometer-calculated ventilatory rate. This allowed the automatic calculation of a reference ventilatory rate for each device through a software program (TagEditor, Masimo). Accuracy (relative to the respective reference) and precision of each device were estimated and compared with each other. Sensitivity for detection of pauses in ventilation, defined as no inspiration or expiration activity in the reference ventilatory cycle for ≥30 seconds, was also determined. The devices were also evaluated for their reliability, i.e., the percentage of the time when each displayed a value and did not drop a measurement. RESULTS: Thirty-three adults (73% female) with age of 45 ± 14 years and weight 117 ± 42 kg were enrolled. A total of 3712 minutes of monitoring time (average 112 minutes per subject) were analyzed across the 2 devices, reference ventilatory rates ranged from 1.9 to 49.1 bpm. Acoustic monitoring showed significantly greater accuracy (P = 0.0056) and precision (P- = 0.0024) for respiratory rate as compared with capnometry. On average, both devices displayed data over 97% of the monitored time. The (0.95, 0.95) lower tolerance limits for the acoustic monitor and capnometer were 94% and 84%, respectively. Acoustic monitoring was marginally more sensitive (P = 0.0461) to pauses in ventilation (81% vs 62%) in 21 apneic events. CONCLUSIONS: In this study of a population of postsurgical patients, the acoustic monitor and capnometer both reliably monitored ventilatory rate. The acoustic monitor was statistically more accurate and more precise than the capnometer, but differences in performance were modest. It is not known whether the observed differences are clinically significant. The acoustic monitor was more sensitive to detecting pauses in ventilation. Acoustic monitoring may provide an effective and convenient means of monitoring ventilatory rate in postsurgical patients.


Assuntos
Oximetria/normas , Cuidados Pós-Operatórios/normas , Taxa Respiratória/fisiologia , Som , Adulto , Monitorização Transcutânea dos Gases Sanguíneos/instrumentação , Monitorização Transcutânea dos Gases Sanguíneos/métodos , Monitorização Transcutânea dos Gases Sanguíneos/normas , Capnografia/instrumentação , Capnografia/métodos , Capnografia/normas , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Monitorização Fisiológica/instrumentação , Monitorização Fisiológica/métodos , Monitorização Fisiológica/normas , Oximetria/instrumentação , Oximetria/métodos , Cuidados Pós-Operatórios/instrumentação , Cuidados Pós-Operatórios/métodos , Reprodutibilidade dos Testes , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA