Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
2.
Chest ; 151(5): 1011-1017, 2017 05.
Artigo em Inglês | MEDLINE | ID: mdl-28215789

RESUMO

BACKGROUND: The rates of central line-associated bloodstream infections (CLABSIs) in U.S. ICUs have decreased significantly, and a parallel reduction in the rates of total hospital-onset bacteremias in these units should also be expected. We report 10-year trends for total hospital-onset ICU-associated bacteremias at a tertiary-care academic medical center. METHODS: This was a retrospective analysis of all positive-result blood cultures among patients admitted to seven adult ICUs for fiscal year 2005 (FY2005) through FY2014 according to Centers for Disease Control and Prevention National Healthcare Safety Network definitions. The rate of change for primary and secondary hospital-onset BSIs was determined, as was the distribution of organisms responsible for these BSIs. Data from three medical, two general surgical, one combined neurosurgical/trauma, and one cardiac/cardiac surgery adult ICU were analyzed. RESULTS: Across all ICUs, the rates of primary BSIs progressively fell from 2.11/1,000 patient days in FY2005 to 0.32/1,000 patient days in FY2014; an 85.0% decrease (P < .0001). Secondary BSIs also progressively decreased from 3.56/1,000 to 0.66/1,000 patient days; an 81.4% decrease (P < .0001). The decrease in BSI rates remained significant after controlling for the number of blood cultures obtained and patient acuity. CONCLUSIONS: An increased focus on reducing hospital-onset infections at the academic medical center since 2005, including multimodal multidisciplinary efforts to prevent central line-associated BSIs, pneumonia, Clostridium difficile disease, surgical site infections, and urinary tract infections, was associated with progressive and sustained decreases for both primary and secondary hospital-onset BSIs.


Assuntos
Bacteriemia/epidemiologia , Candidemia/epidemiologia , Infecções por Bactérias Gram-Negativas/epidemiologia , Infecções por Bactérias Gram-Positivas/epidemiologia , Infecções por Pseudomonas/epidemiologia , Infecções Estafilocócicas/epidemiologia , APACHE , Centros Médicos Acadêmicos , Bacteriemia/etiologia , Hemocultura , Candidemia/etiologia , Gastroenteropatias/complicações , Infecções por Bactérias Gram-Negativas/complicações , Infecções por Bactérias Gram-Positivas/complicações , Humanos , Unidades de Terapia Intensiva , Modelos Lineares , Modelos Logísticos , Mortalidade , Infecções por Pseudomonas/complicações , Infecções Respiratórias/complicações , Estudos Retrospectivos , Infecções dos Tecidos Moles/complicações , Infecções Estafilocócicas/complicações , Infecção da Ferida Cirúrgica/complicações , Estados Unidos/epidemiologia , Infecções Urinárias/complicações
4.
Anesth Analg ; 120(4): 868-76, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24149581

RESUMO

BACKGROUND: Central line-associated bloodstream infections (CLABSIs) have decreased significantly over the last decade. Further reductions in CLABSI rates should be possible. We describe a multidisciplinary approach to the reduction of CLABSIs. METHODS: This was an observational study of critically ill patients requiring central venous catheters in 8 intensive care units in a tertiary medical center. We implemented a catheter bundle that included hand hygiene, education of providers, chlorhexidine skin preparation, use of maximum barrier precautions, a dedicated line cart, checklist, avoidance of the femoral vein for catheter insertion, chlorhexidine-impregnated dressings, use of anti-infective catheters, and daily consideration of the need for the catheter. Additional measures included root cause analyses of all CLABSIs, creation of a best practice atlas for internal jugular catheters, and enhanced education on blood culture collection. Data were analyzed using the Poisson test and regression. RESULTS: CLABSI, catheter use, and microbiology were tracked from 2004 to 2012. There was a 92% reduction in CLABSIs (95% lower confidence limit: 67.4% reduction, P < 0.0001). Central venous catheter use decreased significantly from 2008 to 2012 (P = 0.032, -151 catheters per year, 95% confidence limits: -277 to -25), whereas peripherally inserted central catheter use increased (P = 0.005, 89 catheters per year, 95% confidence limits: 50 to 127). There was no apparent association between unit-specific Acute Physiology And Chronic Health Evaluation III/IV scores and CLABSI. Three units have not had a CLABSI in more than a year. The most common organism isolated was coagulase-negative staphylococcus. Since the implementation of minocycline/rifampin catheters, no cases of methicillin-resistant Staphylococcus aureus CLABSI have occurred. CONCLUSIONS: The implementation of a standard catheter bundle combined with chlorhexidine dressings, minocycline/rifampin catheters, and other behavioral changes was associated with a sustained reduction in CLABSIs.


Assuntos
Bacteriemia/prevenção & controle , Infecções Relacionadas a Cateter/prevenção & controle , Cateterismo Venoso Central/efeitos adversos , Cateteres Venosos Centrais/efeitos adversos , Equipe de Assistência ao Paciente , Bacteriemia/epidemiologia , Infecções Relacionadas a Cateter/epidemiologia , Clorexidina/química , Cuidados Críticos , Estado Terminal , Higiene das Mãos , Humanos , Unidades de Terapia Intensiva , Comunicação Interdisciplinar , Análise de Regressão , Infecções Estafilocócicas/epidemiologia , Infecções Estafilocócicas/prevenção & controle , Staphylococcus
5.
Crit Care Med ; 42(9): 2019-28, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-24810522

RESUMO

OBJECTIVES: The primary aim of the study was to measure the test characteristics of the National Health Safety Network ventilator-associated event/ventilator-associated condition constructs for detecting ventilator-associated pneumonia. Its secondary aims were to report the clinical features of patients with National Health Safety Network ventilator-associated event/ventilator-associated condition, measure costs of surveillance, and its susceptibility to manipulation. DESIGN: Prospective cohort study. SETTING: Two inpatient campuses of an academic medical center. PATIENTS: Eight thousand four hundred eight mechanically ventilated adults discharged from an ICU. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: The National Health Safety Network ventilator-associated event/ventilator-associated condition constructs detected less than a third of ventilator-associated pneumonia cases with a sensitivity of 0.325 and a positive predictive value of 0.07. Most National Health Safety Network ventilator-associated event/ventilator-associated condition cases (93%) did not have ventilator-associated pneumonia or other hospital-acquired complications; 71% met the definition for acute respiratory distress syndrome. Similarly, most patients with National Health Safety Network probable ventilator-associated pneumonia did not have ventilator-associated pneumonia because radiographic criteria were not met. National Health Safety Network ventilator-associated event/ventilator-associated condition rates were reduced 93% by an unsophisticated manipulation of ventilator management protocols. CONCLUSIONS: The National Health Safety Network ventilator-associated event/ventilator-associated condition constructs failed to detect many patients who had ventilator-associated pneumonia, detected many cases that did not have a hospital complication, and were susceptible to manipulation. National Health Safety Network ventilator-associated event/ventilator-associated condition surveillance did not perform as well as ventilator-associated pneumonia surveillance and had several undesirable characteristics.


Assuntos
Unidades de Terapia Intensiva/estatística & dados numéricos , Pneumonia Associada à Ventilação Mecânica/epidemiologia , Vigilância em Saúde Pública/métodos , APACHE , Centros Médicos Acadêmicos/estatística & dados numéricos , Feminino , Mortalidade Hospitalar , Humanos , Tempo de Internação , Masculino , Pessoa de Meia-Idade , Segurança do Paciente , Pneumonia Associada à Ventilação Mecânica/mortalidade , Prevalência , Estudos Prospectivos , Indicadores de Qualidade em Assistência à Saúde , Fatores de Risco
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA