Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
J Med Chem ; 65(5): 4291-4317, 2022 03 10.
Artigo em Inglês | MEDLINE | ID: mdl-35179904

RESUMO

Glucokinase (GK) is a key regulator of glucose homeostasis, and its small-molecule activators represent a promising opportunity for the treatment of type 2 diabetes. Several GK activators have been advanced into clinical trials and have demonstrated promising efficacy; however, hypoglycemia represents a key risk for this mechanism. In an effort to mitigate this hypoglycemia risk while maintaining the efficacy of the GK mechanism, we have investigated a series of amino heteroaryl phosphonate benzamides as ''partial" GK activators. The structure-activity relationship studies starting from a "full GK activator" 11, which culminated in the discovery of the "partial GK activator" 31 (BMS-820132), are discussed. The synthesis and in vitro and in vivo preclinical pharmacology profiles of 31 and its pharmacokinetics (PK) are described. Based on its promising in vivo efficacy and preclinical ADME and safety profiles, 31 was advanced into human clinical trials.


Assuntos
Azetidinas , Diabetes Mellitus Tipo 2 , Hipoglicemia , Organofosfonatos , Azetidinas/uso terapêutico , Diabetes Mellitus Tipo 2/tratamento farmacológico , Glucoquinase , Humanos , Hipoglicemia/tratamento farmacológico , Hipoglicemiantes/farmacologia , Hipoglicemiantes/uso terapêutico , Organofosfonatos/farmacologia , Organofosfonatos/uso terapêutico
2.
Bioorg Med Chem Lett ; 30(7): 126955, 2020 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-32035698

RESUMO

This article describes the discovery of aryl hydroxy pyrimidinones and the medicinal chemistry efforts to optimize this chemotype for potent APJ agonism. APJ is a G-protein coupled receptor whose natural agonist peptide, apelin, displays hemodynamic improvement in the cardiac function of heart failure patients. A high throughput screen was undertaken to identify small molecule hits that could be optimized to mimic the apelin in vitro response. A potent and low molecular weight aryl hydroxy pyrimidinone analog 30 was identified through optimization of an HTS hit and medicinal chemistry efforts to improve its properties.


Assuntos
Receptores de Apelina/agonistas , Pirimidinonas/farmacologia , Descoberta de Drogas , Células HEK293 , Ensaios de Triagem em Larga Escala , Humanos , Estrutura Molecular , Pirimidinonas/síntese química , Relação Estrutura-Atividade
3.
PLoS One ; 8(2): e53192, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23383297

RESUMO

BACKGROUND: Chronic glucocorticoid excess has been linked to increased atherosclerosis and general cardiovascular risk in humans. The enzyme 11ß-hydroxysteroid dehydrogenase type 1 (11ßHSD1) increases active glucocorticoid levels within tissues by catalyzing the conversion of cortisone to cortisol. Pharmacological inhibition of 11ßHSD1 has been shown to reduce atherosclerosis in murine models. However, the cellular and molecular details for this effect have not been elucidated. METHODOLOGY/PRINCIPAL FINDINGS: To examine the role of 11ßHSD1 in atherogenesis, 11ßHSD1 knockout mice were created on the pro-atherogenic apoE⁻/⁻ background. Following 14 weeks of Western diet, aortic cholesterol levels were reduced 50% in 11ßHSD1⁻/⁻/apoE⁻/⁻ mice vs. 11ßHSD1⁺/⁺/apoE⁻/⁻ mice without changes in plasma cholesterol. Aortic 7-ketocholesterol content was reduced 40% in 11ßHSD1⁻/⁻/apoE⁻/⁻ mice vs. control. In the aortic root, plaque size, necrotic core area and macrophage content were reduced ∼30% in 11ßHSD1⁻/⁻/apoE⁻/⁻mice. Bone marrow transplantation from 11ßHSD1⁻/⁻/apoE⁻/⁻ mice into apoE⁻/⁻ recipients reduced plaque area 39-46% in the thoracic aorta. In vivo foam cell formation was evaluated in thioglycollate-elicited peritoneal macrophages from 11ßHSD1⁺/⁺/apoE⁻/⁻ and 11ßHSD1⁻/⁻/apoE⁻/⁻ mice fed a Western diet for ∼5 weeks. Foam cell cholesterol levels were reduced 48% in 11ßHSD1⁻/⁻/apoE⁻/⁻ mice vs. control. Microarray profiling of peritoneal macrophages revealed differential expression of genes involved in inflammation, stress response and energy metabolism. Several toll-like receptors (TLRs) were downregulated in 11ßHSD1⁻/⁻/apoE⁻/⁻ mice including TLR 1, 3 and 4. Cytokine release from 11ßHSD1⁻/⁻/apoE⁻/⁻-derived peritoneal foam cells was attenuated following challenge with oxidized LDL. CONCLUSIONS: These findings suggest that 11ßHSD1 inhibition may have the potential to limit plaque development at the vessel wall and regulate foam cell formation independent of changes in plasma lipids. The diminished cytokine response to oxidized LDL stimulation is consistent with the reduction in TLR expression and suggests involvement of 11ßHSD1 in modulating binding of pro-atherogenic TLR ligands.


Assuntos
11-beta-Hidroxiesteroide Desidrogenase Tipo 1/genética , 11-beta-Hidroxiesteroide Desidrogenase Tipo 1/metabolismo , Apolipoproteínas E/genética , Aterosclerose/metabolismo , Células Espumosas/metabolismo , Glucocorticoides/metabolismo , Análise de Variância , Animais , Aterosclerose/prevenção & controle , Pressão Sanguínea , Transplante de Medula Óssea , Colesterol/metabolismo , Dieta Aterogênica , Cetocolesteróis/metabolismo , Lipídeos/sangue , Masculino , Camundongos , Camundongos Knockout , Análise de Sequência com Séries de Oligonucleotídeos , Reação em Cadeia da Polimerase Via Transcriptase Reversa , Receptores Toll-Like/metabolismo
4.
Artigo em Inglês | MEDLINE | ID: mdl-18760978

RESUMO

Plasma levels of 1,5-anhydroglucitol (1-deoxyglucose), a short-term marker of glycemic control, have been measured and used clinically in Japan since the early 1990s. Plasma levels of 1,5-anhydroglucitol are typically measured using either a commercially available enzymatic kit or GC/MS. A more sensitive method is needed for the analysis of 1,5-anhydroglucitol in urine, where levels are significantly lower than in plasma. We have developed a sensitive and selective LC/MS(3) assay utilizing hydrophilic interaction liquid chromatography and ion trap mass spectrometry for the quantitative determination of 1,5-anhydroglucitol in human urine. Diluted human urine samples were analyzed by LC/MS(3) using an APCI source operated in the negative ionization mode. Use of an ion trap allowed monitoring of MS(3) transitions for both 1,5-anhydroglucitol and the internal standard which provided sufficient selectivity and sensitivity for analysis from 50 microL of human urine. Quantitation of 1,5-anhydroglucitol levels in urine was accomplished using a calibration curve generated in water (calibration range 50 ng/mL to 10 microg/mL). Method ruggedness and reproducibility were evaluated by determining the intra- and inter-day accuracies and precision of the assay, as well as the bench-top and freeze-thaw stability. For both inter- and intra-assay evaluations, the accuracy of the assay was found to be acceptable, with the concentrations of all QCs tested not deviating more than 8% from theoretical. Four-hour bench-top and freeze-thaw stabilities were also evaluated; 1,5-anhydroglucitol was found to be stable at room temperature (<18% deviation from theoretical) and during 3 freeze-thaw cycles (<1% deviation from theoretical, except at the lowest QC level). The LC/MS(3) assay was then used to successfully determine the concentration of 1,5-AG in more than 200 urine samples from diabetic patients enrolled in a clinical study.


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Desoxiglucose/urina , Diabetes Mellitus/diagnóstico , Espectrometria de Massas/métodos , Biomarcadores , Diabetes Mellitus/urina , Feminino , Humanos , Masculino , Sensibilidade e Especificidade
5.
Assay Drug Dev Technol ; 5(2): 247-64, 2007 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-17477833

RESUMO

An automated high throughput process, termed the MetFast assay, is described to assess in vitro the general microsomal cytochrome P450 beta-nicotinamide adenine dinucleotide phosphate-mediated first-pass metabolic stability of potential drug candidates as a utility for pharmaceutical profiling. Utilizing robotic protocols with a multiprobe liquid handler, compounds are incubated with liver microsomes from different species. Samples are then analyzed by in-line liquid chromatography (LC)-mass spectrometry (MS) to determine the amount of compound remaining after a certain time, which allows calculation of metabolism rates. To quantitatively assess large numbers of structurally diverse compounds by LC-MS, a strategy based on an iterative two-step process was devised. Initially compounds are qualitatively analyzed by LC-ultraviolet (UV)/MS (step 1) to determine purity (UV detection) and structural integrity (MS detection). This step ensures that only correct and verified compounds with sufficient purity are being assayed to obtain reproducible high data quality. In addition, all necessary information is gathered to automatically generate specific quantitative methods for the subsequent bioanalytical analysis of metabolic stability samples by LC-UV/MS (step 2). In-house-developed, highly flexible and sophisticated data management software, termed SmartReport, is utilized for automated qualitative and quantitative LC-MS analysis set-up, data processing, and results reporting. The integration of key aspects, inherent "universal" collision-induced dissociation settings of ion trap mass spectrometers for tandem mass spectrometric scan functions utilized for compound-specific and sensitive quantitative MS methods, generic fast-LC conditions, generic MS instrument settings, and the functionality of SmartReport software resulted in an analytical process that routinely provides reproducible high-quality metabolic stability data on structurally diverse compounds. Described here is the setup of the MetFast assay, and metabolic stability data from assay validation compounds are given.


Assuntos
Preparações Farmacêuticas/metabolismo , Cromatografia Líquida , Interpretação Estatística de Dados , Avaliação Pré-Clínica de Medicamentos , Indicadores e Reagentes , Espectrometria de Massas , NADPH-Ferri-Hemoproteína Redutase/metabolismo , Controle de Qualidade , Reprodutibilidade dos Testes , Robótica , Software , Solventes , Espectrofotometria Ultravioleta
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA