Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
J Clin Med ; 9(7)2020 Jul 09.
Artigo em Inglês | MEDLINE | ID: mdl-32660070

RESUMO

PURPOSE: To compare the reliability of five different intraoral scanners (IOSs) in the capture of implant scanbodies (SBs) and to verify the dimensional congruence between the meshes (MEs) of the SBs and the corresponding library file (LF). METHODS: A gypsum cast of a fully edentulous maxilla with six implant analogues and SBs screwed on was scanned with five different IOSs (PRIMESCAN®, CS 3700®, MEDIT i-500®, ITERO ELEMENTS 5D®, and Emerald S®). Ten scans were taken for each IOS. The resulting MEs were imported to reverse engineering software for 3D analysis, consisting of the superimposition of the SB LF onto each SB ME. Then, a quantitative and qualitative evaluation of the deviations between MEs and LF was performed. A careful statistical analysis was performed. RESULTS: PRIMESCAN® showed the highest congruence between SB MEs and LF, with the lowest mean absolute deviation (25.5 ± 5.0 µm), immediately followed by CS 3700® (27.0 ± 4.3 µm); the difference between them was not significant (p = 0.1235). PRIMESCAN® showed a significantly higher congruence than MEDIT i-500® (29.8 ± 4.8 µm, p < 0.0001), ITERO ELEMENTS 5D® (34.2 ± 9.3 µm, p < 0.0001), and Emerald S® (38.3 ± 7.8 µm, p < 0.0001). CS 3700® had a significantly higher congruence than MEDIT i-500® (p = 0.0004), ITERO ELEMENTS 5D® (p < 0.0001), and Emerald S® (p < 0.0001). Significant differences were also found between MEDIT i-500® and ITERO ELEMENTS 5D® (p < 0.0001), MEDIT i-500® and Emerald S® (p < 0.0001), and ITERO ELEMENTS 5D® and Emerald S® (p < 0.0001). Significant differences were found among different SBs when scanned with the same IOS. The deviations of the IOSs showed different directions and patterns. With PRIMESCAN®, ITERO ELEMENTS 5D®, and Emerald S®, the MEs were included inside the LF; with CS 3700®, the LF was included in the MEs. MEDIT i-500® showed interpolation between the MEs and LF, with no clear direction for the deviation. CONCLUSIONS: Statistically different levels of congruence were found between the SB MEs and the corresponding LF when using different IOSs. Significant differences were also found between different SBs when scanned with the same IOS. Finally, the qualitative evaluation revealed different directions and patterns for the five IOSs.

2.
Artigo em Inglês | MEDLINE | ID: mdl-31936096

RESUMO

Purpose: To present an experimental strategy for successfully capturing the margins of prepared single teeth with an intraoral scanner (IOS). Methods: The protocol was as follows: (1) an intraoral impression was captured with an IOS, without taking care of the visibility of the margins; (2) a partial analog impression was taken by means of a 3D-printed custom tray filled with polyvinylsiloxane light, after the removal of a retraction cord; (3) the hollow portion of the analog impression, with the preparation margins clearly visible, was scanned extraorally with the same IOS; (4) the scan of the analog impression was imported into computer-assisted-design (CAD) software, where its normals were inverted; (5) the scan with inverted normals was registered on the first intraoral scan, and replaced it; (6) the technician designed the final restoration, which was fabricated and delivered for application. The study outcomes were: (1) the marginal adaptation of the final crown; (2) the quality of interproximal contacts; and (3) the quality of occlusal contacts. Results: Thirty patients (18 males, 12 females; mean age 51.3 ± 11.6 years) were selected for this study. All these patients were restored with a monolithic translucent zirconia crown, fabricated following the aforementioned protocol. The clinical precision and the marginal adaptation of the crowns were optimal, interproximal contact points were perfect, and the only necessary adaptations were occlusal, with some minor precontacts that had to be polished. Conclusions: The present protocol seems to be compatible with the fabrication of clinically precise zirconia crowns. Further studies are needed to confirm these results.


Assuntos
Desenho Assistido por Computador , Coroas , Fotografia Dentária/métodos , Impressão Tridimensional , Dente/diagnóstico por imagem , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA