Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
J Vasc Surg ; 75(2): 651-659.e1, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34509588

RESUMO

BACKGROUND: Endovascular treatment has become the first-line strategy for peripheral arterial disease (PAD). Given the number of procedures required, any technology associated with a reduction in radiation exposure and contrast volume is highly relevant. In the present study, we evaluated whether two-dimensional (2D) fusion imaging could reduce the radiation exposure and contrast volume during endovascular treatment of occlusive PAD. METHODS: Our consecutive, retrospective, single-center, nonrandomized comparative trial included patients with PAD at the femoral, popliteal, and/or tibial level, at any clinical stage, if they were candidates for endovascular revascularization. Patients were treated with or without the EndoNaut 2D fusion imaging system (Therenva, Rennes, France) in a nonhybrid room with the same Cios Alpha mobile C-arm (Siemens, Munich, Germany). The indirect dose-area product and contrast medium volume were recorded. RESULTS: Between March 2018 and April 2020, 255 patients underwent endovascular femoropopliteal revascularization with (n = 124) or without (n = 131) 2D fusion imaging. The volume of injected contrast medium (34.7 ± 13.8 mL vs 51.3 ± 26.7 mL; P < .001) and dose-area product (8.9 ± 9.9 Gy/cm2 vs 13.5 ± 14.0 Gy/cm2; P = .003) were significantly lower for the 2D fusion imaging group than for the control group. A subgroup analysis of complex (TransAtlantic Inter-Society Consensus for the Management of Peripheral Arterial Disease C/D) lesions showed similar results. Stratification of the fusion imaging group into three subgroups, according to the procedure dates, showed no effect of a potential learning curve on the operative parameters. CONCLUSIONS: The results from the present study showed a significant reduction in the contrast volume and radiation dose for endovascular treatment of PAD when applying 2D fusion imaging technology. Overall, a reduction of >30% was observed for both operative parameters, without excessive training requirements, highlighting the potential benefits of using 2D fusion imaging when performing endovascular revascularization for PAD.


Assuntos
Angiografia por Tomografia Computadorizada/métodos , Computadores de Mão , Procedimentos Endovasculares/métodos , Artéria Femoral , Imageamento Tridimensional/instrumentação , Doença Arterial Periférica/cirurgia , Cirurgia Assistida por Computador/instrumentação , Idoso , Desenho de Equipamento , Feminino , Seguimentos , Humanos , Masculino , Doença Arterial Periférica/diagnóstico , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA