Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 55
Filtrar
1.
Clin Res Cardiol ; 2023 Dec 19.
Artigo em Inglês | MEDLINE | ID: mdl-38112746

RESUMO

BACKGROUND: Cryoballoon ablation is a widely used single-shot technique for pulmonary vein isolation (PVI) in the treatment of paroxysmal atrial fibrillation (AF). Procedural endpoints ensuring maximal PVI durability are important. OBJECTIVE: To assess the performance of cryoablation procedural markers to predict long-term PVI. METHODS: In a single center, consecutive patients who underwent redo ablation with high-density mapping for symptomatic AF recurrence after cryoballoon ablation were included and cryoballoon procedural data were collected, including temperature values at 30 and 60 s, time to isolation, nadir temperature and the velocity of temperature decline estimated with the temperature/time catch-up point (T2T-Catch-Up) defined as positive when the freeze temperature in minus degree equals the time in seconds after cryoablation initiation (e.g. - 15 °C in the first 15 s of the ablation impulse). RESULTS: 47 patients (62% male; 58.3 ± 11.2 years) were included. Overall, 38 (80.9%) patients had ≥ 1 reconnected PV. Among 186 PVs, 56 (30.1%; 1.2 per patient on average) were reconnected. Univariate analysis revealed T2T-Catch-Up in 103 (56%) and more frequent in durably isolated than in reconnected PVs (93 [72%] vs 10 [19%], p < 0.0001). Among binary endpoints, T2T-Catch-Up had the highest specificity (82%) and predictive value for durable PVI at redo ablation (90%). In multivariable analyses, absence of T2T-Catch-Up (Odds-ratio 0.12, 95% CI [0.05-0.31], p < 0.0001) and right superior PV (Odds-ratio 3.14, 95% CI [1.27-7.74], p = 0.01) were the only variables independently associated with PV reconnection. CONCLUSION: T2T-Catch-Up, a new and simple cryoballoon procedural endpoint demonstrated excellent predictive value and strong statistical association with durable PVI.

2.
J Clin Med ; 12(19)2023 Sep 29.
Artigo em Inglês | MEDLINE | ID: mdl-37834948

RESUMO

BACKGROUND: Left atrial posterior wall isolation (LAPWI) may improve rhythm control in addition to pulmonary vein isolation (PVI) in persistent atrial fibrillation (persAF) patients undergoing catheter ablation (CA). However, LAPWI may be challenging when using thermal energy sources. OBJECTIVE: This study aimed to investigate the efficacy and safety of LAPWI performed by non-thermal pulsed field ablation (PFA) in CA for persAF. METHODS: Consecutive persAF patients from two German centers were prospectively enrolled. There were two study cohorts: (1) the LAPWI cohort, which included PFA-guided (re-)PVI with LAPWI for first-time and/or repeat ablation procedures; and (2) a comparative persAF cohort with a PFA PVI-only approach without LAPWI for first-time ablation within the same timeframe. Patients were followed up by routine Holter ECGs. RESULTS: In total, 79 persistent AF patients were included in the study: 59/79 patients were enrolled in the LAPWI cohort, including 16/59 index (27%) and 43/59 repeat ablation procedures (73%). Sixteen patients (16/79; 21%) were in the PVI-only cohort without LAPWI. Of the patients treated with LAPWI, procedure time and fluoroscopy time was 91 ± 30 min and 15 ± 7 min, respectively. The acute PVI rate was 100% in all first-time ablation patients (32 patients (16 PVI only, 16 PVI plus LAPWI), 196/196 PVs). Of the 43 re-do patients in the LAPWI cohort, re-PVI was necessary in 33% (14/43) of patients (27 PVs; 1.9 PV per-patient); in 67% (29/43), all PVs were isolated, and antral ablation of the PV ostia was performed in 48% (14/29). LAPWI was performed successfully in all 59 (100%) patients of the LAPWI cohort. Two minor complications occurred. No esophageal lesion was detected in the LAPWI cohort (n = 33/59 (56%) patients underwent endoscopy). After 354 ± 197 days of follow-up, freedom from atrial arrhythmias was 79.3% (95-CI: 62-95%) in the complete LAPWI cohort (n = 14/59 (24%) on AAD: class Ic n = 9, class III n = 5). There was no difference regarding acute procedural and clinical outcome compared to the PVI-only cohort. CONCLUSION: LAPWI guided by PFA is feasible and safe in patients undergoing CA for persAF and shows favorable outcomes. In the context of durable PVI, PFA-guided LAPWI may be an effective adjunctive treatment option.

3.
J Clin Med ; 12(20)2023 Oct 17.
Artigo em Inglês | MEDLINE | ID: mdl-37892704

RESUMO

Aims-Electrocardiography (ECG) and echocardiographic left atrial (LA) parameters may be helpful to assess the risk of atrial fibrillation (AF) in embolic stroke of unknown etiology (ESUS) and could therefore guide intensity of ECG monitoring. Methods-1153 consecutive patients with ischemic stroke or transient ischemic attack (TIA) were analyzed. An internal loop recorder (ILR) was implanted in 104 consecutive patients with ESUS. Multiple morphologic P-wave parameters in baseline 12-channel ECG and echocardiographic LA parameters were measured and analyzed in patients with and without ILR-detected AF. Using logistic regression, we evaluated the predictive value of several ECG parameters and LA dimensions on the occurrence of AF. Results-In 20 of 104 (19%) patients, AF was diagnosed by ILR during a mean monitoring time of 575 (IQR 470-580) days. Patients with AF were significantly older (72 (67-75) vs. 60 (52-72) years; p = 0.001) and premature atrial contractions (PAC) were more frequently observed (40% vs. 2%; p < 0.001) during baseline ECG. All morphologic P-wave parameters did not show a significant difference between groups. There was a non-significant trend towards a larger LA volume index (31 (24-36) vs. 29 (25-37) mL/m2; p = 0.09) in AF patients. Conclusions-Age and PAC are independently associated with incident AF in ESUS and could be used as markers for selecting patients that may benefit from more extensive rhythm monitoring or ILR implantation. In our consecutive cohort of patients with ESUS, neither morphological P-wave parameters nor LA size were predictive of AF.

4.
Clin Res Cardiol ; 112(12): 1748-1753, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36401623

RESUMO

BACKGROUND: Early repolarization pattern (ERP) has been associated with idiopathic ventricular fibrillation (IVF) and with cardiovascular mortality in the general population. As there is limited data about long- term outcome of IVF, the aim of our study was to observe ventricular arrhythmia (VA) recurrences in these patients and to identify a possible correlation of VA with ECG markers of early repolarization. METHODS AND RESULTS: We investigated 56 consecutive IVF patients who received an implantable cardioverter-defibrillator for secondary prevention. ERP was defined as a J-point elevation ≥ 0.1 mV in two or more contiguous inferior or lateral leads. Markers of early repolarization were present in 32.1% of cases with a preponderance of QRS slurring (77.8%). During a mean follow-up of 41.2 months, 11 patients (19.6%) received in total 18 adequate ICD-therapies. VF was most the common cause for ICDtherapy (61.1%) but monomorphic VT also occurred in four patients. Presence of ERP was associated with a significant trend towards arrhythmia recurrences. 38.9% patients with ERP received appropriate ICD-therapies whereas only 10.5% of patients without ERP had arrhythmia recurrence (p = 0.05). Inappropriate ICD-therapies occurred in seven patients (12.5%) with a non-significant trend towards a higher incidence in patients with a transvenous ICD (p = 0.15). CONCLUSION: A significant correlation between ERP and VA recurrences in patients with IVF could be observed. Though monomorphic VA also play a role in the studied IVF-population, our data support the use of the S-ICD in this collective.


Assuntos
Desfibriladores Implantáveis , Taquicardia Ventricular , Humanos , Eletrocardiografia , Fibrilação Ventricular/diagnóstico , Fibrilação Ventricular/terapia , Arritmias Cardíacas/etiologia , Coração , Desfibriladores Implantáveis/efeitos adversos
5.
Pharmacology ; 107(11-12): 608-614, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36174497

RESUMO

INTRODUCTION: Hormone-mediated therapies are on the rise and are key therapies in the treatment of some of the most common cancer entities. Proarrhythmic effects have been described in patients treated with SERMs while little to none is known about the electrophysiological effects of the potentially less arrhythmogenic selective estrogen receptor degraders. METHODS: Twenty hearts of female New Zealand White rabbits were excised and retrogradely perfused employing a Langendorff setup. An electrophysiology study was performed to obtain CL-dependent action potential duration at 90% of repolarization (APD90), QT interval, effective refractory period (ERP), and post-repolarization refractoriness (PRR = ERP-APD90). After generating baseline data, the hearts were assigned to two groups and perfused with (n = 10) increasing doses of fulvestrant (1 µM and 5 µM; n = 10) or tamoxifen (2.5 µM and 7.5 µM; n = 10), and the protocol was repeated again. RESULTS: Fulvestrant led to a decrease in APD90 and QT interval and an increased PRR. The inducibility of ventricular tachycardia (VT) episodes was unaltered. Tamoxifen showed similar effects, resulting in a shortened APD90 and QT interval and no increased VT incidence in the setting of a prolonged PRR. CONCLUSION: The present study shows no acute proarrhythmic effect of tamoxifen and fulvestrant in an established whole heart model when employing clinically relevant concentrations.


Assuntos
Antiarrítmicos , Arritmias Cardíacas , Coelhos , Feminino , Animais , Antiarrítmicos/farmacologia , Fulvestranto/farmacologia , Fulvestranto/uso terapêutico , Arritmias Cardíacas/induzido quimicamente , Arritmias Cardíacas/tratamento farmacológico , Coração , Potenciais de Ação , Tamoxifeno/farmacologia , Tamoxifeno/uso terapêutico
6.
J Cardiovasc Dev Dis ; 9(8)2022 Aug 17.
Artigo em Inglês | MEDLINE | ID: mdl-36005439

RESUMO

1. Introduction: Pulmonary vein isolation (PVI) is an established procedure used to achieve rhythm control in atrial fibrillation (AF). In obese patients (pts), in whom AF occurs more frequently, a reduced effectiveness of PVI has been observed. Therefore, this study's aim was to compare the long-term efficacy of PVI between obese and non-obese patients. 2. Methods: We enrolled 111 consecutive pts with a body mass index (BMI) of >30 kg/m2 undergoing PVI from our large registry. Procedural data and outcomes were compared with a matched group of 115 non-obese PVI pts and the long-term outcomes were analyzed. 3. Results: Overall follow-up duration was 314 patient-years in the obese and 378 patient-years in the non-obese group. The follow-up rate was 71% in the obese and 76% in the non-obese group. In both groups, their AF-characteristics did not differ significantly, while known risk factors were significantly more prevalent in the obese group. Procedural characteristics were similar in both groups. During follow-up, the obese pts demonstrated significant weight loss compared to the non-obese pts, while at the same time, the overall recurrence rate during follow-up did not differ significantly between both groups (obese: 39.2% and non-obese: 43.7%). PVI related and long-term complications were comparable between both groups. In the univariate analysis, obesity was not found to be associated with an increased AF recurrence risk. 4. Conclusion: These real-life data demonstrate that obese pts may not show higher AF recurrence rates after PVI compared to pts with normal body weight. Furthermore, PVI was found to be safe and effective in obese patients; thus, a BMI alone may not be a criterion for refusal of PVI.

7.
J Pers Med ; 12(8)2022 Jul 28.
Artigo em Inglês | MEDLINE | ID: mdl-36013189

RESUMO

Background: Decision-making in primary prevention is not always trivial and many clinical scenarios are not reflected in current guidelines. To help evaluate a patient's individual risk, a new score to predict the benefit of an implantable defibrillator (ICD) for primary prevention, the MADIT-ICD benefit score, has recently been proposed. The score tries to predict occurrence of ventricular arrhythmias and non-arrhythmic death based on data from four previous MADIT trials. We aimed at examining its usefulness in a large single-center register of S-ICD patients with various underlying cardiomyopathies. Methods and results: All S-ICD patients with a primary preventive indication for ICD implantation from our large single-center database were included in the analysis (n = 173). During a follow-up of 1227 ± 978 days, 27 patients developed sustained ventricular arrhythmias, while 6 patients died for non-arrhythmic reasons. There was a significant correlation for patients with ischemic cardiomyopathy (ICM) (n = 29, p = 0.04) to the occurrence of ventricular arrhythmia. However, the occurrence of ventricular arrhythmias could not sufficiently be predicted by the MADIT-ICD VT/VF score (p = 0.3) in patients with (n = 142, p = 0.19) as well as patients without structural heart disease (n = 31, p = 0.88) and patients with LV-EF < 35%. Of the risk factors included in the risk score calculation, only non-sustained ventricular tachycardias were significantly associated with sustained ventricular arrhythmias (p = 0.02). Of note, non-arrhythmic death could effectively be predicted by the proposed non-arrhythmic mortality score as part of the benefit score (p = 0.001, r = 0.3) also mainly driven by ICM patients. Age, diabetes mellitus, and a BMI < 23 kg/m2 were key predictors of non-arrhythmic death implemented in the score. Conclusion: The MADIT-ICD benefit score adds a new option to evaluate expected benefit of ICD implantation for primary prevention. In a large S-ICD cohort of primary prevention, the value of the score was limited to patients with ischemic cardiomyopathy. Future research should evaluate the performance of the score in different subgroups and compare it to other risk scores to assess its value for daily clinical practice.

8.
Herzschrittmacherther Elektrophysiol ; 33(3): 290-296, 2022 Sep.
Artigo em Alemão | MEDLINE | ID: mdl-35970909

RESUMO

Catheter-based ablation is nowadays a safe and widespread procedure for the treatment of cardiac arrhythmia. This requires exact anatomical knowledge both before and during the examination and is an important prerequisite for targeted treatment. At the beginning of the era of interventional catheter-based treatment, fluoroscopy was the only and usual means of visualization, whereas in the middle of the 1990s continuous 3D-mapping systems were developed for the non-fluoroscopic examination of patients. The correct use of these 3­D systems, which non-fluoroscopically visualize the catheter and mostly identify mechanisms of arrhythmia in great detail, nowadays makes an important contribution to successful interventional catheter treatment of arrhythmia; however, it is not uncommon for patients with ventricular arrhythmia to also carry implanted electronic devices, such as pacemakers, defibrillators or less frequently left ventricular hemodynamic support systems. All implantable devices lead to electromagnetic interferences, which can complicate the diagnostics and treatment during electrophysiological examinations and ablation. This article addresses the adversities and experiences associated with magnet-based 3D systems and implantable electromagnetically active cardiac devices.


Assuntos
Ablação por Cateter , Desfibriladores Implantáveis , Marca-Passo Artificial , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/cirurgia , Fenômenos Eletromagnéticos , Humanos
9.
J Pers Med ; 12(7)2022 Jul 13.
Artigo em Inglês | MEDLINE | ID: mdl-35887632

RESUMO

INTRODUCTION: The long-QT syndrome (LQTS) is the most common ion channelopathy, typically presenting with a prolonged QT interval and clinical symptoms such as syncope or sudden cardiac death. Patients may present with a concealed phenotype making the diagnosis challenging. Correctly diagnosing at-risk patients is pivotal to starting early preventive treatment. OBJECTIVE: Identification of congenital and often concealed LQTS by utilizing novel deep learning network architectures, which are specifically designed for multichannel time series and therefore particularly suitable for ECG data. DESIGN AND RESULTS: A retrospective artificial intelligence (AI)-based analysis was performed using a 12-lead ECG of genetically confirmed LQTS (n = 124), including 41 patients with a concealed LQTS (33%), and validated against a control cohort (n = 161 of patients) without known LQTS or without QT-prolonging drug treatment but any other cardiovascular disease. The performance of a fully convolutional network (FCN) used in prior studies was compared with a different, novel convolutional neural network model (XceptionTime). We found that the XceptionTime model was able to achieve a higher balanced accuracy score (91.8%) than the associated FCN metric (83.6%), indicating improved prediction possibilities of novel AI architectures. The predictive accuracy prevailed independently of age and QTc parameters. CONCLUSIONS: In this study, the XceptionTime model outperformed the FCN model for LQTS patients with even better results than in prior studies. Even when a patient cohort with cardiovascular comorbidities is used. AI-based ECG analysis is a promising step for correct LQTS patient identification, especially if common diagnostic measures might be misleading.

10.
Herzschrittmacherther Elektrophysiol ; 33(2): 161-174, 2022 Jun.
Artigo em Alemão | MEDLINE | ID: mdl-35556156

RESUMO

As with all cardiac interventions, performing left ventricular ablation requires profound knowledge of cardiac anatomy. The aim of this article is to provide an overview of left ventricular anatomy and to characterize complex and clinically relevant structures from an electrophysiologist-centered perspective. In addition to the different access routes, the trabecular network, the left ventricular outflow tract, and the left ventricular conduction system, complex anatomical structures such as the aortomitral continuity and the left ventricular summit are also explained. In addition, this article offers multiple clinical examples that combine ECG, anatomy, and electrophysiologic study.


Assuntos
Ablação por Cateter , Taquicardia Ventricular , Eletrocardiografia , Técnicas Eletrofisiológicas Cardíacas , Endocárdio/cirurgia , Ventrículos do Coração/cirurgia , Humanos , Taquicardia Ventricular/cirurgia
11.
J Cardiovasc Electrophysiol ; 33(6): 1290-1297, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35304782

RESUMO

BACKGROUND: Several case reports have suggested an increased risk of sudden cardiac death due to energy drinks. Therefore, the purpose of this study was to assess acute electrophysiologic effects of caffeine and taurine, two of the main ingredients of energy drinks, in an experimental whole-heart model. METHODS AND RESULTS: Twenty-five rabbit hearts were excised, retrogradely perfused, and assigned to two groups. Hearts were perfused with caffeine (2, 10, and 50 µM) or taurine (2, 10, and 50 µM) after generating baseline data. Eight monophasic action potentials and electrocardiography recordings showed a significant abbreviation of action potential duration (APD90 ), QT interval, and effective refractory periods (ERP) after caffeine treatment. With taurine, cardiac repolarization duration and ERP were significantly shortened. A ventricular vulnerability was assessed by a predefined pacing protocol. With caffeine, we observed a trend towards more ventricular arrhythmias in a dose-dependent manner. After treatment with taurine, significantly more episodes of ventricular arrhythmias occurred. CONCLUSION: In this experimental whole-heart study, treatment with caffeine and taurine provoked ventricular arrhythmias. The underlying mechanism was an abbreviation of cardiac repolarizations and effective refractory periods that may facilitate re-entry and thereby provokes arrhythmias. These findings help to understand the potentially hazardous and fatal outcomes after intoxication with energy drinks.


Assuntos
Doenças Cardiovasculares , Bebidas Energéticas , Potenciais de Ação , Animais , Arritmias Cardíacas/induzido quimicamente , Arritmias Cardíacas/diagnóstico , Cafeína/efeitos adversos , Bebidas Energéticas/efeitos adversos , Fatores de Risco de Doenças Cardíacas , Humanos , Preparação de Coração Isolado , Coelhos , Fatores de Risco , Taurina/farmacologia
12.
J Cardiovasc Dev Dis ; 9(2)2022 Feb 03.
Artigo em Inglês | MEDLINE | ID: mdl-35200703

RESUMO

BACKGROUND: Left atrial tachycardias (LAT) are a well-known outcome of pulmonary vein isolation (PVI). Few data are available on whether the catheter used to perform PVI influences the incidence, as well as the characteristics of post PVI LAT. We present data on LAT following PVI by the following three ablation technologies: (1) phased multi-electrode radiofrequency catheter (PVAC), (2) irrigated single-tip catheter (iRF), and (3) cryoballoon ablation. METHODS: Using a prospectively designed single-center database, we analyzed 650 patients (300 iRF, 150 PVAC, and 200 cryoballoon) with paroxysmal (n = 401) and persistent atrial fibrillation (AF), who underwent their first PVI at our center. RESULTS: The three populations were comparable in their baseline characteristics; however, the cryoballoon group comprised a higher percentage of patients with persistent AF (p = 0.05). The LAT rates were 3.7% in the iRF group (mean follow-up 22 ± 14 months), 0.7% in the PVAC group (mean follow-up 21 ± 14 months), and 4% in the cryoballoon group (mean follow-up 15 ± 8 months). The predominant mechanism of LAT was macro-reentrant tachycardia. Reconnection of at least one pulmonary vein was observed in 87% of the patients who underwent 3D mapping. No predictors for LAT occurrence were identified. CONCLUSION: The occurrence of LAT post PVI is rare; the predominant mechanism was macro-reentrant tachycardia. Reconnection of at least one pulmonary vein was observed in nearly all the LAT patients. In our retrospective analysis, the lowest rate of LAT was observed with the PVAC. No predictors for LAT occurrence were identified.

13.
Eur J Pharmacol ; 917: 174747, 2022 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-35026194

RESUMO

BACKGROUND: Previous studies report conflicting data regarding anti- or proarrhythmic effects of sacubitril. Aim of this study was to assess the impact of acute sacubitril treatment in different arrhythmia models. METHODS: Sacubitril was administered (3, 5, 10 µM) in 12 isolated rabbit hearts. Further 12 hearts were treated with erythromycin to simulate long-QT-syndrome-2 (LQT2). Other 12 hearts were perfused with veratridine to mimic long-QT-syndrome-3 (LQT3). Both LQT-groups were treated with sacubitril (5 µM) additionally. Ventricular vulnerability was assessed by a pacing protocol. AV-blocked bradycardic hearts were perfused with a hypokalemic solution to trigger torsade de pointes (TdP). In further 13 hearts, AF was induced by a combination of acetylcholine and isoproterenol and sacubitril (5 µM) was added afterwards. RESULTS: With sacubitril, action potential duration (APD) was abbreviated whereas spatial dispersion of repolarisation (SDR) remained stable. In both LQT groups, APD and SDR were increased. Infusion of sacubitril reduced APD (- 21 ms, p < 0.01) and SDR (- 8 ms) in the LQT2-group and did not alter APD (+2 ms) but reduced SDR (-19 ms, p < 0.01) in the LQT3-group. Ventricular vulnerability was not altered by sacubitril. No TdP were observed with sacubitril or under baseline conditions in any group. Sacubitril significantly suppressed TdP in the LQT2-group (3 vs. 43 episodes, p < 0.05) but not in the LQT3-group (10 vs. 16 episodes, p = ns). Sacubitril reduced inducibility of AF (9 vs. 31 episodes). CONCLUSION: Sacubitril abbreviated APD. In addition, sacubitril exhibits potential antiarrhythmic effects in LQT2 and may be beneficial in LQT3 and AF.


Assuntos
Aminobutiratos , Compostos de Bifenilo
14.
Basic Clin Pharmacol Toxicol ; 130(1): 103-109, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34634184

RESUMO

BACKGROUND: Previous studies have raised serious concerns on cardiovascular safety of widely prescribed nonsteroidal anti-inflammatory drugs (NSAIDs). Therefore, the aim of this study was to characterize the electrophysiological effects of certain NSAIDs in an established whole heart model of proarrhythmia. METHODS AND RESULTS: Thirty-eight hearts of New Zealand White rabbits were harvested and retrogradely perfused employing a Langendorff setup, and electrophysiology studies were performed to investigate action potential duration at 90% of repolarization (APD90 ), QT intervals, and effective refractory period (ERP). After generating baseline data, hearts were perfused with ibuprofen (Group 1, n = 12; 10 and 30 µM), indomethacin (Group 2, n = 13; 10 and 20 µM) and diclofenac (Group 3, n = 13; 10 and 20 µM), respectively, and the pacing protocols were repeated for each concentration. In all groups, perfusion with the NSAIDs resulted in a significant and reproducible shortening of APD90 and QT interval. In all groups, the arrhythmia susceptibility was significantly raised as occurrence of monomorphic ventricular tachycardia under programmed ventricular stimulation was significantly increased under perfusion with ibuprofen, indomethacin and diclofenac in all concentrations. CONCLUSION: The perfusion with ibuprofen, indomethacin and diclofenac in commonly used doses raised the arrhythmia susceptibility in an established rabbit whole-heart model while APD shortening and shortened ERP seem to be crucial for arrhythmogenesis.


Assuntos
Anti-Inflamatórios não Esteroides/toxicidade , Arritmias Cardíacas/induzido quimicamente , Taquicardia Ventricular/induzido quimicamente , Potenciais de Ação/efeitos dos fármacos , Animais , Anti-Inflamatórios não Esteroides/administração & dosagem , Eletrofisiologia Cardíaca , Diclofenaco/administração & dosagem , Diclofenaco/toxicidade , Relação Dose-Resposta a Droga , Eletrocardiografia , Feminino , Ibuprofeno/administração & dosagem , Ibuprofeno/toxicidade , Indometacina/administração & dosagem , Indometacina/toxicidade , Preparação de Coração Isolado , Coelhos
15.
Sci Rep ; 11(1): 23940, 2021 12 14.
Artigo em Inglês | MEDLINE | ID: mdl-34907251

RESUMO

Previous studies suggest an impact of dexmedetomidine on cardiac electrophysiology. However, experimental data is sparse. Therefore, purpose of this study was to investigate the influence of dexmedetomidine on different experimental models of proarrhythmia. 50 rabbit hearts were explanted and retrogradely perfused. The first group (n = 12) was treated with dexmedetomidine in ascending concentrations (3, 5 and 10 µM). Dexmedetomidine did not substantially alter action potential duration (APD) but reduced spatial dispersion of repolarization (SDR) and rendered the action potentials rectangular, resulting in no proarrhythmia. In further 12 hearts, erythromycin (300 µM) was administered to simulate long-QT-syndrome-2 (LQT2). Additional treatment with dexmedetomidine reduced SDR, thereby suppressing torsade de pointes. In the third group (n = 14), 0.5 µM veratridine was added to reduce the repolarization reserve. Further administration of dexmedetomidine did not influence APD, SDR or the occurrence of arrhythmias. In the last group (n = 12), a combination of acetylcholine (1 µM) and isoproterenol (1 µM) was used to facilitate atrial fibrillation. Additional treatment with dexmedetomidine prolonged the atrial APD but did not reduce AF episodes. In this study, dexmedetomidine did not significantly alter cardiac repolarization duration and was not proarrhythmic in different models of ventricular and atrial arrhythmias. Of note, dexmedetomidine might be antiarrhythmic in acquired LQT2 by reducing SDR.


Assuntos
Arritmias Cardíacas/fisiopatologia , Dexmedetomidina/farmacologia , Técnicas Eletrofisiológicas Cardíacas , Sistema de Condução Cardíaco/fisiopatologia , Animais , Modelos Animais de Doenças , Preparação de Coração Isolado , Coelhos
16.
J Pers Med ; 11(11)2021 Nov 11.
Artigo em Inglês | MEDLINE | ID: mdl-34834528

RESUMO

BACKGROUND: Different electrocardiogram (ECG) findings are known to be independent predictors of clinical response to cardiac resynchronization therapy (CRT). It remains unknown how these findings influence very long-term prognosis. METHODS AND RESULTS: A total of 102 consecutive patients (75 males, mean age 65 ± 10 years) referred to our center for CRT implantation had previously been included in this prospective observational study. The same patient group was now re-evaluated for death from all causes over a prolonged median follow-up of 10.3 years (interquartile range 9.4-12.5 years). During follow-up, 55 patients died, and 82% of the clinical non-responders (n = 23) and 44% of the responders (n = 79) were deceased. We screened for univariate associations and found QRS width during biventricular (BIV) pacing (p = 0.02), left ventricular (LV) pacing (p < 0.01), Δ LV paced-right ventricular (RV) paced (p = 0.03), age (p = 0.03), New York Heart Association (NYHA) class (p < 0.01), CHA2DS2-Vasc score (p < 0.01), glomerular filtration rate (p < 0.01), coronary artery disease (p < 0.01), non-ischemic cardiomyopathy (NICM) (p = 0.01), arterial hypertension (p < 0.01), NT-proBNP (p < 0.01), and clinical response to CRT (p < 0.01) to be significantly associated with mortality. In the multivariate analysis, NICM, the lower NYHA class, and smaller QRS width during BIV pacing were independent predictors of better outcomes. CONCLUSION: Our data show that QRS width duration during biventricular pacing, an ECG parameter easily obtainable during LV lead placement, is an independent predictor of mortality in a long-term follow-up. Our data add further evidence that NICM and lower NYHA class are independent predictors for better outcome after CRT implantation.

17.
J Pers Med ; 11(10)2021 Sep 30.
Artigo em Inglês | MEDLINE | ID: mdl-34683135

RESUMO

BACKGROUND: Pulmonary vein isolation (PVI) and antiarrhythmic drug therapy are established treatment strategies to preserve sinus rhythm in atrial fibrillation (AF). However, the efficacy of both interventional and pharmaceutical therapy is still limited. Solid evidence suggests an important role of the cardiac sympathetic nervous system in AF. In this blinded, prospective observational study, we studied left ventricular cardiac sympathetic activity in patients treated with PVI and with antiarrhythmic drugs. Prospectively, Iodine-123-benzyl-guanidine single photon emission computer tomography (123I-mIBG-SPECT) was performed in a total of 23 patients with paroxysmal AF, who underwent PVI (n = 20) or received antiarrhythmic drug therapy only (n = 3), respectively. 123I-mIBG planar and SPECT/CT scans were performed before and 4 to 8 weeks after PVI (or initiation of drug therapy, respectively). For semiquantitative SPECT image analysis, attenuation-corrected early/late images were analyzed. Quantitative SPECT analysis was performed using the AHA 17-segment model of the left ventricle. RESULTS: PVI with point-by-point radiofrequency ablation led to a significantly (p < 0.05) higher visual sympathetic innervation defect score when comparing pre-and post PVI. Newly emerging innervation deficits post PVI were localized predominantly in the inferior lateral wall. These findings were corroborated by semiquantitative SPECT analysis identifying inferolateral segments with a reduced tracer uptake in comparison to SPECT before PVI. Following PVI, patients with an AF relapse showed a different sympathetic innervation pattern compared to patients with sufficient rhythm control. CONCLUSIONS: PVI results in novel defects of cardiac sympathetic innervation. Differences in cardiac sympathetic innervation remodelling following PVI suggest an important role of the cardiac autonomous nervous system in the maintenance of sinus rhythm following PVI.

18.
J Pers Med ; 11(9)2021 Sep 13.
Artigo em Inglês | MEDLINE | ID: mdl-34575689

RESUMO

INTRODUCTION: Multiple studies have shown that left atrial (LA) enlargement is a strong predictor of poor outcome after catheter ablation of atrial fibrillation (AF). LA size is commonly approximated as the diameter in the parasternal long axis. It remains unknown whether more precise echocardiographic measurements of LA size allow for better correlation with outcome after pulmonary vein isolation (PVI). METHODS AND RESULTS: We performed a retrospective study of 131 consecutive patients (43 females, 60% paroxysmal AF, mean CHA2DS2-Vasc score 1.6, mean age 61 ± 12 years) referred for PVI. Measurements of the LA were carried out by a single observer in transthoracic echocardiograms (TTE) performed prior to ablation. We calculated diameter of the LA in the parasternal long axis (PLAX), LA area in the 2- as well as 4-Chamber (CH) view. LA volume was computed using the disc summation technique (LAV) and indexed to body surface area (LAVI). Procedural and follow-up data were gathered from a prospective AF database. Ablation was performed exclusively using the second generation cryoballoon by the same operators. Follow-up visits at 3, 6 and 12 months showed freedom from AF in 76%, 73% and 73% respectively. Mean values of LA calculations were LAPLAX: 37.9 mm ± 6.3 mm, 2CH area: 22.5 cm2 ± 6.7 cm2, 4CH area: 21.4 cm2 ± 5.5 cm2, LAV: 73.7 mL ± 26.1 mL and LAVI: 36.2 mL/m2 ± 12.7 mL/m2, respectively. C statistic revealed the best concordance of LAVI with outcome after 12 months (C = 0.67), LAV also exhibited a satisfactory value (C = 0.61) in comparison to surfaces in 2CH (C = 0.59) and 4CH (C = 0.57). PLAX showed the worst correlation (C = 0.51). Additionally, different binary logistic regression models identified three independent predictors of AF outcome after cryoballoon PVI: gender (OR = 0.95 per year; p = 0.01); LAV (OR = 1.3/10mL; p = 0.02) and LAVI (OR = 1.58/10 mL/m2; p = 0.02). In all models, PLAX and area measurements were not predictive. CONCLUSIONS: Our data add further to evidence that LA size lends itself well as a predictor of PVI outcome. LAVI and LAV were independently predictive of rhythm outcome after PVI. This did not hold true for more commonly used measurements, such as PLAX diameter and surfaces of the LA, irrespective of the view chosen.

19.
Clin Res Cardiol ; 110(6): 905-912, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33961097

RESUMO

INTRODUCTION: Supraventricular tachycardias (SVT) are often difficult to document due to their intermittent, short-lasting nature. Smartphone-based one-lead ECG monitors (sECG) were initially developed for the diagnosis of atrial fibrillation. No data have been published regarding their potential role in differentiating inappropiate sinus tachycardia (IST) from regular SVT. If cardiologists could distinguish IST from SVT in sECG, economic health care burden might be significantly reduced. METHODS: We prospectively recruited 75 consecutive patients with known SVT undergoing an EP study. In all patients, four ECG were recorded: a sECG during SVT and during sinus tachycardia and respective 12-lead ECG. Two experienced electrophysiologists were blinded to the diagnoses and separately evaluated all ECG. RESULTS: Three hundred individual ECG were recorded in 75 patients (47 female, age 50 ± 18 years, BMI 26 ± 5 kg/m2, 60 AVNRT, 15 AVRT). The electrophysiologists' blinded interpretation of sECG recordings showed a sensitivity of 89% and a specificity of 91% for the detection of SVT (interobserver agreement κ = 0.76). In high-quality sECG recordings (68%), sensitivity rose to 95% with a specificity of 92% (interobserver agreement of κ = 0.91). Specificity increased to 96% when both electrophysiologists agreed on the diagnosis. Respective 12-lead ECG had a sensitivity of 100% and specificity of 98% for the detection of SVT. CONCLUSION: A smartphone-based one-lead ECG monitor allows for differentiation of SVT from IST in about 90% of cases. These results should encourage cardiologists to integrate wearables into clinical practice, possibly reducing time to definitive diagnosis of an arrhythmia and unnecessary EP procedures. A smartphone-based one lead ECG device (panel A) can be used reliably to differentiate supraventricular tachycardia (panel B) from inappropriate sinus tachycardia when compared to a simultaneously conducted gold-standard electrophysiology study (panels C, D).


Assuntos
Eletrocardiografia/métodos , Smartphone , Taquicardia Supraventricular/diagnóstico , Diagnóstico Diferencial , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Taquicardia Sinusal/diagnóstico , Taquicardia Sinusal/fisiopatologia , Taquicardia Supraventricular/fisiopatologia
20.
Int Heart J ; 62(1): 72-77, 2021 Jan 30.
Artigo em Inglês | MEDLINE | ID: mdl-33455989

RESUMO

Atrioventricular nodal reentry tachycardia (AVNRT) is the most common regular supraventricular tachycardia (SVT). Slow pathway modification (SPM) is the accepted first line treatment with reported success rates around 95%. Information regarding possible predictors of AVNRT recurrence is scarce.Out of 4170 consecutive patients with SPM in our department from 1993-2018, we identified 78 patients (1.9%) receiving > 1 SPM (69% female, median age 50 years) with a recurrence of AVNRT after a successful SPM. We matched these patients for age, gender and number of radiofrequency applications during first SPM with 78 patients who received one successful SPM in our center without AVNRT recurrence. Both groups were analyzed for possible predictors of a recurrence of AVNRT during long-term follow-up. The recurrence group contained a significantly lower proportion of patients with an occurrence of junctional beats during SPM (69% versus 89%, P = 0.006). Moreover, significantly more cases of previously diagnosed atrial fibrillation/tachycardia (AF/AT; 21% versus 5%, P = 0.007) and inducible AF/AT during electrophysiology study (23% versus 6%, P = 0.006) were present in the recurrence group. While more than half of patients had a recurrence within the first year, in 20% symptoms reappeared ≥ 4 years after ablation.In a small percentage of patients, AVNRT recurs after an initially successful ablation. Interestingly, these patients had significantly fewer junctional beats during ablation and a higher rate of other (inducible) arrhythmias. AVNRT recurrence spanned a considerable timeframe and should remain a differential diagnosis, even years after ablation.


Assuntos
Nó Atrioventricular/fisiopatologia , Fascículo Atrioventricular/cirurgia , Ablação por Cateter/métodos , Taquicardia por Reentrada no Nó Atrioventricular/fisiopatologia , Adulto , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/cirurgia , Nó Atrioventricular/cirurgia , Fascículo Atrioventricular/fisiopatologia , Eletrofisiologia Cardíaca/métodos , Eletrofisiologia Cardíaca/estatística & dados numéricos , Estudos de Casos e Controles , Diagnóstico Diferencial , Eletrocardiografia/métodos , Feminino , Seguimentos , Sistema de Condução Cardíaco/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Recidiva , Estudos Retrospectivos , Taquicardia por Reentrada no Nó Atrioventricular/diagnóstico , Taquicardia por Reentrada no Nó Atrioventricular/cirurgia , Taquicardia Supraventricular/classificação , Taquicardia Supraventricular/fisiopatologia , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA