Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Heliyon ; 9(11): e22247, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-38045136

RESUMO

Complex multilayer film structures were fabricated through a custom-built angular DC magnetron co-sputtering system. In this system, separate Cu, Al, and brass (Cu + Zn) targets were mounted on three magnetron guns, working in conjunction with a rotating substrate. This study aimed to compare the properties of films with intricate structures, which were sputtered onto glass slides and polypropylene substrates. The sputtering process was optimized using a Box-Behnken design, considering three variable operating conditions: substrate rotation speed, sputtering time, and sputtering voltage. The Analysis of Variance (ANOVA) results for film thickness and roughness, sputtered with three different materials onto glass slides and polypropylene (PP) substrates, indicated that all three independent variables significantly influenced the optimum response, with P-values less than 0.05 (<α = 0.05). The optimal conditions for maximizing the thickness and roughness of the sputtered film on PP substrates differed from those obtained for the thin-film properties of the sputtered film on glass slide substrates. Top-view images of the surface morphology revealed a dense and granular structure for the film deposited on the glass slide, whereas some grooves between the grains and fractures were observed in the film on the PP substrate. Additionally, it was evident that these sputtered multilayer films exhibited a complex structure, as reflected in the uniform and homogeneous distribution of Cu, Al, and Zn atoms on both glass slides and PP substrates.

2.
Foods ; 12(24)2023 Dec 06.
Artigo em Inglês | MEDLINE | ID: mdl-38137190

RESUMO

Water, soil, and food products contain pesticide residues. These residues result from excessive pesticides use, motivated by the fact that agricultural productivity can be increased by the use of these pesticides. The accumulation of these residues in the body can cause health problems, leading to food safety concerns. Cold plasma technology has been successfully employed in various applications, such as seed germination, bacterial inactivation, wound disinfection, surface sterilization, and pesticide degradation. In recent years, researchers have increasingly explored the effectiveness of cold plasma technology in the degradation of pesticide residues. Most studies have shown promising outcomes, encouraging further research and scaling-up for commercialization. This review summarizes the use of cold plasma as an emerging technology for pesticide degradation in terms of the plasma system and configuration. It also outlines the key findings in this area. The most frequently adopted plasma systems for each application are identified, and the mechanisms underlying pesticide degradation using cold plasma technology are discussed. The possible factors influencing pesticide degradation efficiency, challenges in research, and future trends are also discussed. This review demonstrates that despite the nascent nature of the technology, the use of cold plasma shows considerable potential in regards to pesticide residue degradation, particularly in food applications.

3.
RSC Adv ; 13(21): 14078-14088, 2023 May 09.
Artigo em Inglês | MEDLINE | ID: mdl-37197673

RESUMO

The study aimed to investigate the effects of two different plasma systems, including pinhole plasma jet and gliding arc (GA) plasma, for the degradation of herbicide, diuron, in plasma activated solutions (PAS). In the GA plasma system, air was used to generate plasma, however, Ar, oxygen and nitrogen at different gas compositions were compared in the pinhole plasma jet system. The Taguchi design model was used to study the effects of gas compositions. Results revealed that the pinhole plasma jet system was able to degrade over 50% of the diuron in 60 minutes. The optimal plasma generation condition for the highest degradation of diuron used pure Ar gas. The highest degradation percentage of herbicide in PAS corresponded to the lowest hydrogen peroxide (H2O2) content, nitrite concentration and electrical conductivity (EC) of the PAS. The diuron degradation products were identified as 3,4-dichloro-benzenamine, 1-chloro-3-isocyanato-benzene and 1-chloro-4-isocyanato-benzene via gas chromatography-mass spectrometry (GC-MS). The GA plasma system was not adequate for the degradation of herbicide in PAS.

4.
Sci Rep ; 13(1): 6041, 2023 04 13.
Artigo em Inglês | MEDLINE | ID: mdl-37055481

RESUMO

Mastitis is a disease that directly affects the quantity and quality of milk produced by dairy cows, which can have a negative impact on the income generated from selling the milk. Severe inflammation caused by this mammary disease can result in up to 1 × 106 white blood cells per milliliter of cow milk. Currently, the California mastitis test is a popular chemical inspection test, but its error rate of over 40% is a significant factor in the ongoing spread of mastitis. In this study, a new microfluidic device was designed and fabricated to identify normal, sub-clinical, and clinical mastitis. This portable device allows for precise and analysis of results within a second. The device was designed to screen somatic cells and a staining process was added to identify somatic cells using single-cell process analysis. The fluorescence principle was used to identify the infection status of the milk, which was analyzed using a mini-spectrometer. The accuracy of the device was tested, and it was found to determine the infection status with 95% accuracy, compared to the accuracy obtained using the Fossomatic machine. By introducing this new microfluidic device, it is believed that the spread of mastitis in dairy cows can be significantly reduced, leading to higher quality and more profitable milk production.


Assuntos
Mastite Bovina , Leite , Animais , Bovinos , Feminino , Humanos , Microfluídica , Mastite Bovina/diagnóstico , Glândulas Mamárias Animais , Contagem de Células , Lactação
5.
Materials (Basel) ; 15(23)2022 Dec 02.
Artigo em Inglês | MEDLINE | ID: mdl-36500111

RESUMO

This research was aimed at developing a dental prototype from 3D printing technology using a synthetic filament of polylactic acid (PLA) and zirconium dioxide (ZrO2) with glycerol and silane coupling agent as a binder. A face-centered central composite design was used to study the effects of the filament extrusion parameters and the 3D printing parameters. Tensile and compressive testing was conducted to determine the stress-strain relationship of the filaments. The yield strength, elongation percentage and Young's modulus were also calculated. Results showed the melting temperature of 193 °C, ZrO2 ratio of 17 wt.% and 25 rpm screw speed contributed to the highest ultimate tensile strength of the synthetic filament. A Nozzle temperature of 210 °C and an infill density of 100% had the most effect on the ultimate compressive strength whilst the printing speed had no significant effects. Differential scanning calorimetry (DSC) was used to study the thermal properties and percentage of crystallinity of PLA filaments. The addition of glycerol and a silane coupling agent increased the tensile strength and filament size. The ZrO2 particles induced the crystallization of the PLA matrix. A higher crystallization was also obtained from the annealing treatment resulting in the greater thermal resistance performance of the dental crown prototype.

6.
Materials (Basel) ; 15(23)2022 Dec 03.
Artigo em Inglês | MEDLINE | ID: mdl-36500124

RESUMO

A severe plastic deformation process for the achievement of favorable mechanical properties for metallic powder is mechanical milling. However, to obtain the highest productivity while maintaining reasonable manufacturing costs, the process parameters must be optimized to achieve the best mechanical properties. This study involved the use of response surface methodology to optimize the mechanical milling process parameters of harmonic-structure pure Cu. Certain critical parameters that affect the properties and fracture mechanisms of harmonic-structure pure Cu were investigated and are discussed in detail. The Box-Behnken design was used to design the experiments to determine the correlation between the process parameters and mechanical properties. The results show that the parameters (rotation speed, mechanical milling time, and powder-to-ball ratio) affect the microstructure characteristics and influence the mechanical performance, including the fracture mechanisms of harmonic-structure pure Cu specimens. The best combination values of the ultimate tensile strength (UTS) and elongation were found to be 272 MPa and 46.85%, respectively. This combination of properties can be achieved by applying an optimum set of process parameters: a rotation speed of 200 rpm; mechanical milling time of 17.78 h; and powder-to-ball ratio of 0.065. The superior UTS and elongation of the harmonic-structure pure Cu were found to be related to the delay of void and crack initiation in the core and shell interface regions, which in turn were controlled by the degree of strength variation between these regions.

7.
Foods ; 11(18)2022 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-36140988

RESUMO

Plasma activated water (PAW) generated from pinhole plasma jet using gas mixtures of argon (Ar) and 2% oxygen (O2) was evaluated for pesticide degradation and microorganism decontamination (i.e., Escherichia coli and Colletotrichum gloeosporioides) in chili (Capsicum annuum L.). A flow rate of 10 L/min produced the highest concentration of hydrogen peroxide (H2O2) at 369 mg/L. Results showed that PAW treatment for 30 min and 60 min effectively degrades carbendazim and chlorpyrifos by about 57% and 54% in solution, respectively. In chili, carbendazim and chlorpyrifos were also decreased, to a major extent, by 80% and 65% after PAW treatment for 30 min and 60 min, respectively. E. coli populations were reduced by 1.18 Log CFU/mL and 2.8 Log CFU/g with PAW treatment for 60 min in suspension and chili, respectively. Moreover, 100% of inhibition of fungal spore germination was achieved with PAW treatment. Additionally, PAW treatment demonstrated significantly higher efficiency (p < 0.05) in controlling Anthracnose in chili by about 83% compared to other treatments.

8.
Micromachines (Basel) ; 13(3)2022 Mar 10.
Artigo em Inglês | MEDLINE | ID: mdl-35334718

RESUMO

This study proposes a microfluidic device used for X-/Y-sperm separation based on monoclonal antibody-conjugated magnetic beads, which become positively charged in the flow system. Y-sperms were selectively captured via a monoclonal antibody and transferred onto the microfluidic device and were discarded, so that X-sperms can be isolated and commercially exploited for fertilization demands of female cattle in dairy industry. Therefore, the research team used monoclonal antibody-conjugated magnetic beads to increase the force that causes the Y-sperm to be pulled out of the system, leaving only the X-sperm for further use. The experimental design was divided into the following: Model 1, the microfluid system for sorting positive magnetic beads, which yielded 100% separation; Model 2, the sorting of monoclonal antibody-conjugated magnetic beads in the fluid system, yielding 98.84% microcirculation; Model 3, the sorting of monoclonal antibody-conjugated magnetic beads with sperm in the microfluid system, yielding 80.12% microcirculation. Moreover, the fabrication microfluidic system had thin film electrodes created via UV lithography and MWCNTs electrode structure capable of erecting an electrode wall 1500 µm above the floor with a flow channel width of only 100 µm. The system was tested using a constant flow rate of 2 µL/min and X-/Y-sperm were separated using carbon nanotube electrodes at 2.5 V. The structure created with the use of vertical electrodes and monoclonal antibody-conjugated magnetic beads technique produced a higher effective rejection effect and was able to remove a large number of unwanted sperm from the system with 80.12% efficiency.

9.
Sci Rep ; 10(1): 17143, 2020 10 13.
Artigo em Inglês | MEDLINE | ID: mdl-33051512

RESUMO

Microfluidics is proposed as a technique for efficient sperm sorting, to achieve the ultimate goal of resolving infertility problems in livestock industry. Our study aimed to design a microfluidic sperm-sorting device (SSD) through a high-efficacy and cost- and time-effective fabrication process, by using COMSOL Multiphysics simulation and modeling software, and the design of experiment (DOE) method. The eight factors affecting SSD performance were established. The simulation was then run, and statistically significant factors were analyzed. Minitab16 was used to optimize the design modulus factor. By setting the statistical significance at p < 0.05, the factors affecting experimental structure were analyzed. At a desirability of 97.99, the optimal parameters for the microfluidic chip were: angle between sperm and medium inlet chambers (A = 43°), sperm inlet flow rate (B = 0.24 µL min-1), medium inlet flow rate (C = 0.34 µL min-1), and inlet and outlet chamber lengths (D = 5000 µm). These optima were then applied to microfluidics device construction. The device was produced using soft lithographic microfabrication techniques and tested on Holstein-Friesian bull sperm. The highest bull sperm-sorting performance for this microfluidic device prototype was 96%. The error between the simulation and the actual microfluidic device was 2.72%. Fluid viscosity ranges analysis-based simulations revealed acceptable fluid viscosity tolerances for the SSD. The simulation results revealed that the acceptable tolerance range for fluid viscosity was 0.00001-0.003 kg m-1 s-1. This optimally designed microfluidic chip-based SSD may be integrated into sperm x/y separation micro devices.


Assuntos
Separação Celular/instrumentação , Desenho de Equipamento/instrumentação , Microfluídica/instrumentação , Animais , Bovinos , Infertilidade/terapia , Dispositivos Lab-On-A-Chip , Gado/fisiologia , Masculino , Técnicas Analíticas Microfluídicas/instrumentação , Motilidade dos Espermatozoides/fisiologia , Espermatozoides/citologia
10.
Micromachines (Basel) ; 10(10)2019 Sep 26.
Artigo em Inglês | MEDLINE | ID: mdl-31561484

RESUMO

In this research, we aimed to count the ratio of the number of motile to immotile sperm for patients with infertility problems based on a low-sperm-concentration examination. The microfluidic system consists of two series of applications: The conventional separation of motile sperm and the proposed inductance (L), capacitance (C), and resistance (R) or LCR impedance sperm counter. In the experiment, 96% of motile sperm were isolated from nonmotile sperm in the first part and transported to the second part to count and calculate real-time sperm concentration. A pair of microelectrodes composed of thin metal film were integrated between microchannels, resulting in a peak signal for LCR single-cell detection, as well as the estimated total sperm concentration. A minimum of 10 µL of the sperm sample was completely analyzed with an accuracy of 94.8% compared with the standard computer-assisted semen analysis (CASA) method. This method could be applied for low-cost sperm separation and counting in the future.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA