Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
Talanta ; 275: 126077, 2024 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-38636440

RESUMO

We present an innovative, reliable, and antibody-free analytical method to determine multiple intact natriuretic peptides in human plasma. These biomolecules are routinely used to confirm the diagnosis and monitor the evolution of heart failure, so that their determination is essential to improve diagnosis and monitor the efficacy of treatment. However, common immunoassay kits suffer from main limitations due to high cross-reactivity with structurally similar species. In our method, we pre-treated the sample by combining salting-out with ammonium sulfate with microextraction by packed sorbent technique. Analyses were then carried out by ultra-high performance liquid chromatography-electrospray ionization-tandem mass spectrometry. The use of 3-nitrobenzyl alcohol as a supercharger reagent enhanced the ESI ionization and improved the signal-to-noise ratio. The analytical protocol showed good linearity over one order of magnitude, recovery in the range of 94-105 %, and good intra- and inter-day reproducibility (RSD<20 %), and the presence of a matrix effect. Limits of detection were in the range of pg/mL for all peptides (0.2-20 pg/mL). Stability study in plasma samples demonstrated that proper protease inhibitors need to be included in blood collection tubes to avoid peptide degradation. Preliminary analyses on plasma samples from heart failure patients allow the quantification of ANP 1-28 as the most abundant species and the detection of ANP 5-28, BNP 1-32, and BNP 5-32. The method could be used to investigate how cross-reactivity issues among structurally similar species impact determinations by ELISA kits.

2.
Prostaglandins Other Lipid Mediat ; 169: 106770, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37633481

RESUMO

Oxylipins are important signalling compounds that are significantly involved in the regulation of the immune system and the resolution of inflammation. Lipid metabolism is strongly activated upon SARS-CoV-2 infection, however the modulating effects of oxylipins induced by different variants remain unexplored. Here, we compare the plasma profiles of thirty-seven oxylipins and four PUFAs in subjects infected with Wild-type, Alpha (B.1.1.7), Delta (B.1.617.2), and Omicron (B.1.1.529) variants. The results suggest that oxidative stress and inflammation resulting from COVID-19 were highly dependent on the SARS-CoV-2 variant, and that the Wild-type elicited the strongest inflammatory storm. The Alpha and Delta variants induced a comparable lipid profile alteration upon infection, which differed significantly from Omicron. The latter variant increased the levels of pro-inflammatory mediators and decreased the levels of omega-3 PUFA in infected patients. We speculate that changes in therapeutics, vaccination, and prior infections may have a role in the alteration of the oxylipin profile besides viral mutations. The results shed new light on the evolution of the inflammatory response in COVID-19.


Assuntos
COVID-19 , SARS-CoV-2 , Humanos , Oxilipinas , Ácidos Graxos Insaturados , Inflamação
3.
J Breath Res ; 17(4)2023 08 09.
Artigo em Inglês | MEDLINE | ID: mdl-37524075

RESUMO

This paper describes the AEOLUS pilot study which combines breath analysis with cardiopulmonary exercise testing (CPET) and an echocardiographic examination for monitoring heart failure (HF) patients. Ten consecutive patients with a prior clinical diagnosis of HF with reduced left ventricular ejection fraction were prospectively enrolled together with 15 control patients with cardiovascular risk factors, including hypertension, type II diabetes or chronic ischemic heart disease. Breath samples were collected at rest and during CPET coupled with exercise stress echocardiography (CPET-ESE) protocol by means of needle trap micro-extraction and were analyzed through gas-chromatography coupled with mass spectrometry. The protocol also involved using of a selected ion flow tube mass spectrometer for a breath-by-breath isoprene and acetone analysis during exercise. At rest, HF patients showed increased breath levels of acetone and pentane, which are related to altered oxidation of fatty acids and oxidative stress, respectively. A significant positive correlation was observed between acetone and the gold standard biomarker NT-proBNP in plasma (r= 0.646,p< 0.001), both measured at rest. During exercise, some exhaled volatiles (e.g., isoprene) mirrored ventilatory and/or hemodynamic adaptation, whereas others (e.g., sulfide compounds and 3-hydroxy-2-butanone) depended on their origin. At peak effort, acetone levels in HF patients differed significantly from those of the control group, suggesting an altered myocardial and systemic metabolic adaptation to exercise for HF patients. These preliminary data suggest that concomitant acquisition of CPET-ESE and breath analysis is feasible and might provide additional clinical information on the metabolic maladaptation of HF patients to exercise. Such information may refine the identification of patients at higher risk of disease worsening.


Assuntos
Diabetes Mellitus Tipo 2 , Insuficiência Cardíaca , Humanos , Teste de Esforço/métodos , Volume Sistólico , Acetona , Projetos Piloto , Função Ventricular Esquerda , Testes Respiratórios/métodos , Insuficiência Cardíaca/diagnóstico por imagem , Ecocardiografia/métodos
4.
Artigo em Inglês | MEDLINE | ID: mdl-37481789

RESUMO

Variations in salivary short-chain fatty acids and hydroxy acids (e.g., lactic acid, and 3-hydroxybutyric acid) levels have been suggested to reflect the dysbiosis of human gut microbiota, which represents an additional factor involved in the onset of heart failure (HF) disease. The physical-chemical properties of these metabolites combined with the complex composition of biological matrices mean that sample pre-treatment procedures are almost unavoidable. This work describes a reliable, simple, and organic solvent free protocol for determining short-chain fatty acids and hydroxy acids in stimulated saliva samples collected from heart failure, obese, and hypertensive patients. The procedure is based on in-situ pentafluorobenzyl bromide (PFB-Br) derivatization and HiSorb sorptive extraction coupled to thermal desorption and gas chromatography-tandem mass spectrometry. The HiSorb extraction device is completely compatible with aqueous matrices, thus saving on time and materials associated with organic solvent-extraction methods. A Central Composite Face-Centred experimental design was used for the optimization of the molar ratio between PFB-Br and target analytes, the derivatization temperature, and the reaction time which were 100, 60 °C, and 180 min, respectively. Detection limits in the range 0.1-100 µM were reached using a small amount of saliva (20 µL). The use of sodium acetate-1-13C as an internal standard improved the intra- and inter-day precision of the method which ranged from 10 to 23%. The optimized protocol was successfully applied for what we believe is the first time to evaluate the salivary levels of short chain fatty acids and hydroxy acids in saliva samples of four groups of patients: i) patients admitted to hospital with acute HF symptoms, ii) patients with chronic HF symptoms, iii) patients without HF symptoms but with obesity, and iv) patients without HF symptoms but with hypertension. The first group of patients showed significantly higher levels of salivary acetic acid and lactic acid at hospital admission as well as the lowest values of hexanoic acid and heptanoic acid. Moreover, the significant high levels of acetic acid, propionic acid, and butyric acid observed in HF respect to the other patients suggest the potential link between oral bacteria and gut dysbiosis.


Assuntos
Insuficiência Cardíaca , Hidroxiácidos , Humanos , Hidroxiácidos/análise , Disbiose , Cromatografia Gasosa-Espectrometria de Massas/métodos , Ácidos Graxos Voláteis/análise , Ácido Acético , Ácido Butírico , Ácido Láctico/análise , Ácidos Graxos
5.
Free Radic Biol Med ; 201: 55-65, 2023 05 20.
Artigo em Inglês | MEDLINE | ID: mdl-36940734

RESUMO

Cardiovascular diseases (CVDs) are the leading cause of premature death and disability in humans and their incidence continues to increase. Oxidative stress and inflammation have been recognized as key pathophysiological factors in cardiovascular events. The targeted modulation of the endogenous mechanisms of inflammation, rather than its simple suppression, will become key in treating chronic inflammatory diseases. A comprehensive characterization of the signalling molecules involved in inflammation, such as endogenous lipid mediators, is thus needed. Here, we propose a powerful MS-based platform for the simultaneous quantitation of sixty salivary lipid mediators in CVD samples. Saliva, which represents a non-invasive and painless alternative to blood, was collected from patients suffering from acute and chronic heart failure (AHF and CHF, respectively), obesity and hypertension. Of all the patients, those with AHF and hypertension showed higher levels of isoprostanoids, which are key indexes of oxidant insult. Compared to the obese population, AHF patients showed lower levels (p < 0.02) of antioxidant omega-3 fatty acids, in line with the "malnutrition-inflammation complex syndrome" typical of HF patients. At hospital admission, AHF patients showed significantly higher levels (p < 0.001) of omega-3 DPA and lower levels (p < 0.04) of lipoxin B4 than CHF patients, suggesting a lipid rearrangement typical of the failing heart during acute decompensation. If confirmed, our results highlight the potential use of lipid mediators as predictive markers of re-acutisation episodes, thus providing opportunities for preventive intervention and a reduction in hospitalizations.


Assuntos
Doenças Cardiovasculares , Ácidos Graxos Ômega-3 , Insuficiência Cardíaca , Hipertensão , Humanos , Inflamação , Doença Crônica , Obesidade , Mediadores da Inflamação
6.
Biosensors (Basel) ; 12(10)2022 Oct 18.
Artigo em Inglês | MEDLINE | ID: mdl-36291031

RESUMO

Sepsis is defined as a systemic inflammatory dysfunction strictly associated with infectious diseases, which represents an important health issue whose incidence is continuously increasing worldwide. Nowadays, sepsis is considered as one of the main causes of death that mainly affects critically ill patients in clinical settings, with a higher prevalence in low-income countries. Currently, sepsis management still represents an important challenge, since the use of traditional techniques for the diagnosis does not provide a rapid response, which is crucial for an effective infection management. Biosensing systems represent a valid alternative due to their characteristics such as low cost, portability, low response time, ease of use and suitability for point of care/need applications. This review provides an overview of the infectious agents associated with the development of sepsis and the host biomarkers suitable for diagnosis and prognosis. Special focus is given to the new emerging biosensing technologies using electrochemical and optical transduction techniques for sepsis diagnosis and management.


Assuntos
Técnicas Biossensoriais , Sepse , Humanos , Técnicas Biossensoriais/métodos , Sepse/diagnóstico , Diagnóstico Precoce , Biomarcadores , Sistemas Automatizados de Assistência Junto ao Leito
7.
J Breath Res ; 16(2)2022 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-35051905

RESUMO

The composition of exhaled breath derives from an intricate combination of normal and abnormal physiological processes that are modified by the consumption of food and beverages, circadian rhythms, bacterial infections, and genetics as well as exposure to xenobiotics. This complexity, which results wide intra- and inter-individual variability and is further influenced by sampling conditions, hinders the identification of specific biomarkers and makes it difficult to differentiate between pathological and nominally healthy subjects. The identification of a 'normal' breath composition and the relative influence of the aforementioned parameters would make breath analyses much faster for diagnostic applications. We thus compared, for the first time, the breath composition of age-matched volunteers following a vegan and a Mediterranean omnivorous diet in order to evaluate the impact of diet on breath composition. Mixed breath was collected from 38 nominally healthy volunteers who were asked to breathe into a 2 l handmade Nalophan bag. Exhalation flow rate and carbon dioxide values were monitored during breath sampling. An aliquot (100 ml) of breath was loaded into a sorbent tube (250 mg of Tenax GR, 60/80 mesh) before being analyzed by thermal desorption-gas chromatography-mass spectrometry (TD-GC-MS). Breath profiling using TD-GC-MS analysis identified five compounds (methanol, 1-propanol, pentane, hexane, and hexanal), thus enabling differentiation between samples collected from the different group members. Principal component analysis showed a clear separation between groups, suggesting that breath analysis could be used to study the influence of dietary habits in the fields of nutrition and metabolism. Surprisingly, one Italian woman and her brother showed extremely low breath isoprene levels (about 5 pbv), despite their normal lipidic profile and respiratory data, such as flow rate and pCO2. Further investigations to reveal the reasons behind low isoprene levels in breath would help reveal the origin of isoprene in breath.


Assuntos
Dieta Vegana , Compostos Orgânicos Voláteis , Biomarcadores/análise , Testes Respiratórios/métodos , Expiração , Feminino , Cromatografia Gasosa-Espectrometria de Massas , Humanos , Masculino , Compostos Orgânicos Voláteis/análise
8.
Electrophoresis ; 32(22): 3295-304, 2011 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-22025198

RESUMO

We present a theoretical model to determine the effective zeta potential ζ(eff) in microfluidic channels where an embedded, insulated gate electrode allows for external tuning of a portion of the channel surface charge. In addition, we derive a method to determine ζ(eff) in such channels, for any value of salt concentration, using the solution displacement technique. To do so, we simulate typical current-monitoring measurements using our model, and highlight the experimental parameters that lead to inaccurate results using this procedure with an heterogenous channel. Our method corrects for such inaccuracies by using our model with experimental data to find the correct value of ζ(eff) . Finally, we perform experiments to demonstrate our method and the use of our model with a silica-PMDS microchannel system with an embedded Ti-Au-Ti gate electrode that covers 50% of the bottom surface of the channel. We show that our theory captures the salient features of our experiments, thereby offering a useful tool to predict effective zeta potential in channels with a nonuniform zeta potential.


Assuntos
Fenômenos Eletromagnéticos , Microfluídica/instrumentação , Microfluídica/métodos , Modelos Químicos , Simulação por Computador , Eletrodos , Ouro/química , Dióxido de Silício/química , Titânio/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA