1.
Knee ; 49: 52-61, 2024 Jun 06.
Artigo em Inglês | MEDLINE | ID: mdl-38848658

RESUMO

BACKGROUND: There is increasing use of Robotic-Assisted (RA) and personalized alignment techniques in total knee arthroplasty (TKA). The hypothesis of this study was that RA TKA would result in fewer soft-tissue releases, and that fewer soft-tissue releases would be associated with improved clinical outcomes. METHODS: A retrospective review of an internal company registry was conducted for all primary TKAs performed from Jan 1, 2014, through a database extract date of Nov 4, 2022. These were grouped by whether there was an intentional soft-tissue release performed (STR) during the surgery or not (NSTR) and whether RA was utilized. The incidence of STR was compared between RA-TKAs and those performed with manual instrumentation. Knee Society Score (KSS) and Knee Society Function Scores (KSFS) were collected at 6 months, 1 year and 2 years. Kaplan-Meier survivorship was performed. RESULTS: The incidence of STR was significantly lower for RA vs. Manual (43.81% Vs 86.62%, p < 0.0001). The TKAs with NSTR had higher KSFS compared to those with STR at 6 months (84.73 Vs. 77.51, p < 0.0001), 1 year (89.87 Vs. 83.54, p < 0.0001) and 2 years (90.09 Vs. 82.65, p < 0.0001). There was no difference in survivorship, or KSS at any time point. However, the NSTR group had improved KSS pain sub score at 2 years. CONCLUSION: The results of this observational, retrospective analysis found that the incidence of soft-tissue release was lower with RA-TKA. Further, regardless of if RA was used, avoiding releases was associated with improved KSFS and KSS pain scores through 2 years post-operatively.

2.
Proc Inst Mech Eng H ; 227(4): 345-9, 2013 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-23637209

RESUMO

Clinical studies have found high wear rates, elevated ion levels and high revision rates of large-diameter metal-on-metal surface replacement bearings in some patients, which have been associated with edge loading of the head on the rim of the cup. We have simulated increased wear and ion levels in metal-on-metal bearings in vitro by introducing variations in translational and rotational positioning of the components, which reproduces stripe wear on the femoral head, cup rim wear and clinically relevant large as well as small wear particles. There is interest in technologies such as surface engineering, which might reduce metal wear and the release of wear particles and ions. Reduced wear with surface-engineered surface replacements compared to metal-on-metal controls has been reported under standard walking conditions with correctly aligned and concentric components. In this in vitro study, the wear of chromium nitride surface-engineered metal-on-metal bearings under conditions of microseparation associated with translational and rotational malpositioning of the components was investigated and the results were compared with a previously reported study of metal-on-metal bearings under the same conditions. Simulations were conducted using our unique hip simulation microseparation methodologies, which reproduce accelerated wear in metal-on-metal bearings and have previously been clinically validated with ceramic-on-ceramic bearings. Four of the six surface-engineered bearings had evidence of head contact on the rim of the cup, which produced stripe wear on the femoral head. Four of the six surface-engineered bearings (two without stripe and two with stripe wear) had lower wear than the previously reported high wearing metal-on-metal bearings. At 2 million cycles, two of the surface-engineered bearings had substantially increased wear rates, four times higher than the high wear rates previously reported for metal-on-metal bearings under the same conditions. There was wear through and cohesive failure of the thick atomic emission physical vapour deposition (AEPVD) chromium nitride (CrN) coating. At this point, the study was stopped to investigate the failure mode. This study highlights the need to pre-clinically investigate the tribology of new bearings under a wide set of clinical conditions as demonstrated by our stratified approach for enhanced reliability (SAFER) simulation methods. In adopting this SAFER approach to pre-clinical simulation testing of new bearings, it is important to communicate the failures as well as successes of technologies arising from the research, in order that the wider community can benefit from the analysis of the pre-clinical failure modes.


Assuntos
Prótese de Quadril , Metais/química , Artroplastia de Quadril/métodos , Fenômenos Biomecânicos , Cromo/química , Simulação por Computador , Cabeça do Fêmur/patologia , Teste de Materiais , Nitrogênio/química , Desenho de Prótese , Falha de Prótese , Reprodutibilidade dos Testes , Estresse Mecânico , Propriedades de Superfície
3.
Arch Orthop Trauma Surg ; 131(4): 471-4, 2011 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-20690027

RESUMO

INTRODUCTION: A study conducted to establish the most accurate combination of questionnaire and physical signs for the diagnosis of carpal tunnel syndrome. METHOD: Nerve conduction studies confirmed 70 patients with having carpal tunnel syndrome who were enrolled along with 70 age- and sex-matched controls. Patients were assessed using a symptom questionnaire, Phalen's test, Hoffmann-Tinel's sign, hand elevation test, carpal compression test, tourniquet test, pressure aesthesiometry and two-point discrimination. RESULTS: Through multivariate analysis, the best combination of tests was tourniquet, carpal compression and Phalen's tests but the difference between these and hand elevation test alone was negligible. CONCLUSION: The hand elevation test may be used in isolation and is superior to questionnaires and other physical signs in the clinical diagnosis of carpal tunnel syndrome.


Assuntos
Síndrome do Túnel Carpal/diagnóstico , Adulto , Idoso , Idoso de 80 Anos ou mais , Síndrome do Túnel Carpal/fisiopatologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Condução Nervosa , Exame Físico , Curva ROC , Inquéritos e Questionários
4.
J Biomed Mater Res B Appl Biomater ; 95(2): 263-8, 2010 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-20860044

RESUMO

Ceramic-on-ceramic (CoC) bearings in total hip replacements (THRs) have shown low wear volumes under standard gait in hip simulator studies. However, clinical reports have indicated variations in wear rates and formation of stripe-like wear area on the ceramic femoral heads. The aim of this study was to investigate the influence of cup inclination angle and microseparation on the wear of CoC bearings in THRs. The six station Leeds II Physiological Anatomical Joint Simulator was used to investigate the wear of 28 mm diameter alumina matrix composite ceramic bearings (BIOLOX® delta). It was shown that increasing the cup inclination angle from 55° to 65° had no significant effect on the wear rate of BIOLOX® delta CoC under both standard gait and microseparation conditions in this in vitro study. Under standard gait conditions, the mean wear rate for both cup inclination angle conditions was very low at 0.05 mm(3)/million cycles. The introduction of microseparation to the standard gait cycle increased the mean wear rates to 0.13 mm(3)/million cycles for the cup inclination angle of 55° and 0.11 mm(3)/million cycles for that of 65°. The level of increased wear with microseparation was not dependent on cup angle. A stripe of wear on the head also formed, with corresponding superior rim wear on the cup. The wear rates obtained were low compared to the HIPed third generation alumina ceramic (BIOLOX® forte) tested under the same adverse conditions (1.84 mm(3)/million cycles). BIOLOX® delta has shown lower wear than previous ceramic materials used in THR under adverse conditions.


Assuntos
Artroplastia de Quadril , Cerâmica , Teste de Materiais , Fluoroscopia , Modelos Teóricos , Propriedades de Superfície
5.
Hand Surg ; 15(2): 71-3, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-20672392

RESUMO

Katz and Stirrat devised a hand diagram, which uses subjective information from the patient for the diagnosis of carpal tunnel syndrome (CTS). They reported a good result. We tested the inter-observer and intra-observer reliability of this hand diagram. Twenty five consecutive patients with a diagnosis of CTS, 25 with other common hand and wrist problems but CTS and 25 healthy individuals were prospectively recruited. Each patient filled in a hand diagram. Two experienced hand surgeon scored the diagrams blindly on two different sittings four-week apart. The intra-class correlation coefficient (ICC) and Cohen's Kappa were used for intra and inter-observer reliability respectively. The intra-observer agreement was poor (ICC 95% 0.33-0.65) and inter-observer was fair (Kappa = 0.241). This study does not support the use of Katz and Stirrat Hand Diagram for the diagnosis of carpal tunnel syndrome in place if a thorough clinical examination.


Assuntos
Síndrome do Túnel Carpal/diagnóstico , Inquéritos e Questionários , Síndrome do Túnel Carpal/cirurgia , Humanos , Variações Dependentes do Observador , Valor Preditivo dos Testes , Sensibilidade e Especificidade
6.
Mutat Res ; 688(1-2): 53-61, 2010 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-20227425

RESUMO

Humans are exposed to chromium and cobalt in industry, from the environment and after joint replacement surgery from the CoCr alloy in the implant. In this study we have investigated whether Cr(III), Cr(VI), Co(II) and Cr in combination with Co could induce chromosome aberrations in human fibroblasts in vitro at the same concentrations that have been found in the peripheral blood of exposed humans. We used 24 colour M-FISH as a sensitive way to detect translocations and aneuploidy and examined the effects of a 24-h exposure and its consequences up to 30 days after the exposure in order to record genomic instability and/or repair. At these physiological doses the metals induced predominantly numerical rather than structural aberrations. Co was the least reactive and Cr(VI) especially in combination with Co the most. All metals at the highest physiological doses caused simple (gain or loss of 3 or less chromosomes) and complex (more than 49 chromosomes) aneuploidy. All metals at the lowest physiological dose caused a significant increase of total aberrations. Cr(VI) was much more effective than Cr(III) in causing chromosome fragments, which were only induced at the highest doses. There was a slow resolution of aneuploidy with time after exposure. This involved a reduction in the proportion of aneuploid cells and a reduction of the number of chromosomes within cells showing complex aneuploidy. We conclude that these metal ions can cause chromosome aberrations at physiological concentrations and that their main effect is aneugenic.


Assuntos
Aneugênicos/toxicidade , Cromo/toxicidade , Cobalto/toxicidade , Instabilidade Genômica , Células Cultivadas , Aberrações Cromossômicas , Dano ao DNA , Reparo do DNA , Fibroblastos , Humanos
7.
Clin Orthop Relat Res ; 467(9): 2259-65, 2009 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-19363640

RESUMO

High wear rates and high patient ion levels have been associated with high (> 55 degrees) cup inclination angles for metal-on-metal surface replacements. Wear rates and patterns have been simulated for ceramic-on-ceramic bearings by applying microseparation to replicate head offset deficiency. We tested 39-mm metal-on-metal surface replacements (n = 5) in a hip simulator with (A) an increased cup inclination angle of 60 degrees and (B) an increased cup inclination angle and microseparation over 2 million cycles. (A) resulted in a ninefold increase in wear rate and (B) resulted in a 17-fold increase in wear rate compared to a standard gait condition study. Wear particles produced under microseparation conditions were larger than those produced under standard conditions but of similar shape (round to oval). The data suggest both head and cup position influence the wear of surface replacements; we believe it likely bearings with high wear either have a high cup inclination angle, an offset deficient head, or a combination of both.


Assuntos
Artroplastia de Quadril/instrumentação , Prótese de Quadril , Desenho de Prótese , Falha de Prótese , Artroplastia de Quadril/métodos , Humanos , Teste de Materiais , Tamanho da Partícula , Suporte de Carga
8.
J Biomed Mater Res B Appl Biomater ; 90(2): 558-65, 2009 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-19195030

RESUMO

Increased patient blood and serum levels of Co and Cr and dissemination of metal wear particles throughout organs and tissues are the primary concerns with metal-on-metal surface replacements. Surface engineering, providing a ceramic bearing surface on a metal substrate, could provide a solution. This study investigated thick (>10 microm) arc evaporation plasma vapor deposition chromium nitride (CrN) coated surface replacements in terms of wear, ion levels, and wear particles in a 10 million cycle hip simulator study, compared to a contemporary metal-on-metal surface replacement. The ion levels were measured by inductively coupled plasma mass spectroscopy. The wear particles were imaged by field emission gun scanning electron microscopy. The CrN-coated bearings had 80% lower wear than the MoM controls. The Cr and Co ion levels in the lubricant of the CrN bearings were 73 and 98% lower than in the MoM controls. The wear particles produced were in the nanometer size range and round to oval in morphology. The CrN coating could provide a reduction in the wear and ion release of MoM surface replacements, thereby reducing the perceived risks to the patient associated with these prostheses.


Assuntos
Artroplastia de Quadril/instrumentação , Artroplastia de Quadril/métodos , Cerâmica/química , Cromo/química , Materiais Revestidos Biocompatíveis/química , Cobalto/química , Prótese de Quadril , Humanos , Íons , Teste de Materiais , Metais/química , Microscopia Eletrônica de Varredura/métodos , Compostos de Nitrogênio/química , Desenho de Prótese , Falha de Prótese , Propriedades de Superfície
9.
Int Orthop ; 33(1): 181-5, 2009 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-17972075

RESUMO

This article presents a prospective longitudinal study to determine the cut-off values for change scores of DASH, Levine, and Kamath questionnaires to distinguish clinical improvement following carpal tunnel surgery. Fifty-four patients (40 female, 14 male), with positive nerve conduction studies, were prospectively followed up. Three questionnaires (DASH, Levine, and Kamath) were posted to patients at four and two weeks prior to their operation and then six weeks following surgery. A patient global impression of change (PGIC) score was completed for patients to rate the overall change in their symptoms. According to the PGIC, 93% of patients improved. The cut-off values for raw change scores that best define clinically significant improvement following carpal tunnel release were 20.9 for DASH, 0.47 for Levine, and 1.97 for the Kamath questionnaire. This study provides a methodological framework for identifying clinically significant changes following treatment. A questionnaire follow-up of patients is now possible using the data provided.


Assuntos
Síndrome do Túnel Carpal/fisiopatologia , Síndrome do Túnel Carpal/cirurgia , Avaliação da Deficiência , Procedimentos Ortopédicos/métodos , Avaliação de Resultados em Cuidados de Saúde/métodos , Feminino , Seguimentos , Inquéritos Epidemiológicos , Humanos , Estudos Longitudinais , Masculino , Pessoa de Meia-Idade , Condução Nervosa/fisiologia , Estudos Prospectivos , Sensibilidade e Especificidade , Resultado do Tratamento
10.
J Bone Joint Surg Am ; 90 Suppl 3: 111-7, 2008 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-18676945

RESUMO

BACKGROUND: Clinical studies have indicated that the angular position of the acetabular cup may influence wear in metal-on-metal total hip bearings. A high cup angle in comparison to the anatomical position may lead to the head being constrained by the superior lateral surface and rim of the cup, thus potentially changing the location of the contact zone between the head and the cup. The aim of this study was to test the hypothesis that both a steep cup angle and a lateralized position of the head can increase head contact on the superior rim of the cup, with the consequence of increased wear. METHODS: Hip-joint simulator studies of metal-on-metal bearings were undertaken with cup angles of 45 degrees and 55 degrees . The femoral head was either aligned to the center of the cup or placed in a position of microlateralization. Wear was measured gravimetrically over 5 million cycles. RESULTS: A steep cup angle of 55 degrees showed significantly higher long-term steady-state wear than a standard cup angle of 45 degrees (p < 0.01). The difference was fivefold. Microlateralization of the head resulted in a fivefold increase in steady-state wear compared with a centralized head. The combination of a steep cup angle and a microlateralized head increased the steady-state wear rate by tenfold compared with a standard cup angle with a centralized head. CONCLUSIONS: These studies support the hypothesis that both an increased cup angle and a lateral head position increase wear in metal-on-metal hip prostheses.


Assuntos
Prótese de Quadril , Fenômenos Biomecânicos , Cabeça do Fêmur , Fricção , Humanos , Desenho de Prótese , Falha de Prótese , Vitálio
11.
J Biomed Mater Res B Appl Biomater ; 87(1): 163-72, 2008 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-18386846

RESUMO

Hip resurfacing arthroplasty has become a popular alternative to conventional hip surgery. Surface replacements with bearing sizes of 55 mm (n = 5) and 39 mm (n = 5) were tested in a hip simulator for 15 million cycles (Mc). Wear debris was isolated from the serum lubricant and characterized by field emmitting gun scanning electorn microscopy, and ion levels were measured via inductively coupled plasma mass spectroscopy at intervals throughout the test. The 39 mm bearings showed significantly greater bedding in volumetric wear (2.58 mm(3)) compared with the 55 mm bearings (1.15 mm(3)). There was no significant difference between the steady state wear rates (1-15 Mc) between the two sizes (0.10 and 0.09 mm(3)/Mc, respectively); however, this parity only became clear after 7 Mc. The wear debris isolated was oval in morphology with a mean particle size of 28 nm and a range of 9-108 nm. The Co levels measured at 0.13 Mc were significantly greater than at 3.6 Mc for both bearing sizes (10926 ppb and 176 ppb, respectively). After 0.5 Mc, the Co levels from the 39 mm bearings were significantly higher than the 55 mm (11,007 vs. 1475 ppb). The wear results support previous findings showing that increasing the femoral head size decreased volumetric bedding in wear. The ion levels measured suggest both bearing sizes have similar initial wear rates; however, the 55 mm bearings reach steady state wear more rapidly.


Assuntos
Artroplastia de Quadril/instrumentação , Prótese de Quadril , Desenho de Prótese , Ligas de Cromo , Cobalto , Análise de Falha de Equipamento , Humanos , Teste de Materiais , Tamanho da Partícula , Propriedades de Superfície