Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 65
Filtrar
2.
Cureus ; 16(2): e55136, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38558586

RESUMO

INTRODUCTION: The selection of the most optimal fixation method for fractures of the distal femur, whether intramedullary nail (NL), lateral locking plate (PL), or nail/plate (NP) is not always clear. This study retrospectively evaluates surgical patients with distal femur fractures and introduces a pilot study using cluster analysis to identify the most optimal fracture fixation method for a given fracture type. METHODS: This is a retrospective cohort study of patients 18 years and older with an isolated distal femur fracture who presented to our Level-1 trauma center between January 1, 2012, and December 31, 2022, and obtained NL, PL, or NP implants. Patients with polytrauma and those without at least six months of follow-up were excluded. A chart review was used to obtain demographics, fracture classification, fixation method, and postoperative complications. A cluster analysis was performed. The following factors were used to determine a successful outcome: ambulatory status pre-injury and 6-12 months postoperatively, infection, non-union, mortality, and implant failure. RESULTS: A total of 169 patients met inclusion criteria. No statistically significant association between the fracture classification and fixation type with overall outcome was found. However, patients treated with an NP (n = 14) had a success rate of 92.9% vs only a 68.1% success rate in those treated with a PL (n = 116) (p = 0.106). The most notable findings in the cluster analysis (15 total clusters) included transverse extraarticular fractures demonstrating 100% success if treated with NP (n = 6), 50% success with NL (n=2), and 78.57% success with PL fixation (n=14). NP constructs in complete articular fractures demonstrated success in 100% of patients (n = 5), whereas 77.78% of patients treated with NL (n = 9) and 61.36% of those treated with PL (n = 44). CONCLUSIONS: Plate fixation was the predominant fixation method used for distal third femur fractures regardless of fracture classification. However, NP constructs trended towards improved success rates, especially in complete intraarticular and transverse extraarticular fractures, suggesting the potential benefit of additional fixation with these fractures. Cluster analysis provided a heuristic way of creating patient profiles in patients with distal third femur fractures. However, a larger cohort study is needed to corroborate these findings to ultimately develop a clinical decision-making tool that also accounts for patient specific characteristics.

3.
3D Print Med ; 10(1): 7, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38427157

RESUMO

BACKGROUND: The extended trochanteric osteotomy (ETO) is a surgical technique utilized to expose the intramedullary canal of the proximal femur, protect the soft tissues and promote reliable healing. However, imprecise execution of the osteotomy can lead to fracture, soft tissue injury, non-union, and unnecessary morbidity. We developed a technique to create patient specific, 3D-printed cutting guides to aid in accurate positioning of the ETO and improve osteotomy quality and outcomes. METHODS: Patient specific cutting guides were created based on CT scans using Synopysis Simpleware ScanIP and Solidworks. Custom 3D printed cutting guides were tested on synthetic femurs with foam cortical shells and on cadaveric femurs. To confirm accuracy of the osteotomies, dimensions of the performed osteotomies were compared to the virtually planned osteotomies. RESULTS: Use of the patient specific ETO cutting guides resulted in successful osteotomies, exposing the femoral canal and the femoral stem both in synthetic sawbone and cadaveric testing. In cadaveric testing, the guides allowed for osteotomies without fracture and cuts made using the guide were accurate within 6 percent error from the virtually planned osteotomy. CONCLUSION: The 3D-printed patient specific cutting guides used to aid in ETOs proved to be accurate. Through the iterative development of cutting guides, we found that a simple design was key to a reliable and accurate guide. While future clinical trials in human subjects are needed, we believe our custom 3D printed cutting guide design to be effective at aiding in performing ETOs for revision total hip arthroplasty surgeries.

4.
J Vasc Surg Cases Innov Tech ; 9(3): 101218, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37799843

RESUMO

Supracondylar humerus fractures are common in children and can compromise the brachial artery in 5% to 15% of cases. A 4-year-old boy with a left supracondylar fracture developed upper extremity ischemia after pinning of the fracture. Computed tomography angiography revealed cutoff of flow in the brachial artery. Intraoperatively, he was found to have bands tethering the artery into the fracture, obstructing the blood flow. The orthopedic pins were removed, and the constraining bands were lysed to free the artery, with reconstitution of flow confirmed by intraoperative angiography. The fracture was reduced and stabilized, and the patient recovered well with normal arterial flow on follow-up ultrasound after 3 months.

5.
Clin Biomech (Bristol, Avon) ; 110: 106129, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37871506

RESUMO

BACKGROUND: The locking plate is a common device to treat distal femur fractures. Healing is affected by construct stiffness, thus many surgeon-controlled variables such as working length have been examined for their effects on strain at the fracture. No convenient analytical model which aids surgeons in determining working length has yet been described. We propose an analytical model and compare it to finite element analysis and cadaveric biomechanical testing. METHODS: First, an analytical model based on a cantilever beam equation was derived. Next, a finite element model was developed based on a CT scan of a "fresh-frozen" cadaveric femur. Third, biomechanical testing in single-leg stance loading was performed on the cadaver. In all methods, strain at the fracture was recorded. An ANCOVA test was conducted to compare the strains. FINDINGS: In all models, as the working length increased so did strain. For strain at the fracture, the shortest working length (35 mm) had a strain of 8% in the analytical model, 9% in the finite element model, and 7% for the cadaver. The longest working length (140 mm) demonstrated strain of 15% in the analytical model, and the finite element and biomechanical tests both demonstrated strain of 14%. INTERPRETATION: The strain predicted by the analytical model was consistent with the strain observed in both the finite element and biomechanical models. As demonstrated in existing literature, increasing the working length increases strain at the fracture site. Additional work is required to refine and establish validity and reliability of the analytical model.


Assuntos
Fraturas do Fêmur , Fixação Interna de Fraturas , Humanos , Reprodutibilidade dos Testes , Parafusos Ósseos , Fenômenos Biomecânicos , Placas Ósseas , Fraturas do Fêmur/cirurgia , Análise de Elementos Finitos , Cadáver
6.
Cureus ; 15(5): e39503, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-37366446

RESUMO

Pain control after total hip arthroplasty is associated with patient satisfaction, early discharge, and improved surgical outcomes. Two commonly utilized opioid-reducing analgesic modalities are periarticular injection (PAI) by surgeons and motor-sparing peripheral nerve block (PNB) by anesthesiologists. We present a case contrasting PAI and PNB in a single patient undergoing bilateral total hip arthroplasty. For the left hip, the patient received preoperative transmuscular quadratus lumborum, femoral nerve, and lateral femoral cutaneous nerve blocks using a combination of low-concentration local anesthetic and glucocorticoids. For the right hip, the patient received an intraoperative PAI with liposomal bupivacaine. The patient's pain scores and recovery were evaluated for three months postoperatively. The patient's pain scores on postoperative day (POD) zero to five were consistently lower in the left hip than in the right hip. For this patient undergoing bilateral hip replacement, preoperative PNBs were superior to PAI for postoperative pain control.

7.
Foot Ankle Int ; 44(7): 665-674, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37226736

RESUMO

BACKGROUND: Ankle, hindfoot, and midfoot arthrodesis surgeries are standard procedures performed in orthopaedics to treat pain and functional disabilities. Although fusions can effectively improve pain and quality of life, nonunions remain a significant concern for surgeons. With the increased availability of computed tomography (CT), more surgeons rely on this modality for increased accuracy in determining whether a fusion was successful. The objective of this study was to report the rates of CT-confirmed fusion following ankle, hindfoot, or midfoot arthrodesis. METHODS: A systematic review was performed using EMBASE, Medline, and Cochrane central register from January 2000 to March 2020. Inclusion criteria included studies with adults (<18 years) that received 1 or multiple fusions of the ankle, hindfoot, or midfoot. At least 75% of the study cohort must have been evaluated by CT postoperatively. Basic information was collected, including journal, author, year published, and level of evidence. Other specific information was collected, including patient risk factors, fusion site, surgical technique and fixation, adjuncts, union rates, criteria for successful fusion (%), and time of CT. Once data were collected, a descriptive and comparative analysis was performed. RESULTS: Included studies (26, n = 1300) had an overall CT-confirmed fusion rate of 78.7% (69.6-87.7). Individual joints had an overall fusion rate of 83.0% (73-92.9). The highest rate of union was in the talonavicular joint (TNJ). CONCLUSION: These values are lower than previous studies, which found the same procedures to have greater than 90% fusion rates. With these updated figures, as confirmed by CT, surgeons will have better information for clinical decision making and when having informed consent conversations.


Assuntos
Tornozelo , Qualidade de Vida , Adulto , Humanos , Articulação do Tornozelo/diagnóstico por imagem , Articulação do Tornozelo/cirurgia , Tomografia Computadorizada por Raios X , Artrodese/métodos , Dor/etiologia , Estudos Retrospectivos , Resultado do Tratamento
8.
Geriatr Orthop Surg Rehabil ; 13: 21514593221141376, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36533207

RESUMO

Introduction: Geriatric patients who suffer femoral neck fractures have high morbidity and mortality. Prophylactic fixation of the femoral neck is a potential avenue to reduce the incidence of femoral neck fractures. We studied 3 different implants traditionally used to stabilize the femoral neck: 6.5 mm cannulated screws (CANN), the femoral neck system (FNS) (Depuy Synthes), and the dynamic hip screw (DHS) (Depuy Synthes). Materials and Methods: Five osteoporotic Sawbone femurs were used for each model and a control group. Two scenarios were investigated: single leg stance to measure construct stiffness and lateral impact to measure construct stiffness, energy to fracture, and qualitative examination of fracture patterns. Stiffness for each femur and energy to fracture for the lateral impact scenario were calculated and compared between groups using one-way ANOVA. Results: DHS showed significantly higher stiffness than the other 2 implants and the control in single leg stance. In the lateral impact scenario, the DHS and CANN were significantly stiffer FNS and the control. Femurs implanted with CANN tended to fracture at the greater trochanter while FNS fractured in a transverse subtrochanteric pattern, and DHS fractured obliquely in the subtrochanteric region. Discussion: FNS and DHS experienced fracture patterns less amenable to surgical correction. CANN and DHS proved better able to resist external forces in the lateral fall scenario. CANN also proved better able to resist external forces in the single leg stance scenario and experienced a more amenable fracture pattern in the lateral fall scenario. Conclusions: FNS was less able to resist external forces compared with the other implants. This work informs the potential implications between the choice of implants that, although historically have not been used prophylactically, may be considered in the future for prophylactic stabilization of the femoral neck. Cadaveric study and clinical trials are recommended for further study.

9.
Geriatr Orthop Surg Rehabil ; 13: 21514593221135117, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36393901

RESUMO

Introduction: Hip fractures cause significant morbidity and mortality for geriatric patients, and incidence is increasing as the population ages. Following a primary hip fracture, up to 20% may suffer a contralateral hip fracture within 5 years despite fracture risk reduction measures, including fall prevention and osteoporosis pharmacologic treatment. The aim of this study is to assess whether insertion of the Femoral Neck System (Depuy Synthes, West Chester, PA) into the contralateral proximal femur may strengthen the bone and decrease the incidence of contralateral hip fractures. Materials and Methods: ScanIP, an image processing software was used to produce 3-dimensional models of a cadaver femur with the implanted device. Models were meshed and exported to Abaqus for finite element analysis to evaluate the device's ability to reduce stress in the proximal femur. Results were analyzed for element-wise volume and von-Mises stresses. Results: The implant reduced peak stress and bone failure at all levels of bone quality. Specifically in osteoporotic bone, the implant decreased peak stress by 27%, proximal femur trabecular bone failure by 5% and cortical bone failure by 100% in the femoral neck. Conclusions: Our results from computer generated finite element analyses indicate that the Femoral Neck System may strengthen an osteoporotic proximal femur in the event of a lateral fall. Further investigation with expanded finite element analysis and cadaveric biomechanical studies are needed to validate these results.

11.
3D Print Med ; 8(1): 19, 2022 Jul 04.
Artigo em Inglês | MEDLINE | ID: mdl-35781846

RESUMO

BACKGROUND: The goal of stabilization of the femoral neck is to limit morbidity and mortality from fracture. Of three potential methods of fixation, (three percutaneous screws, the Synthes Femoral Neck System, and a dynamic hip screw), each requires guide wire positioning of the implant(s) in the femoral neck and head. Consistent and accurate positioning of these systems is paramount to reduce surgical times, stabilize fractures effectively, and reduce complications. To help expedite surgery and achieve ideal implant positioning in the geriatric population, we have developed and validated a surgical planning methodology using 3D modelling and printing technology. METHODS: Using image processing software, 3D surgical models were generated placing guide wires in a virtual model of an osteoporotic proximal femur sawbone. Three unique drill guides were created to achieve the optimal position for implant placement for each of the three different implant systems, and the guides were 3D printed. Subsequently, a trauma fellowship trained orthopedic surgeon used the 3D printed guides to position 2.8 mm diameter drill bit tipped guide wires into five osteoporotic sawbones for each of the three systems (fifteen sawbones total). Computed Tomography (CT) scans were then taken of each of the sawbones with the implants in place. 3D model renderings of the CT scans were created using image processing techniques and the displacement and angular deviations at guide wire entry to the optimal sawbone model were measured. RESULTS: Across all three percutaneous screw guide wires, the average displacement was 3.19 ± 0.12 mm and the average angular deviation was 4.10 ± 0.17o. The Femoral Neck System guide wires had an average displacement of 1.59 ± 0.18 mm and average angular deviation of 2.81 ± 0.64o. The Dynamic Hip Screw had an average displacement of 1.03 ± 0.19 mm and average angular deviation of 2.59 ± 0.39o. CONCLUSION: The use of custom 3D printed drill guides to assist with the positioning of guide wires proved to be accurate for each of the three types of surgical strategies. Guides which are used to place more than 1 guide wire may have lower positional accuracy, as the guide may shift during multiple wire insertions. We believe that personalized point of care drill guides provide an accurate intraoperative method for positioning implants into the femoral neck.

12.
Arthroplast Today ; 15: 153-158, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35586609

RESUMO

Imageless computer-assisted navigation (CAN) excels in the post-traumatic arthritis and complex revision case setting when altered anatomy and landmarks are inaccurate references for cup positioning. We describe the case of an adult male patient who suffered an acetabular fracture which was treated nonoperatively. He subsequently developed post-traumatic arthritis and underwent an anterior approach total hip arthroplasty 25 years later. Postoperatively, he developed recurrent hip instability due to malpositioned components. We describe the use of imageless CAN during revision total hip arthroplasty to correct malpositioned components, with 3-year follow-up without dislocation. In these complex cases, CAN reduces the risk of component malpositioning and joint instability.

13.
J Am Acad Orthop Surg ; 30(20): 979-983, 2022 10 15.
Artigo em Inglês | MEDLINE | ID: mdl-35551159

RESUMO

INTRODUCTION: Arthroplasty has become the standard of care for displaced femoral neck fractures in the geriatric cohort. However, details regarding optimal implant design and fixation strategy continue to be debated. We sought to determine whether cemented or press-fit hemiarthroplasties were more advantageous in terms of revision surgery, contralateral hip fractures, hospital length of stay, mortality rates, and survival. METHODS: All geriatric fragility hip fractures at a level 1 trauma center (2014 to 2019) were retrospectively reviewed for the fracture pattern, fixation methodology, and outcome, yielding 707 femoral neck fractures treated with hemiarthroplasty (309 cemented and 398 press fit). The final follow-up was either date of death or final encounter. Major end points were revision surgery, contralateral fracture, and death. A Z-score test of two proportions was used for dichotomous variables, and a two-tailed t -test was used for continuous variables. Cox proportional hazard was used for revision surgery-free survival between groups, adjusting for age, sex, and American Society of Anesthesiologists status. RESULTS: Patients who underwent press-fit hemiarthroplasty had a significantly higher rate of revision surgery (7.8% vs 3.9%; P = 0.006). Press-fit cases had a trend toward a decreased risk of contralateral fracture (13% vs 9.8%; P = 0.12), although this did not reach significance. Both groups had similar length of stay ( P = 0.08) and death rates ( P = 0.39). Of those who died, there was a trend toward longer survival in patients who received a press-fit hemiarthroplasty (413 vs 615 days; P < 0.001). There was a trend toward longer survival without repeat surgery in the cemented group without reaching significance (hazard ratio, 0.66 [0.34 to 1.23]; P = 0.201). CONCLUSION: In this study, we found a markedly longer survival time after press-fit hemiarthroplasty, which we believe reflects surgeons' tendencies to cement the femoral prosthesis in patients with more comorbidities. However, press-fit hemiarthroplasties were more likely to result in repeat procedures on the same hip. Displaced geriatric femoral neck fractures may benefit from a cemented rather than press-fit hemiarthroplasty.


Assuntos
Artroplastia de Quadril , Fraturas do Colo Femoral , Hemiartroplastia , Prótese de Quadril , Idoso , Artroplastia de Quadril/métodos , Cimentos Ósseos , Fraturas do Colo Femoral/cirurgia , Hemiartroplastia/métodos , Humanos , Reoperação , Estudos Retrospectivos , Resultado do Tratamento
15.
Geriatr Orthop Surg Rehabil ; 12: 21514593211055890, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34868723

RESUMO

INTRODUCTION: The frequency of hip fractures, a major cause of morbidity and mortality for geriatric patients, is expected to increase exponentially in the next few decades. The aim of this study is to assess the ability of stainless-steel cannulated screws to reduce the risk of a femoral neck fracture, if placed prophylactically prior to a fall. MATERIALS AND METHODS: We created finite element models from computed tomography (CT) scan-based 3D models of a geriatric patient through 3D-image processing and model generation software. We used linear finite element simulations to analyze the effect of cannulated screws in the proximal femur in single-leg stance and lateral fall, which were processed for peak von Mises stresses and element failure. FINDINGS: Prophylactically placed cannulated screws significantly reduced failure in an osteoporotic proximal femur undergoing lateral fall. Three implanted screws in an inverted triangle formation decreased proximal femoral trabecular failure by 21% and cortical failure by 5%. This reduction in failure was achieved with a 55% decrease in femoral neck failure and 14% in lateral cortex failure. CONCLUSION: Our results indicate that cannulated hip screws in an inverted triangle formation may strengthen an osteoporotic proximal femur in the event of a lateral fall. Mechanical testing on cadaveric or composite models is required to validate these results.

16.
Cureus ; 13(10): e18713, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34790468

RESUMO

Objective With the goal of guiding acute management of associated injuries motorcycle trauma patients, this study aims to identify patterns of associated injuries after motorcycle collisions using exploratory factor analysis. Methods We conducted a retrospective review at a Level 1 trauma center of all patients who presented after motorcycle collisions resulting in trauma system activations between July 2, 2002 and December 31, 2013. We performed exploratory factor analysis on this dataset to identify sets of injuries that cluster together. Results We identified 1,050 patients who presented for trauma after a motorcycle collision. These patients had 3,101 injuries, including 1,694 fractures. Using exploratory factor analysis, we developed a model with four latent factors that explained approximately half of the variance in injuries. These factors were defined by: head and cervical spine injuries; extremity injuries; abdomen, pelvis and upper extremity injuries; and shoulder girdle and thorax injuries. We also found a novel injury pattern relationship between forearm shaft/wrist and lower extremity injuries. Conclusions Motorcycle trauma results in distinct clusters of associated injuries likely due to common motorcycle collision patterns, most notably a novel relationship between forearm shaft/wrist and lower extremity injuries that merits further exploration, and could play a role during secondary survey.

17.
SICOT J ; 7: 29, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33929313

RESUMO

OBJECTIVE: The purpose of this study was to characterize and compare risk behaviors between motorcyclists and motor vehicle drivers who were involved in accidents and required hospitalization. The study focused on patients who were recently involved in motorcycle collisions (MCCs) and motor vehicle collisions (MVCs). METHODS: We identified 63 patients involved in MCCs and 39 patients involved in MVCs who were admitted to our level-1 trauma center from April 2014 to September 2015. These 102 patients completed a questionnaire designed to evaluate risky driving behaviors. Pearson's chi-squared tests and unpaired two-tailed t-tests were used to evaluate categorical and normally distributed continuous variables, respectively. Multivariable linear regression was used to analyze predictors of risk behavior. Significance was set at p < 0.05. RESULTS: When compared to patients involved in an MCC, patients involved in MVCs were more likely to be female (p = 0.007), drive more frequently (p < 0.001), and never perceive the risk of an accident (p = 0.036). MVC patients were more likely to have admitted to substance use on the day of the accident (p = 0.030), historically drive under the influence of drugs (p = 0.031), drive while tired (p < 0.001), drive while text messaging (p < 0.001), and speed while overtaking vehicles (p = 0.011). Overall, MVC patients engaged in more risk behaviors (3.3 ± 1.3 vs. 2.0 ± 1.5; p < 0.001) and were more likely to engage in multiple risk behaviors (p < 0.001). MVCs were associated with increased risk behavior, even after controlling for protective behaviors, driving history, and demographics (p = 0.045). CONCLUSIONS: Within our cohort of trauma patients at our institution, motor vehicle drivers were more likely than motorcyclists to engage in any one risk behavior and engage in a higher number of risk behaviors. In addition, motor vehicle drivers perceived their risk of a potential accident as lower than riding a motorcycle. Education initiatives should focus on motor vehicle driver safety interventions that reduce risk behaviors.

18.
SICOT J ; 7: 8, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33683193

RESUMO

OBJECTIVES: Upper extremity injuries following motorcycle crashes (MCC) incur increased healthcare costs and rehabilitation needs. We aim to characterize the epidemiology of MCC upper extremity injuries and identify factors that influence the severity of and cost of care for upper extremity injuries. METHODS: We performed a retrospective cohort analysis of 571 patients with upper extremity injuries after MCC at a level 1 trauma center from 2002 to 2013. We collected data pertaining to demographics, helmet use, toxicology, bony injury, Injury Severity Score (ISS), Glasgow Coma Scale (GCS), hospital length of stay (LOS), and cost. Continuous variables were compared using t-test or Wilcoxon rank test, depending on data distribution, and dichotomous variables were compared using Pearson's chi-squared or Fisher's exact tests. Regression models were used to evaluate the effect of intoxication or helmets on injury location, severity, cost of care, and LOS. RESULTS: The incidence of MCC upper extremity injury was 47.5%, with hand and forearm fractures the most common injuries (25.5% and 24.7% of total injuries). Intoxicated patients were more likely to have a high cost of care (p = 0.012), extended LOS (p = 0.038), plastic surgery involvement in their care (p = 0.038), but fewer upper extremity bony injuries (p = 0.019). Non-helmeted patients sustained less upper extremity bony injuries (p < 0.001) and upper extremity soft tissue injuries (p = 0.001), yet more severe injuries (ISS ≥ 30, p = 0.006 and GCS < 9, p < 0.01) than helmeted patients. CONCLUSION: Upper extremity injuries are common in motorcyclists. Despite vital protection for the brain and maxillofacial injury, helmeted MCC patients have an increased incidence of upper extremity injuries compared to non-helmeted patients, but overall have less severe injuries. Intoxicated patients have fewer upper extremity bony injuries, but the higher cost of care, and extended LOS. Therefore, even with the increased risk of injury helmets may expose to the upper extremity, helmets reduced overall morbidity and mortality. In addition to mandatory helmet laws, we advocate for further development of safety equipment focusing specifically on the prevention of upper extremity injuries.

19.
Hip Int ; 31(6): 812-819, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-32468868

RESUMO

INTRODUCTION: Traumatic anterior hip dislocations are subdivided to obturator (inferior) and pubic (superior) dislocations by Epstein's descriptive classification. This rare injury is thought to have favourable clinical outcomes. The incidence of associated femoral head and acetabular injuries has been low in past case series. We sought to revisit this injury and classification in the era of advanced imaging and contemporary surgical techniques. MATERIALS AND METHODS: A retrospective study of 15 patients treated for anterior hip dislocation was performed. Medical records were reviewed for demographic and surgical data. Imaging studies were revisited to determine direction of dislocation and associated fractures. Patients were assessed for pain, hip function using the modified Harris Hip Score (mHHS), hip range of motion and radiographic changes. Mean follow-up time was 3 years. RESULTS: Anterior dislocation occurred in an obturator (inferior), pubic (superior) or central direction. 9 patients had concomitant femoral head impaction and 7 patients suffered from acetabular fractures. 8 patients with an anterior hip dislocation underwent surgical treatment. This therapy, along with early range of motion and weight bearing, produced favourable clinical outcomes with 9 patients reporting no pain and an average mHHS of 83.8. 6 patients had heterotopic ossification at latest follow-up. CONCLUSIONS: Traumatic anterior hip dislocation is commonly associated with femoral head impaction and acetabular injuries which should be addressed operatively when appropriate to produce favourable results. In this paper, we propose a revision to the commonly used descriptive classification system.


Assuntos
Luxação do Quadril , Fraturas do Quadril , Acetábulo/diagnóstico por imagem , Acetábulo/cirurgia , Luxação do Quadril/diagnóstico por imagem , Luxação do Quadril/epidemiologia , Luxação do Quadril/cirurgia , Humanos , Estudos Retrospectivos , Resultado do Tratamento
20.
EFORT Open Rev ; 5(9): 544-548, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-33072406

RESUMO

Injuries sustained in motorcycle collisions can be organized into distinct patterns to improve recognition and treatment.Lowside, highside, topside, and collision are the four main categories of motorcycle crash types.Within those four crash types, mechanisms of injury include head-leading collisions, direct vertical impact, motorcycle radius, motorcycle thumb, fuel tank injures, limb entrapment, tyre-spoke injury, and crash modifying manoeuvre. Cite this article: EFORT Open Rev 2020;5:544-548. DOI: 10.1302/2058-5241.5.190090.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA