Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
J Clin Med ; 13(11)2024 May 22.
Artigo em Inglês | MEDLINE | ID: mdl-38892761

RESUMO

Background/Objectives: Despite procedural improvements, post-transcatheter aortic valve replacement (TAVR) conduction disorders remain high. Analyzing the data from a monocentric TAVR registry, this study aims to determine predictive factors for PPI (primary outcome), the indication for PPI, and long-term outcomes among these patients (secondary outcomes). Methods: Conducted at Clairval Hospital in Marseille, France, this retrospective study included all consecutive patients from June 2012 to June 2019. Clinical, electrocardiographic, echocardiographic, and procedural data were collected, with outcomes assessed annually. Logistic regression identified PPI predictors and survival analyses were performed. Results: Of the 1458 patients initially considered, 1157 patients were included. PPI was needed in 21.5% of patients, primarily for third-degree atrioventricular block (46.4%). Predictor factors for PPI included baseline right bundle branch block (ORadj 2.49, 95% CI 1.44 to 4.30; p = 0.001), longer baseline QRS duration (ORadj 1.01, 95% CI 1.00 to1.02, p = 0.002), and self-expandable valves (ORadj 1.82, 95% CI, 1.09 to 3.03; p = 0.021). Seven-year estimated mortality was higher in PPI (43.3%) vs. non-PPI patients (30.9%) (log rank p = 0.048). PPI was an independent predictive factor of death (ORadj 2.49, 95% CI 1.4 to 4.3; p = 0.002). Conclusions: This study reveals elevated rates of PPI post-TAVR associated with increased mortality. These results underscore the pressing necessity to refine our practices, delineate precise indications, and enhance the long-term prognosis for implanted patients.

2.
Arch Cardiovasc Dis ; 115(10): 490-495, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-36127272

RESUMO

BACKGROUND: Postoperative conduction disorders are serious adverse events in patients undergoing aortic valve replacement, and may prolong the duration of hospitalization and require pacemaker insertion. AIM: Our aim was to evaluate the rate of pacemaker insertion after implantation of an Edwards Intuity sutureless aortic valve (Edwards Lifesciences, Irvine, CA, USA) compared with a standard surgical bioprosthesis. METHODS: This retrospective single-centre study included patients who underwent aortic valve replacement with an Intuity sutureless aortic valve or a standard bioprosthetic valve between 4 June 2014 and 27 June 2016. The main outcome criterion was the rate of postoperative pacemaker insertion. Secondary outcome criteria included the rate of new conduction disorders, the rate of atrial arrhythmia or paroxysmal conduction disorders, mortality and duration of hospital stay. RESULTS: Ninety-three patients received an Intuity sutureless aortic valve (median age 76 years, interquartile range 71-80 years), and 176 were implanted with a standard biological aortic valve (median age 73 years, interquartile range 68-79 years; P=0.007). The rate of postoperative pacemaker insertion, after adjustment, was 22.44% in the Intuity group and 5.66% in the standard aortic valve group (P=0.030). The main indications for postoperative pacemaker insertion were complete atrioventricular block and left bundle branch block with prolongation of the H-V interval. The rate of new postoperative left bundle branch block conduction disorders was significantly higher in patients implanted with an Intuity valve (odds ratio 5.28, 95% confidence interval 1.59 to 23.05; P=0.012). CONCLUSION: Higher rates of pacemaker insertion and new conduction disorders were observed in patients implanted with an Intuity sutureless bioprosthesis compared with those who received a standard surgical aortic valve.


Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Marca-Passo Artificial , Humanos , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Bloqueio de Ramo , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estudos Retrospectivos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Próteses Valvulares Cardíacas/efeitos adversos , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/etiologia , Arritmias Cardíacas/terapia , Resultado do Tratamento , Desenho de Prótese
3.
Pacing Clin Electrophysiol ; 45(11): 1310-1315, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-35661380

RESUMO

BACKGROUND: Transvenous pacemaker (PM) implantation is a complication in patients undergoing transcatheter aortic valve implantation (TAVI). Recently, a second generation of leadless PMs able of atrioventricular (AV) synchronous pacing has been introduced and could be an alternative when ventricular pacing is required after TAVI. Real-world data on Micra AV after TAVI are still lacking. Our aim was to determine the per- and post-procedural outcomes in patients with Micra AV leadless PM implantation after TAVI. METHODS: A total of 20 consecutive patients underwent Micra AV leadless PM implantation after TAVI between November 2020 and June 2021. RESULTS: The main indication for ventricular pacing was high-degree AV block (55% of patients) and left bundle branch block (LBBB) associated with prolonged HV interval (45% of patients). At discharge, mean (SD) ventricular pacing threshold was 0.397 ± 0.11 V at 0.24 ms and ventricular impedance was 709.4 ± 139.1 Ω. At 1-month follow-up, 95% of patients were programmed in VDD pacing mode. Mean (SD) ventricular pacing threshold was 0.448 ± 0.094 V at 0.24 ms. In patients with ventricular> pacing > 90% (n = 5), mean AM-VP was 72.5% ± 8.3%. Pacing threshold at 1 month was not significantly different compared to discharge (p = .1088). Mean (SD) impedance was 631.0 ± 111.9 Ω, which remained stable at discharge (p = .0813). No procedural complications occurred during implantation. At 1-month follow-up, two patients displayed atrial under-sensing. CONCLUSIONS: Micra AV leadless PM implantation after TAVI is associated with a low complication rate and good device performance at 1-month post-implantation.


Assuntos
Bloqueio Atrioventricular , Marca-Passo Artificial , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento , Marca-Passo Artificial/efeitos adversos , Bloqueio de Ramo/terapia , Estimulação Cardíaca Artificial/efeitos adversos , Valva Aórtica
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA